{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T06:26:18Z","timestamp":1774592778527,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100019084","name":"Kobe University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100019084","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aimed to evaluate the image quality of virtual monochromatic images (VMIs) reconstructed with deep learning image reconstruction (DLIR) using dual-energy CT (DECT) to diagnose pancreatic ductal adenocarcinoma (PDAC). Fifty patients with histologically confirmed PDAC who underwent multiphasic contrast-enhanced DECT between 2019 and 2022 were retrospectively analyzed. VMIs at 40\u2013100\u00a0keV were reconstructed using hybrid iterative reconstruction (ASiR-V 30% and ASiR-V 50%) and DLIR (TFI-M) algorithms. Quantitative analyses included contrast-to-noise ratios (CNR) of the major abdominal vessels, liver, pancreas, and the PDAC. Qualitative image quality assessments included image noise, soft-tissue sharpness, vessel contrast, and PDAC conspicuity. Noise power spectrum (NPS) analysis was performed to examine the variance and spatial frequency characteristics of image noise using a phantom. TFI-M significantly improved image quality compared to ASiR-V 30% and ASiR-V 50%, especially at lower keV levels. VMIs with TFI-M showed reduced image noise and higher pancreas-to-tumor CNR at 40\u00a0keV. Qualitative evaluations confirmed DLIR's superiority in noise reduction, tissue sharpness, and vessel conspicuity, with substantial interobserver agreement (\u03ba\u2009=\u20090.61\u20130.78). NPS analysis demonstrated effective noise reduction across spatial frequencies. DLIR significantly improved the image quality of VMIs on DECT by reducing image noise and increasing CNR, particularly at lower keV levels. These improvements may improve PDAC detection and assessment, making it a valuable tool for pancreatic cancer imaging.<\/jats:p>","DOI":"10.1007\/s10278-025-01514-6","type":"journal-article","created":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T04:02:26Z","timestamp":1746072146000},"page":"815-826","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Improved Image Quality of Virtual Monochromatic Images with Deep Learning Image Reconstruction Algorithm on Dual-Energy CT in Patients with Pancreatic Ductal Adenocarcinoma"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6132-1623","authenticated-orcid":false,"given":"Keitaro","family":"Sofue","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eisuke","family":"Ueshima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiko","family":"Ueno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeru","family":"Yamaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatoshi","family":"Hori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takamichi","family":"Murakami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,30]]},"reference":[{"key":"1514_CR1","unstructured":"Tempero MA, Malafa MP, Al-Hawary M, et al (2021) Pancreatic Adenocarcinoma, Version 2.2021, NCCN Clinical Practice Guidelines in Oncology. J Natl Compr Canc Netw. 19(4):439\u2013457."},{"issue":"3","key":"1514_CR2","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1148\/radiol.2018180628","volume":"289","author":"SB Hong","year":"2018","unstructured":"Hong SB, Lee SS, Kim JH, et al (2018) Pancreatic Cancer CT: Prediction of Resectability according to NCCN Criteria. Radiology. 289(3):710-718.","journal-title":"Radiology."},{"issue":"2","key":"1514_CR3","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1148\/radiol.14140206","volume":"274","author":"OR Brook","year":"2015","unstructured":"Brook OR, Brook A, Vollmer CM, Kent TS, Sanchez N, Pedrosa I (2015) Structured reporting of multiphasic CT for pancreatic cancer: potential effect on staging and surgical planning. Radiology. 274(2):464-472.","journal-title":"Radiology."},{"issue":"2","key":"1514_CR4","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1148\/radiol.2019190422","volume":"293","author":"I Joo","year":"2019","unstructured":"Joo I, Lee JM, Lee ES, et al (2019) Preoperative CT Classification of the Resectability of Pancreatic Cancer: Interobserver Agreement. Radiology. 293(2):343-349.","journal-title":"Radiology."},{"issue":"1","key":"1514_CR5","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1148\/radiol.10100015","volume":"257","author":"JH Kim","year":"2010","unstructured":"Kim JH, Park SH, Yu ES, et al (2010) Visually isoattenuating pancreatic adenocarcinoma at dynamic-enhanced CT: frequency, clinical and pathologic characteristics, and diagnosis at imaging examinations. Radiology. 257(1):87-96.","journal-title":"Radiology."},{"issue":"2","key":"1514_CR6","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1148\/radiol.11101133","volume":"259","author":"SH Yoon","year":"2011","unstructured":"Yoon SH, Lee JM, Cho JY, et al (2011) Small (\u2264 20 mm) pancreatic adenocarcinomas: analysis of enhancement patterns and secondary signs with multiphasic multidetector CT. Radiology. 259(2):442-452.","journal-title":"Radiology."},{"issue":"922","key":"1514_CR7","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1259\/bjr\/19527646","volume":"77","author":"S Fenchel","year":"2004","unstructured":"Fenchel S, Fleiter TR, Aschoff AJ, van Gessel R, Brambs HJ, Merkle EM (2004) Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas. Br J Radiol. 77(922):821-830.","journal-title":"Br J Radiol."},{"issue":"2","key":"1514_CR8","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1148\/radiol.10091819","volume":"256","author":"D Marin","year":"2010","unstructured":"Marin D, Nelson RC, Barnhart H, et al (2010) Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique--preliminary results. Radiology. 256(2):450-459.","journal-title":"Radiology."},{"issue":"4","key":"1514_CR9","doi-asserted-by":"publisher","first-page":"888","DOI":"10.2214\/AJR.20.25430","volume":"217","author":"Y Fukukura","year":"2021","unstructured":"Fukukura Y, Kumagae Y, Fujisaki Y, et al (2021) Adding Delayed Phase Images to Dual-Phase Contrast-Enhanced CT Increases Sensitivity for Small Pancreatic Ductal Adenocarcinoma. AJR Am J Roentgenol. 217(4):888-897.","journal-title":"AJR Am J Roentgenol."},{"issue":"2","key":"1514_CR10","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1007\/s00261-018-1754-2","volume":"44","author":"S Aslan","year":"2019","unstructured":"Aslan S, Camlidag I, Nural MS (2019) Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT. Abdom Radiol (NY). 44(2):568-575.","journal-title":"Abdom Radiol (NY)."},{"issue":"2","key":"1514_CR11","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1148\/radiol.14131480","volume":"271","author":"D Marin","year":"2014","unstructured":"Marin D, Boll DT, Mileto A, Nelson RC (2014) State of the art: dual-energy CT of the abdomen. Radiology. 271(2):327-342.","journal-title":"Radiology."},{"issue":"2","key":"1514_CR12","doi-asserted-by":"publisher","first-page":"161","DOI":"10.3390\/diagnostics11020161","volume":"11","author":"M Tsurusaki","year":"2021","unstructured":"Tsurusaki M, Sofue K, Hori M, et al (2021) Dual-Energy Computed Tomography of the Liver: Uses in Clinical Practices and Applications. Diagnostics (Basel). 11(2):161.","journal-title":"Diagnostics (Basel)."},{"issue":"3","key":"1514_CR13","doi-asserted-by":"publisher","first-page":"651","DOI":"10.2214\/AJR.20.25093","volume":"217","author":"A Mileto","year":"2021","unstructured":"Mileto A, Ananthakrishnan L, Morgan DE, Yeh BM, Marin D, Kambadakone AR (2021) Clinical Implementation of Dual-Energy CT for Gastrointestinal Imaging. AJR Am J Roentgenol. 217(3):651-663.","journal-title":"AJR Am J Roentgenol."},{"issue":"9","key":"1514_CR14","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1097\/RLI.0000000000000060","volume":"49","author":"KL Grant","year":"2014","unstructured":"Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol. 49(9):586-592.","journal-title":"Invest Radiol."},{"issue":"6","key":"1514_CR15","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.2214\/AJR.15.15512","volume":"206","author":"D Marin","year":"2016","unstructured":"Marin D, Ramirez-Giraldo JC, Gupta S, et al (2016) Effect of a Noise-Optimized Second-Generation Monoenergetic Algorithm on Image Noise and Conspicuity of Hypervascular Liver Tumors: An In Vitro and In Vivo Study. AJR Am J Roentgenol. 206(6):1222-32.","journal-title":"AJR Am J Roentgenol."},{"key":"1514_CR16","unstructured":"Hsieh J LE, Nett B, Tang J, Thibault JB, Sahney S. A new era of image reconstruction: TrueFidelity-technical white paper on deep learning image reconstruction. GE Healthcare website wwwgehealthcarecom\/-\/jssmedia\/040dd213fa89463287155151fdb01922pdf Published 2019."},{"issue":"1","key":"1514_CR17","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2214\/AJR.19.22332","volume":"215","author":"CT Jensen","year":"2020","unstructured":"Jensen CT, Liu X, Tamm EP, et al (2020) Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience. AJR Am J Roentgenol. 215(1):50-57.","journal-title":"AJR Am J Roentgenol."},{"issue":"5","key":"1514_CR18","doi-asserted-by":"publisher","first-page":"3156","DOI":"10.1007\/s00330-020-07358-8","volume":"31","author":"C Park","year":"2021","unstructured":"Park C, Choo KS, Jung Y, Jeong HS, Hwang JY, Yun MS (2021) CT iterative vs deep learning reconstruction: comparison of noise and sharpness. Eur Radiol. 31(5):3156-3164","journal-title":"Eur Radiol."},{"issue":"9","key":"1514_CR19","doi-asserted-by":"publisher","first-page":"710.e15","DOI":"10.1016\/j.crad.2021.03.010","volume":"76","author":"T Kaga","year":"2021","unstructured":"Kaga T, Noda Y, Fujimoto K, et al (2021) Deep-learning-based image reconstruction in dynamic contrast-enhanced abdominal CT: image quality and lesion detection among reconstruction strength levels. Clin Radiol. 76(9):710.e15-710.e24.","journal-title":"Clin Radiol."},{"key":"1514_CR20","doi-asserted-by":"crossref","unstructured":"Noda Y, Goshima S, Kaga T, et al (2020) Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol. 75(4):320.e17\u2013320e23.","DOI":"10.1016\/j.crad.2019.11.012"},{"key":"1514_CR21","doi-asserted-by":"crossref","unstructured":"Boedeker KL, Cooper VN, McNitt-Gray MF (2007) Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta. Phys Med Biol. 52(14):4027\u20134046.","DOI":"10.1088\/0031-9155\/52\/14\/002"},{"issue":"9","key":"1514_CR22","doi-asserted-by":"publisher","first-page":"3961","DOI":"10.1002\/mp.14319","volume":"47","author":"J Solomon","year":"2020","unstructured":"Solomon J, Lyu P, Marin D, Samei E (2020) Noise and spatial resolution properties of a commercially available deep learning-based CT reconstruction algorithm. Med Phys. 47(9):3961-3971.","journal-title":"Med Phys."},{"issue":"1","key":"1514_CR23","doi-asserted-by":"publisher","first-page":"43","DOI":"10.5334\/jbsr.2444","volume":"105","author":"H Hamasaki","year":"2021","unstructured":"Hamasaki H, Shirasaka T, Ushijima Y, et al (2021) Improvement of Image Quality Using Hybrid Iterative Reconstruction with Noise Power Spectrum Model in Computed Tomography During Hepatic Arteriography. J Belg Soc Radiol. 105(1):43.","journal-title":"J Belg Soc Radiol."},{"issue":"11","key":"1514_CR24","doi-asserted-by":"publisher","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","volume":"29","author":"M Akagi","year":"2019","unstructured":"Akagi M, Nakamura Y, Higaki T, et al (2019) Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT. Eur Radiol. 29(11):6163-6171.","journal-title":"Eur Radiol."},{"issue":"8","key":"1514_CR25","doi-asserted-by":"publisher","first-page":"2724","DOI":"10.1007\/s00261-023-03966-2","volume":"48","author":"MA Shehata","year":"2023","unstructured":"Shehata MA, Saad AM, Kamel S, et al (2023) Deep-learning CT reconstruction in clinical scans of the abdomen: a systematic review and meta-analysis. Abdom Radiol (NY). 48(8):2724-2756.","journal-title":"Abdom Radiol (NY)."}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01514-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01514-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01514-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T18:46:31Z","timestamp":1771526791000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01514-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,30]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["1514"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01514-6","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,30]]},"assertion":[{"value":"7 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 April 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was a retrospective analysis of a prospectively collected cohort, approved by the Institutional Review Board, with a waiver of written informed consent. This study protocol conforms to the Declaration of Helsinki and Ethical Guidelines for Medical and Health Research Involving Human Subjects.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Statement"}},{"value":"This study was a retrospective analysis of a prospectively collected cohort, approved by the Institutional Review Board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"The Institutional Review Board waived written informed consent because of retrospective nature of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}