{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T16:14:32Z","timestamp":1788192872448,"version":"build-2803163510"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aims to evaluate the clinical performance and operational reliability of a fully automated, vendor-neutral imaging informatics pipeline for fetal MRI slice-to-volume reconstruction using open-source Medical Open Network for Artificial Intelligence (MONAI) Deploy Express, DICOM routing, and PACS return. In this retrospective implementation study, consecutive singleton fetal MRI examinations performed at a tertiary fetal care center between October and December 2025 were processed using a MONAI Deploy Express pipeline triggered by DICOM routing. The pipeline performed automated series selection and motion-corrected SVR reconstruction for fetal brain and body imaging using routine single-shot fast spin-echo inputs. Reconstructed volumes were returned to PACS for radiologist review. Three fellowship-trained fetal radiologists independently scored reconstruction quality using a 5-point Likert scale. Primary outcomes included examination-level reconstruction acceptability, inter-reader reliability, failure modes, and operational time to PACS availability after transition to the finalized production workflow. Among 67 triggered examinations, 2 represented technical workflow events and were excluded from clinical performance analysis, leaving 65 examinations for image-quality evaluation. Mean gestational age was 28.9\u00a0weeks (range, 19\u201336\u00a0weeks) and most fetuses had structural abnormalities. Brain SVR was rated pass-or-higher in 59\/65 examinations (90.8%) and body SVR was rated pass-or-higher in 57\/65 examinations (87.7%). Inter-reader reliability was excellent for brain (ICC, 0.93) and body (ICC, 0.92) reconstruction quality assessments. Reconstruction failures were primarily associated with suboptimal or insufficient input stacks, severe fetal motion, amniotic fluid extremes, complex anatomic distortions, and early gestational age. In 57 consecutively processed examinations after finalized production integration, median time to PACS availability was 10\u00a0min 28\u00a0s for brain SVR and 11\u00a0min 50\u00a0s for body SVR. Automated fetal MRI SVR was operationally feasible using a DICOM-based, vendor-neutral deployment architecture integrated with routine PACS workflow. In this single-center, single-vendor cohort, the pipeline returned radiologist-acceptable reconstructions within a clinically practical timeframe. Multi-vendor and comparative reader studies are needed to establish geometric accuracy, generalizability, and diagnostic benefit.<\/jats:p>","DOI":"10.1007\/s10278-026-02228-z","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T15:21:15Z","timestamp":1788189675000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Implementation and Validation of Automated Slice-to-Volume Reconstruction for Fetal MRI Using a Vendor-Neutral MONAI-Based Imaging Informatics Pipeline"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1682-7833","authenticated-orcid":false,"given":"Jungwhan John","family":"Choi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryan","family":"Luna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Clark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander J.","family":"Towbin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Usha D.","family":"Nagaraj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beth M.","family":"Kline-Fath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan R.","family":"Dillman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elanchezhian","family":"Somasundaram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,31]]},"reference":[{"key":"2228_CR1","doi-asserted-by":"publisher","unstructured":"Jaimes C, Choi JJ. Fetal MR Imaging. Magn Reson Imaging Clin N Am. 2024;32(3):xv\u2013xvi. Epub 20240417. https:\/\/doi.org\/10.1016\/j.mric.2024.03.007. PubMed PMID: 38944443.","DOI":"10.1016\/j.mric.2024.03.007"},{"key":"2228_CR2","doi-asserted-by":"publisher","unstructured":"Tavares de Sousa M, Schonnagel BP, Denecke J, Herrmann J. Prenatal imaging - role of fetal MRI. Rofo. 2025;197(4):385\u201396. Epub 20241206. https:\/\/doi.org\/10.1055\/a-2357-6997. PubMed PMID: 39642925.","DOI":"10.1055\/a-2357-6997"},{"key":"2228_CR3","doi-asserted-by":"publisher","unstructured":"Malamateniou C, Malik SJ, Counsell SJ, Allsop JM, McGuinness AK, Hayat T, et al. Motion-compensation techniques in neonatal and fetal MR imaging. AJNR Am J Neuroradiol. 2013;34(6):1124\u201336. Epub 20120510. https:\/\/doi.org\/10.3174\/ajnr.A3128. PubMed PMID: 22576885; PubMed Central PMCID: PMC7964586.","DOI":"10.3174\/ajnr.A3128"},{"issue":"7","key":"2228_CR4","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1109\/TMI.2007.895456","volume":"26","author":"S Jiang","year":"2007","unstructured":"Jiang S, Xue H, Glover A, Rutherford M, Rueckert D, Hajnal JV. MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): application to fetal, neonatal, and adult brain studies. IEEE Trans Med Imaging. 2007;26(7):967\u201380. https:\/\/doi.org\/10.1109\/TMI.2007.895456. PubMed PMID: 17649910.","journal-title":"IEEE Trans Med Imaging."},{"key":"2228_CR5","doi-asserted-by":"publisher","unstructured":"Uus A, Neves Silva S, Aviles Verdera J, Payette K, Hall M, Colford K, et al. Scanner-based real-time three-dimensional brain + body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging. Pediatr Radiol. 2025;55(3):556\u201369. Epub 20250124. https:\/\/doi.org\/10.1007\/s00247-025-06165-x. PubMed PMID: 39853394; PubMed Central PMCID: PMC11882667.","DOI":"10.1007\/s00247-025-06165-x"},{"key":"2228_CR6","doi-asserted-by":"publisher","unstructured":"Uus A, Zhang T, Jackson LH, Roberts TA, Rutherford MA, Hajnal JV, et al. Deformable Slice-to-Volume Registration for Motion Correction of Fetal Body and Placenta MRI. IEEE Trans Med Imaging. 2020;39(9):2750\u20139. Epub 20200218. https:\/\/doi.org\/10.1109\/TMI.2020.2974844. PubMed PMID: 32086200; PubMed Central PMCID: PMC7116020.","DOI":"10.1109\/TMI.2020.2974844"},{"key":"2228_CR7","doi-asserted-by":"publisher","unstructured":"Uus AU, Hall M, Grigorescu I, Zampieri CA, Collado AE, Payette K, et al. 3D T2w fetal body MRI: automated organ volumetry, growth charts and population-averaged atlas. medRxiv. 2023. Epub 20230918. https:\/\/doi.org\/10.1101\/2023.05.31.23290751. PubMed PMID: 37398121; PubMed Central PMCID: PMC10312818.","DOI":"10.1101\/2023.05.31.23290751"},{"key":"2228_CR8","doi-asserted-by":"publisher","unstructured":"Xu J, Moyer D, Gagoski B, Iglesias JE, Grant PE, Golland P, et al. NeSVoR: Implicit Neural Representation for Slice-to-Volume Reconstruction in MRI. IEEE Trans Med Imaging. 2023;42(6):1707\u201319. Epub 20230601. https:\/\/doi.org\/10.1109\/TMI.2023.3236216. PubMed PMID: 37018704; PubMed Central PMCID: PMC10287191.","DOI":"10.1109\/TMI.2023.3236216"},{"key":"2228_CR9","doi-asserted-by":"publisher","unstructured":"Nagaraj UD, Greer JS, Debnath P, Tkach JA, Kline-Fath BM. Slice-to-Volume Reconstruction of Fetal Brain MR Imaging in Clinical Practice. AJNR Am J Neuroradiol. 2025;46(8):1726\u201330. Epub 20250801. https:\/\/doi.org\/10.3174\/ajnr.A8728. PubMed PMID: 40639972; PubMed Central PMCID: PMC12453519.","DOI":"10.3174\/ajnr.A8728"},{"key":"2228_CR10","doi-asserted-by":"publisher","unstructured":"Selected Abstracts from the 2025 Conference on Artificial Intelligence in Medical Imaging (CAIMI) of the Society for Imaging Informatics in Medicine (SIIM). J Imaging Inform Med. 2025;38(Suppl 2):51\u201377. https:\/\/doi.org\/10.1007\/s10278-025-01679-0. PubMed PMID: 41214242; PubMed Central PMCID: PMC12705894.","DOI":"10.1007\/s10278-025-01679-0"},{"key":"2228_CR11","doi-asserted-by":"publisher","unstructured":"Gupta V, Erdal B, Ramirez C, Floca R, Genereaux B, Bryson S, et al. Current State of Community-Driven Radiological AI Deployment in Medical Imaging. JMIR AI. 2024;3:e55833. Epub 20241209. https:\/\/doi.org\/10.2196\/55833. PubMed PMID: 39653370; PubMed Central PMCID: PMC11667144.","DOI":"10.2196\/55833"},{"key":"2228_CR12","doi-asserted-by":"publisher","unstructured":"Kuklisova-Murgasova M, Quaghebeur G, Rutherford MA, Hajnal JV, Schnabel JA. Reconstruction of fetal brain MRI with intensity matching and complete outlier removal. Med Image Anal. 2012;16(8):1550\u201364. Epub 20120809. https:\/\/doi.org\/10.1016\/j.media.2012.07.004. PubMed PMID: 22939612; PubMed Central PMCID: PMC4067058.","DOI":"10.1016\/j.media.2012.07.004"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02228-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-026-02228-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-026-02228-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T15:21:16Z","timestamp":1788189676000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-026-02228-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,31]]},"references-count":12,"alternative-id":["2228"],"URL":"https:\/\/doi.org\/10.1007\/s10278-026-02228-z","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,31]]},"assertion":[{"value":"23 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was approved by the institutional review board with waiver of informed consent.","order":1,"name":"Ethics","label":"Ethics Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was waived by the institutional review board because of the retrospective nature of the study.","order":2,"name":"Ethics","label":"Consent to Participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. The manuscript does not include identifiable patient information.","order":3,"name":"Ethics","label":"Consent for Publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}