{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T02:15:44Z","timestamp":1785723344273,"version":"3.56.0"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,8,12]],"date-time":"2024-08-12T00:00:00Z","timestamp":1723420800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,12]],"date-time":"2024-08-12T00:00:00Z","timestamp":1723420800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Physikalisch-Technische Bundesanstalt (PTB)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>The purpose of this study was to investigate an approach for motion-corrected T1 mapping of the abdomen that allows for free breathing data acquisition with 100% scan efficiency.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>Data were acquired using a continuous golden radial trajectory and multiple inversion pulses. For the correction of respiratory motion, motion estimation based on a surrogate was performed from the same data used for T1 mapping. Image-based self-navigation allowed for binning and reconstruction of respiratory-resolved images, which were used for the estimation of respiratory motion fields. Finally, motion-corrected T1 maps were calculated from the data applying the estimated motion fields. The method was evaluated in five healthy volunteers. For the assessment of the image-based navigator, we compared it to a simultaneously acquired ultrawide band radar signal. Motion-corrected T1 maps were evaluated qualitatively and quantitatively for different scan times.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>For all volunteers, the motion-corrected T1 maps showed fewer motion artifacts in the liver as well as sharper kidney structures and blood vessels compared to uncorrected T1 maps. Moreover, the relative error to the reference breathhold T1 maps could be reduced from up to 25% for the uncorrected T1 maps to below 10% for the motion-corrected maps for the average value of a region of interest, while the scan time could be reduced to 6-8\u00a0s.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Discussion<\/jats:title>\n                <jats:p>The proposed approach allows for respiratory motion-corrected T1 mapping in the abdomen and ensures accurate T1 maps without the need for any breathholds.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10334-024-01196-1","type":"journal-article","created":{"date-parts":[[2024,8,12]],"date-time":"2024-08-12T12:02:32Z","timestamp":1723464152000},"page":"637-649","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Respiratory motion-corrected T1 mapping of the abdomen"],"prefix":"10.1007","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8856-2670","authenticated-orcid":false,"given":"Jana Huiyue","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Neumann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Schaeffter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Kolbitsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirsten Miriam","family":"Kerkering","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,12]]},"reference":[{"issue":"1","key":"1196_CR1","doi-asserted-by":"publisher","first-page":"7","DOI":"10.5152\/dir.2020.19654","volume":"27","author":"A Erden","year":"2021","unstructured":"Erden A et al (2021) Mri quantification techniques in fatty liver: the diagnostic performance of hepatic T1, T2, and stiffness measurements in relation to the proton density fat fraction. Diagn Interv Radiol 27(1):7\u201314. https:\/\/doi.org\/10.5152\/dir.2020.19654","journal-title":"Diagn Interv Radiol"},{"issue":"3","key":"1196_CR2","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1002\/jmri.25030","volume":"43","author":"Z Li","year":"2016","unstructured":"Li Z et al (2016) Assessment of liver fibrosis by variable flip angle T1 mapping at 3.0T. J Magn Reson Imaging 43(3):698\u2013703. https:\/\/doi.org\/10.1002\/jmri.25030","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"1196_CR3","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1007\/s00330-012-2378-5","volume":"22","author":"T Heye","year":"2012","unstructured":"Heye T et al (2012) MR relaxometry of the liver: significant elevation of T1 relaxation time in patients with liver cirrhosis. Eur Radiol 22(6):1224\u20131232. https:\/\/doi.org\/10.1007\/s00330-012-2378-5","journal-title":"Eur Radiol"},{"issue":"5","key":"1196_CR4","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1002\/jmri.22543","volume":"33","author":"Y Huang","year":"2011","unstructured":"Huang Y et al (2011) Measurement and comparison of T1 relaxation times in native and transplanted kidney cortex and medulla. J Magn Reson Imaging 33(5):1241\u20131247. https:\/\/doi.org\/10.1002\/jmri.22543","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"1196_CR5","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/s00330-017-4943-4","volume":"28","author":"M Peperhove","year":"2018","unstructured":"Peperhove M et al (2018) Assessment of acute kidney injury with T1 mapping MRI following solid organ transplantation. Eur Radiol 28(1):44\u201350. https:\/\/doi.org\/10.1007\/s00330-017-4943-4","journal-title":"Eur Radiol"},{"issue":"4","key":"1196_CR6","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1002\/jmri.25428","volume":"45","author":"T Tirkes","year":"2017","unstructured":"Tirkes T, Lin C, Fogel EL, Sherman SS, Wang Q, Sandrasegaran K (2017) T1 mapping for diagnosis of mild chronic pancreatitis. J Magn Reson Imaging 45(4):1171\u20131176. https:\/\/doi.org\/10.1002\/jmri.25428","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"1196_CR7","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jcmg.2015.11.005","volume":"9","author":"AJ Taylor","year":"2016","unstructured":"Taylor AJ, Salerno M, Dharmakumar R, Jerosch-Herold M (2016) T1 Mapping: Basic Techniques and Clinical Applications. JACC Cardiovasc Imaging 9(1):67\u201381","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"1196_CR8","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1063\/1.1684482","volume":"41","author":"DC Look","year":"1970","unstructured":"Look DC, Locker DR (1970) Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 41(2):250\u2013251","journal-title":"Rev Sci Instrum"},{"key":"1196_CR9","first-page":"608","volume":"96","author":"R Deichmann","year":"1992","unstructured":"Deichmann R, Haase A (1992) Quantification of T1 values by SNAPSHOT-FLASH NMR imaging. J Magn Reson 96:608\u2013612","journal-title":"J Magn Reson"},{"issue":"3","key":"1196_CR10","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1002\/mrm.22162","volume":"63","author":"M Honal","year":"2010","unstructured":"Honal M, Leupold J, Huff S, Baumann T, Ludwig U (2010) Compensation of breathing motion artifacts for MRI with continuously moving table. Magn Reson Med 63(3):701\u2013712. https:\/\/doi.org\/10.1002\/mrm.22162","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR11","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1148\/radiol.2502071998","volume":"250","author":"AD Scott","year":"2009","unstructured":"Scott AD, Keegan J, Firmin DN (2009) Motion in cardiovascular MR imaging. Radiology 250(2):331\u2013351","journal-title":"Radiology"},{"issue":"5","key":"1196_CR12","doi-asserted-by":"publisher","first-page":"2403","DOI":"10.1002\/mrm.28580","volume":"85","author":"J Ludwig","year":"2021","unstructured":"Ludwig J, Speier P, Seifert F, Schaeffter T, Kolbitsch C (2021) Pilot tone\u2013based motion correction for prospective respiratory compensated cardiac cine MRI. Magn Reson Med 85(5):2403\u20132416. https:\/\/doi.org\/10.1002\/mrm.28580","journal-title":"Magn Reson Med"},{"key":"1196_CR13","doi-asserted-by":"publisher","first-page":"100312","DOI":"10.1016\/j.ejro.2020.100312","volume":"8","author":"M Mio","year":"2021","unstructured":"Mio M, Fujiwara Y, Tani K, Toyofuku T, Maeda T, Inoue T (2021) Quantitative evaluation of focal liver lesions with T1 mapping using a phase-sensitive inversion recovery sequence on gadoxetic acid-enhanced MRI. Eur J Radiol Open 8:100312. https:\/\/doi.org\/10.1016\/j.ejro.2020.100312","journal-title":"Eur J Radiol Open"},{"issue":"1","key":"1196_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12880-022-00873-8","volume":"22","author":"F Wang","year":"2022","unstructured":"Wang F, Yang Q, Zhang Y, Liu J, Liu M, Zhu J (2022) 3D variable flip angle T1 mapping for differentiating benign and malignant liver lesions at 3T: comparison with diffusion weighted imaging. BMC Med Imaging 22(1):1\u20139. https:\/\/doi.org\/10.1186\/s12880-022-00873-8","journal-title":"BMC Med Imaging"},{"issue":"4","key":"1196_CR15","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1002\/mrm.22687","volume":"65","author":"C Santelli","year":"2011","unstructured":"Santelli C et al (2011) Respiratory bellows revisited for motion compensation: preliminary experience for cardiovascular MR. Magn Reson Med 65(4):1097\u20131102. https:\/\/doi.org\/10.1002\/mrm.22687","journal-title":"Magn Reson Med"},{"issue":"4","key":"1196_CR16","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1097\/00004728-198507010-00039","volume":"9","author":"DR Bailes","year":"1985","unstructured":"Bailes DR, Gilderdale DJ, Bydder GM, Collins AG, Firmin DN (1985) Respiratory ordered phase encoding (Rope): a method for reducing respiratory motion artefacts in mr imaging. J Comput Assist Tomogr 9(4):835\u2013838. https:\/\/doi.org\/10.1097\/00004728-198507010-00039","journal-title":"J Comput Assist Tomogr"},{"issue":"3","key":"1196_CR17","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/RLI.0000000000000619","volume":"55","author":"T Vahle","year":"2020","unstructured":"Vahle T et al (2020) Respiratory motion detection and correction for MR using the pilot tone: applications for MR and simultaneous PET\/MR examinations. Invest Radiol 55(3):153\u2013159. https:\/\/doi.org\/10.1097\/RLI.0000000000000619","journal-title":"Invest Radiol"},{"key":"1196_CR18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acbb51","author":"T Neumann","year":"2023","unstructured":"Neumann T et al (2023) Ultra-wide band radar for prospective respiratory motion correction in the liver. Phys Med Biol. https:\/\/doi.org\/10.1088\/1361-6560\/acbb51","journal-title":"Phys Med Biol"},{"issue":"1","key":"1196_CR19","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1148\/radiology.173.1.2781017","volume":"173","author":"RL Ehman","year":"1989","unstructured":"Ehman RL, Felmlee JP (1989) Adaptive technique for high-definition MR imaging of moving structures. Radiology 173(1):255\u2013263. https:\/\/doi.org\/10.1148\/radiology.173.1.2781017","journal-title":"Radiology"},{"issue":"2","key":"1196_CR20","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1002\/mrm.20557","volume":"54","author":"C Stehning","year":"2005","unstructured":"Stehning C, B\u00f6rnert P, Nehrke K, Eggers H, Stuber M (2005) Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 54(2):476\u2013480. https:\/\/doi.org\/10.1002\/mrm.20557","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR21","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1002\/mrm.23247","volume":"68","author":"D Piccini","year":"2012","unstructured":"Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO (2012) Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med 68(2):571\u2013579. https:\/\/doi.org\/10.1002\/mrm.23247","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR22","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1002\/mrm.24280","volume":"69","author":"M Henningsson","year":"2013","unstructured":"Henningsson M, Smink J, Razavi R, Botnar RM (2013) Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator. Magn Reson Med 69(2):486\u2013494. https:\/\/doi.org\/10.1002\/mrm.24280","journal-title":"Magn Reson Med"},{"issue":"5","key":"1196_CR23","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1002\/(SICI)1522-2594(199905)41:5<954::AID-MRM15>3.3.CO;2-A","volume":"41","author":"T Sch\u00e4ffter","year":"1999","unstructured":"Sch\u00e4ffter T, Rasche V, Carlsen IC (1999) Motion compensated projection reconstruction. Magn Reson Med 41(5):954\u2013963. https:\/\/doi.org\/10.1002\/(SICI)1522-2594(199905)41:5%3c954::AID-MRM15%3e3.3.CO;2-A","journal-title":"Magn Reson Med"},{"key":"1196_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fmed.2020.00215","volume":"7","author":"T Duan","year":"2020","unstructured":"Duan T et al (2020) Assessing liver function in liver tumors patients: the performance of T1 mapping and residual liver volume on Gd-EOBDTPA-enhanced MRI. Front Med 7:1\u201310. https:\/\/doi.org\/10.3389\/fmed.2020.00215","journal-title":"Front Med"},{"key":"1196_CR25","first-page":"295","volume-title":"MR linac radiotherapy","author":"M Michalet","year":"2022","unstructured":"Michalet M, Valdenaire S, Bordeau K, Azria D, Riou O (2022) MR-guided radiotherapy for liver tumors: hepatocarcinomas, cholangiocarcinomas, and liver metastases. In: Ozyar E, Onal C, Hackett A (eds) MR linac radiotherapy. Elsevier, Academic Press, pp 295\u2013314"},{"issue":"1","key":"1196_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-021-01813-6","volume":"16","author":"M Mayinger","year":"2021","unstructured":"Mayinger M et al (2021) Benefit of replanning in MR-guided online adaptive radiation therapy in the treatment of liver metastasis. Radiat Oncol 16(1):1\u20138. https:\/\/doi.org\/10.1186\/s13014-021-01813-6","journal-title":"Radiat Oncol"},{"issue":"1","key":"1196_CR27","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1002\/mrm.25102","volume":"73","author":"J Paul","year":"2015","unstructured":"Paul J et al (2015) High-resolution respiratory self-gated golden angle cardiac MRI: comparison of self-gating methods in combination with k-T SPARSE SENSE. Magn Reson Med 73(1):292\u2013298. https:\/\/doi.org\/10.1002\/mrm.25102","journal-title":"Magn Reson Med"},{"key":"1196_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphy.2022.836178","volume":"10","author":"P Metze","year":"2022","unstructured":"Metze P et al (2022) Non-uniform self-gating in 2D lung imaging. Front Phys 10:1\u201312. https:\/\/doi.org\/10.3389\/fphy.2022.836178","journal-title":"Front Phys"},{"issue":"1","key":"1196_CR29","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1002\/mrm.24628","volume":"71","author":"J Pang","year":"2014","unstructured":"Pang J et al (2014) Whole-heart coronary MRA with 100% respiratory gating efficiency: self-navigated three-dimensional retrospective image-based motion correction (TRIM). Magn Reson Med 71(1):67\u201374. https:\/\/doi.org\/10.1002\/mrm.24628","journal-title":"Magn Reson Med"},{"issue":"5","key":"1196_CR30","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1002\/mrm.20656","volume":"54","author":"PG Batchelor","year":"2005","unstructured":"Batchelor PG, Atkinson D, Irarrazaval P, Hill DLG, Hajnal J, Larkman D (2005) Matrix description of general motion correction applied to multishot images. Magn Reson Med 54(5):1273\u20131280","journal-title":"Magn Reson Med"},{"issue":"1","key":"1196_CR31","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1002\/mrm.21623","volume":"60","author":"F Odille","year":"2008","unstructured":"Odille F, Vuissoz PA, Marie PY, Felblinger J (2008) Generalized reconstruction by inversion of coupled systems (GRICS) applied to free-breathing MRI. Magn Reson Med 60(1):146\u2013157. https:\/\/doi.org\/10.1002\/mrm.21623","journal-title":"Magn Reson Med"},{"issue":"1","key":"1196_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/nbm.4409","volume":"34","author":"T K\u00fcstner","year":"2021","unstructured":"K\u00fcstner T et al (2021) Fully self-gated free-running 3D Cartesian cardiac CINE with isotropic whole-heart coverage in less than 2 min. NMR Biomed 34(1):1\u201313. https:\/\/doi.org\/10.1002\/nbm.4409","journal-title":"NMR Biomed"},{"issue":"2","key":"1196_CR33","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1002\/mrm.26745","volume":"79","author":"L Feng","year":"2018","unstructured":"Feng L et al (2018) 5D whole-heart sparse MRI. Magn Reson Med 79(2):826\u2013838. https:\/\/doi.org\/10.1002\/mrm.26745","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR34","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1002\/mrm.27935","volume":"83","author":"KM Becker","year":"2020","unstructured":"Becker KM et al (2020) Fast myocardial T1 mapping using cardiac motion correction. Magn Reson Med 83(2):438\u2013451. https:\/\/doi.org\/10.1002\/mrm.27935","journal-title":"Magn Reson Med"},{"issue":"1","key":"1196_CR35","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1109\/TMI.2006.885337","volume":"26","author":"S Winkelmann","year":"2007","unstructured":"Winkelmann S, Schaeffter T, Koehler T, Eggers H, Doessel O (2007) An optimal radial profile order based on the golden ratio for time-resolved MRI. IEEE Trans Med Imaging 26(1):68\u201376","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"1196_CR36","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/mrm.20110","volume":"52","author":"DR Messroghli","year":"2004","unstructured":"Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP (2004) Modified Look-Locker inversion recovery (MOLLI) for high-resolution T 1 mapping of the heart. Magn Reson Med 52(1):141\u2013146. https:\/\/doi.org\/10.1002\/mrm.20110","journal-title":"Magn Reson Med"},{"key":"1196_CR37","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1002\/mrm.1241","volume":"46","author":"KP Pruessmann","year":"2001","unstructured":"Pruessmann KP, Weiger M, Peter B, Boesiger P (2001) Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 46:638\u2013651","journal-title":"Magn Reson Med"},{"issue":"6","key":"1196_CR38","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1002\/mrm.21236","volume":"57","author":"KT Block","year":"2007","unstructured":"Block KT, Uecker M, Frahm J (2007) Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 57(6):1086\u20131098","journal-title":"Magn Reson Med"},{"issue":"8","key":"1196_CR39","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1109\/42.796284","volume":"18","author":"D Rueckert","year":"1999","unstructured":"Rueckert D, Sonoda LI, Hayes C, Hill DLG, Leach MO, Hawkes DJ (1999) Nonrigid registration using free-form deformations - application to breat MR images. IEEE Trans Med Imaging 18(8):712\u2013721","journal-title":"IEEE Trans Med Imaging"},{"key":"1196_CR40","unstructured":"M Modat, J McClelland, S Ourselin (2010) Lung registration using the NiftyReg package. MICCAI2010 workshop: medical image analysis for the clinic - a grand challenge. pp. 33\u201342"},{"issue":"2","key":"1196_CR41","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1002\/mrm.27474","volume":"81","author":"KM Becker","year":"2019","unstructured":"Becker KM, Schulz-Menger J, Schaeffter T, Kolbitsch C (2019) Simultaneous high-resolution cardiac T1 mapping and cine imaging using model-based iterative image reconstruction. Magn Reson Med 81(2):1080\u20131091","journal-title":"Magn Reson Med"},{"issue":"12","key":"1196_CR42","doi-asserted-by":"publisher","first-page":"10778","DOI":"10.3390\/s101210778","volume":"10","author":"F Thiel","year":"2010","unstructured":"Thiel F, Kosch O, Seifert F (2010) Ultra-wideband sensors for improved magnetic resonance imaging, cardiovascular monitoring and tumour diagnostics. Sensors 10(12):10778\u201310802. https:\/\/doi.org\/10.3390\/s101210778","journal-title":"Sensors"},{"issue":"6","key":"1196_CR43","doi-asserted-by":"publisher","first-page":"4308","DOI":"10.1007\/s00330-020-07447-8","volume":"31","author":"VC Obmann","year":"2021","unstructured":"Obmann VC et al (2021) T1 mapping of the liver and the spleen in patients with liver fibrosis\u2014does normalization to the blood pool increase the predictive value? Eur Radiol 31(6):4308\u20134318. https:\/\/doi.org\/10.1007\/s00330-020-07447-8","journal-title":"Eur Radiol"},{"key":"1196_CR44","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.mri.2016.12.021","volume":"38","author":"M Usman","year":"2017","unstructured":"Usman M, Ruijsink B, Nazir MS, Cruz G, Prieto C (2017) Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory. Magn Reson Imaging 38:129\u2013137. https:\/\/doi.org\/10.1016\/j.mri.2016.12.021","journal-title":"Magn Reson Imaging"},{"issue":"5","key":"1196_CR45","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1002\/mrm.1910340515","volume":"34","author":"V Rasche","year":"1995","unstructured":"Rasche V, De Boer RW, Holz D, Proksa R (1995) Continuous radial data acquisition for dynamic MRI. Magn Reson Med 34(5):754\u2013761. https:\/\/doi.org\/10.1002\/mrm.1910340515","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR46","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1002\/nbm.755","volume":"15","author":"JA D\u2019Arcy","year":"2002","unstructured":"D\u2019Arcy JA, Collins DJ, Rowland IJ, Padhani AR, Leach MO (2002) Applications of sliding window reconstruction with cartesian sampling for dynamic contrast enhanced MRI. NMR Biomed 15(2):174\u2013183. https:\/\/doi.org\/10.1002\/nbm.755","journal-title":"NMR Biomed"},{"key":"1196_CR47","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.media.2015.12.004","volume":"29","author":"W Huizinga","year":"2016","unstructured":"Huizinga W et al (2016) PCA-based groupwise image registration for quantitative MRI. Med Image Anal 29:65\u201378. https:\/\/doi.org\/10.1016\/j.media.2015.12.004","journal-title":"Med Image Anal"},{"key":"1196_CR48","doi-asserted-by":"publisher","first-page":"1047215","DOI":"10.3389\/fonc.2022.1047215","volume":"12","author":"J Zou","year":"2022","unstructured":"Zou J, Gao B, Song Y, Qin J (2022) A review of deep learning-based deformable medical image registration. Front Oncol 12:1047215. https:\/\/doi.org\/10.3389\/fonc.2022.1047215","journal-title":"Front Oncol"},{"key":"1196_CR49","volume-title":"Multiparametric cardiac magnetic resonance imaging with motion compensation","author":"KM Kerkering","year":"2020","unstructured":"Kerkering KM (2020) Multiparametric cardiac magnetic resonance imaging with motion compensation. Technische Universitaet Berlin, Berlin"},{"issue":"6","key":"1196_CR50","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58(6):1182\u20131195","journal-title":"Magn Reson Med"},{"key":"1196_CR51","doi-asserted-by":"publisher","first-page":"1524","DOI":"10.1002\/mrm.24600","volume":"70","author":"J Tran-Gia","year":"2013","unstructured":"Tran-Gia J, St\u00e4b D, Wech T, Hahn D, K\u00f6stler H (2013) Model-based acceleration of parameter mapping (MAP) for saturation prepared radially acquired data. Magn Reson Med 70:1524\u20131534","journal-title":"Magn Reson Med"},{"issue":"2","key":"1196_CR52","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1002\/mrm.29027","volume":"87","author":"G Cruz","year":"2022","unstructured":"Cruz G et al (2022) Generalized low-rank nonrigid motion-corrected reconstruction for MR fingerprinting. Magn Reson Med 87(2):746\u2013763. https:\/\/doi.org\/10.1002\/mrm.29027","journal-title":"Magn Reson Med"},{"issue":"1","key":"1196_CR53","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1148\/radiol.2016152037","volume":"279","author":"Y Chen","year":"2016","unstructured":"Chen Y et al (2016) MR fingerprinting for rapid quantitative abdominal imaging. Radiology 279(1):278\u2013286","journal-title":"Radiology"},{"issue":"7","key":"1196_CR54","doi-asserted-by":"publisher","first-page":"1983","DOI":"10.1148\/rg.2019190034","volume":"39","author":"FF Guglielmo","year":"2019","unstructured":"Guglielmo FF, Venkatesh SK, Mitchell DG (2019) Liver MR elastography technique and image interpretation: pearls and pitfalls. Radiographics 39(7):1983\u20132002. https:\/\/doi.org\/10.1148\/rg.2019190034","journal-title":"Radiographics"},{"issue":"4","key":"1196_CR55","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1002\/mrm.26216","volume":"77","author":"JI Hamilton","year":"2017","unstructured":"Hamilton JI et al (2017) MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density. Magn Reson Med 77(4):1446\u20131458","journal-title":"Magn Reson Med"},{"issue":"5","key":"1196_CR56","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1002\/mrm.28311","volume":"84","author":"O Jaubert","year":"2020","unstructured":"Jaubert O et al (2020) Multi-parametric liver tissue characterization using MR fingerprinting: simultaneous T1, T2, T2*, and fat fraction mapping. Magn Reson Med 84(5):2625\u20132635. https:\/\/doi.org\/10.1002\/mrm.28311","journal-title":"Magn Reson Med"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-024-01196-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10334-024-01196-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-024-01196-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T14:05:47Z","timestamp":1727100347000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10334-024-01196-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,12]]},"references-count":56,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["1196"],"URL":"https:\/\/doi.org\/10.1007\/s10334-024-01196-1","relation":{},"ISSN":["1352-8661"],"issn-type":[{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,12]]},"assertion":[{"value":"19 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}