{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T17:20:45Z","timestamp":1775496045529,"version":"3.50.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T00:00:00Z","timestamp":1775433600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T00:00:00Z","timestamp":1775433600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Uskudar University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Odontology"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This in vitro study aimed to evaluate the accuracy of wireless electronic apex locators (EALs) in determining the working length (WL) across seven distinct types of root resorption (RR) using three-dimensionally (3D) printed tooth models. 32 transparent resin tooth models representing one non-resorptive control and seven RR types (\n                    <jats:italic>n<\/jats:italic>\n                    \u2009=\u20094 per group), including internal resorption (IRR; 0.5- and 1-mm perforations), external resorption (ERR; 0.5- and 1-mm perforations), external apical resorption (EARR; grades 2 and 3), and external cervical resorption (ECR), were fabricated with precise geometric parameters. WL was measured using four EALs (Woodpex III Gold Plus, iRoot, Wirele-X, and AirPex). Data were analyzed using appropriate parametric and non-parametric tests with intraclass correlation coefficients (ICC) (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.05). Significant differences among devices were observed in the control, IRR-0.5\u00a0mm, ERR-0.5\u00a0mm, ERR-1\u00a0mm, and EARR grade 3 (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.05) groups, whereas IRR-1\u00a0mm, EARR grade 2, and ECR groups showed no significant differences (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&gt;\u20090.05). The ICC values (0.00\u20130.55) indicated low-to-moderate consistency, with no calculable ICC in the uniform groups. ERR-1\u00a0mm represented the most challenging condition, with all devices showing high rates of mistaken measurements (75\u2013100%). The accuracy of wireless EALs was influenced by both the device type and specific resorption morphology. All devices were fully accurate in the EARR grade 3 and IRR-1\u00a0mm models, whereas ERR-1\u00a0mm, ECR, and EARR grade 2 groups exhibited reduced accuracy. Resorptive defects that disrupt dentin continuity, particularly in the apical or cervical regions, compromise measurement precision, supporting the need for radiographic confirmation in such cases.\n                  <\/jats:p>","DOI":"10.1007\/s10266-026-01379-3","type":"journal-article","created":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T15:48:52Z","timestamp":1775490532000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of wireless electronic apex locators in teeth with different types of root resorption: a 3D-printed tooth model study"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7625-1111","authenticated-orcid":false,"given":"Vahide Hazal","family":"Abat","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0096-8375","authenticated-orcid":false,"given":"G\u00f6k\u00e7en Deniz Bayrak","family":"Arslanta\u015f","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,6]]},"reference":[{"key":"1379_CR1","unstructured":"Glossary of endodontic terms - American Association of Endodontists. https:\/\/www.aae.org\/specialty\/clinical-resources\/glossary-endodontic-terms\/. Accessed 26 Jul 2025."},{"key":"1379_CR2","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/S0099-2399(07)80180-4","volume":"16","author":"U Sj\u00f6gren","year":"1990","unstructured":"Sj\u00f6gren U, H\u00e4gglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod. 1990;16:498\u2013504. https:\/\/doi.org\/10.1016\/S0099-2399(07)80180-4.","journal-title":"J Endod"},{"key":"1379_CR3","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1016\/J.JOEN.2015.04.015","volume":"41","author":"L Khojastepour","year":"2015","unstructured":"Khojastepour L, Moazami F, Babaei M, Forghani M. Assessment of root perforation within simulated internal resorption cavities using cone-beam computed tomography. J Endod. 2015;41:1520\u20133. https:\/\/doi.org\/10.1016\/J.JOEN.2015.04.015.","journal-title":"J Endod"},{"key":"1379_CR4","doi-asserted-by":"publisher","first-page":"1716","DOI":"10.1016\/j.joen.2017.05.012","volume":"43","author":"ATG Cruz","year":"2017","unstructured":"Cruz ATG, Wichnieski C, Carneiro E, da Silva Neto UX, Gambarini G, Piasecki L. Accuracy of 2 endodontic rotary motors with integrated apex locator. J Endod. 2017;43:1716\u20139. https:\/\/doi.org\/10.1016\/j.joen.2017.05.012.","journal-title":"J Endod"},{"key":"1379_CR5","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1016\/j.joen.2017.03.039","volume":"43","author":"TN Oliveira","year":"2017","unstructured":"Oliveira TN, Vivacqua-Gomes N, Bernardes RA, Vivan RR, Duarte MAH, Vasconcelos BC. Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols. J Endod. 2017;43:1663\u20137. https:\/\/doi.org\/10.1016\/j.joen.2017.03.039.","journal-title":"J Endod"},{"key":"1379_CR6","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/374971","volume":"2014","author":"A Gesi","year":"2014","unstructured":"Gesi A, Mareschi P, Doldo T, Ferrari M. Apical dimension of root canal clinically assessed with and without periapical lesions. Int J Dent. 2014;2014:374971. https:\/\/doi.org\/10.1155\/2014\/374971.","journal-title":"Int J Dent"},{"issue":"1","key":"1379_CR7","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1111\/AEJ.12688","volume":"49","author":"L Brand","year":"2023","unstructured":"Brand L, Dunlap CA, Scott R, Arias A, Peters O. An in vitro evaluation of the WIRELE-x electronic apex locator. Aust Endod J. 2023;49(1):41\u20135. https:\/\/doi.org\/10.1111\/AEJ.12688.","journal-title":"Aust Endod J"},{"key":"1379_CR8","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.joen.2023.02.011","volume":"49","author":"G De-Deus","year":"2023","unstructured":"De-Deus G, Cozer V, Souza EM, et al. Clinical accuracy and precision of 3 multifrequency electronic apex locators assessed through micro\u2013computed tomographic imaging. J Endod. 2023;49:487\u201395. https:\/\/doi.org\/10.1016\/j.joen.2023.02.011.","journal-title":"J Endod"},{"key":"1379_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-024-05387-z","volume":"24","author":"A Oncu","year":"2024","unstructured":"Oncu A, Sisko E, Demirel A, Celikten B. The evaluation of the accuracy of a wireless electronic apex locator in primary molar teeth. BMC Oral Health. 2024;24:1580. https:\/\/doi.org\/10.1186\/s12903-024-05387-z.","journal-title":"BMC Oral Health"},{"key":"1379_CR10","unstructured":"Woodpex III Gold Plus apex locater \u2013 WOODPECKER https:\/\/www.glwoodpecker.com\/#\/pchome. Accessed 28 Nov 2025."},{"key":"1379_CR11","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.joen.2008.10.017","volume":"35","author":"A ElAyouti","year":"2009","unstructured":"ElAyouti A, Dima E, Ohmer J, Sperl K, von Ohle C, L\u00f6st C. Consistency of apex locator function: a clinical study. J Endod. 2009;35:179\u201381. https:\/\/doi.org\/10.1016\/j.joen.2008.10.017.","journal-title":"J Endod"},{"key":"1379_CR12","doi-asserted-by":"publisher","first-page":"281","DOI":"10.7508\/IEJ.2015.04.014","volume":"10","author":"M Forghani","year":"2015","unstructured":"Forghani M, Farooji EM, Abuchenari J, Bidar M, Eslami N. Conservative treatment of an invaginated maxillary lateral incisor with a c-shaped canal using cone-beam computed tomography. Iran Endod J. 2015;10:281\u20133. https:\/\/doi.org\/10.7508\/IEJ.2015.04.014.","journal-title":"Iran Endod J"},{"key":"1379_CR13","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1016\/j.joen.2007.04.013","volume":"33","author":"H Jafarzadeh","year":"2007","unstructured":"Jafarzadeh H, Abbott PV. Dilaceration: review of an endodontic challenge. J Endod. 2007;33:1025\u201330. https:\/\/doi.org\/10.1016\/j.joen.2007.04.013.","journal-title":"J Endod"},{"key":"1379_CR14","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1111\/iej.13916","volume":"56","author":"S Patel","year":"2023","unstructured":"Patel S, Krastl G, Weiger R, et al. ESE position statement on root resorption. Int Endod J. 2023;56:792\u2013801. https:\/\/doi.org\/10.1111\/iej.13916.","journal-title":"Int Endod J"},{"key":"1379_CR15","unstructured":"DentaPort ZX apex locator|MORITA [cited 2025 Nov 28]. https:\/\/www.morita.com\/anz\/en\/products\/endodontic-systems\/apex-locators\/dentaport-root-zx-1."},{"key":"1379_CR16","unstructured":"Bomedent IRoot apex operation manual (page 3 of 36)|ManualsLib https:\/\/www.manualslib.com\/manual\/2474466\/Bomedent-Iroot-Apex.html?page=3#manual. Accessed 28 Jul 2025."},{"issue":"1","key":"1379_CR17","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1111\/aej.12724","volume":"49","author":"J Nam","year":"2023","unstructured":"Nam J, Piasecki L, Kwak D, et al. Variations in the morphology of apical constriction affecting electronic readings: an in vitro investigation using 3D-printed tooth models. Aust Endod J. 2023;49(1):245\u201352. https:\/\/doi.org\/10.1111\/aej.12724.","journal-title":"Aust Endod J"},{"key":"1379_CR18","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/B978-0-323-06489-7.00007-2","volume-title":"Cohen's pathways of the pulp","author":"F Vertucci","year":"2011","unstructured":"Vertucci F, Haddix J. Tooth morphology and access cavity preparation. In: Hargreaves Kenneth M, Cohen Stephen, editors. Cohen\u2019s pathways of the pulp. 10th ed. Amsterdam: Elsevier; 2011. p. 136\u2013222.","edition":"10"},{"issue":"1","key":"1379_CR19","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1093\/ejo\/10.1.30","volume":"10","author":"E Levander","year":"1988","unstructured":"Levander E, Malmgren O. Evaluation of the risk of root resorption during orthodontic treatment: a study of upper incisors. Eur J Orthod. 1988;10(1):30\u20138. https:\/\/doi.org\/10.1093\/ejo\/10.1.30.","journal-title":"Eur J Orthod"},{"issue":"1","key":"1379_CR20","first-page":"27","volume":"30","author":"GS Heithersay","year":"1985","unstructured":"Heithersay GS. Clinical, radiologic, and histopathologic features of invasive cervical resorption. Quintessence Int. 1985;30(1):27\u201337.","journal-title":"Quintessence Int"},{"key":"1379_CR21","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1111\/IEJ.12824","volume":"51","author":"S Patel","year":"2018","unstructured":"Patel S, Foschi F, Mannocci F, Patel K. External cervical resorption: a three-dimensional classification. Int Endod J. 2018;51:206\u201314. https:\/\/doi.org\/10.1111\/IEJ.12824.","journal-title":"Int Endod J"},{"key":"1379_CR22","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1097\/00004770-200206000-00011","volume":"28","author":"F Goldberg","year":"2002","unstructured":"Goldberg F, De Silvio AC, Manfre S, Nastri N. In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption. J Endod. 2002;28:461\u20133. https:\/\/doi.org\/10.1097\/00004770-200206000-00011.","journal-title":"J Endod"},{"key":"1379_CR23","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1111\/j.1747-4477.2012.00367.x","volume":"39","author":"M Lipski","year":"2013","unstructured":"Lipski M, Trabska-\u015awistelnicka M, Wo\u017aniak K, Dembowska E, Dro\u017adzik A. Evaluation of alginate as a substitute for root-surrounding tissues in electronic root canal measurements. Aust Endod J. 2013;39:155\u20138. https:\/\/doi.org\/10.1111\/j.1747-4477.2012.00367.x.","journal-title":"Aust Endod J"},{"key":"1379_CR24","doi-asserted-by":"publisher","first-page":"918","DOI":"10.3390\/medicina59050918","volume":"59","author":"SI C\u00eempean","year":"2023","unstructured":"C\u00eempean SI, Chisnoiu RM, Colceriu Burtea AL, Rotaru R, Bud MG, Delean AG, et al. In vitro evaluation of the accuracy of three electronic apex locators using different sodium hypochlorite concentrations. Medicina. 2023;59:918. https:\/\/doi.org\/10.3390\/medicina59050918.","journal-title":"Medicina"},{"key":"1379_CR25","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1007\/S00784-021-04103-3","volume":"26","author":"RA Bernardes","year":"2022","unstructured":"Bernardes RA, Feitosa APOP, Bramante CM, et al. Evaluation of foramen locating accuracy of an endodontic motor integrated with electronic foramen employing optimal glide path kinematics. Clin Oral Investig. 2022;26:1293\u20138. https:\/\/doi.org\/10.1007\/S00784-021-04103-3.","journal-title":"Clin Oral Investig"},{"key":"1379_CR26","doi-asserted-by":"publisher","first-page":"232","DOI":"10.4103\/endo.endo_122_21","volume":"33","author":"P Jha","year":"2021","unstructured":"Jha P, Nikhil V, Raj S, Ravinder R, Mishra P. Accuracy of electronic apex locator in the presence of different irrigating solutions. Endodontology. 2021;33:232\u20136. https:\/\/doi.org\/10.4103\/endo.endo_122_21.","journal-title":"Endodontology"},{"key":"1379_CR27","doi-asserted-by":"publisher","first-page":"2211","DOI":"10.1016\/j.jds.2025.06.017","volume":"20","author":"SY Chen","year":"2025","unstructured":"Chen SY, Wu YC, Wu JR, et al. Innovative 3D-printed dental teaching model for root canal treatment simulation. J Dent Sci. 2025;20:2211\u20138. https:\/\/doi.org\/10.1016\/j.jds.2025.06.017.","journal-title":"J Dent Sci"},{"key":"1379_CR28","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.joen.2014.02.004","volume":"40","author":"FLC D\u2019Assun\u00e7\u00e3o","year":"2014","unstructured":"D\u2019Assun\u00e7\u00e3o FLC, Sousa JCN, Felinto KCA, et al. Accuracy and repeatability of 3 apex locators in locating root canal perforations: an ex vivo study. J Endod. 2014;40:1241\u20134. https:\/\/doi.org\/10.1016\/j.joen.2014.02.004.","journal-title":"J Endod"},{"key":"1379_CR29","doi-asserted-by":"publisher","DOI":"10.30476\/dentjods.2021.91056.1548","author":"A Adibi","year":"2022","unstructured":"Adibi A, Sobhnamayan F, Ostovar Zijerdi N, et al. Comparison of the accuracy of CBCT \u0131mages and apex locator in detection of external root resorption with perforation. J Dent Shiraz. 2022. https:\/\/doi.org\/10.30476\/dentjods.2021.91056.1548.","journal-title":"J Dent Shiraz"},{"key":"1379_CR30","doi-asserted-by":"publisher","first-page":"521","DOI":"10.17219\/dmp\/166408","volume":"62","author":"D Erkal","year":"2025","unstructured":"Erkal D, Toros A, Dermanl\u0131 H, et al. Accuracy of electronic apex locators in the determination of the working length in teeth with natural apical root resorption in the presence of different irrigation solutions. Dent Med Probl. 2025;62:521\u20136. https:\/\/doi.org\/10.17219\/dmp\/166408.","journal-title":"Dent Med Probl"},{"key":"1379_CR31","doi-asserted-by":"publisher","DOI":"10.4103\/drj.drj_546_22","volume":"21","author":"SM Hasheminia","year":"2024","unstructured":"Hasheminia SM, Jahadi S, Moghaddam FG, Bagherieh S. Comparison of the accuracy of apex locator, digital radiography, and cone-beam computed tomography in root canal working length determination in teeth with external root resorption: an in vitro study. Dent Res J Isfahan. 2024;21:8. https:\/\/doi.org\/10.4103\/drj.drj_546_22.","journal-title":"Dent Res J Isfahan"},{"key":"1379_CR32","doi-asserted-by":"publisher","DOI":"10.3390\/clinpract12060107","volume":"12","author":"M Ramezani","year":"2022","unstructured":"Ramezani M, Bolbolian M, Aliakbari M, et al. Accuracy of three types of apex locators versus digital periapical radiography for working length determination in maxillary premolars: an in vitro study. Clin Pract Oxf. 2022;12:1043. https:\/\/doi.org\/10.3390\/clinpract12060107.","journal-title":"Clin Pract Oxf"},{"key":"1379_CR33","unstructured":"Diana R, Castagnola R, Colangeli M, et al. Comparative evaluation of the accuracy of the airpex ond dentaport Zx apex locators in detecting working length: an ex vivo study. Endodontics&Restorative- roots. 2021. https:\/\/www.eighteeth.com\/article-endodontics-restorative\/289.html. Accessed 28 Nov 2025."},{"key":"1379_CR34","doi-asserted-by":"publisher","first-page":"12","DOI":"10.22037\/IEJ.V15I1.26720","volume":"15","author":"K Van Pham","year":"2020","unstructured":"Van Pham K, Khuc NK. The accuracy of endodontic length measurement using cone-beam computed tomography in comparison with electronic apex locators. Iran Endod J. 2020;15:12\u20137. https:\/\/doi.org\/10.22037\/IEJ.V15I1.26720.","journal-title":"Iran Endod J"},{"issue":"25","key":"1379_CR35","doi-asserted-by":"publisher","first-page":"00588","DOI":"10.1016\/j.joen.2025.09.012","volume":"S0099\u20132399","author":"K-W Tung","year":"2025","unstructured":"Tung K-W, Sasaki H, Cavalcanti B, Gardner R, McDonald N. Influence of anatomical parameters on the accuracy of electronic apex locators in C shaped canals: a novel micro-CT analysis incorporating feret diameter. J Endod. 2025;S0099\u20132399(25):00588\u201396. https:\/\/doi.org\/10.1016\/j.joen.2025.09.012.","journal-title":"J Endod"},{"issue":"2","key":"1379_CR36","doi-asserted-by":"publisher","DOI":"10.21142\/2523-2754-0902-2021-055","volume":"9","author":"TF Astocaza Re\u00e1tegui","year":"2021","unstructured":"Astocaza Re\u00e1tegui TF, Ayarza Fl\u00f3rez LR, Garc\u00eda Rupaya CR. Comparison of the precision of two electronic apical locators in teeth with simulated perforations. Rev Cient Odontol (Lima). 2021;9(2):e0559. https:\/\/doi.org\/10.21142\/2523-2754-0902-2021-055.","journal-title":"Rev Cient Odontol (Lima)"},{"issue":"1","key":"1379_CR37","doi-asserted-by":"publisher","DOI":"10.1186\/S12903-025-06828-Z","volume":"25","author":"ZG \u00dcr\u00fcn","year":"2025","unstructured":"\u00dcr\u00fcn ZG, \u00c7elikten B, T\u0131naz AC. Accuracy of two electronic apex locators in mandibular mesial canals and the influence of root canal anatomy: a micro-CT-based study. BMC Oral Health. 2025;25(1):1676. https:\/\/doi.org\/10.1186\/S12903-025-06828-Z.","journal-title":"BMC Oral Health"},{"issue":"8","key":"1379_CR38","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1111\/J.1365-2591.2004.00835.x","volume":"37","author":"MPJ Gordon","year":"2004","unstructured":"Gordon MPJ, Chandler NP. Electronic apex locators. Int Endod J. 2004;37(8):425\u201337. https:\/\/doi.org\/10.1111\/J.1365-2591.2004.00835.x.","journal-title":"Int Endod J"},{"key":"1379_CR39","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.joen.2007.05.009","volume":"33","author":"M Herrera","year":"2007","unstructured":"Herrera M, \u00c1balos C, Planas AJ, Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod. 2007;33:995\u20138. https:\/\/doi.org\/10.1016\/j.joen.2007.05.009.","journal-title":"J Endod"},{"key":"1379_CR40","doi-asserted-by":"publisher","first-page":"113","DOI":"10.5395\/rde.2015.40.2.113","volume":"40","author":"P-J Kim","year":"2015","unstructured":"Kim P-J, et al. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators. Restor Dent Endod. 2015;40:113\u201322. https:\/\/doi.org\/10.5395\/rde.2015.40.2.113.","journal-title":"Restor Dent Endod"},{"issue":"3","key":"1379_CR41","first-page":"288","volume":"15","author":"D Angerame","year":"2014","unstructured":"Angerame D, De Biasi M, Marigo L, Castagnola R, Somma F, Castaldo A. Influence of simulated apical resorption following orthodontic treatment on working length determination: an in vitro study. Eur J Paediatr Dent. 2014;15(3):288\u201392.","journal-title":"Eur J Paediatr Dent"},{"key":"1379_CR42","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/S1079-2104(96)80361-1","volume":"82","author":"Z Fuss","year":"1996","unstructured":"Fuss Z, Assooline LS, Kaufman AY. Determination of location of root perforations by electronic apex locators. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996;82:324\u20139. https:\/\/doi.org\/10.1016\/S1079-2104(96)80361-1.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"1379_CR43","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/S0099-2399(06)80053-1","volume":"20","author":"C Kobayashi","year":"1994","unstructured":"Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod. 1994;20:111\u20134. https:\/\/doi.org\/10.1016\/S0099-2399(06)80053-1.","journal-title":"J Endod"},{"key":"1379_CR44","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1111\/iej.13299","volume":"53","author":"A Hanafi","year":"2020","unstructured":"Hanafi A, Donnermeyer D, Sch\u00e4fer E, B\u00fcrklein S. Perception of a modular 3D print model in undergraduate endodontic education. Int Endod J. 2020;53:1007\u201316. https:\/\/doi.org\/10.1111\/iej.13299.","journal-title":"Int Endod J"},{"key":"1379_CR45","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jdent.2017.06.005","volume":"64","author":"M Wolgin","year":"2017","unstructured":"Wolgin M, Grundmann MJ, Tchorz JP, Frank W, Kielbassa AM. Ex vivo investigation on the postoperative integrity of the apical constriction after the sole use of electronic working length determination. J Dent. 2017;64:52\u20137. https:\/\/doi.org\/10.1016\/j.jdent.2017.06.005.","journal-title":"J Dent"}],"container-title":["Odontology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-026-01379-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10266-026-01379-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-026-01379-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T15:48:56Z","timestamp":1775490536000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10266-026-01379-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,6]]},"references-count":45,"alternative-id":["1379"],"URL":"https:\/\/doi.org\/10.1007\/s10266-026-01379-3","relation":{},"ISSN":["1618-1247","1618-1255"],"issn-type":[{"value":"1618-1247","type":"print"},{"value":"1618-1255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,6]]},"assertion":[{"value":"12 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No ethical approval was required since the study used three-dimensionally (3D)-printed synthetic models with no human or animal tissue.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This study did not require informed consent as it was conducted solely on 3D-printed models.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}