{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T04:28:31Z","timestamp":1768278511730,"version":"3.49.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2018,3,16]],"date-time":"2018-03-16T00:00:00Z","timestamp":1521158400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,3,16]],"date-time":"2018-03-16T00:00:00Z","timestamp":1521158400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["25461806"],"award-info":[{"award-number":["25461806"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["17K10395"],"award-info":[{"award-number":["17K10395"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"published-print":{"date-parts":[[2018,8]]},"DOI":"10.1007\/s10334-018-0681-0","type":"journal-article","created":{"date-parts":[[2018,3,16]],"date-time":"2018-03-16T11:19:57Z","timestamp":1521199197000},"page":"577-584","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of retained products of conception using pulsed continuous arterial spin-labeling MRI: clinical feasibility and initial results"],"prefix":"10.1007","volume":"31","author":[{"given":"Nobuyuki","family":"Kosaka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiro","family":"Fujiwara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuji","family":"Kurokawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsuyoshi","family":"Matsuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayuki","family":"Kanamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoyuki","family":"Takei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Takata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshio","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirohiko","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,3,16]]},"reference":[{"issue":"1","key":"681_CR1","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1002\/mrm.25197","volume":"73","author":"DC Alsop","year":"2015","unstructured":"Alsop DC, Detre JA, Golay X, Gunther M, Hendrikse J, Hernandez-Garcia L, Lu H, MacIntosh BJ, Parkes LM, Smits M, van Osch MJ, Wang DJ, Wong EC, Zaharchuk G (2015) Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. Magn Reson Med 73(1):102\u2013116","journal-title":"Magn Reson Med"},{"issue":"2","key":"681_CR2","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1002\/jmri.20382","volume":"22","author":"H Kimura","year":"2005","unstructured":"Kimura H, Kado H, Koshimoto Y, Tsuchida T, Yonekura Y, Itoh H (2005) Multislice continuous arterial spin-labeled perfusion MRI in patients with chronic occlusive cerebrovascular disease: a correlative study with CO2 PET validation. J Magn Reson Imaging 22(2):189\u2013198","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"681_CR3","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1148\/radiol.12112260","volume":"265","author":"RS Lanzman","year":"2012","unstructured":"Lanzman RS, Robson PM, Sun MR, Patel AD, Mentore K, Wagner AA, Genega EM, Rofsky NM, Alsop DC, Pedrosa I (2012) Arterial spin-labeling MR imaging of renal masses: correlation with histopathologic findings. Radiology 265(3):799\u2013808","journal-title":"Radiology"},{"issue":"1","key":"681_CR4","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1111\/jog.12128","volume":"40","author":"K Hiraki","year":"2014","unstructured":"Hiraki K, Khan KN, Kitajima M, Fujishita A, Masuzaki H (2014) Uterine preservation surgery for placental polyp. J Obstet Gynaecol Res 40(1):89\u201395","journal-title":"J Obstet Gynaecol Res"},{"issue":"2","key":"681_CR5","doi-asserted-by":"publisher","first-page":"e9","DOI":"10.1016\/j.ajog.2011.01.070","volume":"205","author":"K Marques","year":"2011","unstructured":"Marques K, Looney C, Hayslip C, Gavrilova-Jordan L (2011) Modern management of hypervascular placental polypoid mass following spontaneous abortion: a case report and literature review. Am J Obstet Gynecol 205(2):e9\u201311","journal-title":"Am J Obstet Gynecol"},{"issue":"5","key":"681_CR6","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1148\/rg.295085242","volume":"29","author":"KM Elsayes","year":"2009","unstructured":"Elsayes KM, Trout AT, Friedkin AM, Liu PS, Bude RO, Platt JF, Menias CO (2009) Imaging of the placenta: a multimodality pictorial review. Radiographics 29(5):1371\u20131391","journal-title":"Radiographics"},{"issue":"3","key":"681_CR7","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1007\/s00261-012-9929-8","volume":"38","author":"G Masselli","year":"2013","unstructured":"Masselli G, Gualdi G (2013) MR imaging of the placenta: what a radiologist should know. Abdom Imaging 38(3):573\u2013587","journal-title":"Abdom Imaging"},{"issue":"1","key":"681_CR8","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1007\/s00261-010-9604-x","volume":"36","author":"J Takahama","year":"2011","unstructured":"Takahama J, Kitano S, Marugami N, Uehara T, Takahashi A, Takewa M, Itoh T, Kichikawa K (2011) Retained placental tissue: role of MRI findings in diagnosis and clinical assessment. Abdom Imaging 36(1):110\u2013114","journal-title":"Abdom Imaging"},{"issue":"3","key":"681_CR9","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1002\/mrm.1910400318","volume":"40","author":"PA Gowland","year":"1998","unstructured":"Gowland PA, Francis ST, Duncan KR, Freeman AJ, Issa B, Moore RJ, Bowtell RW, Baker PN, Johnson IR, Worthington BS (1998) In vivo perfusion measurements in the human placenta using echo planar imaging at 0.5 T. Magn Reson Med 40(3):467\u2013473","journal-title":"Magn Reson Med"},{"issue":"1","key":"681_CR10","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1186\/s40064-016-3596-0","volume":"5","author":"N Takahashi","year":"2016","unstructured":"Takahashi N, Yoshino O, Hiraike O, Maeda E, Nakamura M, Hori M, Harada M, Koga K, Saito S, Fujii T, Osuga Y (2016) The assessment of myometrium perfusion in patients with uterine fibroid by arterial spin labeling MRI. Springerplus 5(1):190","journal-title":"Springerplus"},{"issue":"6","key":"681_CR11","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1002\/mrm.21790","volume":"60","author":"W Dai","year":"2008","unstructured":"Dai W, Garcia D, de Bazelaire C, Alsop DC (2008) Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 60(6):1488\u20131497","journal-title":"Magn Reson Med"},{"issue":"5","key":"681_CR12","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1002\/mrm.23103","volume":"67","author":"W Dai","year":"2012","unstructured":"Dai W, Robson PM, Shankaranarayanan A, Alsop DC (2012) Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging. Magn Reson Med 67(5):1252\u20131265","journal-title":"Magn Reson Med"},{"issue":"7","key":"681_CR13","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1016\/j.mri.2013.03.024","volume":"31","author":"SH Park","year":"2013","unstructured":"Park SH, Wang DJ, Duong TQ (2013) Balanced steady state free precession for arterial spin labeling MRI: initial experience for blood flow mapping in human brain, retina, and kidney. Magn Reson Imaging 31(7):1044\u20131050","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"681_CR14","doi-asserted-by":"crossref","first-page":"204798161351016","DOI":"10.1177\/2047981613510160","volume":"3","author":"K Shimizu","year":"2014","unstructured":"Shimizu K, Kosaka N, Yamamoto T, Shioura H, Kodera T, Kikuta K, Kimura H (2014) Arterial spin labeling perfusion-weighted MRI for long-term follow-up of a cerebral arteriovenous malformation after stereotactic radiosurgery. Acta Radiol Short Rep 3(1):2047981613510160","journal-title":"Acta Radiol Short Rep"},{"issue":"10","key":"681_CR15","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1016\/j.placenta.2013.07.006","volume":"34","author":"I Derwig","year":"2013","unstructured":"Derwig I, Lythgoe DJ, Barker GJ, Poon L, Gowland P, Yeung R, Zelaya F, Nicolaides K (2013) Association of placental perfusion, as assessed by magnetic resonance imaging and uterine artery Doppler ultrasound, and its relationship to pregnancy outcome. Placenta 34(10):885\u2013891","journal-title":"Placenta"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10334-018-0681-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-018-0681-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-018-0681-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T19:25:56Z","timestamp":1589657156000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10334-018-0681-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,16]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["681"],"URL":"https:\/\/doi.org\/10.1007\/s10334-018-0681-0","relation":{},"ISSN":["0968-5243","1352-8661"],"issn-type":[{"value":"0968-5243","type":"print"},{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,16]]},"assertion":[{"value":"25 October 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 March 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Matsuda and Takei are employees of GE Healthcare Japan Corporation and worked on ASL-MRI sequence development.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}