{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T19:31:38Z","timestamp":1786476698393,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:00:00Z","timestamp":1786406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:00:00Z","timestamp":1786406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004332","name":"Seoul National University Hospital","doi-asserted-by":"publisher","award":["0420252160"],"award-info":[{"award-number":["0420252160"]}],"id":[{"id":"10.13039\/501100004332","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002551","name":"Seoul National University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002551","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Limited longitudinal field of view in cone-beam computed tomography (CBCT) remains a significant challenge for image-guided adaptive radiotherapy. We developed a deep learning\u2013based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume. The model employs a dual-branch encoder\u2013decoder architecture that separately encodes CBCT and edge maps derived from planning CT (pCT) and integrates them via attention-guided skip connections and late fusion to preserve structure while accommodating cross-modality differences. The framework was trained and validated using 90 prostate cancer cases, with 20 held-out patients used for quantitative evaluation against four baseline models. The proposed method achieved the lowest absolute volume difference for the clinical target volume at 0.11\u2009\u00b1\u20090.07\u00a0cc and for the planning target volume at 0.05\u2009\u00b1\u20090.04\u00a0cc. It also yielded superior perceptual image quality, with LPIPS of 0.119\u2009\u00b1\u20090.029 and FID of 54.70. Qualitative assessment confirmed improved soft-tissue continuity and more faithful preservation of anatomical landmarks in both bony and low-contrast regions. These results demonstrate that the proposed framework can restore CBCT longitudinal coverage with high anatomical fidelity, supporting more reliable deformable registration and adaptive radiotherapy workflows in clinical environments constrained by limited-FOV CBCT.<\/jats:p>","DOI":"10.1007\/s10278-026-02180-y","type":"journal-article","created":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T19:10:12Z","timestamp":1786475412000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Planning CT-Guided Dual-Branch Attention GAN for Longitudinal CBCT Outpainting in Adaptive Radiotherapy"],"prefix":"10.1007","author":[{"given":"Soyoung","family":"Chung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Ho","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Gyo","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5046-4418","authenticated-orcid":false,"given":"Hyeongmin","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,11]]},"reference":[{"key":"2180_CR1","doi-asserted-by":"publisher","first-page":"193","DOI":"10.7150\/ijms.3635","volume":"9","author":"R Baskar","year":"2012","unstructured":"Baskar R, Lee KA, Yeo R, Yeoh K-W. Cancer and radiation therapy: current advances and future directions. Int J Med Sci. 2012;9:193\u20139. https:\/\/doi.org\/10.7150\/ijms.3635","journal-title":"Int J Med Sci."},{"key":"2180_CR2","doi-asserted-by":"publisher","unstructured":"Dona Lemus OM, Cao M, Cai B, Cummings M, Zheng D. Adaptive Radiotherapy: Next-Generation Radiotherapy. Cancers (Basel). Multidisciplinary Digital Publishing Institute (MDPI); 2024. https:\/\/doi.org\/10.3390\/cancers16061206","DOI":"10.3390\/cancers16061206"},{"key":"2180_CR3","doi-asserted-by":"publisher","unstructured":"Lavrova E, Garrett MD, Wang YF, Chin C, Elliston C, Savacool M, et al. Adaptive Radiation Therapy: A Review of CT-based Techniques. Radiol. Imaging Cancer. Radiological Society of North America Inc.; 2023. https:\/\/doi.org\/10.1148\/rycan.230011","DOI":"10.1148\/rycan.230011"},{"key":"2180_CR4","doi-asserted-by":"publisher","unstructured":"Ahunbay EE, Peng C, Holmes S, Godley A, Lawton C, Li XA. Online Adaptive Replanning Method for Prostate Radiotherapy. International Journal of Radiation Oncology*Biology*Physics [Internet]. 2010;77:1561\u201372. https:\/\/doi.org\/10.1016\/j.ijrobp.2009.10.013","DOI":"10.1016\/j.ijrobp.2009.10.013"},{"key":"2180_CR5","doi-asserted-by":"crossref","unstructured":"Zhang Y-D, Govindaraj VV, Tang C, Zhu W, Sun J. High performance multiple sclerosis classification by data augmentation and AlexNet transfer learning model. J Med Imaging Health Inform. American Scientific Publishers; 2019;9:2012\u201321.","DOI":"10.1166\/jmihi.2019.2692"},{"key":"2180_CR6","doi-asserted-by":"publisher","unstructured":"Alagarsamy S, Govindaraj V, A S. Automated Brain Tumor Segmentation for MR Brain Images Using Artificial Bee Colony Combined With Interval Type-II Fuzzy Technique. IEEE Trans Industr Inform. 2023;19:11150\u20139. https:\/\/doi.org\/10.1109\/TII.2023.3244344","DOI":"10.1109\/TII.2023.3244344"},{"key":"2180_CR7","doi-asserted-by":"publisher","unstructured":"Chen K, Wang Y, Ji S, Meng C, Pan C, Tang Z, et al. A comprehensive review of CT artifact reduction: From traditional reduction techniques to deep learning methods. Computerized Medical Imaging and Graphics [Internet]. Pergamon; 2026 [cited 2026 Mar 16];129:102728. https:\/\/doi.org\/10.1016\/j.compmedimag.2026.102728","DOI":"10.1016\/j.compmedimag.2026.102728"},{"key":"2180_CR8","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1007\/978-3-031-72378-0_2","volume-title":"Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2024","author":"ME Liman","year":"2024","unstructured":"Liman ME, Rueckert D, Fintelmann FJ, M\u00fcller P. Diffusion-Based Generative Image Outpainting for\u00a0Recovery of\u00a0FOV-Truncated CT Images. In: Linguraru MG, Dou Q, Feragen A, Giannarou S, Glocker B, Lekadir K, et al., editors. Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2024. Cham: Springer Nature Switzerland; 2024. p. 14\u201323."},{"key":"2180_CR9","doi-asserted-by":"publisher","unstructured":"Lei Y, Wang T, Harms J, Shafai-Erfani G, Dong X, Tang X, et al. Image quality improvement in cone-beam CT using deep learning. In: Bosmans H, Chen G-H, Gilat Schmidt T, editors. Medical Imaging 2019: Physics of Medical Imaging. SPIE; 2019. p. 78. https:\/\/doi.org\/10.1117\/12.2512545","DOI":"10.1117\/12.2512545"},{"key":"2180_CR10","doi-asserted-by":"publisher","unstructured":"Chen J, Lee RJ, Handrahan D, Sause WT. Intensity-Modulated Radiotherapy Using Implanted Fiducial Markers With Daily Portal Imaging: Assessment of Prostate Organ Motion. International Journal of Radiation Oncology*Biology*Physics [Internet]. 2007;68:912\u20139. https:\/\/doi.org\/10.1016\/j.ijrobp.2007.02.024","DOI":"10.1016\/j.ijrobp.2007.02.024"},{"key":"2180_CR11","doi-asserted-by":"publisher","unstructured":"Hirose Y, Tomita T, Kitsuda K, Notogawa T, Miki K, Nakamura K, et al. Evaluation of different set-up error corrections on dose\u2013volume metrics in prostate IMRT using CBCT images. J Radiat Res. 2014;55. https:\/\/doi.org\/10.1093\/jrr\/rru033","DOI":"10.1093\/jrr\/rru033"},{"key":"2180_CR12","doi-asserted-by":"publisher","unstructured":"Woerner AJ, Choi M, Harkenrider MM, Roeske JC, Surucu M. Evaluation of Deformable Image Registration-Based Contour Propagation From Planning CT to Cone-Beam CT. Technol Cancer Res Treat. SAGE Publications Inc.; 2017;16:801\u201310. https:\/\/doi.org\/10.1177\/1533034617697242","DOI":"10.1177\/1533034617697242"},{"key":"2180_CR13","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/978-3-319-24553-9_48","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2015","author":"B Fuerst","year":"2015","unstructured":"Fuerst B, Fotouhi J, Navab N. Vision-Based Intraoperative Cone-Beam CT Stitching for Non-overlapping Volumes. In: Navab N, Hornegger J, Wells WM, Frangi A, editors. Medical Image Computing and Computer-Assisted Intervention -- MICCAI 2015. Cham: Springer International Publishing; 2015. p. 387\u201395."},{"key":"2180_CR14","doi-asserted-by":"publisher","first-page":"320","DOI":"10.3390\/tomography10030025","volume":"10","author":"M Li","year":"2024","unstructured":"Li M, Qu W, Zhang D, Zhong B, Li Z, Jiang Z, et al. Evaluation of Radiation Exposure and Influential Factors in Cone-Beam Computed Tomography (CBCT) of the Head and Abdomen during Interventional Procedures. Tomography. Multidisciplinary Digital Publishing Institute (MDPI); 2024;10:320\u201330. https:\/\/doi.org\/10.3390\/tomography10030025","journal-title":"Tomography. Multidisciplinary Digital Publishing Institute (MDPI)"},{"key":"2180_CR15","doi-asserted-by":"publisher","unstructured":"Liang X, Morgan H, Nguyen D, Jiang S. Deep Learning\u2013Based CT-to-CBCT Deformable Image Registration for Autosegmentation in Head and Neck Adaptive Radiation Therapy. Journal of Artificial Intelligence for Medical Sciences. KEO Tongda (Henan) Information Technology Co., Ltd; 2021;2:62\u201375. https:\/\/doi.org\/10.2991\/jaims.d.210527.001","DOI":"10.2991\/jaims.d.210527.001"},{"key":"2180_CR16","doi-asserted-by":"publisher","unstructured":"Chang Y, Liang Y, Yang B, Qiu J, Pei X, Xu XG. Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy. Radiation Oncology. BioMed Central Ltd; 2023;18. https:\/\/doi.org\/10.1186\/s13014-022-02191-3","DOI":"10.1186\/s13014-022-02191-3"},{"key":"2180_CR17","doi-asserted-by":"publisher","unstructured":"Altalib A, McGregor S, Li C, Perelli A. Synthetic CT Image Generation From CBCT: A Systematic Review. IEEE Trans Radiat Plasma Med Sci. 2025;1\u20131. https:\/\/doi.org\/10.1109\/TRPMS.2025.3533749","DOI":"10.1109\/TRPMS.2025.3533749"},{"key":"2180_CR18","doi-asserted-by":"publisher","unstructured":"Wang R, Heimann AF, Tannast M, Zheng G. CycleSGAN: A cycle-consistent and semantics-preserving generative adversarial network for unpaired MR-to-CT image synthesis. Computerized Medical Imaging and Graphics [Internet]. Pergamon; 2024 [cited 2026 Mar 16];117:102431. https:\/\/doi.org\/10.1016\/j.compmedimag.2024.102431","DOI":"10.1016\/j.compmedimag.2024.102431"},{"key":"2180_CR19","doi-asserted-by":"publisher","unstructured":"Wang S-H, Govindaraj VV, G\u00f3rriz JM, Zhang X, Zhang Y-D. Covid-19 classification by FGCNet with deep feature fusion from graph convolutional network and convolutional neural network. Information Fusion [Internet]. 2021;67:208\u201329. https:\/\/doi.org\/10.1016\/j.inffus.2020.10.004","DOI":"10.1016\/j.inffus.2020.10.004"},{"key":"2180_CR20","doi-asserted-by":"crossref","unstructured":"Isola P, Zhu J-Y, Zhou T, Efros AA. Image-to-Image Translation with Conditional Adversarial Networks. The IEEE\/CVF Conference on Computer Vision and Pattern Recognition. 2017;","DOI":"10.1109\/CVPR.2017.632"},{"key":"2180_CR21","unstructured":"Miyato T, Kataoka T, Koyama M, Yoshida Y. Spectral Normalization for Generative Adversarial Networks. The Sixth International Conference on Learning Representations. 2018;"},{"key":"2180_CR22","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1007\/978-3-319-46475-6_43","volume-title":"Computer Vision \u2013 ECCV 2016","author":"J Johnson","year":"2016","unstructured":"Johnson J, Alahi A, Fei-Fei L. Perceptual Losses for Real-Time Style Transfer and Super-Resolution. In: Leibe B, Matas J, Sebe N, Welling M, editors. Computer Vision \u2013 ECCV 2016. Cham: Springer International Publishing; 2016. p. 694\u2013711."},{"key":"2180_CR23","doi-asserted-by":"publisher","unstructured":"Nanni L, Lumini A, Brahnam S. Local binary patterns variants as texture descriptors for medical image analysis. Artif Intell Med [Internet]. 2010;49:117\u201325. https:\/\/doi.org\/10.1016\/j.artmed.2010.02.006","DOI":"10.1016\/j.artmed.2010.02.006"},{"key":"2180_CR24","unstructured":"Van Hoorick B. Image Outpainting and Harmonization using Generative Adversarial Networks. 2019; http:\/\/arxiv.org\/abs\/1912.10960"},{"key":"2180_CR25","doi-asserted-by":"crossref","unstructured":"Yu J, Lin Z, Yang J, Shen X, Lu X, Huang TS. Generative Image Inpainting with Contextual Attention. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR). 2018;5505\u201314.","DOI":"10.1109\/CVPR.2018.00577"},{"key":"2180_CR26","doi-asserted-by":"publisher","unstructured":"Krishnan D, Teterwak P, Sarna A, Maschinot A, Liu C, Belanger D, et al. Boundless: Generative Adversarial Networks for Image Extension. 2019 IEEE\/CVF International Conference on Computer Vision (ICCV). 2019. p. 10520\u20139. https:\/\/doi.org\/10.1109\/ICCV.2019.01062","DOI":"10.1109\/ICCV.2019.01062"},{"key":"2180_CR27","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1109\/TIP.2024.3357290","volume":"33","author":"Y Wang","year":"2024","unstructured":"Wang Y, Wei Y, Qian X, Zhu L, Yang Y. ReGO: Reference-Guided Outpainting for Scenery Image. IEEE Transactions on Image Processing. 2024;33:1375\u201388. https:\/\/doi.org\/10.1109\/TIP.2024.3357290","journal-title":"IEEE Transactions on Image Processing."},{"key":"2180_CR28","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1109\/83.585239","volume":"6","author":"F Sattar","year":"1997","unstructured":"Sattar F, Floreby L, Salomonsson G, Lovstrom B. Image enhancement based on a nonlinear multiscale method. IEEE Transactions on Image Processing. 1997;6:888\u201395. https:\/\/doi.org\/10.1109\/83.585239","journal-title":"IEEE Transactions on Image Processing."},{"key":"2180_CR29","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1109\/TIP.2013.2293423","volume":"23","author":"W Xue","year":"2014","unstructured":"Xue W, Zhang L, Mou X, Bovik AC. Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index. IEEE Transactions on Image Processing. 2014;23:684\u201395. https:\/\/doi.org\/10.1109\/TIP.2013.2293423","journal-title":"IEEE Transactions on Image Processing."}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02180-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-026-02180-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02180-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T19:10:15Z","timestamp":1786475415000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-026-02180-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,11]]},"references-count":29,"alternative-id":["2180"],"URL":"https:\/\/doi.org\/10.1007\/s10278-026-02180-y","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,11]]},"assertion":[{"value":"24 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Institutional Review Board of Seoul National University Hospital (IRB No. H-2208-005-1346).","order":1,"name":"Ethics","label":"Ethics Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived by the Institutional Review Board because of the retrospective study design.","order":2,"name":"Ethics","label":"Consent to Participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent for Publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Author Soyoung Chung and Author Hyeongmin Jin are spouses. This personal relationship did not influence the design,  conduct, analysis, interpretation, or reporting of the study. All other authors declare that they have no relevant financial or non financial interests to disclose.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}