{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T20:30:47Z","timestamp":1786998647284,"version":"build-2736575974"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004721","name":"The University of Tokyo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004721","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    CT imaging is useful for evaluating complications related to central venous catheter insertion; however, it involves exposure to ionizing radiation. This study aimed to evaluate the impact of super-resolution deep learning reconstruction (SR-DLR) on the quality of low-dose CT imaging compared to hybrid iterative reconstruction (HIR) in patients with central venous catheter or central venous port. In this retrospective study, chest CT images were reconstructed using SR-DLR and HIR from source data acquired with a three-dimensional landmark scan during scout imaging. Three readers independently assessed the quality of images in terms of noise, artifacts, depiction of the brachiocephalic vein and superior vena cava, and ease of evaluating hematoma and catheter location. The standard deviation of CT attenuation within a region of interest placed in the right atrium was recorded as quantitative image noise. All readers rated noise, artifacts, and depiction of the brachiocephalic vein as significantly improved in SR-DLR compared to HIR (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2264\u20090.042). Two out of three readers rated depiction of the superior vena cava, ease of evaluating hematoma, and catheter location as significantly improved in SR-DLR compared to HIR (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2264\u20090.016). Quantitative image noise in SR-DLR was 10.2\u00a0Hounsfield unit, which was significantly reduced compared to HIR (24.0 Hounsfield unit) (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). When sufficient information can be obtained from these images, the main CT scans may be omitted. In conclusion, SR-DLR enhanced the quality of low-dose CT imaging compared to HIR in patients with central venous catheter or central venous port.\n                  <\/jats:p>","DOI":"10.1007\/s10278-025-01726-w","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T16:09:33Z","timestamp":1761667773000},"page":"3524-3531","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Impact of Super-Resolution Deep Learning Reconstruction on Low-Dose CT in Patients with Central Venous Catheter or Central Venous Port"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0324-6562","authenticated-orcid":false,"given":"Koichiro","family":"Yasaka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miyaka","family":"Wada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kishin","family":"Tokuyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taku","family":"Takaishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Abe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,10,28]]},"reference":[{"issue":"5","key":"1726_CR1","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1001\/jamainternmed.2023.8232","volume":"184","author":"B Teja","year":"2024","unstructured":"Teja B, Bosch NA, Diep C et al (2024) Complication Rates of Central Venous Catheters: A Systematic Review and Meta-Analysis. JAMA Intern Med 184(5):474-482. https:\/\/doi.org\/10.1001\/jamainternmed.2023.8232.","journal-title":"JAMA Intern Med"},{"issue":"1","key":"1726_CR2","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13244-019-0770-2","volume":"10","author":"S Machat","year":"2019","unstructured":"Machat S, Eisenhuber E, Pfarl G et al (2019) Complications of central venous port systems: a pictorial review. Insights Imaging 10(1):86. https:\/\/doi.org\/10.1186\/s13244-019-0770-2.","journal-title":"Insights Imaging"},{"issue":"1","key":"1726_CR3","doi-asserted-by":"publisher","first-page":"6726","DOI":"10.1038\/s41598-021-86322-y","volume":"11","author":"HK Yoon","year":"2021","unstructured":"Yoon HK, Hur M, Cho H et al (2021) Effects of practitioner's experience on the clinical performance of ultrasound-guided central venous catheterization: a randomized trial. Sci Rep 11(1):6726. https:\/\/doi.org\/10.1038\/s41598-021-86322-y.","journal-title":"Sci Rep"},{"issue":"1","key":"1726_CR4","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1186\/s13054-017-1814-y","volume":"21","author":"B Saugel","year":"2017","unstructured":"Saugel B, Scheeren TWL, Teboul JL (2017) Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care 21(1):225. https:\/\/doi.org\/10.1186\/s13054-017-1814-y.","journal-title":"Crit Care"},{"issue":"6","key":"1726_CR5","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1001\/jamainternmed.2025.0505","volume":"185","author":"R Smith-Bindman","year":"2025","unstructured":"Smith-Bindman R, Chu PW, Azman Firdaus H et al (2025) Projected Lifetime Cancer Risks From Current Computed Tomography Imaging. JAMA Intern Med 185(6):710-719. https:\/\/doi.org\/10.1001\/jamainternmed.2025.0505.","journal-title":"JAMA Intern Med"},{"issue":"4","key":"1726_CR6","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s11604-018-0726-3","volume":"36","author":"K Yasaka","year":"2018","unstructured":"Yasaka K, Akai H, Kunimatsu A, Kiryu S, Abe O (2018) Deep learning with convolutional neural network in radiology. Jpn J Radiol 36(4):257-272. https:\/\/doi.org\/10.1007\/s11604-018-0726-3.","journal-title":"Jpn J Radiol"},{"issue":"7","key":"1726_CR7","doi-asserted-by":"publisher","first-page":"2113","DOI":"10.1148\/rg.2017170077","volume":"37","author":"G Chartrand","year":"2017","unstructured":"Chartrand G, Cheng PM, Vorontsov E et al (2017) Deep Learning: A Primer for Radiologists. Radiographics 37(7):2113-2131. https:\/\/doi.org\/10.1148\/rg.2017170077.","journal-title":"Radiographics"},{"issue":"1150","key":"1726_CR8","doi-asserted-by":"publisher","first-page":"20220685","DOI":"10.1259\/bjr.20220685","volume":"96","author":"K Yasaka","year":"2023","unstructured":"Yasaka K, Hatano S, Mizuki M et al (2023) Effects of deep learning on radiologists' and radiology residents\u2019 performance in identifying esophageal cancer on CT. Br J Radiol 96(1150):20220685. https:\/\/doi.org\/10.1259\/bjr.20220685.","journal-title":"Br J Radiol"},{"issue":"1","key":"1726_CR9","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1148\/radiol.2018180901","volume":"290","author":"D Ueda","year":"2019","unstructured":"Ueda D, Yamamoto A, Nishimori M et al (2019) Deep Learning for MR Angiography: Automated Detection of Cerebral Aneurysms. Radiology 290(1):187-194. https:\/\/doi.org\/10.1148\/radiol.2018180901.","journal-title":"Radiology"},{"issue":"1","key":"1726_CR10","doi-asserted-by":"publisher","first-page":"e41","DOI":"10.1016\/j.crad.2023.09.022","volume":"79","author":"K Yasaka","year":"2024","unstructured":"Yasaka K, Sato C, Hirakawa H et al (2024) Impact of deep learning on radiologists and radiology residents in detecting breast cancer on CT: a cross-vendor test study. Clin Radiol 79(1):e41-e47. https:\/\/doi.org\/10.1016\/j.crad.2023.09.022.","journal-title":"Clin Radiol"},{"issue":"12","key":"1726_CR11","doi-asserted-by":"publisher","first-page":"9612","DOI":"10.1007\/s00330-021-08014-5","volume":"31","author":"Y Li","year":"2021","unstructured":"Li Y, Zhang Y, Zhang E et al (2021) Differential diagnosis of benign and malignant vertebral fracture on CT using deep learning. Eur Radiol 31(12):9612-9619. https:\/\/doi.org\/10.1007\/s00330-021-08014-5.","journal-title":"Eur Radiol"},{"issue":"3","key":"1726_CR12","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1148\/radiol.2017170706","volume":"286","author":"K Yasaka","year":"2018","unstructured":"Yasaka K, Akai H, Abe O, Kiryu S (2018) Deep Learning with Convolutional Neural Network for Differentiation of Liver Masses at Dynamic Contrast-enhanced CT: A Preliminary Study. Radiology 286(3):887-896. https:\/\/doi.org\/10.1148\/radiol.2017170706.","journal-title":"Radiology"},{"key":"1726_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-024-03427-7","author":"J Kanzawa","year":"2024","unstructured":"Kanzawa J, Yasaka K, Fujita N, Fujiwara S, Abe O (2024) Automated classification of brain MRI reports using fine-tuned large language models. Neuroradiology https:\/\/doi.org\/10.1007\/s00234-024-03427-7.","journal-title":"Neuroradiology"},{"issue":"1","key":"1726_CR14","doi-asserted-by":"publisher","first-page":"e250867","DOI":"10.1148\/radiol.250867","volume":"315","author":"K Yasaka","year":"2025","unstructured":"Yasaka K, Abe O (2025) A New Step Forward in the Extraction of Appropriate Radiology Reports. Radiology 315(1):e250867. https:\/\/doi.org\/10.1148\/radiol.250867.","journal-title":"Radiology"},{"key":"1726_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-025-01433-6","author":"N Kanemaru","year":"2025","unstructured":"Kanemaru N, Yasaka K, Okimoto N et al (2025) Efficacy of Fine-Tuned Large Language Model in CT Protocol Assignment as Clinical Decision-Supporting System. J Imaging Inform Med https:\/\/doi.org\/10.1007\/s10278-025-01433-6.","journal-title":"J Imaging Inform Med"},{"key":"1726_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s10140-025-02354-1","author":"N Fujita","year":"2025","unstructured":"Fujita N, Yasaka K, Kiryu S, Abe O (2025) Fine-tuned large Language model for extracting newly identified acute brain infarcts based on computed tomography or magnetic resonance imaging reports. Emerg Radiol https:\/\/doi.org\/10.1007\/s10140-025-02354-1.","journal-title":"Emerg Radiol"},{"key":"1726_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-025-05062-z","author":"M Sato","year":"2025","unstructured":"Sato M, Yasaka K, Abe S et al (2025) Efficacy of a large language model in classifying branch-duct intraductal papillary mucinous neoplasms. Abdom Radiol (NY) https:\/\/doi.org\/10.1007\/s00261-025-05062-z.","journal-title":"Abdom Radiol (NY)"},{"key":"1726_CR18","doi-asserted-by":"publisher","first-page":"e57275","DOI":"10.2196\/57275","volume":"11","author":"Y Yamagishi","year":"2025","unstructured":"Yamagishi Y, Nakamura Y, Hanaoka S, Abe O (2025) Large Language Model Approach for Zero-Shot Information Extraction and Clustering of Japanese Radiology Reports: Algorithm Development and Validation. JMIR Cancer 11:e57275. https:\/\/doi.org\/10.2196\/57275.","journal-title":"JMIR Cancer"},{"issue":"6","key":"1726_CR19","doi-asserted-by":"publisher","first-page":"e220133","DOI":"10.1148\/rg.220133","volume":"43","author":"S Kiryu","year":"2023","unstructured":"Kiryu S, Akai H, Yasaka K et al (2023) Clinical Impact of Deep Learning Reconstruction in MRI. Radiographics 43(6):e220133. https:\/\/doi.org\/10.1148\/rg.220133.","journal-title":"Radiographics"},{"issue":"5","key":"1726_CR20","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1007\/s00330-021-08438-z","volume":"32","author":"JA van Stiphout","year":"2022","unstructured":"van Stiphout JA, Driessen J, Koetzier LR et al (2022) The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis. Eur Radiol 32(5):2921-2929. https:\/\/doi.org\/10.1007\/s00330-021-08438-z.","journal-title":"Eur Radiol"},{"issue":"4","key":"1726_CR21","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s00261-023-03834-z","volume":"48","author":"N Okimoto","year":"2023","unstructured":"Okimoto N, Yasaka K, Kaiume M, Kanemaru N, Suzuki Y, Abe O (2023) Improving detection performance of hepatocellular carcinoma and interobserver agreement for liver imaging reporting and data system on CT using deep learning reconstruction. Abdom Radiol (NY) 48(4):1280-1289. https:\/\/doi.org\/10.1007\/s00261-023-03834-z.","journal-title":"Abdom Radiol (NY)"},{"issue":"8","key":"1726_CR22","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1007\/s11604-023-01402-5","volume":"41","author":"R Hosoi","year":"2023","unstructured":"Hosoi R, Yasaka K, Mizuki M et al (2023) Deep learning reconstruction with single-energy metal artifact reduction in pelvic computed tomography for patients with metal hip prostheses. Jpn J Radiol 41(8):863-871. https:\/\/doi.org\/10.1007\/s11604-023-01402-5.","journal-title":"Jpn J Radiol"},{"key":"1726_CR23","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-023-03251-5","author":"N Okimoto","year":"2023","unstructured":"Okimoto N, Yasaka K, Fujita N, Watanabe Y, Kanzawa J, Abe O (2023) Deep learning reconstruction for improving the visualization of acute brain infarct on computed tomography. Neuroradiology https:\/\/doi.org\/10.1007\/s00234-023-03251-5.","journal-title":"Neuroradiology"},{"key":"1726_CR24","doi-asserted-by":"publisher","unstructured":"Fujita N, Yasaka K, Watanabe Y, Okimoto N, Konishiike M, Abe O (2023) Detection of Vertebral Mass and Diagnosis of Spinal Cord Compression in Computed Tomography With Deep Learning Reconstruction: Comparison With Hybrid Iterative Reconstruction. Can Assoc Radiol J:8465371231203508. https:\/\/doi.org\/10.1177\/08465371231203508.","DOI":"10.1177\/08465371231203508"},{"issue":"4","key":"1726_CR25","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1177\/08465371231169672","volume":"74","author":"N Fujita","year":"2023","unstructured":"Fujita N, Yasaka K, Katayama A, Ohtake Y, Konishiike M, Abe O (2023) Assessing the Effects of Deep Learning Reconstruction on Abdominal CT Without Arm Elevation. Can Assoc Radiol J 74(4):688-694. https:\/\/doi.org\/10.1177\/08465371231169672.","journal-title":"Can Assoc Radiol J"},{"issue":"3","key":"1726_CR26","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1177\/08465371241228468","volume":"75","author":"A Hamada","year":"2024","unstructured":"Hamada A, Yasaka K, Hatano S et al (2024) Deep-Learning Reconstruction of High-Resolution CT Improves Interobserver Agreement for the Evaluation of Pulmonary Fibrosis. Can Assoc Radiol J 75(3):542-548. https:\/\/doi.org\/10.1177\/08465371241228468.","journal-title":"Can Assoc Radiol J"},{"issue":"Suppl 6","key":"1726_CR27","doi-asserted-by":"publisher","first-page":"F26","DOI":"10.1007\/s10406-007-0225-6","volume":"17","author":"C Catalano","year":"2007","unstructured":"Catalano C, Francone M, Ascarelli A, Mangia M, Iacucci I, Passariello R (2007) Optimizing radiation dose and image quality. Eur Radiol 17 Suppl 6:F26-32. https:\/\/doi.org\/10.1007\/s10406-007-0225-6.","journal-title":"Eur Radiol"},{"issue":"12","key":"1726_CR28","doi-asserted-by":"publisher","first-page":"8488","DOI":"10.1007\/s00330-023-09888-3","volume":"33","author":"Y Nagayama","year":"2023","unstructured":"Nagayama Y, Emoto T, Kato Y et al (2023) Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography. Eur Radiol 33(12):8488-8500. https:\/\/doi.org\/10.1007\/s00330-023-09888-3.","journal-title":"Eur Radiol"},{"issue":"4","key":"1726_CR29","doi-asserted-by":"publisher","first-page":"e230085","DOI":"10.1148\/ryct.230085","volume":"5","author":"M Takafuji","year":"2023","unstructured":"Takafuji M, Kitagawa K, Mizutani S et al (2023) Super-Resolution Deep Learning Reconstruction for Improved Image Quality of Coronary CT Angiography. Radiol Cardiothorac Imaging 5(4):e230085. https:\/\/doi.org\/10.1148\/ryct.230085.","journal-title":"Radiol Cardiothorac Imaging"},{"key":"1726_CR30","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-025-01849-8","author":"K Yasaka","year":"2025","unstructured":"Yasaka K, Tsujimoto R, Miyo R, Abe O (2025) Reducing motion artifacts in the aorta: super-resolution deep learning reconstruction with motion reduction algorithm. Jpn J Radiol https:\/\/doi.org\/10.1007\/s11604-025-01849-8.","journal-title":"Jpn J Radiol"},{"key":"1726_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-025-01760-2","author":"M Takafuji","year":"2025","unstructured":"Takafuji M, Kitagawa K, Mizutani S et al (2025) Super-resolution deep learning reconstruction for improved quality of myocardial CT late enhancement. Jpn J Radiol https:\/\/doi.org\/10.1007\/s11604-025-01760-2.","journal-title":"Jpn J Radiol"},{"issue":"7","key":"1726_CR32","doi-asserted-by":"publisher","first-page":"e240083","DOI":"10.1148\/rg.240083","volume":"45","author":"R Fukui","year":"2025","unstructured":"Fukui R, Harashima S, Samejima W et al (2025) Acquisition and Reconstruction Techniques for Coronary CT Angiography: Current Status and Trends over the Past Decade. Radiographics 45(7):e240083. https:\/\/doi.org\/10.1148\/rg.240083.","journal-title":"Radiographics"},{"issue":"9","key":"1726_CR33","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1177\/0284185116684675","volume":"58","author":"K Yasaka","year":"2017","unstructured":"Yasaka K, Furuta T, Kubo T et al (2017) Full and hybrid iterative reconstruction to reduce artifacts in abdominal CT for patients scanned without arm elevation. Acta Radiol 58(9):1085-1093. https:\/\/doi.org\/10.1177\/0284185116684675.","journal-title":"Acta Radiol"},{"issue":"7","key":"1726_CR34","doi-asserted-by":"publisher","first-page":"1922","DOI":"10.1148\/rg.2015150048","volume":"35","author":"AR Seyal","year":"2015","unstructured":"Seyal AR, Arslanoglu A, Abboud SF, Sahin A, Horowitz JM, Yaghmai V (2015) CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach. Radiographics 35(7):1922-1939. https:\/\/doi.org\/10.1148\/rg.2015150048.","journal-title":"Radiographics"},{"issue":"9","key":"1726_CR35","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1007\/s11604-016-0566-y","volume":"34","author":"K Yasaka","year":"2016","unstructured":"Yasaka K, Maeda E, Hanaoka S, Katsura M, Sato J, Ohtomo K (2016) Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses. Jpn J Radiol 34(9):625-632. https:\/\/doi.org\/10.1007\/s11604-016-0566-y.","journal-title":"Jpn J Radiol"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01726-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01726-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01726-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T19:32:24Z","timestamp":1786995144000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01726-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,28]]},"references-count":35,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["1726"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01726-w","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,28]]},"assertion":[{"value":"5 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 October 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was approved by our research ethics committee.","order":1,"name":"Ethics","label":"Ethics Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived due to the retrospective nature of this study.","order":2,"name":"Ethics","label":"Informed Consent","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}