{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:57:06Z","timestamp":1790891826210,"version":"4.1.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100008836","name":"Gaziantep \u00dcniversitesi","doi-asserted-by":"publisher","award":["DHF.UT.22.10."],"award-info":[{"award-number":["DHF.UT.22.10."]}],"id":[{"id":"10.13039\/501100008836","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Odontology"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1007\/s10266-025-01263-6","type":"journal-article","created":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T18:37:24Z","timestamp":1764441444000},"page":"2012-2020","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The effect of digital connector design on flexural and fracture strength in implant-supported bridge restorations produced with different materials"],"prefix":"10.1007","volume":"114","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5109-7987","authenticated-orcid":false,"given":"Beste","family":"Cetin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8927-3448","authenticated-orcid":false,"given":"Ozge Parlar","family":"Oz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,29]]},"reference":[{"issue":"1","key":"1263_CR1","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1111\/j.1600-0501.2004.00983.x","volume":"15","author":"IK Karoussis","year":"2004","unstructured":"Karoussis IK, Br\u00e4gger U, Salvi GE, B\u00fcrgin W, Lang NP. Effect of implant design on survival and success rates of titanium oral implants: a 10-year prospective cohort study of the ITI\u00ae dental implant system. Clin Oral Implants Res. 2004;15(1):8\u201317.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"1263_CR2","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1034\/j.1600-0501.2002.130202.x","volume":"13","author":"\u00c5 Leonhardt","year":"2002","unstructured":"Leonhardt \u00c5, Gr\u00f6ndahl K, Bergstr\u00f6m C, Lekholm U. Long-term follow-up of osseointegrated titanium implants using clinical, radiographic and microbiological parameters. Clin Oral Implants Res. 2002;13(2):127\u201332.","journal-title":"Clin Oral Implants Res"},{"key":"1263_CR3","unstructured":"Zortuk M, Eskimez \u015e, \u00d6zdemir E, Ag\u00fclo\u011flu S. Cumhuriyet \u00dcniversitesi Di\u015f Hekimli\u011fi Fak\u00fcltesi Dergisi. The effect of fatique test on the compressive fracture strength of three all ceramic crowns. 2009."},{"issue":"4","key":"1263_CR4","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1111\/jerd.12105","volume":"26","author":"A Vichi","year":"2014","unstructured":"Vichi A, Carrabba M, Paravina R, Ferrari M. Translucency of ceramic materials for CEREC CAD\/CAM system. J Esthet Restor Dent. 2014;26(4):224\u201331.","journal-title":"J Esthet Restor Dent"},{"key":"1263_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2016.08.033","volume":"32","author":"S Heintze","year":"2016","unstructured":"Heintze S, Reinhardt M, Monreal D, Kolb E, Reinshagen J, Rousson V. Fatigue resistance of 3-unit zirconia and lithium disilicate molar FPDs. Dent Mater. 2016;32:e17. https:\/\/doi.org\/10.1016\/j.dental.2016.08.033.","journal-title":"Dent Mater"},{"issue":"5","key":"1263_CR6","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1111\/j.1708-8240.2010.00362.x","volume":"22","author":"RG Ritter","year":"2010","unstructured":"Ritter RG. Multifunctional uses of a novel ceramic-lithium disilicate. J Esthet Restor Dent. 2010;22(5):332\u201341.","journal-title":"J Esthet Restor Dent"},{"issue":"5","key":"1263_CR7","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1016\/j.dental.2004.07.013","volume":"21","author":"A Sundh","year":"2005","unstructured":"Sundh A, Molin M, Sj\u00f6gren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater. 2005;21(5):476\u201382.","journal-title":"Dent Mater"},{"issue":"3","key":"1263_CR8","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1177\/154405910308200317","volume":"82","author":"H Fischer","year":"2003","unstructured":"Fischer H, Weber M, Marx R. Lifetime prediction of all-ceramic bridges by computational methods. J Dent Res. 2003;82(3):238\u201342.","journal-title":"J Dent Res"},{"issue":"4","key":"1263_CR9","first-page":"379","volume":"14","author":"PV Von Steyern","year":"2001","unstructured":"Von Steyern PV, J\u00f6nsson O, Nilner K. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont. 2001;14(4):379\u201384.","journal-title":"Int J Prosthodont."},{"issue":"4","key":"1263_CR10","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1177\/00220345980770041201","volume":"77","author":"IM Peterson","year":"1998","unstructured":"Peterson IM, Pajares A, Lawn BR, Thompson VP, Rekow ED. Mechanical characterization of dental ceramics by Hertzian contacts. J Dent Res. 1998;77(4):589\u2013602.","journal-title":"J Dent Res"},{"key":"1263_CR11","unstructured":"Nelson SJ. WHEELER\u2019S Dental Anatomy, Physiology, and Occlusion. 10th ed. Elsevier; 1974."},{"key":"1263_CR12","unstructured":"International A, indexed by mero files. Designation: D 790-00 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials 1 [Internet]. www.astm.org"},{"issue":"5","key":"1263_CR13","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1111\/jopr.12003","volume":"22","author":"MJ Ambr\u00e9","year":"2013","unstructured":"Ambr\u00e9 MJ, Aschan F, von Steyern PV. Fracture strength of yttria-stabilized zirconium-dioxide (Y-TZP) fixed dental prostheses (FDPs) with different abutment core thicknesses and connector dimensions. J Prosthodont. 2013;22(5):377\u201382.","journal-title":"J Prosthodont"},{"key":"1263_CR14","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1111\/j.1600-0501.2009.01778.x","volume":"20","author":"S Harder","year":"2009","unstructured":"Harder S, Kern M. Survival and complications of computer aided\u2010designing and computer\u2010aided manufacturing vs. conventionally fabricated implant\u2010supported reconstructions: a systematic review. Clin Oral Implants Res. 2009;20:48\u201354.","journal-title":"Clin Oral Implants Res"},{"key":"1263_CR15","unstructured":"von Steyern PV, Kokubo Y, Nilner K. Use of abutment-teeth vs. dental implants to support all-ceramic fixed partial dentures: an in-vitro study on fracture strength. Swed Dent J. 2005;29(2):53\u201360."},{"issue":"5","key":"1263_CR16","first-page":"462","volume":"6","author":"SS Scherrer","year":"1993","unstructured":"Scherrer SS, De Rijk WG. The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli. Int Prosthodont. 1993;6(5):462\u20137.","journal-title":"Int Prosthodont."},{"issue":"5","key":"1263_CR17","doi-asserted-by":"publisher","first-page":"346","DOI":"10.4047\/jap.2014.6.5.346","volume":"6","author":"M Rismanchian","year":"2014","unstructured":"Rismanchian M, Shafiei S, Nourbakhshian F, Davoudi A. Flexural strengths of implant-supported zirconia based bridges in posterior regions. J Adv Prosthodont. 2014;6(5):346\u201350.","journal-title":"J Adv Prosthodont"},{"issue":"1","key":"1263_CR18","doi-asserted-by":"publisher","DOI":"10.4317\/jced.51304","volume":"6","author":"R Agust\u00edn-Panadero","year":"2014","unstructured":"Agust\u00edn-Panadero R, Rom\u00e1n-Rodr\u00edguez JL, Ferreiroa A, Sol\u00e1-Ru\u00edz MF, Fons-Font A. Zirconia in fixed prosthesis. A literature review. J Clin Exp Dent. 2014;6(1):e66.","journal-title":"J Clin Exp Dent"},{"issue":"1","key":"1263_CR19","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1177\/0022034510384617","volume":"90","author":"N Silva","year":"2011","unstructured":"Silva N, Bonfante EA, Rafferty BT, Zavanelli RA, Rekow ED, Thompson VP, et al. Modified Y-TZP core design improves all-ceramic crown reliability. J Dent Res. 2011;90(1):104\u20138. https:\/\/doi.org\/10.1177\/0022034510384617.","journal-title":"J Dent Res"},{"issue":"8","key":"1263_CR20","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1016\/j.dental.2006.06.039","volume":"23","author":"W Kou","year":"2007","unstructured":"Kou W, Kou S, Liu H, Sj\u00f6gren G. Numerical modeling of the fracture process in a three-unit all-ceramic fixed partial denture. Dent Mater. 2007;23(8):1042\u20139.","journal-title":"Dent Mater"},{"issue":"5","key":"1263_CR21","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1111\/jopr.13430","volume":"31","author":"A Zandinejad","year":"2022","unstructured":"Zandinejad A, Das O, Barmak AB, Kuttolamadom M, Revilla-Le\u00f3n M. The flexural strength and flexural modulus of stereolithography additively manufactured zirconia with different porosities. J Prosthodont. 2022;31(5):434\u201340.","journal-title":"J Prosthodont"},{"issue":"2","key":"1263_CR22","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1016\/j.prosdent.2022.04.005","volume":"131","author":"TF Alghazzawi","year":"2024","unstructured":"Alghazzawi TF, Janowski GM, Eberhardt AW. An experimental study of flexural strength and hardness of zirconia and their relation to crown failure loads. J Prosthet Dent. 2024;131(2):320\u20138. https:\/\/doi.org\/10.1016\/j.prosdent.2022.04.005.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"1263_CR23","doi-asserted-by":"publisher","first-page":"218","DOI":"10.34172\/joddd.2020.039","volume":"14","author":"A Hafezeqoran","year":"2020","unstructured":"Hafezeqoran A, Koodaryan R, Hemmati Y, Akbarzadeh A. Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis. J Dent Res Dent Clin Dent Prospects. 2020;14(4):218.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"9","key":"1263_CR24","doi-asserted-by":"publisher","first-page":"e63","DOI":"10.1016\/j.dental.2009.05.003","volume":"25","author":"S Wolfart","year":"2009","unstructured":"Wolfart S, Eschbach S, Scherrer S, Kern M. Clinical outcome of three-unit lithium-disilicate glass\u2013ceramic fixed dental prostheses: up to 8 years results. Dent Mater. 2009;25(9):e63-71.","journal-title":"Dent Mater"},{"issue":"9","key":"1263_CR25","doi-asserted-by":"publisher","first-page":"2171","DOI":"10.1007\/s00784-014-1191-8","volume":"18","author":"S Reich","year":"2014","unstructured":"Reich S, Endres L, Weber C, Wiedhahn K, Neumann P, Schneider O, et al. Three-unit CAD\/CAM-generated lithium disilicate FDPs after a mean observation time of 46 months. Clin Oral Investig. 2014;18(9):2171\u20138.","journal-title":"Clin Oral Investig"},{"issue":"6","key":"1263_CR26","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/s0021-9290(96)00182-0","volume":"30","author":"TWP Korioth","year":"1997","unstructured":"Korioth TWP, Waldron TW, Versluis A, Schulte JK. Forces and moments generated at the dental incisors during forceful biting in humans. J Biomech. 1997;30(6):631\u20133. https:\/\/doi.org\/10.1016\/s0021-9290(96)00182-0.","journal-title":"J Biomech"},{"issue":"7","key":"1263_CR27","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1177\/00220345990780070801","volume":"78","author":"O Hidaka","year":"1999","unstructured":"Hidaka O, Iwasaki M, Saito M, Morimoto T. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure. J Dent Res. 1999;78(7):1336\u201344.","journal-title":"J Dent Res"},{"issue":"1","key":"1263_CR28","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1146\/annurev.matsci.27.1.443","volume":"27","author":"JR Kelly","year":"1997","unstructured":"Kelly JR. Ceramics in restorative and prosthetic dentistry. Annu Rev Mater Sci. 1997;27(1):443\u201368.","journal-title":"Annu Rev Mater Sci"},{"issue":"3","key":"1263_CR29","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1067\/mpr.2003.50","volume":"89","author":"MB Blatz","year":"2003","unstructured":"Blatz MB, Sadan A, Kern M. Resin-ceramic bonding: a review of the literature. J Prosthet Dent. 2003;89(3):268\u201374. https:\/\/doi.org\/10.1067\/mpr.2003.50.","journal-title":"J Prosthet Dent"}],"container-title":["Odontology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-025-01263-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10266-025-01263-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-025-01263-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:15:16Z","timestamp":1790889316000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10266-025-01263-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,29]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["1263"],"URL":"https:\/\/doi.org\/10.1007\/s10266-025-01263-6","relation":{},"ISSN":["1618-1247","1618-1255"],"issn-type":[{"value":"1618-1247","type":"print"},{"value":"1618-1255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,29]]},"assertion":[{"value":"30 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no conflicts of interest relevant to this article.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}