{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T15:41:55Z","timestamp":1790696515800,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["422681845"],"award-info":[{"award-number":["422681845"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005971","name":"Deutsche Herzstiftung","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005971","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Berta Ottenstein Program"},{"name":"Universit\u00e4tsklinikum Freiburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>\n                      Developing a\n                      <jats:sup>19<\/jats:sup>\n                      F imaging method to acquire images of the molecular inflammation tracer perfluorooctyl bromide (PFOB) without chemical shift artifacts.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      PFOB is a molecular tracer that can be used to track the response of myeloid cells. However, imaging of PFOB with\n                      <jats:sup>19<\/jats:sup>\n                      F-MRI is challenging due to its complex spectrum which leads to unwanted chemical shift artifacts. Spectral HE allows for separate reconstructions of each peak of the PFOB spectrum, which was combined into a single image after resonance shift correction. In this work, a Hadamard-encoded (HE) radial 3D UTE sequence was tested in phantoms and in vivo in a pig, measuring the\n                      <jats:sup>19<\/jats:sup>\n                      F signal in the spleen at different times after injection.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Chemical shift artifacts were effectively suppressed with HE, and an SNR\u2009&gt;\u2009100 was observed for the\n                      <jats:sup>19<\/jats:sup>\n                      F signal in the spleen 2\u00a0days after injection. The signal decreased over time, and 7\u00a0days after injection it was reduced by 30%.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>\n                      Chemical shift artifact correction using HE allowed for in vivo\n                      <jats:sup>19<\/jats:sup>\n                      F PFOB imaging of labeled monocytes with a high SNR. Compared to spectrally selective excitation, HE increased the PFOB\n                      <jats:sup>19<\/jats:sup>\n                      F-MRI signal by 10%, and the simple HE-algorithm could be directly integrated into the image reconstruction of the MRI system.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10334-025-01254-2","type":"journal-article","created":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T06:22:24Z","timestamp":1748586144000},"page":"1011-1021","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Radial Hadamard-encoded 19F-MRI"],"prefix":"10.1007","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-6465-9528","authenticated-orcid":false,"given":"Kian","family":"Tadjalli Mehr","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1499-6163","authenticated-orcid":false,"given":"Johannes","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2929-9343","authenticated-orcid":false,"given":"Felix","family":"Spreter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2449-1679","authenticated-orcid":false,"given":"Simon","family":"Reiss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Boll","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3536-0826","authenticated-orcid":false,"given":"Ali Caglar","family":"\u00d6zen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8906-8850","authenticated-orcid":false,"given":"Deepa","family":"Gunashekar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constantin","family":"von zur M\u00fchlen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0200-7495","authenticated-orcid":false,"given":"Alexander","family":"Maier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9720-3506","authenticated-orcid":false,"given":"Michael","family":"Bock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,30]]},"reference":[{"key":"1254_CR1","doi-asserted-by":"publisher","DOI":"10.1038\/s41569-024-01009-x","author":"A Maier","year":"2024","unstructured":"Maier A, Teunissen AJP, Nauta SA, Lutgens E, Fayad ZA, van Leent MMT (2024) Uncovering atherosclerotic cardiovascular disease by PET imaging. Nat Rev Cardiol. https:\/\/doi.org\/10.1038\/s41569-024-01009-x","journal-title":"Nat Rev Cardiol"},{"key":"1254_CR2","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1038\/s41565-020-0642-4","volume":"15","author":"ML Senders","year":"2020","unstructured":"Senders ML, Meerwaldt AE, van Leent MMT, Sanchez-Gaytan BL, van de Voort JC, Toner YC, Maier A, Klein ED, Sullivan NAT, Sofias AM, Groenen H, Faries C, Oosterwijk RS, van Leeuwen EM, Fay F, Chepurko E, Reiner T, Duivenvoorden R, Zangi L, Dijkhuizen RM, Hak S, Swirski FK, Nahrendorf M, P\u00e9rez-Medina C, Teunissen AJP, Fayad ZA, Calcagno C, Strijkers GJ, Mulder WJM (2020) Probing myeloid cell dynamics in ischemic heart disease by nanotracer hot spot imaging. Nat Nanotechnol 15:398\u2013405","journal-title":"Nat Nanotechnol"},{"key":"1254_CR3","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCIMAGING.123.014742","volume":"16","author":"RB van Heeswijk","year":"2023","unstructured":"van Heeswijk RB, Bauer WR, B\u00f6nner F, Janjic JM, Mulder WJM, Schreiber LM, Schwitter J, Fl\u00f6gel U (2023) Cardiovascular molecular imaging with fluorine-19 MRI: the road to the clinic. Circ Cardiovasc Imaging 16:e014742","journal-title":"Circ Cardiovasc Imaging"},{"key":"1254_CR4","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1161\/CIRCULATIONAHA.107.737890","volume":"118","author":"U Fl\u00f6gel","year":"2008","unstructured":"Fl\u00f6gel U, Ding Z, Hardung H, Jander S, Reichmann G, Jacoby C, Schubert R, Schrader J (2008) In vivo monitoring of inflammation after cardiac and cerebral ischemia by fluorine magnetic resonance imaging. Circulation 118:140\u2013148","journal-title":"Circulation"},{"key":"1254_CR5","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/j.jacbts.2022.12.014","volume":"8","author":"A Maier","year":"2023","unstructured":"Maier A, Toner YC, Munitz J, Sullivan NAT, Sakurai K, Meerwaldt AE, Brechb\u00fchl EES, Pr\u00e9vot G, van Elsas Y, Maas RJF, Ranzenigo A, Soultanidis G, Rashidian M, P\u00e9rez-Medina C, Heo GS, Gropler RJ, Liu Y, Reiner T, Nahrendorf M, Swirski FK, Strijkers GJ, Teunissen AJP, Calcagno C, Fayad ZA, Mulder WJM, van Leent MMT (2023) Multiparametric immunoimaging maps inflammatory signatures in murine myocardial infarction models. JACC Basic Transl Sci 8:801\u2013816","journal-title":"JACC Basic Transl Sci"},{"key":"1254_CR6","doi-asserted-by":"publisher","first-page":"20230019","DOI":"10.1259\/bjro.20230019","volume":"5","author":"O Maxouri","year":"2023","unstructured":"Maxouri O, Bodalal Z, Daal M, Rostami S, Rodriguez I, Akkari L, Srinivas M, Bernards R, Beets-Tan R (2023) How to 19F MRI: applications, technique, and getting started. BJR|Open 5:20230019","journal-title":"BJR|Open"},{"key":"1254_CR7","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.tibtech.2010.04.002","volume":"28","author":"M Srinivas","year":"2010","unstructured":"Srinivas M, Heerschap A, Ahrens ET, Figdor CG, de Vries IJM (2010) 19F MRI for quantitative in vivo cell tracking. Trends Biotechnol 28:363\u2013370","journal-title":"Trends Biotechnol"},{"key":"1254_CR8","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1002\/nbm.3059","volume":"27","author":"C Jacoby","year":"2014","unstructured":"Jacoby C, Temme S, Mayenfels F, Benoit N, Krafft MP, Schubert R, Schrader J, Fl\u00f6gel U (2014) Probing different perfluorocarbons for in vivo inflammation imaging by 19F MRI: image reconstruction, biological half-lives and sensitivity. NMR Biomed 27:261\u2013271","journal-title":"NMR Biomed"},{"key":"1254_CR9","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1006\/jmrb.1995.1023","volume":"106","author":"HP Shukla","year":"1995","unstructured":"Shukla HP, Mason RP, Woessner DE, Antich PP (1995) A comparison of three commercial perfluorocarbon emulsions as high-field 19F NMR probes of oxygen tension and temperature. J Magn Reson B 106:131\u2013141","journal-title":"J Magn Reson B"},{"key":"1254_CR10","doi-asserted-by":"publisher","first-page":"2263","DOI":"10.1002\/mrm.26317","volume":"77","author":"R Colotti","year":"2017","unstructured":"Colotti R, Bastiaansen JAM, Wilson A, Fl\u00f6gel U, Gonzales C, Schwitter J, Stuber M, van Heeswijk RB (2017) Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla. Magn Reson Med 77:2263\u20132271","journal-title":"Magn Reson Med"},{"key":"1254_CR11","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s10334-018-0714-8","volume":"32","author":"M Rothe","year":"2019","unstructured":"Rothe M, Jahn A, Weiss K, Hwang J-H, Szendroedi J, Kelm M, Schrader J, Roden M, Fl\u00f6gel U, B\u00f6nner F (2019) In vivo 19F MR inflammation imaging after myocardial infarction in a large animal model at 3 T. Magma NY N 32:5\u201313","journal-title":"Magma NY N"},{"key":"1254_CR12","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s00395-022-00928-5","volume":"117","author":"F B\u00f6nner","year":"2022","unstructured":"B\u00f6nner F, Gastl M, Nienhaus F, Rothe M, Jahn A, Pfeiler S, Gross U, Schultheiss H-P, Ibanez B, Kozerke S, Szendroedi J, Roden M, Westenfeld R, Schrader J, Fl\u00f6gel U, Heusch G, Kelm M (2022) Regional analysis of inflammation and contractile function in reperfused acute myocardial infarction by in vivo 19F cardiovascular magnetic resonance in pigs. Basic Res Cardiol 117:21","journal-title":"Basic Res Cardiol"},{"key":"1254_CR13","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1002\/jmri.1880020110","volume":"2","author":"HK Lee","year":"1992","unstructured":"Lee HK, Nalcioglu O (1992) Reblurred deconvolution method for chemical shift removal in F-19 (PFOB) MR imaging. J Magn Reson Imaging JMRI 2:53\u201361","journal-title":"J Magn Reson Imaging JMRI"},{"key":"1254_CR14","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1097\/00004728-198809010-00020","volume":"12","author":"LJ Busse","year":"1988","unstructured":"Busse LJ, Pratt RG, Thomas SR (1988) Deconvolution of chemical shift spectra in two- or three-dimensional [19F] MR imaging. J Comput Assist Tomogr 12:824\u2013835","journal-title":"J Comput Assist Tomogr"},{"key":"1254_CR15","doi-asserted-by":"crossref","unstructured":"Chen J, Ahrens ET, Pal P (2023) Physics-driven learned deconvolution of multi-spectral cellular MRI with radial sampling. In: 2023 57th asilomar conf. signals syst. comput., pp 1453\u20131457","DOI":"10.1109\/IEEECONF59524.2023.10476927"},{"key":"1254_CR16","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.1002\/mrm.26874","volume":"79","author":"KD Ludwig","year":"2018","unstructured":"Ludwig KD, Hernando D, Roberts NT, van Heeswijk RB, Fain SB (2018) A chemical shift encoding (CSE) approach for spectral selection in fluorine-19 MRI. Magn Reson Med 79:2183\u20132189","journal-title":"Magn Reson Med"},{"key":"1254_CR17","doi-asserted-by":"publisher","first-page":"2724","DOI":"10.1002\/mrm.26895","volume":"79","author":"RB van Heeswijk","year":"2018","unstructured":"van Heeswijk RB, Colotti R, Dar\u00e7ot E, Delacoste J, Pellegrin M, Piccini D, Hernando D (2018) Chemical shift encoding (CSE) for sensitive fluorine-19 MRI of perfluorocarbons with complex spectra. Magn Reson Med 79:2724\u20132730","journal-title":"Magn Reson Med"},{"key":"1254_CR18","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1002\/mrm.27926","volume":"83","author":"J Schoormans","year":"2020","unstructured":"Schoormans J, Calcagno C, Daal MRR, W\u00fcst RCI, Faries C, Maier A, Teunissen AJP, Naidu S, Sanchez-Gaytan BL, Nederveen AJ, Fayad ZA, Mulder WJM, Coolen BF, Strijkers GJ (2020) An iterative sparse deconvolution method for simultaneous multicolor 19 F-MRI of multiple contrast agents. Magn Reson Med 83:228\u2013239","journal-title":"Magn Reson Med"},{"key":"1254_CR19","doi-asserted-by":"publisher","DOI":"10.58530\/2022\/1008","author":"M Bock","year":"2022","unstructured":"Bock M, Ilbey S, Maier A, \u00d6zen AC (2022) Chemical shift artifact correction for 19F MRI using spectral Hadamard encoding. Proc Intl Soc Mag Reson Med. https:\/\/doi.org\/10.58530\/2022\/1008","journal-title":"Proc Intl Soc Mag Reson Med"},{"key":"1254_CR20","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1006\/jmrb.1994.1078","volume":"104","author":"G Goelman","year":"1994","unstructured":"Goelman G (1994) Fast Hadamard Spectroscopic Imaging Techniques. J Magn Reson B 104:212\u2013218","journal-title":"J Magn Reson B"},{"key":"1254_CR21","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5086","volume":"37","author":"M Yildirim","year":"2024","unstructured":"Yildirim M, Kovalyk X, Scholtz P, Sch\u00fctz M, Lindemeyer J, Lamerichs R, Gr\u00fcll H, Isik EO (2024) Fast 19 F spectroscopic imaging with pseudo-spiral k-space sampling. NMR Biomed 37:e5086","journal-title":"NMR Biomed"},{"key":"1254_CR22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1002\/jmri.21895","volume":"31","author":"TA Bley","year":"2010","unstructured":"Bley TA, Wieben O, Fran\u00e7ois CJ, Brittain JH, Reeder SB (2010) Fat and water magnetic resonance imaging. J Magn Reson Imaging 31:4\u201318","journal-title":"J Magn Reson Imaging"},{"key":"1254_CR23","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1016\/S0730-725X(99)00098-3","volume":"17","author":"DW Fletcher","year":"1999","unstructured":"Fletcher DW, Haselgrove JC, Bolinger L (1999) High-resolution imaging using Hadamard encoding. Magn Reson Imaging 17:1457\u20131468","journal-title":"Magn Reson Imaging"},{"key":"1254_CR24","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1097\/00004728-198811000-00021","volume":"12","author":"SP Souza","year":"1988","unstructured":"Souza SP, Szumowski J, Dumoulin CL, Plewes DP, Glover G (1988) SIMA: simultaneous multislice acquisition of MR images by Hadamard-encoded excitation. J Comput Assist Tomogr 12:1026\u20131030","journal-title":"J Comput Assist Tomogr"},{"key":"1254_CR25","volume-title":"Handbook of MRI Pulse Sequences","author":"MA Bernstein","year":"2004","unstructured":"Bernstein MA, King KF, Zhou XJ (2004) Handbook of MRI Pulse Sequences. Academic Press, Amsterdam, Boston"},{"key":"1254_CR26","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1002\/mrm.22898","volume":"66","author":"D Piccini","year":"2011","unstructured":"Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO (2011) Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI. Magn Reson Med 66:1049\u20131056","journal-title":"Magn Reson Med"},{"key":"1254_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2021.106977","volume":"327","author":"X Zhu","year":"2021","unstructured":"Zhu X, Tan F, Johnson K, Larson P (2021) Optimizing trajectory ordering for fast radial ultra-short TE (UTE) acquisitions. J Magn Reson 327:106977","journal-title":"J Magn Reson"},{"key":"1254_CR28","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1002\/mrm.29490","volume":"89","author":"AC \u00d6zen","year":"2023","unstructured":"\u00d6zen AC, Spreter F, Schimpf W, Fischer J, Ilbey S, Reiss S, Maier A, von Elverfeldt D, Heidt T, von Zur MC, Bock M (2023) Scalable and modular 8-channel transmit and 8-channel flexible receive coil array for 19 F MRI of large animals. Magn Reson Med 89:1237\u20131250","journal-title":"Magn Reson Med"},{"key":"1254_CR29","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1002\/jmri.20969","volume":"26","author":"O Dietrich","year":"2007","unstructured":"Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375\u2013385","journal-title":"J Magn Reson Imaging"},{"key":"1254_CR30","doi-asserted-by":"publisher","first-page":"2225","DOI":"10.1002\/mrm.25370","volume":"73","author":"M Meissner","year":"2015","unstructured":"Meissner M, Reisert M, Hugger T, Hennig J, von Elverfeldt D, Leupold J (2015) Revealing signal from noisy (19) F MR images by chemical shift artifact correction. Magn Reson Med 73:2225\u20132233","journal-title":"Magn Reson Med"},{"key":"1254_CR31","doi-asserted-by":"publisher","first-page":"8663","DOI":"10.1038\/s41598-019-45154-7","volume":"9","author":"T Heidt","year":"2019","unstructured":"Heidt T, Reiss S, Krafft AJ, \u00d6zen AC, Lottner T, Hehrlein C, Galmbacher R, Kayser G, Hilgendorf I, Stachon P, Wolf D, Zirlik A, D\u00fcring K, Zehender M, Meckel S, von Elverfeldt D, Bode C, Bock M, von zur M\u00fchlen C (2019) Real-time magnetic resonance imaging\u2014guided coronary intervention in a porcine model. Sci Rep 9:8663","journal-title":"Sci Rep"},{"key":"1254_CR32","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4212","volume":"33","author":"E Dar\u00e7ot","year":"2020","unstructured":"Dar\u00e7ot E, Colotti R, Brennan D, Deuchar GA, Santosh C, van Heeswijk RB (2020) A characterization of ABL-101 as a potential tracer for clinical fluorine-19 MRI. NMR Biomed 33:e4212","journal-title":"NMR Biomed"},{"key":"1254_CR33","doi-asserted-by":"publisher","first-page":"1869","DOI":"10.1038\/s41598-024-52376-x","volume":"14","author":"F Meissner","year":"2024","unstructured":"Meissner F, Galbas MC, Szvetics S, von zur M\u00fchlen C, Heidt T, Maier A, Bock M, Czerny M, Bothe W, Reiss S (2024) Cardioaortic dimensions in German landrace pigs derived from cardiac magnetic resonance imaging. Sci Rep 14:1869","journal-title":"Sci Rep"},{"key":"1254_CR34","doi-asserted-by":"publisher","first-page":"20581","DOI":"10.1109\/ACCESS.2022.3151804","volume":"10","author":"AC \u00d6zen","year":"2022","unstructured":"\u00d6zen AC, Lottner T, Reiss S, Heidt T, Zur M\u00fchlen CV, Bock M (2022) Real-time control of active catheter signals for better visual profiling during cardiovascular interventions under MRI guidance. IEEE Access 10:20581\u201320589","journal-title":"IEEE Access"},{"key":"1254_CR35","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1002\/mrm.10664","volume":"51","author":"AC Larson","year":"2004","unstructured":"Larson AC, White RD, Laub G, McVeigh ER, Li D, Simonetti OP (2004) Self-gated cardiac cine MRI. Magn Reson Med 51:93\u2013102","journal-title":"Magn Reson Med"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-025-01254-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10334-025-01254-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-025-01254-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T04:40:26Z","timestamp":1763700026000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10334-025-01254-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":35,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1254"],"URL":"https:\/\/doi.org\/10.1007\/s10334-025-01254-2","relation":{},"ISSN":["1352-8661"],"issn-type":[{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,30]]},"assertion":[{"value":"2 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The animal experiment was conducted in accordance with FELASA and GV-SOLAS standards for animal welfare. Experiments were approved by the local ethics committee of Freiburg University and the regional council of Freiburg, Baden-Wuerttemberg, Germany (licence number 35-9185.81\/G-23\/012).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}