{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T16:14:52Z","timestamp":1788192892145,"version":"build-2803163510"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"National Key Research and Development Program of China","award":["2024YFC2419300"],"award-info":[{"award-number":["2024YFC2419300"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82471967"],"award-info":[{"award-number":["82471967"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Hubei Provincial Key Research and Development Program","award":["2024BCB008"],"award-info":[{"award-number":["2024BCB008"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"DOI":"10.1007\/s10278-026-02214-5","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T15:25:13Z","timestamp":1788189913000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Deep Learning Algorithm\u2013Reconstructed Triple-Rule-Out CT: Image Quality and Performance in Evaluating Coronary Lumen Stenosis"],"prefix":"10.1007","author":[{"given":"Yu","family":"Du","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingyan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinhua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanjie","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youfa","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suping","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangxiang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0998-3800","authenticated-orcid":false,"given":"Qiuxia","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,31]]},"reference":[{"issue":"11","key":"2214_CR1","doi-asserted-by":"publisher","first-page":"543","DOI":"10.4070\/kcj.2010.40.11.543","volume":"40","author":"SM Yoo","year":"2010","unstructured":"Yoo SM, Rho JY, Lee HY, Song IS, Moon JY, White CS: Current concepts in cardiac CT angiography for patients with acute chest pain. Korean Circ J 40(11):543-9, 2010.","journal-title":"Korean Circ J"},{"issue":"3","key":"2214_CR2","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1016\/j.jcmg.2016.10.015","volume":"10","author":"GL Raff","year":"2017","unstructured":"Raff GL, Hoffmann U, Udelson JE: Trials of imaging use in the emergency department for acute chest pain. JACC Cardiovasc Imaging 10(3):338-349, 2017.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"3","key":"2214_CR3","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1148\/radiol.2019190829","volume":"293","author":"HJ Park","year":"2019","unstructured":"Park HJ, Son JH, Kim TB, Kang MK, Han K, Kim EH, Kim AY, Park SH: Relationship between lower dose and injection speed of iodinated contrast material for CT and acute hypersensitivity reactions: an observational study. Radiology 293(3):565-572, 2019.","journal-title":"Radiology"},{"issue":"2","key":"2214_CR4","doi-asserted-by":"publisher","first-page":"283","DOI":"10.2214\/AJR.22.28407","volume":"220","author":"GV Toia","year":"2023","unstructured":"Toia GV, Zamora DA, Singleton M, Liu A, Tan E, Leng S, Shuman WP, Kanal KM, Mileto A: Detectability of small low-attenuation lesions with deep learning CT image reconstruction: a 24-reader phantom study. AJR Am J Roentgenol 220(2):283-295, 2023.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2214_CR5","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1186\/s41747-024-00486-6","volume":"8","author":"Q Bellmann","year":"2024","unstructured":"Bellmann Q, Peng Y, Genske U, Yan L, Wagner M, Jahnke P: Low-contrast lesion detection in neck CT: a multireader study comparing deep learning, iterative, and filtered back projection reconstructions using realistic phantoms. Eur Radiol Exp 8(1):84, 2024.","journal-title":"Eur Radiol Exp"},{"issue":"12","key":"2214_CR6","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1016\/j.diii.2017.09.006","volume":"98","author":"S Si-Mohamed","year":"2017","unstructured":"Si-Mohamed S, Greffier J, Bobbia X, Larbi A, Delicque J, Khasanova E, Beregi JP, Macri F: Diagnostic performance of a low dose triple rule-out CT angiography using SAFIRE in emergency department. Diagn Interv Imaging 98(12):881-891, 2017.","journal-title":"Diagn Interv Imaging"},{"key":"2214_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.110736","volume":"161","author":"W Li","year":"2023","unstructured":"Li W, Lu H, Wen Y, Zhou M, Shuai T, You Y, Zhao J, Liao K, Lu C, Li J, Li Z, Diao K, He Y: Reducing both radiation and contrast doses for overweight patients in coronary CT angiography with 80-kVp and deep learning image reconstruction. Eur J Radiol 161:110736, 2023.","journal-title":"Eur J Radiol"},{"issue":"4","key":"2214_CR8","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1007\/s11547-023-01607-8","volume":"128","author":"D De Santis","year":"2023","unstructured":"De Santis D, Polidori T, Tremamunno G, Rucci C, Piccinni G, Zerunian M, Pugliese L, Del Gaudio A, Guido G, Barbato L, Laghi A, Caruso D: Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography. Radiol Med 128(4):434-444, 2023.","journal-title":"Radiol Med"},{"issue":"6","key":"2214_CR9","doi-asserted-by":"publisher","first-page":"2292","DOI":"10.1007\/s00330-016-4607-9","volume":"27","author":"RAP Takx","year":"2017","unstructured":"Takx RAP, Krissak R, Fink C, Bachmann V, Henzler T, Meyer M, Nance JW, Schoenberg SO, Apfaltrer P: Low-tube-voltage selection for triple-rule-out CTA: relation to patient size. Eur Radiol 27(6):2292-2297, 2017.","journal-title":"Eur Radiol"},{"issue":"11","key":"2214_CR10","doi-asserted-by":"publisher","first-page":"2647","DOI":"10.3390\/diagnostics12112647","volume":"12","author":"K Wang","year":"2022","unstructured":"Wang K, Wang X, Zheng S, Li C, Jin L, Li M: Dedicated CCTA followed by high-pitch scanning versus TRO-CT for contrast media and radiation dose reduction: a retrospective study. Diagnostics (Basel) 12(11):2647, 2022.","journal-title":"Diagnostics (Basel)"},{"issue":"5","key":"2214_CR11","doi-asserted-by":"publisher","first-page":"e651","DOI":"10.1016\/j.crad.2024.01.008","volume":"79","author":"Z Meng","year":"2024","unstructured":"Meng Z, Guo Y, Deng S, Xiang Q, Cao J, Zhang Y, Zhang K, Ma K, Xie S, Kang Z: Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a comparative study with standard-dose single-energy and dual-energy CT with adaptive statistical iterative reconstruction. Clin Radiol 79(5):e651-e658, 2024.","journal-title":"Clin Radiol"},{"issue":"4","key":"2214_CR12","doi-asserted-by":"publisher","first-page":"2213","DOI":"10.1007\/s00330-024-11059-x","volume":"35","author":"D Caruso","year":"2025","unstructured":"Caruso D, De Santis D, Tremamunno G, Santangeli C, Polidori T, Bona GG, Zerunian M, Del Gaudio A, Pugliese L, Laghi A: Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiography. Eur Radiol 35(4):2213-2221, 2025.","journal-title":"Eur Radiol"},{"key":"2214_CR13","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1016\/j.acra.2024.10.051","volume":"32","author":"PA Araoz","year":"2024","unstructured":"Araoz PA, Gadam S, Bhanushali AK, Sharma P, Singh M, Mullan AF, Collins JD, Young PM, Kopecky S, Clements CM: Triple rule out CT in the emergency department: clinical risk and outcomes (Triple Rule Out in the Emergency Department). Acad Radiol 32:1297-1305, 2024.","journal-title":"Acad Radiol"},{"issue":"6","key":"2214_CR14","doi-asserted-by":"publisher","first-page":"3832","DOI":"10.1007\/s00330-022-09287-0","volume":"33","author":"A Rossi","year":"2023","unstructured":"Rossi A, Gennari AG, Etter D, Benz DC, Sartoretti T, Giannopoulos AA, Mikail N, Bengs S, Maurer A, Gebhard C, Buechel RR, Kaufmann PA, Fuchs TA, Messerli M: Impact of deep learning image reconstructions (DLIR) on coronary artery calcium quantification. Eur Radiol 33(6):3832-3838, 2023.","journal-title":"Eur Radiol"},{"issue":"6","key":"2214_CR15","doi-asserted-by":"publisher","first-page":"2259","DOI":"10.1016\/j.acra.2024.03.020","volume":"31","author":"AC Klemenz","year":"2024","unstructured":"Klemenz AC, Beckert L, Manzke M, Lang CI, Weber MA, Meinel FG: Influence of deep learning based image reconstruction on quantitative results of coronary artery calcium scoring. Acad Radiol 31(6):2259-2267, 2024.","journal-title":"Acad Radiol"},{"key":"2214_CR16","doi-asserted-by":"publisher","first-page":"1881","DOI":"10.1007\/s10278-024-01234-3","volume":"38","author":"J Mei","year":"2024","unstructured":"Mei J, Chen C, Liu R, Ma H: Effect of deep learning image reconstruction on image quality and pericoronary fat attenuation index. J Imaging Inform Med 38:1881-1890, 2024.","journal-title":"J Imaging Inform Med"},{"issue":"11","key":"2214_CR17","doi-asserted-by":"publisher","first-page":"2505","DOI":"10.1016\/j.acra.2023.01.023","volume":"30","author":"T Nishii","year":"2023","unstructured":"Nishii T, Kobayashi T, Saito T, Kotoku A, Ohta Y, Kitahara S, Umehara K, Ota J, Horinouchi H, Morita Y, Noguchi T, Ishida T, Fukuda T: Deep learning-based post hoc CT denoising for the coronary perivascular fat attenuation index. Acad Radiol 30(11):2505-2513, 2023.","journal-title":"Acad Radiol"},{"issue":"5","key":"2214_CR18","doi-asserted-by":"publisher","first-page":"395.e17","DOI":"10.1016\/j.crad.2019.12.005","volume":"75","author":"WH Yin","year":"2020","unstructured":"Yin WH, Yu YT, Zhang Y, An YQ, Hou ZH, Gao Y, Wang HP, Lu B, De Santis D, Rollins JD, Schoepf UJ: Contrast medium injection protocols for coronary CT angiography: should contrast medium volumes be tailored to body weight or body surface area? Clin Radiol 75(5):395.e17-395.e24, 2020.","journal-title":"Clin Radiol"},{"issue":"2 Pt 1","key":"2214_CR19","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.jcmg.2019.04.017","volume":"13","author":"TM LaBounty","year":"2020","unstructured":"LaBounty TM: Reducing radiation dose in coronary computed tomography angiography: we are not there yet. JACC Cardiovasc Imaging 13(2 Pt 1):435\u2013436, 2020.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2214_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.110070","volume":"146","author":"M Wang","year":"2022","unstructured":"Wang M, Fan J, Shi X, Qin L, Yan F, Yang W: A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography. Eur J Radiol 146:110070, 2022.","journal-title":"Eur J Radiol"},{"issue":"3","key":"2214_CR21","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1007\/s00330-022-09146-y","volume":"33","author":"L Cao","year":"2023","unstructured":"Cao L, Liu X, Qu T, Cheng Y, Li J, Li Y, Chen L, Niu X, Tian Q, Guo J: Improving spatial resolution and diagnostic confidence with thinner slice and deep learning image reconstruction in contrast-enhanced abdominal CT. Eur Radiol 33(3):1603-1611, 2023.","journal-title":"Eur Radiol"},{"issue":"11","key":"2214_CR22","doi-asserted-by":"publisher","first-page":"4654","DOI":"10.1007\/s00330-018-5426-y","volume":"28","author":"Y Chen","year":"2018","unstructured":"Chen Y, Wang Q, Li J, Jia Y, Yang Q, He T: Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction. Eur Radiol 28(11):4654-4661, 2018.","journal-title":"Eur Radiol"},{"issue":"3","key":"2214_CR23","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1148\/radiol.2016151982","volume":"280","author":"K Higashigaito","year":"2016","unstructured":"Higashigaito K, Schmid T, Puippe G, Morsbach F, Lachat M, Seifert B, Pfammatter T, Alkadhi H, Husarik DB: CT angiography of the aorta: prospective evaluation of individualized low-volume contrast media protocols. Radiology 280(3):960-8, 2016.","journal-title":"Radiology"},{"issue":"1","key":"2214_CR24","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1148\/radiol.2461070307","volume":"246","author":"ST Schindera","year":"2008","unstructured":"Schindera ST, Nelson RC, Mukundan S Jr, Paulson EK, Jaffe TA, Miller CM, DeLong DM, Kawaji K, Yoshizumi TT, Samei E: Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study. Radiology 246(1):125-32, 2008.","journal-title":"Radiology"},{"issue":"4","key":"2214_CR25","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1016\/j.acra.2022.05.015","volume":"30","author":"Z Huang","year":"2023","unstructured":"Huang Z, Xiao J, Wang X, Li Z, Guo N, Hu Y, Li X, Wang X: Clinical evaluation of the automatic coronary artery disease reporting and data system (CAD-RADS) in coronary computed tomography angiography using convolutional neural networks. Acad Radiol 30(4):698-706, 2023.","journal-title":"Acad Radiol"},{"issue":"11","key":"2214_CR26","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1007\/s11547-020-01277-w","volume":"125","author":"M van Assen","year":"2020","unstructured":"van Assen M, Muscogiuri G, Caruso D, Lee SJ, Laghi A, De Cecco CN: Artificial intelligence in cardiac radiology. Radiol Med 125(11):1186-1199, 2020.","journal-title":"Radiol Med"},{"key":"2214_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111355","volume":"172","author":"H Chen","year":"2024","unstructured":"Chen H, Li Q, Zhou L, Li F: Deep learning-based algorithms for low-dose CT imaging: a review. Eur J Radiol 172:111355, 2024.","journal-title":"Eur J Radiol"},{"issue":"6","key":"2214_CR28","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.jcct.2016.10.002","volume":"10","author":"S Abbara","year":"2016","unstructured":"Abbara S, Blanke P, Maroules CD, Cheezum M, Choi AD, Han BK, Marwan M, Naoum C, Norgaard BL, Rubinshtein R, Schoenhagen P, Villines T, Leipsic J: SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: a report of the society of Cardiovascular Computed Tomography Guidelines Committee: endorsed by the North American Society for Cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr 10(6):435-449, 2016.","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"3","key":"2214_CR29","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1148\/radiol.2015151486","volume":"277","author":"RJ McDonald","year":"2015","unstructured":"McDonald RJ, McDonald JS, Newhouse JH, Davenport MS: Controversies in contrast material-induced acute kidney injury: closing in on the truth? Radiology 277(3):627-32, 2015.","journal-title":"Radiology"},{"issue":"12","key":"2214_CR30","doi-asserted-by":"publisher","first-page":"5384","DOI":"10.1007\/s00330-018-5678-6","volume":"28","author":"U Nyman","year":"2018","unstructured":"Nyman U, Ahlkvist J, Aspelin P, Brismar T, Frid A, Hellstr\u00f6m M, Liss P, Sterner G, Leander P: Preventing contrast medium-induced acute kidney injury : side-by-side comparison of Swedish-ESUR guidelines. Eur Radiol 28(12):5384-5395, 2018.","journal-title":"Eur Radiol"},{"key":"2214_CR31","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2020.105651","volume":"196","author":"D Han","year":"2020","unstructured":"Han D, Liu J, Sun Z, Cui Y, He Y, Yang Z: Deep learning analysis in coronary computed tomographic angiography imaging for the assessment of patients with coronary artery stenosis. Comput Methods Programs Biomed 196:105651, 2020.","journal-title":"Comput Methods Programs Biomed"},{"issue":"6","key":"2214_CR32","doi-asserted-by":"publisher","first-page":"1839","DOI":"10.1007\/s00261-024-04246-3","volume":"49","author":"HU Choi","year":"2024","unstructured":"Choi HU, Cho J, Hwang J, Lee S, Chang W, Park JH, Lee KH: Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis. Abdom Radiol (NY) 49(6):1839-1849, 2024.","journal-title":"Abdom Radiol (NY)"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02214-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-026-02214-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02214-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T15:25:14Z","timestamp":1788189914000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-026-02214-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,31]]},"references-count":32,"alternative-id":["2214"],"URL":"https:\/\/doi.org\/10.1007\/s10278-026-02214-5","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,31]]},"assertion":[{"value":"26 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This prospective study was approved by our hospital\u2019s ethics committee (IRB: TJ-IRB02402012). All participants provided written informed consent before imaging.","order":1,"name":"Ethics","label":"Ethics Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors of this manuscript declare relationships with the following companies: GE Healthcare China for Suping Chen and Xiangxiang Chen. The other authors have no potential conflicts of interest to disclose.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}