{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T06:27:28Z","timestamp":1788848848503,"version":"build-2803163510"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,2,14]],"date-time":"2025-02-14T00:00:00Z","timestamp":1739491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,2,14]],"date-time":"2025-02-14T00:00:00Z","timestamp":1739491200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82172051"],"award-info":[{"award-number":["82172051"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"DOI":"10.1007\/s10278-024-01287-4","type":"journal-article","created":{"date-parts":[[2025,2,14]],"date-time":"2025-02-14T13:16:31Z","timestamp":1739538991000},"page":"4216-4225","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Impact of Combined Deep Learning Image Reconstruction and Metal Artifact Reduction Algorithm on CT Image Quality in Different Scanning Conditions for Maxillofacial Region with Metal Implants: A Phantom Study"],"prefix":"10.1007","volume":"38","author":[{"given":"Gongxin","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haowei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qifan","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huimin","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,14]]},"reference":[{"key":"1287_CR1","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.rx.2018.02.009","volume":"60","author":"D MeraFern\u00e1ndez","year":"2018","unstructured":"Mera Fern\u00e1ndez D, Santos Armentia E, Bustos Fiore A, Villanueva Campos AM, Utrera P\u00e9rez E, Souto Bayarri M: The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling. Radiologia 60:312-319, 2018","journal-title":"Radiologia"},{"key":"1287_CR2","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/s12880-021-00554-y","volume":"21","author":"FA Huber","year":"2021","unstructured":"Huber FA, Sprengel K, M\u00fcller L, Graf LC, Osterhoff G, Guggenberger R: Comparison of different CT metal artifact reduction strategies for standard titanium and carbon-fiber reinforced polymer implants in sheep cadavers. BMC medical imaging 21:29, 2021","journal-title":"BMC medical imaging"},{"key":"1287_CR3","doi-asserted-by":"publisher","first-page":"20190385","DOI":"10.1259\/dmfr.20190385","volume":"49","author":"LAC Martins","year":"2020","unstructured":"Martins LAC, Queiroz PM, Nejaim Y, Vasconcelos KF, Groppo FC, Haiter-Neto F: Evaluation of metal artefacts for two CBCT devices with a new dental arch phantom. Dentomaxillofac Radiol 49:20190385, 2020","journal-title":"Dentomaxillofac Radiol"},{"key":"1287_CR4","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1109\/TBME.1982.324900","volume":"29","author":"M Nassi","year":"1982","unstructured":"Nassi M, Brody WR, Medoff BP, Macovski A: Iterative reconstruction--reprojection: an algorithm for limited data cardiac-computed tomography. IEEE transactions on bio-medical engineering 29:333-341, 1982","journal-title":"IEEE transactions on bio-medical engineering"},{"key":"1287_CR5","doi-asserted-by":"publisher","first-page":"4526","DOI":"10.1118\/1.2789499","volume":"34","author":"JB Thibault","year":"2007","unstructured":"Thibault JB, Sauer KD, Bouman CA, Hsieh J: A three-dimensional statistical approach to improved image quality for multislice helical CT. Medical physics 34:4526-4544, 2007","journal-title":"Medical physics"},{"key":"1287_CR6","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1148\/radiol.12112265","volume":"264","author":"CH McCollough","year":"2012","unstructured":"McCollough CH, Chen GH, Kalender W, Leng S, Samei E, Taguchi K, Wang G, Yu L, Pettigrew RI: Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology 264:567-580, 2012","journal-title":"Radiology"},{"key":"1287_CR7","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1007\/s00261-016-1023-1","volume":"42","author":"J Fang","year":"2017","unstructured":"Fang J, Zhang D, Wilcox C, Heidinger B, Raptopoulos V, Brook A, Brook OR: Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model. Abdominal radiology (New York) 42:742-748, 2017","journal-title":"Abdominal radiology (New York)"},{"key":"1287_CR8","doi-asserted-by":"crossref","unstructured":"Troeltzsch D, Shnayien S, Heiland M, Kreutzer K, Raguse JD, Hamm B, Niehues SM: Detectability of Head and Neck Cancer via New Computed Tomography Reconstruction Tools including Iterative Reconstruction and Metal Artifact\u00a0Reduction. Diagnostics (Basel, Switzerland) 11:2154, 2021","DOI":"10.3390\/diagnostics11112154"},{"key":"1287_CR9","doi-asserted-by":"publisher","first-page":"20180909","DOI":"10.1259\/bjr.20180909","volume":"92","author":"H Tang","year":"2019","unstructured":"Tang H, Liu Z, Hu Z, He T, Li D, Yu N, Jia Y, Shi H: Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT. Br J Radiol 92:20180909, 2019","journal-title":"Br J Radiol"},{"key":"1287_CR10","doi-asserted-by":"publisher","first-page":"3609","DOI":"10.1007\/s00330-017-4733-z","volume":"27","author":"HG Kim","year":"2017","unstructured":"Kim HG, Lee HJ, Lee SK, Kim HJ, Kim MJ: Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol 27:3609-3617, 2017","journal-title":"Eur Radiol"},{"key":"1287_CR11","doi-asserted-by":"publisher","first-page":"20170655","DOI":"10.1259\/bjr.20170655","volume":"91","author":"LH Chen","year":"2018","unstructured":"Chen LH, Jin C, Li JY, Wang GL, Jia YJ, Duan HF, Pan N, Guo J: Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT. Br J Radiol 91:20170655, 2018","journal-title":"Br J Radiol"},{"key":"1287_CR12","doi-asserted-by":"publisher","first-page":"2185","DOI":"10.1007\/s00330-018-5810-7","volume":"29","author":"MJ Willemink","year":"2019","unstructured":"Willemink MJ, No\u00ebl PB: The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. Eur Radiol 29:2185-2195, 2019","journal-title":"Eur Radiol"},{"key":"1287_CR13","doi-asserted-by":"publisher","first-page":"3951","DOI":"10.1007\/s00330-020-06724-w","volume":"30","author":"J Greffier","year":"2020","unstructured":"Greffier J, Hamard A, Pereira F, Barrau C, Pasquier H, Beregi JP, Frandon J: Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study. Eur Radiol 30:3951-3959, 2020","journal-title":"Eur Radiol"},{"key":"1287_CR14","doi-asserted-by":"publisher","first-page":"1390","DOI":"10.1007\/s10278-023-00806-z","volume":"36","author":"J Zhong","year":"2023","unstructured":"Zhong J, Shen H, Chen Y, Xia Y, Shi X, Lu W, Li J, Xing Y, Hu Y, Ge X, Ding D, Jiang Z, Yao W: Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT. Journal of digital imaging 36:1390-1407, 2023","journal-title":"Journal of digital imaging"},{"key":"1287_CR15","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1007\/s11604-021-01089-6","volume":"39","author":"Y Ichikawa","year":"2021","unstructured":"Ichikawa Y, Kanii Y, Yamazaki A, Nagasawa N, Nagata M, Ishida M, Kitagawa K, Sakuma H: Deep learning image reconstruction for improvement of image quality of abdominal computed tomography: comparison with hybrid iterative reconstruction. Japanese Journal of Radiology 39:598-604, 2021","journal-title":"Japanese Journal of Radiology"},{"key":"1287_CR16","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1007\/s00330-022-09146-y","volume":"33","author":"L Cao","year":"2023","unstructured":"Cao L, Liu X, Qu T, Cheng Y, Li J, Li Y, Chen L, Niu X, Tian Q, Guo J: Improving spatial resolution and diagnostic confidence with thinner slice and deep learning image reconstruction in contrast-enhanced abdominal CT. Eur Radiol 33:1603-1611, 2023","journal-title":"Eur Radiol"},{"key":"1287_CR17","first-page":"286","volume":"52","author":"W Zeng","year":"2021","unstructured":"Zeng W, Zeng LM, Xu X, Hu SX, Liu KL, Zhang JG, Peng WL, Xia CC, Li ZL: [Noise Reduction Effect of Deep-learning-based Image Reconstruction Algorithms in Thin-section Chest CT]. Sichuan Da Xue Xue Bao Yi Xue Ban 52:286-292, 2021","journal-title":"Sichuan Da Xue Xue Bao Yi Xue Ban"},{"key":"1287_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13871","volume":"24","author":"A Svalkvist","year":"2023","unstructured":"Svalkvist A, Fagman E, Vikgren J, Ku S, Diniz MO, Norrlund RR, Johnsson AA: Evaluation of deep-learning image reconstruction for chest CT examinations at two different dose levels. J Appl Clin Med Phys 24:e13871, 2023","journal-title":"J Appl Clin Med Phys"},{"key":"1287_CR19","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13244-020-0836-1","volume":"11","author":"Y Wei","year":"2020","unstructured":"Wei Y, Jia F, Hou P, Zha K, Pu S, Gao J: Clinical application of multi-material artifact reduction (MMAR) technique in Revolution CT to reduce metallic dental artifacts. Insights into imaging 11:32, 2020","journal-title":"Insights into imaging"},{"key":"1287_CR20","doi-asserted-by":"publisher","first-page":"20190058","DOI":"10.1259\/dmfr.20190058","volume":"48","author":"EHL Nascimento","year":"2019","unstructured":"Nascimento EHL, Fontenele RC, Santaella GM, Freitas DQ: Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant. Dentomaxillofac Radiol 48:20190058, 2019","journal-title":"Dentomaxillofac Radiol"},{"key":"1287_CR21","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.diii.2017.11.003","volume":"99","author":"A Larbi","year":"2018","unstructured":"Larbi A, Orliac C, Frandon J, Pereira F, Ruyer A, Goupil J, Macri F, Beregi JP, Greffier J: Detection and characterization of focal liver lesions with ultra-low dose computed tomography in neoplastic patients. Diagnostic and interventional imaging 99:311-320, 2018","journal-title":"Diagnostic and interventional imaging"},{"key":"1287_CR22","unstructured":"Hsieh J, Liu E, Nett B, Tang J, Thibault J-B, Sahney S: A new era of image reconstruction: TrueFidelity\u2122. White Paper (JB68676XX), GE Healthcare, 2019"},{"key":"1287_CR23","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1055\/a-1248-2556","volume":"193","author":"C Arndt","year":"2021","unstructured":"Arndt C, G\u00fcttler F, Heinrich A, B\u00fcrckenmeyer F, Diamantis I, Teichgr\u00e4ber U: Deep Learning CT Image Reconstruction in Clinical Practice. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 193:252-261, 2021","journal-title":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin"},{"key":"1287_CR24","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.221257","volume":"306","author":"LR Koetzier","year":"2023","unstructured":"Koetzier LR, Mastrodicasa D, Szczykutowicz TP, van der Werf NR, Wang AS, Sandfort V, van der Molen AJ, Fleischmann D, Willemink MJ: Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects. Radiology 306:e221257, 2023","journal-title":"Radiology"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-024-01287-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-024-01287-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-024-01287-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T19:24:34Z","timestamp":1765567474000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-024-01287-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,14]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1287"],"URL":"https:\/\/doi.org\/10.1007\/s10278-024-01287-4","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,14]]},"assertion":[{"value":"20 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}},{"value":"This is a phantom study. The Institutional Review Board has confirmed that no ethical approval is required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"A phantom study does not require informed consent.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"This is a phantom study. Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}}]}}