{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:08:41Z","timestamp":1790208521976,"version":"4.1.0"},"reference-count":55,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T00:00:00Z","timestamp":1684540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T00:00:00Z","timestamp":1684540800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Simon Stevin Meester prize"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>Low-cost low-field point-of-care MRI systems are used in many different applications. System design has correspondingly different requirements in terms of imaging field-of-view, spatial resolution and magnetic field strength. In this work an iterative framework has been created to design a cylindrical Halbach-based magnet along with integrated gradient and RF coils that most efficiently fulfil a set of user-specified imaging requirements.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>For efficient integration, target field methods are used for each of the main hardware components. These have not been used previously in magnet design, and a new mathematical model was derived accordingly. These methods result in a framework which can design an entire low-field MRI system within minutes using standard computing hardware.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Two distinct point-of-care systems are designed using the described framework, one for neuroimaging and the other for extremity imaging. Input parameters are taken from literature and the resulting systems are discussed in detail.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>The framework allows the designer to optimize the different hardware components with respect to the desired imaging parameters taking into account the interdependencies between these components and thus give insight into the influence of the design choices.<\/jats:p><\/jats:sec>","DOI":"10.1007\/s10334-023-01093-z","type":"journal-article","created":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T02:01:38Z","timestamp":1684548098000},"page":"395-408","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["An integrated target field framework for point-of-care halbach array low-field MRI system design"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2697-5597","authenticated-orcid":false,"given":"Bart","family":"de Vos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rob F.","family":"Remis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew G.","family":"Webb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,5,20]]},"reference":[{"key":"1093_CR1","first-page":"4846","volume":"11","author":"UC Anazodo","year":"2022","unstructured":"Anazodo UC et al (2022) A framework for advancing Sustainable Magnetic Resonance Imaging Access in Africa. NMR Biomed 11:4846","journal-title":"NMR Biomed"},{"key":"1093_CR2","doi-asserted-by":"publisher","first-page":"240","DOI":"10.11604\/pamj.2018.30.240.14000","volume":"30","author":"GI Ogbole","year":"2018","unstructured":"Ogbole GI, Adeyomoye AO, Badu-Peprah A, Mensah Y, Nzeh DA (2018) Survey of magnetic resonance imaging availability in West Africa. Pan Afr Med J 30:240","journal-title":"Pan Afr Med J"},{"key":"1093_CR3","unstructured":"International atomic Energy Agency, MRI units per million inhabitants. [Online]. Available: https:\/\/humanhealth.iaea.org\/HHW\/DBStatistics\/IMAGINEMaps3.html"},{"issue":"11","key":"1093_CR4","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1097\/RLI.0000000000000810","volume":"56","author":"M Hori","year":"2021","unstructured":"Hori M, Hagiwara A, Goto M, Wada A, Aoki S (2021) Low-field magnetic resonance imaging: Its History and Renaissance. Investig Radiol 56(11):669\u2013679","journal-title":"Investig Radiol"},{"key":"1093_CR5","doi-asserted-by":"publisher","first-page":"1528","DOI":"10.1002\/jmri.26637","volume":"49","author":"JP Marques","year":"2019","unstructured":"Marques JP, Simonis FFJ, Webb AG (2019) Low-field MRI: An MR Physics Perspective. J Magn Reson Imaging 49:1528\u20131542. https:\/\/doi.org\/10.1002\/jmri.26637","journal-title":"J Magn Reson Imaging"},{"key":"1093_CR6","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2020.00172","author":"M Sarracanie","year":"2020","unstructured":"Sarracanie M, Salameh N (2020) Low-field MRI How low can we go? A fresh view on an old debate. Front Phys. https:\/\/doi.org\/10.3389\/fphy.2020.00172","journal-title":"Front Phys"},{"key":"1093_CR7","doi-asserted-by":"publisher","first-page":"179","DOI":"10.13104\/imri.2019.23.3.179","volume":"23","author":"S Huang","year":"2019","unstructured":"Huang S, Ren ZH, Obruchkov S, Gong JI, Dykstra R, Yu W (2019) Portable low-cost MRI system based on permanent magnets\/magnet arrays. Investig Magn Reson Imaging 23:179","journal-title":"Investig Magn Reson Imaging"},{"key":"1093_CR8","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1002\/jmri.26942","volume":"52","author":"LL Wald","year":"2019","unstructured":"Wald LL, McDaniel PC, Witzel T, Stockmann JP, Cooley CZ (2019) Low-cost and portable MRI. J Magn Reson Imaging 52:686\u2013696","journal-title":"J Magn Reson Imaging"},{"key":"1093_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jmr.2019.04.017","volume":"304","author":"M Nakagomi","year":"2019","unstructured":"Nakagomi M, Kajiwara M, Matsuzaki J, Tanabe K, Hoshiai S, Okamoto Y, Terada Y (2019) Development of a small car-mounted magnetic resonance imaging system for human elbows using a 0.2 T permanent magnet. J Magn Reson 304:1\u20136","journal-title":"J Magn Reson"},{"key":"1093_CR10","doi-asserted-by":"publisher","first-page":"106829","DOI":"10.1016\/j.jmr.2020.106829","volume":"319","author":"Y He","year":"2020","unstructured":"He Y, He W, Tan L, Chen F, Meng F, Feng H, Xu Z (2020) Use of 2.1 MHz MRI scanner for brain imaging and its preliminary results in stroke. J Magn Reson 319:106829","journal-title":"J Magn Reson"},{"key":"1093_CR11","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1001\/jamaneurol.2020.3263","volume":"78","author":"KN Sheth","year":"2021","unstructured":"Sheth KN, Mazurek MH, Yuen MM et al (2021) Assessment of brain injury using portable, low-field magnetic resonance imaging at the bedside of critically ill patients. JAMA Neurol 78:41","journal-title":"JAMA Neurol"},{"key":"1093_CR12","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-25441","author":"MH Mazurek","year":"2021","unstructured":"Mazurek MH et al (2021) Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage. Nat Commun. https:\/\/doi.org\/10.1038\/s41467-021-25441","journal-title":"Nat Commun"},{"issue":"15","key":"1093_CR13","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1212\/WNL.94.15_supplement.272","volume":"94","author":"B Cahn","year":"2020","unstructured":"Cahn B et al (2020) Deployment of Portable, Bedside, Low-field Magnetic Resonance Imaging for Evaluation of Stroke Patients. Neurology 94(15):272","journal-title":"Neurology"},{"key":"1093_CR14","doi-asserted-by":"publisher","first-page":"118273","DOI":"10.1016\/j.neuroimage.2021.118273","volume":"238","author":"SCL Deoni","year":"2021","unstructured":"Deoni SCL et al (2021) Accessible pediatric neuroimaging using a low field strength MRI scanner. Neuroimage 238:118273","journal-title":"Neuroimage"},{"key":"1093_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-09760-2","author":"SC Deoni","year":"2022","unstructured":"Deoni SC et al (2022) Development of a mobile low-field MRI scanner. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-022-09760-2","journal-title":"Sci Rep"},{"key":"1093_CR16","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.a7494","author":"K Chetcuti","year":"2022","unstructured":"Chetcuti K et al (2022) Implementation of a low-field portable MRI scanner in a resource-constrained environment: Our experience in Malawi. AJNR Am J Neuroradiol. https:\/\/doi.org\/10.3174\/ajnr.a7494","journal-title":"AJNR Am J Neuroradiol"},{"key":"1093_CR17","doi-asserted-by":"publisher","DOI":"10.1101\/2021.07.02.21259789","author":"TC Arnold","year":"2021","unstructured":"Arnold TC, Baldassano SN, Litt B, Stein JM (2021) Simulated diagnostic performance of ultra-low-field MRI: Harnessing open-access datasets to evaluate novel devices. Magn Reson Imaging. https:\/\/doi.org\/10.1101\/2021.07.02.21259789","journal-title":"Magn Reson Imaging"},{"key":"1093_CR18","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-27317-1","author":"Y Liu","year":"2021","unstructured":"Liu Y et al (2021) A low-cost and shielding-free ultra-low-field brain MRI scanner. Nat Commun. https:\/\/doi.org\/10.1038\/s41467-021-27317-1","journal-title":"Nat Commun"},{"key":"1093_CR19","doi-asserted-by":"publisher","first-page":"106625","DOI":"10.1016\/j.jmr.2019.106625","volume":"310","author":"CZ Cooley","year":"2020","unstructured":"Cooley CZ et al (2020) Design and implementation of a low-cost, tabletop MRI scanner for education and Research Prototyping. J Magn Reson 310:106625","journal-title":"J Magn Reson"},{"key":"1093_CR20","doi-asserted-by":"publisher","first-page":"3882","DOI":"10.1109\/TNS.1979.4330638","volume":"26","author":"K Halbach","year":"1979","unstructured":"Halbach K (1979) Strong rare earth cobalt quadrupoles. IEEE Trans Nucl Sci 26:3882\u20132884","journal-title":"IEEE Trans Nucl Sci"},{"key":"1093_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0029-554X(80)90094-4","volume":"169","author":"K Halbach","year":"1980","unstructured":"Halbach K (1980) Design of permanent multipole magnets with oriented rare earth cobalt material. Nucl Instrum Methods 169:1\u201310","journal-title":"Nucl Instrum Methods"},{"key":"1093_CR22","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/0167-5087(82)90258-7","volume":"198","author":"K Halbach","year":"1982","unstructured":"Halbach K (1982) Perturbation effects in segmented rare earth cobalt multipole magnets. Nucl Instrum Methods 198:213\u2013215","journal-title":"Nucl Instrum Methods"},{"key":"1093_CR23","first-page":"16","volume":"23B","author":"H Raich","year":"2004","unstructured":"Raich H, Bl\u00fcmler P (2004) Design and construction of a dipolar halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas Concepts Magn. Reson, Part B 23B:16\u201325","journal-title":"Reson, Part B"},{"key":"1093_CR24","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jmr.2010.09.020","volume":"208","author":"CW Windt","year":"2011","unstructured":"Windt CW, Soltner H, Dvan D, Bl\u00fcmler P (2011) A portable halbach magnet that can be opened and closed without force: The NMR-cuff. J Magn Reson 208:27\u201333","journal-title":"J Magn Reson"},{"key":"1093_CR25","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1002\/cmr.a.20165","volume":"36A","author":"H Soltner","year":"2010","unstructured":"Soltner H, Bl\u00fcmler P (2010) Dipolar Halbach magnet stacks made from identically shaped permanent magnets for Magnetic Resonance. Concepts Magn Reason Part A 36A:211\u2013222","journal-title":"Concepts Magn Reason Part A"},{"key":"1093_CR26","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1002\/cmr.b.21320","volume":"46","author":"P Bl\u00fcmler","year":"2016","unstructured":"Bl\u00fcmler P (2016) Proposal for a permanent magnet system with a constant gradient mechanically adjustable in direction and strength. Concepts Magn Reason Part B 46:41\u201348","journal-title":"Concepts Magn Reason Part B"},{"key":"1093_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2017.2751001","volume":"54","author":"CZ Cooley","year":"2018","unstructured":"Cooley CZ, Haskell MW, Cauley SF, Sappo C, Lapierre CD, Ha CG, Stockmann JP, Wald LL (2018) Design of sparse halbach magnet arrays for portable MRI using a genetic algorithm. IEEE Trans Magn 54:1\u201312","journal-title":"IEEE Trans Magn"},{"key":"1093_CR28","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1038\/s41551-020-00641-5","volume":"5","author":"CZ Cooley","year":"2020","unstructured":"Cooley CZ et al (2020) A portable scanner for Magnetic Resonance Imaging of the brain. Nat Biomed Eng 5:229\u2013239","journal-title":"Nat Biomed Eng"},{"key":"1093_CR29","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1002\/mrm.28992","volume":"87","author":"SA Srinivas","year":"2021","unstructured":"Srinivas SA et al (2021) External dynamic interference estimation and removal (EDITER) for low Field MRI. Magn Reson Med 87:614\u2013628","journal-title":"Magn Reson Med"},{"key":"1093_CR30","doi-asserted-by":"publisher","first-page":"102903","DOI":"10.1016\/j.msard.2021.102903","volume":"51","author":"FJ Mateen","year":"2021","unstructured":"Mateen FJ, Cooley CZ, Stockmann JP, Rice DR, Vogel AC, Wald LL (2021) Low-field portable brain MRI in CNS demyelinating disease. Mult Scler Relat Disord 51:102903","journal-title":"Mult Scler Relat Disord"},{"key":"1093_CR31","doi-asserted-by":"publisher","first-page":"106578","DOI":"10.1016\/j.jmr.2019.106578","volume":"307","author":"T O'Reilly","year":"2019","unstructured":"O\u2019Reilly T, Teeuwisse WM, Webb AG (2019) Three-dimensional MRI in a homogenous 27 cm diameter bore Halbach Array Magnet. J Magn Reson 307:106578","journal-title":"J Magn Reson"},{"key":"1093_CR32","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1002\/mrm.28396","volume":"85","author":"T O\u2019Reilly","year":"2020","unstructured":"O\u2019Reilly T, Teeuwisse WM, Gans D, Koolstra K, Webb AG (2020) In vivo 3D brain and extremity MRI at 50 MT using a permanent magnet halbach array. Magn Reason Med 85:495\u2013505","journal-title":"Magn Reason Med"},{"key":"1093_CR33","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4825","author":"T Guallart-Naval","year":"2022","unstructured":"Guallart-Naval T et al (2022) Benchmarking the performance of a low-cost magnetic resonance control system at multiple sites in the open marcos community. NMR Biomed. https:\/\/doi.org\/10.1002\/nbm.4825","journal-title":"NMR Biomed"},{"key":"1093_CR34","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1002\/cmr.a.20163","volume":"36A","author":"SS Hidalgo-Tobon","year":"2010","unstructured":"Hidalgo-Tobon SS (2010) Theory of gradient coil design methods for magnetic resonance imaging. concepts magn. Reson A: Bridg Educ Res 36A:223\u2013242. https:\/\/doi.org\/10.1002\/cmr.a.20163","journal-title":"Reson A: Bridg Educ Res"},{"issue":"1","key":"1093_CR35","first-page":"71","volume":"24","author":"DI Hoult","year":"1976","unstructured":"Hoult DI, Richards RE (1976) The signal-to-noise ratio of Nuclear Magnetic resonance experiment. J Magn Reson 24(1):71\u201385","journal-title":"J Magn Reson"},{"key":"1093_CR36","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1088\/0022-3735\/21\/10\/008","volume":"21","author":"R Turner","year":"1988","unstructured":"Turner R (1988) Minimum inductance coils. J Phys E Sci Instrum 21:948\u2013952","journal-title":"J Phys E Sci Instrum"},{"key":"1093_CR37","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/19\/8\/001","author":"R Turner","year":"1986","unstructured":"Turner R (1986) A target field approach to optimal coil design. J Phys D: Appl Phys. https:\/\/doi.org\/10.1088\/0022-3727\/19\/8\/001","journal-title":"J Phys D: Appl Phys"},{"key":"1093_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2019.2958561","volume":"56","author":"B de Vos","year":"2020","unstructured":"de Vos B, Fuchs P, O\u2019Reilly T, Webb A, Remis R (2020) Gradient coil design and realization for a Halbach-based MRI system. IEEE Trans Magn 56:1\u20138","journal-title":"IEEE Trans Magn"},{"key":"1093_CR39","doi-asserted-by":"publisher","first-page":"3447","DOI":"10.1088\/0022-3727\/34\/24\/305","volume":"34","author":"LK Forbes","year":"2001","unstructured":"Forbes LK, Crozier S (2001) A novel target-field method for finite-length magnetic resonance Shim Coils: I. Zonal Shims. J Phys D: Appl Phys 34:3447\u20133455","journal-title":"J Phys D: Appl Phys"},{"key":"1093_CR40","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1088\/0022-3727\/35\/9\/303","volume":"35","author":"LK Forbes","year":"2002","unstructured":"Forbes LK, Crozier S (2002) A novel target-field method for finite-length magnetic resonance Shim Coils: II. Tesseral Shims. J Phys D: Appl Phys 35:839\u2013849","journal-title":"J Phys D: Appl Phys"},{"key":"1093_CR41","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2021.701157","author":"B de Vos","year":"2021","unstructured":"de Vos B et al (2021) Design, characterisation and performance of an improved portable and sustainable low-field MRI system. Front Phys. https:\/\/doi.org\/10.3389\/fphy.2021.701157","journal-title":"Front Phys"},{"key":"1093_CR42","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1109\/TMAG.2012.2205014","volume":"49","author":"AJ Petruska","year":"2013","unstructured":"Petruska AJ, Abbott JJ (2013) Optimal Permanent-magnet geometries for dipole field approximation. IEEE Trans Magn 49:811\u2013819","journal-title":"IEEE Trans Magn"},{"key":"1093_CR43","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1007\/978-0-387-40065-5_3","volume-title":"numerical optimisation","author":"J Nocedal","year":"2006","unstructured":"Nocedal J, Wright SJ (2006) Line search methods. In: Priya D (ed) numerical optimisation, 2nd edn. Springer, New York, pp 30\u201363","edition":"2"},{"key":"1093_CR44","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1002\/cmr.10000","volume":"14","author":"MA Brideson","year":"2001","unstructured":"Brideson MA, Forbes LK, Crozier S (2001) Determining complicated winding patterns for shim coils using stream functions and the target-field method. Concepts Magn Reson 14:9\u201318","journal-title":"Concepts Magn Reson"},{"key":"1093_CR45","volume-title":"Computational design and fabrication of portable mri systems dissertation","author":"PC McDaniel","year":"2020","unstructured":"McDaniel PC (2020) Computational design and fabrication of portable mri systems dissertation. department of electrical engineering and computer science massachusetts institute of technology, Cambridge Massachusetts"},{"key":"1093_CR46","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1109\/9780470545652","volume-title":"Principles magnetic resonance imaging: a signal processing perspective","author":"Z Liang","year":"1999","unstructured":"Liang Z, Signal LPC (1999) Characteristics. In: Priya D (ed) Principles magnetic resonance imaging: a signal processing perspective. John Wiley & sons, pp 111\u2013114"},{"key":"1093_CR47","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1002\/mrm.29009","volume":"87","author":"T O\u2019Reilly","year":"2021","unstructured":"O\u2019Reilly T, Webb AG (2021) In vivo T1 and T2 relaxation time maps of brain tissue, skeletal muscle, and lipid measured in healthy volunteers at 50 mT. Magn Reason 87:884\u2013895","journal-title":"Magn Reason"},{"key":"1093_CR48","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1002\/9781118633953","volume-title":"Magnetic Resoanance Imaging, physical principles and sequence design","author":"RW Brown","year":"2014","unstructured":"Brown RW, Cheng YN, Haacke EM, Thompson MR, Venkatesan R (2014) Filtering and Resolution in Fourier Transform Image Reconstruction. In: Priya D (ed) Magnetic Resoanance Imaging, physical principles and sequence design, 2nd edn. Wiley Blackwell, New Jersey, p 281","edition":"2"},{"key":"1093_CR49","doi-asserted-by":"publisher","first-page":"95294","DOI":"10.1109\/ACCESS.2021.3093530","volume":"9","author":"AR Purchase","year":"2021","unstructured":"Purchase AR et al (2021) A short and light, sparse dipolar halbach magnet for MRI. IEEE Access. 9:95294","journal-title":"IEEE Access."},{"key":"1093_CR50","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.jmr.2016.01.014","volume":"265","author":"AJ Parker","year":"2016","unstructured":"Parker AJ, Zia W, Rehorn CWG, Bl\u00fcmich B (2016) Shimming halbach magnets utilizing genetic algorithms to profit from material imperfections. J of Magn Reason 265:83\u201389","journal-title":"J of Magn Reason"},{"key":"1093_CR51","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2021.704566","author":"K Wenzel","year":"2021","unstructured":"Wenzel K, Alhamwey H, O\u2019Reilly T, Riemann LT, Silemek B, Winter L (2021) B0-shimming methodology for affordable and compact low-field magnetic resonance imaging magnets. Front Phys. https:\/\/doi.org\/10.3389\/fphy.2021.704566","journal-title":"Front Phys"},{"issue":"1","key":"1093_CR52","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.jmr.2005.03.015","volume":"175","author":"PL Volegov","year":"2005","unstructured":"Volegov PL, Mosher JC, Espy MA, Kraus RH Jr (2005) On concomitant gradients in low-field MRI. J Magn Reson 175(1):103\u201313","journal-title":"J Magn Reson"},{"issue":"4","key":"1093_CR53","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1002\/mrm.1910400411","volume":"40","author":"XJ Zhou","year":"1998","unstructured":"Zhou XJ, Tan SG, Bernstein MA (1998) Artifacts induced by concomitant magnetic field in fast spin-echo imaging. Magn Reson Med 40(4):582\u2013591","journal-title":"Magn Reson Med"},{"issue":"2","key":"1093_CR54","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1002\/mrm.1910390218","volume":"39","author":"MA Bernstein","year":"1998","unstructured":"Bernstein MA, Zhou XJ, Polzin JA, King KF, Ganin A, Pelc NJ, Glover GH (1998) Concomitant gradient terms in phase contrast MR: analysis and correction. Magn Reson Med 39(2):300\u2013308","journal-title":"Magn Reson Med"},{"issue":"1","key":"1093_CR55","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1002\/(SICI)1522-2594(199901)41:1<103::AID-MRM15>3.0.CO;2-M","volume":"41","author":"KF King","year":"1999","unstructured":"King KF, Ganin A, Zhou XJ, Bernstein MA (1999) Concomitant gradient field effects in spiral scans. Magn Reson Med 41(1):103\u201312","journal-title":"Magn Reson Med"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-023-01093-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10334-023-01093-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-023-01093-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T12:56:24Z","timestamp":1702472184000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10334-023-01093-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,20]]},"references-count":55,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,7]]}},"alternative-id":["1093"],"URL":"https:\/\/doi.org\/10.1007\/s10334-023-01093-z","relation":{},"ISSN":["1352-8661"],"issn-type":[{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,20]]},"assertion":[{"value":"14 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by an of the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical standard"}}]}}