{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:40:43Z","timestamp":1789015243613,"version":"build-2803163510"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T00:00:00Z","timestamp":1620086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T00:00:00Z","timestamp":1620086400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100014535","name":"Center for Individualized Medicine, Mayo Clinic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014535","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>MR fingerprinting (MRF) is a MR technique that allows assessment of tissue relaxation times. The purpose of this study is to evaluate the clinical application of this technique in patients with meningioma.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>A whole-brain 3D isotropic 1mm<jats:sup>3<\/jats:sup> acquisition under a 3.0T field strength was used to obtain MRF T<jats:sub>1<\/jats:sub> and T<jats:sub>2<\/jats:sub>-based relaxometry values in 4:38\u00a0s. The accuracy of values was quantified by scanning a quantitative MR relaxometry phantom. In vivo evaluation was performed by applying the sequence to 20 subjects with 25 meningiomas. Regions of interest included the meningioma, caudate head, centrum semiovale, contralateral white matter and thalamus. For both phantom and subjects, mean values of both T<jats:sub>1<\/jats:sub> and T<jats:sub>2<\/jats:sub> estimates were obtained. Statistical significance of differences in mean values between the meningioma and other brain structures was tested using a Friedman\u2019s ANOVA test.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>MR fingerprinting phantom data demonstrated a linear relationship between measured and reference relaxometry estimates for both T<jats:sub>1<\/jats:sub> (<jats:italic>r<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u20090.99) and T<jats:sub>2<\/jats:sub> (<jats:italic>r<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u20090.97). MRF T<jats:sub>1<\/jats:sub> relaxation times were longer in meningioma (mean\u2009\u00b1\u2009SD 1429\u2009\u00b1\u2009202\u00a0ms) compared to thalamus (mean\u2009\u00b1\u2009SD 1054\u2009\u00b1\u200958\u00a0ms; <jats:italic>p<\/jats:italic>\u2009=\u20090.004), centrum semiovale (mean\u2009\u00b1\u2009SD 825\u2009\u00b1\u200942\u00a0ms; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and contralateral white matter (mean\u2009\u00b1\u2009SD 799\u2009\u00b1\u200940\u00a0ms; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). MRF T<jats:sub>2<\/jats:sub> relaxation times were longer for meningioma (mean\u2009\u00b1\u2009SD 69\u2009\u00b1\u200927\u00a0ms) as compared to thalamus (mean\u2009\u00b1\u2009SD 27\u2009\u00b1\u20093\u00a0ms; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), caudate head (mean\u2009\u00b1\u2009SD 39\u2009\u00b1\u20095\u00a0ms; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and contralateral white matter (mean\u2009\u00b1\u2009SD 35\u2009\u00b1\u20094\u00a0ms; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001)<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Phantom measurements indicate that the proposed 3D-MRF sequence relaxometry estimations are valid and reproducible. For in vivo, entire brain coverage was obtained in clinically feasible time and allows quantitative assessment of meningioma in clinical practice.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10334-021-00924-1","type":"journal-article","created":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T05:03:00Z","timestamp":1620104580000},"page":"697-706","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Whole-brain 3D MR fingerprinting brain imaging: clinical validation and feasibility to patients with meningioma"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7230-763X","authenticated-orcid":false,"given":"Thomaz R.","family":"Mostardeiro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ananya","family":"Panda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Witte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norbert G.","family":"Campeau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiaran P.","family":"McGee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Sui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aiming","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,5,4]]},"reference":[{"key":"924_CR1","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.cobme.2017.11.001","volume":"3","author":"A Panda","year":"2017","unstructured":"Panda A, Mehta BB, Coppo S, Jiang Y, Ma D, Seiberlich N, Griswold MA, Gulani V (2017) Magnetic resonance fingerprinting\u2014an overview. Curr Opin Biomed Eng 3:56\u201366. https:\/\/doi.org\/10.1016\/j.cobme.2017.11.001","journal-title":"Curr Opin Biomed Eng"},{"issue":"6","key":"924_CR2","doi-asserted-by":"publisher","first-page":"1621","DOI":"10.1002\/mrm.25559","volume":"74","author":"Y Jiang","year":"2015","unstructured":"Jiang Y, Ma D, Seiberlich N, Gulani V, Griswold MA (2015) MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout. Magn Reson Med 74(6):1621\u20131631. https:\/\/doi.org\/10.1002\/mrm.25559","journal-title":"Magn Reson Med"},{"issue":"7440","key":"924_CR3","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1038\/nature11971","volume":"495","author":"D Ma","year":"2013","unstructured":"Ma D, Gulani V, Seiberlich N, Liu K, Sunshine JL, Duerk JL, Griswold MA (2013) Magnetic resonance fingerprinting. Nature 495(7440):187\u2013192. https:\/\/doi.org\/10.1038\/nature11971","journal-title":"Nature"},{"issue":"1","key":"924_CR4","doi-asserted-by":"publisher","first-page":"8468","DOI":"10.1038\/s41598-019-44832-w","volume":"9","author":"PA G\u00f3mez","year":"2019","unstructured":"G\u00f3mez PA, Molina-Romero M, Buonincontri G, Menzel MI, Menze BH (2019) Designing contrasts for rapid, simultaneous parameter quantification and flow visualization with quantitative transient-state imaging. Sci Rep 9(1):8468. https:\/\/doi.org\/10.1038\/s41598-019-44832-w","journal-title":"Sci Rep"},{"issue":"5","key":"924_CR5","doi-asserted-by":"publisher","first-page":"2606","DOI":"10.1002\/mrm.28301","volume":"84","author":"JW Kurzawski","year":"2020","unstructured":"Kurzawski JW, Cencini M, Peretti L, G\u00f3mez PA, Schulte RF, Donatelli G, Cosottini M, Cecchi P, Costagli M, Retico A, Tosetti M, Buonincontri G (2020) Retrospective rigid motion correction of three-dimensional magnetic resonance fingerprinting of the human brain. Magn Reson Med 84(5):2606\u20132615. https:\/\/doi.org\/10.1002\/mrm.28301","journal-title":"Magn Reson Med"},{"issue":"4","key":"924_CR6","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1002\/mrm.26886","volume":"79","author":"D Ma","year":"2018","unstructured":"Ma D, Jiang Y, Chen Y, McGivney D, Mehta B, Gulani V, Griswold M (2018) Fast 3D magnetic resonance fingerprinting for a whole-brain coverage. Magn Reson Med 79(4):2190\u20132197. https:\/\/doi.org\/10.1002\/mrm.26886","journal-title":"Magn Reson Med"},{"issue":"5","key":"924_CR7","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1002\/jmri.26319","volume":"49","author":"D Ma","year":"2019","unstructured":"Ma D, Jones SE, Deshmane A, Sakaie K, Pierre EY, Larvie M, McGivney D, Bl\u00fcmcke I, Krishnan B, Lowe M, Gulani V, Najm I, Griswold MA, Wang ZI (2019) Development of high-resolution 3D MR fingerprinting for detection and characterization of epileptic lesions. J Magn Reson Imaging 49(5):1333\u20131346. https:\/\/doi.org\/10.1002\/jmri.26319","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"924_CR8","doi-asserted-by":"publisher","first-page":"2303","DOI":"10.1002\/mrm.25818","volume":"75","author":"D Ma","year":"2016","unstructured":"Ma D, Pierre EY, Jiang Y, Schluchter MD, Setsompop K, Gulani V, Griswold MA (2016) Music-based magnetic resonance fingerprinting to improve patient comfort during MRI examinations. Magn Reson Med 75(6):2303\u20132314. https:\/\/doi.org\/10.1002\/mrm.25818","journal-title":"Magn Reson Med"},{"issue":"1","key":"924_CR9","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1002\/mrm.27726","volume":"82","author":"X Cao","year":"2019","unstructured":"Cao X, Ye H, Liao C, Li Q, He H, Zhong J (2019) Fast 3D brain MR fingerprinting based on multi-axis spiral projection trajectory. Magn Reson Med 82(1):289\u2013301. https:\/\/doi.org\/10.1002\/mrm.27726","journal-title":"Magn Reson Med"},{"key":"924_CR10","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27134","author":"J Asslander","year":"2020","unstructured":"Asslander J (2020) A Perspective on MR Fingerprinting. J Magn Reson Imaging. https:\/\/doi.org\/10.1002\/jmri.27134","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"924_CR11","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1002\/jmri.26836","volume":"51","author":"ME Poorman","year":"2020","unstructured":"Poorman ME, Martin MN, Ma D, McGivney DF, Gulani V, Griswold MA, Keenan KE (2020) Magnetic resonance fingerprinting Part 1: Potential uses, current challenges, and recommendations. J Magn Reson Imaging 51(3):675\u2013692. https:\/\/doi.org\/10.1002\/jmri.26836","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"924_CR12","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1002\/jmri.26717","volume":"50","author":"A Panda","year":"2019","unstructured":"Panda A, Chen Y, Ropella-Panagis K, Ghodasara S, Stopchinski M, Seyfried N, Wright K, Seiberlich N, Griswold M, Gulani V (2019) Repeatability and reproducibility of 3D MR fingerprinting relaxometry measurements in normal breast tissue. J Magn Reson Imaging 50(4):1133\u20131143. https:\/\/doi.org\/10.1002\/jmri.26717","journal-title":"J Magn Reson Imaging"},{"issue":"8","key":"924_CR13","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1097\/RLI.0000000000000569","volume":"54","author":"A Panda","year":"2019","unstructured":"Panda A, O\u2019Connor G, Lo WC, Jiang Y, Margevicius S, Schluchter M, Ponsky LE, Gulani V (2019) Targeted biopsy validation of peripheral zone prostate cancer characterization with magnetic resonance fingerprinting and diffusion mapping. Invest Radiol 54(8):485\u2013493. https:\/\/doi.org\/10.1097\/RLI.0000000000000569","journal-title":"Invest Radiol"},{"issue":"4","key":"924_CR14","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1002\/jmri.26877","volume":"51","author":"DF McGivney","year":"2020","unstructured":"McGivney DF, Boyacioglu R, Jiang Y, Poorman ME, Seiberlich N, Gulani V, Keenan KE, Griswold MA, Ma D (2020) Magnetic resonance fingerprinting review part 2: technique and directions. J Magn Reson Imaging 51(4):993\u20131007. https:\/\/doi.org\/10.1002\/jmri.26877","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"924_CR15","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1002\/mrm.26509","volume":"78","author":"Y Jiang","year":"2017","unstructured":"Jiang Y, Ma D, Keenan KE, Stupic KF, Gulani V, Griswold MA (2017) Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM\/NIST MRI system phantom. Magn Reson Med 78(4):1452\u20131457. https:\/\/doi.org\/10.1002\/mrm.26509","journal-title":"Magn Reson Med"},{"key":"924_CR16","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.mri.2017.06.014","volume":"41","author":"T Amthor","year":"2017","unstructured":"Amthor T, Doneva M, Koken P, Sommer K, Meineke J, Bornert P (2017) Magnetic resonance fingerprinting with short relaxation intervals. Magn Reson Imaging 41:22\u201328. https:\/\/doi.org\/10.1016\/j.mri.2017.06.014","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"924_CR17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1148\/radiol.2018180836","volume":"290","author":"Y Chen","year":"2019","unstructured":"Chen Y, Panda A, Pahwa S, Hamilton JI, Dastmalchian S, McGivney DF, Ma D, Batesole J, Seiberlich N, Griswold MA, Plecha D, Gulani V (2019) Three-dimensional MR fingerprinting for quantitative breast imaging. Radiology 290(1):33\u201340. https:\/\/doi.org\/10.1148\/radiol.2018180836","journal-title":"Radiology"},{"issue":"3","key":"924_CR18","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1148\/radiol.2019181705","volume":"292","author":"A Panda","year":"2019","unstructured":"Panda A, Obmann VC, Lo WC, Margevicius S, Jiang Y, Schluchter M, Patel IJ, Nakamoto D, Badve C, Griswold MA, Jaeger I, Ponsky LE, Gulani V (2019) MR fingerprinting and ADC mapping for characterization of lesions in the transition zone of the prostate gland. Radiology 292(3):685\u2013694. https:\/\/doi.org\/10.1148\/radiol.2019181705","journal-title":"Radiology"},{"issue":"10","key":"924_CR19","doi-asserted-by":"publisher","first-page":"e4370","DOI":"10.1002\/nbm.4370","volume":"33","author":"G Cruz","year":"2020","unstructured":"Cruz G, Jaubert O, Qi H, Bustin A, Milotta G, Schneider T, Koken P, Doneva M, Botnar RM, Prieto C (2020) 3D free-breathing cardiac magnetic resonance fingerprinting. NMR Biomed 33(10):e4370. https:\/\/doi.org\/10.1002\/nbm.4370","journal-title":"NMR Biomed"},{"issue":"2","key":"924_CR20","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1148\/radiol.2019182360","volume":"292","author":"G Korzdorfer","year":"2019","unstructured":"Korzdorfer G, Kirsch R, Liu K, Pfeuffer J, Hensel B, Jiang Y, Ma D, Gratz M, Bar P, Bogner W, Springer E, Lima Cardoso P, Umutlu L, Trattnig S, Griswold M, Gulani V, Nittka M (2019) Reproducibility and repeatability of MR fingerprinting relaxometry in the human brain. Radiology 292(2):429\u2013437. https:\/\/doi.org\/10.1148\/radiol.2019182360","journal-title":"Radiology"},{"key":"924_CR21","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.neuroimage.2019.03.047","volume":"195","author":"G Buonincontri","year":"2019","unstructured":"Buonincontri G, Biagi L, Retico A, Cecchi P, Cosottini M, Gallagher FA, Gomez PA, Graves MJ, McLean MA, Riemer F, Schulte RF, Tosetti M, Zaccagna F, Kaggie JD (2019) Multi-site repeatability and reproducibility of MR fingerprinting of the healthy brain at 1.5 and 3.0T. Neuroimage 195:362\u2013372. https:\/\/doi.org\/10.1016\/j.neuroimage.2019.03.047","journal-title":"Neuroimage"},{"issue":"9","key":"924_CR22","doi-asserted-by":"publisher","first-page":"1639","DOI":"10.1002\/acn3.50851","volume":"6","author":"K Wang","year":"2019","unstructured":"Wang K, Cao X, Wu D, Liao C, Zhang J, Ji C, Zhong J, He H, Chen Y (2019) Magnetic resonance fingerprinting of temporal lobe white matter in mesial temporal lobe epilepsy. Ann Clin Transl Neurol 6(9):1639\u20131646. https:\/\/doi.org\/10.1002\/acn3.50851","journal-title":"Ann Clin Transl Neurol"},{"issue":"3","key":"924_CR23","doi-asserted-by":"publisher","first-page":"492","DOI":"10.3174\/ajnr.A5035","volume":"38","author":"C Badve","year":"2017","unstructured":"Badve C, Yu A, Dastmalchian S, Rogers M, Ma D, Jiang Y, Margevicius S, Pahwa S, Lu Z, Schluchter M, Sunshine J, Griswold M, Sloan A, Gulani V (2017) MR fingerprinting of adult brain tumors: initial experience. AJNR Am J Neuroradiol 38(3):492\u2013499. https:\/\/doi.org\/10.3174\/ajnr.A5035","journal-title":"AJNR Am J Neuroradiol"},{"issue":"5","key":"924_CR24","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1159\/000501696","volume":"54","author":"P de Blank","year":"2019","unstructured":"de Blank P, Badve C, Gold DR, Stearns D, Sunshine J, Dastmalchian S, Tomei K, Sloan AE, Barnholtz-Sloan JS, Lane A, Griswold M, Gulani V, Ma D (2019) Magnetic resonance fingerprinting to characterize childhood and young adult brain tumors. Pediatr Neurosurg 54(5):310\u2013318. https:\/\/doi.org\/10.1159\/000501696","journal-title":"Pediatr Neurosurg"},{"issue":"3","key":"924_CR25","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1002\/mp.13967","volume":"47","author":"L Lu","year":"2020","unstructured":"Lu L, Chen Y, Shen C, Lian J, Das S, Marks L, Lin W, Zhu T (2020) Initial assessment of 3D magnetic resonance fingerprinting (MRF) towards quantitative brain imaging for radiation therapy. Med Phys 47(3):1199\u20131214. https:\/\/doi.org\/10.1002\/mp.13967","journal-title":"Med Phys"},{"key":"924_CR26","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27381","author":"B Marty","year":"2020","unstructured":"Marty B, Lopez Kolkovsky AL, Araujo ECA, Reyngoudt H (2020) Quantitative skeletal muscle imaging using 3D MR fingerprinting with water and fat separation. J Magn Reson Imaging. https:\/\/doi.org\/10.1002\/jmri.27381","journal-title":"J Magn Reson Imaging"},{"key":"924_CR27","doi-asserted-by":"publisher","first-page":"116329","DOI":"10.1016\/j.neuroimage.2019.116329","volume":"206","author":"Y Chen","year":"2020","unstructured":"Chen Y, Fang Z, Hung SC, Chang WT, Shen D, Lin W (2020) High-resolution 3D MR Fingerprinting using parallel imaging and deep learning. Neuroimage 206:116329. https:\/\/doi.org\/10.1016\/j.neuroimage.2019.116329","journal-title":"Neuroimage"},{"issue":"11","key":"924_CR28","doi-asserted-by":"publisher","first-page":"e4389","DOI":"10.1002\/nbm.4389","volume":"33","author":"VC Keil","year":"2020","unstructured":"Keil VC, Bakoeva SP, Jurcoane A, Doneva M, Amthor T, Koken P, Madler B, Luchters G, Block W, Wullner U, Hattingen E (2020) A pilot study of magnetic resonance fingerprinting in Parkinson\u2019s disease. NMR Biomed 33(11):e4389. https:\/\/doi.org\/10.1002\/nbm.4389","journal-title":"NMR Biomed"},{"issue":"4","key":"924_CR29","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1093\/jnen\/63.4.275","volume":"63","author":"K Lamszus","year":"2004","unstructured":"Lamszus K (2004) Meningioma pathology, genetics, and biology. J Neuropathol Exp Neurol 63(4):275\u2013286. https:\/\/doi.org\/10.1093\/jnen\/63.4.275","journal-title":"J Neuropathol Exp Neurol"},{"issue":"2","key":"924_CR30","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.critrevonc.2008.01.010","volume":"67","author":"C Marosi","year":"2008","unstructured":"Marosi C, Hassler M, Roessler K, Reni M, Sant M, Mazza E, Vecht C (2008) Meningioma. Crit Rev Oncol Hematol 67(2):153\u2013171. https:\/\/doi.org\/10.1016\/j.critrevonc.2008.01.010","journal-title":"Crit Rev Oncol Hematol"},{"issue":"1","key":"924_CR31","first-page":"65","volume":"22","author":"CG Filippi","year":"2001","unstructured":"Filippi CG, Edgar MA, Ulug AM, Prowda JC, Heier LA, Zimmerman RD (2001) Appearance of meningiomas on diffusion-weighted images: correlating diffusion constants with histopathologic findings. AJNR Am J Neuroradiol 22(1):65\u201372","journal-title":"AJNR Am J Neuroradiol"},{"issue":"9","key":"924_CR32","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.3174\/ajnr.A1170","volume":"29","author":"CH Toh","year":"2008","unstructured":"Toh CH, Castillo M, Wong AM, Wei KC, Wong HF, Ng SH, Wan YL (2008) Differentiation between classic and atypical meningiomas with use of diffusion tensor imaging. AJNR Am J Neuroradiol 29(9):1630\u20131635. https:\/\/doi.org\/10.3174\/ajnr.A1170","journal-title":"AJNR Am J Neuroradiol"},{"issue":"4","key":"924_CR33","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.mri.2015.12.006","volume":"34","author":"RJ Piper","year":"2016","unstructured":"Piper RJ, Mikhael S, Wardlaw JM, Laidlaw DH, Whittle IR, Bastin ME (2016) Imaging signatures of meningioma and low-grade glioma: a diffusion tensor, magnetization transfer and quantitative longitudinal relaxation time MRI study. Magn Reson Imaging 34(4):596\u2013602. https:\/\/doi.org\/10.1016\/j.mri.2015.12.006","journal-title":"Magn Reson Imaging"},{"issue":"3","key":"924_CR34","doi-asserted-by":"publisher","first-page":"643","DOI":"10.3171\/2012.9.Jns12519","volume":"118","author":"MC Murphy","year":"2013","unstructured":"Murphy MC, Huston J 3rd, Glaser KJ, Manduca A, Meyer FB, Lanzino G, Morris JM, Felmlee JP, Ehman RL (2013) Preoperative assessment of meningioma stiffness using magnetic resonance elastography. J Neurosurg 118(3):643\u2013648. https:\/\/doi.org\/10.3171\/2012.9.Jns12519","journal-title":"J Neurosurg"},{"issue":"1","key":"924_CR35","doi-asserted-by":"publisher","first-page":"13769","DOI":"10.1038\/s41598-020-70789-2","volume":"10","author":"PA Gomez","year":"2020","unstructured":"Gomez PA, Cencini M, Golbabaee M, Schulte RF, Pirkl C, Horvath I, Fallo G, Peretti L, Tosetti M, Menze BH, Buonincontri G (2020) Rapid three-dimensional multiparametric MRI with quantitative transient-state imaging. Sci Rep 10(1):13769. https:\/\/doi.org\/10.1038\/s41598-020-70789-2","journal-title":"Sci Rep"},{"issue":"4","key":"924_CR36","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1002\/mrm.26009","volume":"76","author":"G Buonincontri","year":"2016","unstructured":"Buonincontri G, Sawiak SJ (2016) MR fingerprinting with simultaneous B1 estimation. Magn Reson Med 76(4):1127\u20131135. https:\/\/doi.org\/10.1002\/mrm.26009","journal-title":"Magn Reson Med"},{"issue":"8","key":"924_CR37","doi-asserted-by":"publisher","first-page":"e0201808","DOI":"10.1371\/journal.pone.0201808","volume":"13","author":"G Cruz","year":"2018","unstructured":"Cruz G, Schneider T, Bruijnen T, Gaspar AS, Botnar RM, Prieto C (2018) Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO). PLoS ONE 13(8):e0201808. https:\/\/doi.org\/10.1371\/journal.pone.0201808","journal-title":"PLoS ONE"},{"key":"924_CR38","unstructured":"Russek SE, Boss M, Jackson EF, Jennings DL, Evelhoch JL, Gunter Jl, Sorensen AG (2012) Characterization of NIST\/ISMRM MRRI system phantom. In: Paper presented at the ISMRM 20th Annual Meeting and Exhibition, Melbourne, Australia, May 5\u201311th"},{"issue":"3","key":"924_CR39","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116\u20131128. https:\/\/doi.org\/10.1016\/j.neuroimage.2006.01.015","journal-title":"Neuroimage"},{"issue":"6","key":"924_CR40","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1007\/s00259-019-04602-2","volume":"47","author":"J Haubold","year":"2020","unstructured":"Haubold J, Demircioglu A, Gratz M, Glas M, Wrede K, Sure U, Antoch G, Keyvani K, Nittka M, Kannengiesser S, Gulani V, Griswold M, Herrmann K, Forsting M, Nensa F, Umutlu L (2020) Non-invasive tumor decoding and phenotyping of cerebral gliomas utilizing multiparametric (18)F-FET PET-MRI and MR fingerprinting. Eur J Nucl Med Mol Imaging 47(6):1435\u20131445. https:\/\/doi.org\/10.1007\/s00259-019-04602-2","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"3","key":"924_CR41","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1148\/radiol.2018172131","volume":"288","author":"C Liao","year":"2018","unstructured":"Liao C, Wang K, Cao X, Li Y, Wu D, Ye H, Ding Q, He H, Zhong J (2018) Detection of lesions in mesial temporal lobe epilepsy by using mr fingerprinting. Radiology 288(3):804\u2013812. https:\/\/doi.org\/10.1148\/radiol.2018172131","journal-title":"Radiology"},{"issue":"2","key":"924_CR42","doi-asserted-by":"publisher","first-page":"136","DOI":"10.18383\/j.tom.2015.00166","volume":"1","author":"C Badve","year":"2015","unstructured":"Badve C, Yu A, Rogers M, Ma D, Liu Y, Schluchter M, Sunshine J, Griswold M, Gulani V (2015) Simultaneous T(1) and T(2) brain relaxometry in asymptomatic volunteers using magnetic resonance fingerprinting. Tomography 1(2):136\u2013144. https:\/\/doi.org\/10.18383\/j.tom.2015.00166","journal-title":"Tomography"},{"issue":"3","key":"924_CR43","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1007\/s10334-017-0659-3","volume":"31","author":"JM Spijkerman","year":"2018","unstructured":"Spijkerman JM, Petersen ET, Hendrikse J, Luijten P, Zwanenburg JJM (2018) T (2) mapping of cerebrospinal fluid: 3T versus 7 T. MAGMA 31(3):415\u2013424. https:\/\/doi.org\/10.1007\/s10334-017-0659-3","journal-title":"MAGMA"},{"issue":"1","key":"924_CR44","doi-asserted-by":"publisher","first-page":"96","DOI":"10.2463\/mrms.tn.2018-0027","volume":"18","author":"Y Kobayashi","year":"2019","unstructured":"Kobayashi Y, Terada Y (2019) Diffusion-weighting caused by spoiler gradients in the fast imaging with steady-state precession sequence may lead to inaccurate T(2) measurements in MR fingerprinting. Magn Reson Med Sci 18(1):96\u2013104. https:\/\/doi.org\/10.2463\/mrms.tn.2018-0027","journal-title":"Magn Reson Med Sci"},{"issue":"2","key":"924_CR45","doi-asserted-by":"publisher","first-page":"136","DOI":"10.18383\/j.tom.2015.00166","volume":"1","author":"C Badve","year":"2015","unstructured":"Badve C, Yu A, Rogers M, Ma D, Liu Y, Schluchter M, Sunshine J, Griswold M, Gulani V (2015) Simultaneous T1 and T2 brain relaxometry in asymptomatic volunteers using magnetic resonance fingerprinting. Tomography 1(2):136\u2013144. https:\/\/doi.org\/10.18383\/j.tom.2015.00166","journal-title":"Tomography"},{"issue":"1","key":"924_CR46","first-page":"65","volume":"8","author":"M Komiyama","year":"1987","unstructured":"Komiyama M, Yagura H, Baba M, Yasui T, Hakuba A, Nishimura S, Inoue Y (1987) MR imaging: possibility of tissue characterization of brain tumors using T1 and T2 values. AJNR Am J Neuroradiol 8(1):65\u201370","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"924_CR47","first-page":"463","volume":"10","author":"T Watabe","year":"1989","unstructured":"Watabe T, Azuma T (1989) T1 and T2 measurements of meningiomas and neuromas before and after Gd-DTPA. AJNR Am J Neuroradiol 10(3):463\u2013470","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"924_CR48","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1177\/0284185115578323","volume":"57","author":"K Watanabe","year":"2016","unstructured":"Watanabe K, Kakeda S, Yamamoto J, Ide S, Ohnari N, Nishizawa S, Korogi Y (2016) Prediction of hard meningiomas: quantitative evaluation based on the magnetic resonance signal intensity. Acta Radiol 57(3):333\u2013340. https:\/\/doi.org\/10.1177\/0284185115578323","journal-title":"Acta Radiol"},{"key":"924_CR49","unstructured":"Zhang R, Bai Y, Zhang X, Feng Q, Wang M, Zhang M, Nittka M, Koerzdoerfer G, Lin Y, Wang M (2020) Magnetic resonance fingerprinting for preoperative differentiation of soft and hard meningiomas. In: Paper presented at the ISMRM & SMRT Virtual Conference & Exhibition, Virtual Meeting, August 10th, 2020\u2013August 14th, 2020"},{"issue":"1","key":"924_CR50","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3340\/jkns.2011.49.1.26","volume":"49","author":"BW Kim","year":"2011","unstructured":"Kim BW, Kim MS, Kim SW, Chang CH, Kim OL (2011) Peritumoral brain edema in meningiomas: correlation of radiologic and pathologic features. J Korean Neurosurg Soc 49(1):26\u201330. https:\/\/doi.org\/10.3340\/jkns.2011.49.1.26","journal-title":"J Korean Neurosurg Soc"},{"issue":"2","key":"924_CR51","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.nec.2015.11.004","volume":"27","author":"B Tamrazi","year":"2016","unstructured":"Tamrazi B, Shiroishi MS, Liu CS (2016) Advanced imaging of intracranial meningiomas. Neurosurg Clin N Am 27(2):137\u2013143. https:\/\/doi.org\/10.1016\/j.nec.2015.11.004","journal-title":"Neurosurg Clin N Am"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-021-00924-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10334-021-00924-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-021-00924-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T15:09:07Z","timestamp":1630940947000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10334-021-00924-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,4]]},"references-count":51,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["924"],"URL":"https:\/\/doi.org\/10.1007\/s10334-021-00924-1","relation":{},"ISSN":["0968-5243","1352-8661"],"issn-type":[{"value":"0968-5243","type":"print"},{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,4]]},"assertion":[{"value":"18 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 March 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research was approved by the Mayo Clinic Institutional review board and all patients were consented.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors have no conflict of interest to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}