{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T13:55:56Z","timestamp":1781358956295,"version":"3.54.1"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Magn Reson Mater Phy"],"DOI":"10.1007\/s10334-026-01373-4","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T13:50:28Z","timestamp":1781358628000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Hazards associated with superconducting magnet quench events: system requirements, application and consequences"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6854-9348","authenticated-orcid":false,"given":"Michael","family":"Steckner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"key":"1373_CR1","unstructured":"https:\/\/www.cnn.com\/2025\/07\/20\/health\/mri-machine-death-long-island (retrieved: 7\/27\/2025)"},{"key":"1373_CR2","unstructured":"https:\/\/patch.com\/california\/redwoodcity-woodside\/nurse-crushed-between-metal-bed-magnetic-mri-machine-reports (retrieved: 7\/27\/2025)"},{"key":"1373_CR3","unstructured":"https:\/\/mumbaimirror.indiatimes.com\/mumbai\/cover-story\/Two-stuck-to-MRI-machine-for-4-hrs\/articleshow\/45103043.html (retrieved: 7\/27\/2025)"},{"key":"1373_CR4","unstructured":"IEC 60601-2-33 Medical electrical equipment\u2014Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis. Edition 4.0 2022."},{"key":"1373_CR5","unstructured":"Padfield R, Stapleton G. Truck Crashes into MRI Facility. Fire Engineering. Published online September 2015. https:\/\/www.fireengineering.com\/fire-apparatus\/truck-crashes-into-mri-facility\/ (retrieved: 7\/27\/2025)"},{"key":"1373_CR6","unstructured":"https:\/\/www.hampshirechronicle.co.uk\/news\/mainstories\/9866186.winchester-hospital-set-to-replace-800000-mri-scanner-destroyed-in-last-years-fire\/ (retrieved: 7\/27\/2025)"},{"key":"1373_CR7","doi-asserted-by":"publisher","unstructured":"Bottura L. Magnet Quench 101. 2013 In: WAMSDO: Workshop on Accelerator Magnet Superconductors, Design and Optimization. 1\u20139. https:\/\/doi.org\/10.5170\/CERN-2013-006.1","DOI":"10.5170\/CERN-2013-006.1"},{"key":"1373_CR8","unstructured":"https:\/\/www.bbc.com\/future\/article\/20250331-why-helium-shortages-are-worrying-the-world (retrieved: 7\/27\/2025)"},{"key":"1373_CR9","unstructured":"https:\/\/home.ecri.org\/blogs\/impact-stories\/costly-mri-malfunctions-eliminated-by-ecri"},{"issue":"3","key":"1373_CR10","doi-asserted-by":"publisher","first-page":"2104","DOI":"10.1109\/TASC.2010.2084981","volume":"21","author":"TC Cosmus","year":"2011","unstructured":"Cosmus TC, Parizh M (2011) Advances in whole-body MRI magnets. IEEE Trans Appl Supercond 21(3):2104\u20132109. https:\/\/doi.org\/10.1109\/TASC.2010.2084981","journal-title":"IEEE Trans Appl Supercond"},{"key":"1373_CR11","unstructured":"Zhang R, Liu F, Wang X, Crozier S. Influence of Protection Circuit on Quench Characteristics for Clinical MRI Superconducting Magnets. ISMRM 2011:1831."},{"key":"1373_CR12","unstructured":"Huang X, Eckels PW. Patent US6147844. Quench protection for persistant superconducting magnets for magnetic resonance imaging. Published online November 14, 2000. Accessed August 20, 2025. https:\/\/patents.google.com\/patent\/US6147844A (retrieved: 7\/27\/2025)"},{"key":"1373_CR13","unstructured":"Murphy M, Hobday P. Active-shield superconducting magnets for MRI. Proceedings of the Society of Magnetic Resonance in Medicine 1987:817."},{"key":"1373_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.29665","author":"M Steckner","year":"2024","unstructured":"Steckner M (2024) A review of MRI acoustic noise outputs and hearing protection device performance. Magn Reson Imaging. https:\/\/doi.org\/10.1002\/jmri.29665","journal-title":"Magn Reson Imaging"},{"key":"1373_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-025-01310-x","author":"MC Steckner","year":"2025","unstructured":"Steckner MC, Ashmore J, Charles-Edwards G et al (2025) Commentary: the MRI scanner room door is a latent safety issue. Magn Reson Mater Phy. https:\/\/doi.org\/10.1007\/s10334-025-01310-x","journal-title":"Magn Reson Mater Phy"},{"key":"1373_CR16","unstructured":"SLAC Environment, Safety, and Health Manual: Chapter 36 Cryogenic Requirements. Published online 2022. https:\/\/www-group.slac.stanford.edu\/esh\/eshmanual\/references\/cryogenicsReqCryogenic.pdf"},{"key":"1373_CR17","unstructured":"MHRA Medical Device Alert. MDA\/2003\/014. Static MRI scanners with quench vent pipes. Reference number 20021113.018\u20138. Issued: 09 May 2003. Available at: https:\/\/webarchive.nationalarchives.gov.uk\/ukgwa\/20090705130853\/http:\/www.mhra.gov.uk\/PrintPreview\/PublicationSP\/CON008663 (retrieved: 7\/27\/2025)"},{"issue":"1","key":"1373_CR18","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1002\/mrm.1910030114","volume":"3","author":"PJ Bore","year":"1986","unstructured":"Bore PJ, Galloway GJ, Styles P, Radda GK, Flynn G, Pitts PR (1986) Are quenches dangerous? Magn Reson Med 3(1):112\u2013117","journal-title":"Magn Reson Med"},{"key":"1373_CR19","unstructured":"USA Code of Federal Regulations 14 CFR \u00a7 91.211 - Supplemental oxygen. https:\/\/www.law.cornell.edu\/cfr\/text\/14\/91.211 (retrieved: 7\/27\/2025)"},{"key":"1373_CR20","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.665821","volume":"12","author":"DM Shaw","year":"2021","unstructured":"Shaw DM, Cabre G, Gant N (2021) Hypoxic hypoxia and brain function in Military Aviation: basic physiology and applied perspectives. Front Physiol 12:665821. https:\/\/doi.org\/10.3389\/fphys.2021.665821","journal-title":"Front Physiol"},{"issue":"1","key":"1373_CR21","doi-asserted-by":"publisher","first-page":"54","DOI":"10.3357\/AMHP.6338.2023","volume":"95","author":"BD Cox","year":"2024","unstructured":"Cox BD, McHail DG, Blacker KJ (2024) Personal hypoxia symptoms vary widely within individuals. Aerosp Med Hum Perform 95(1):54\u201358. https:\/\/doi.org\/10.3357\/AMHP.6338.2023","journal-title":"Aerosp Med Hum Perform"},{"key":"1373_CR22","unstructured":"American College of Radiology. 2024 ACR Manual on MR Safety. https:\/\/edge.sitecorecloud.io\/americancoldf5f-acrorgf92a-productioncb02-3650\/media\/ACR\/Files\/Clinical\/Radiology-Safety\/Manual-on-MR-Safety.pdf (retrieved: 7\/27\/2025)"},{"key":"1373_CR23","unstructured":"NHS. Health Technical Memorandum 03-01 Specialised ventilation for healthcare premises Part A: The concept, design, specification, installation and acceptance testing of healthcare ventilation systems. Published online 2021. https:\/\/www.england.nhs.uk\/wp-content\/uploads\/2021\/05\/HTM0301-PartA-accessible-F6.pdf"},{"issue":"4","key":"1373_CR24","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ab2300","volume":"5","author":"N Pace","year":"2019","unstructured":"Pace N, Ricci L, Scotoni M, Perinelli A, Jovicich J (2019) Characterization of time-varying magnetic fields and temperature of helium gas exit during a quench of a human magnetic resonance system. Biomed Phys Eng Express 5(4):045021. https:\/\/doi.org\/10.1088\/2057-1976\/ab2300","journal-title":"Biomed Phys Eng Express"},{"key":"1373_CR25","volume-title":"The Feynman lectures on physics","author":"RP Feynman","year":"2011","unstructured":"Feynman RP (2011) The Feynman lectures on physics. Basic Books, The new millennium edition"},{"key":"1373_CR26","unstructured":"https:\/\/www.ifixit.com\/News\/11986\/iphones-are-allergic-to-helium (retrieved: 7\/27\/2025)"},{"key":"1373_CR27","doi-asserted-by":"publisher","DOI":"10.1097\/JU.0000000000000860.08","volume":"203","author":"A Pluchino","year":"2020","unstructured":"Pluchino A, Lopez A, Angulo F, Gonzalez P, Cohen D, Bianco F (2020) PD17-08 thawing process during cryoablation with helium disables IPHONES and IWATCHES devices. J Urol 203:e372. https:\/\/doi.org\/10.1097\/JU.0000000000000860.08","journal-title":"J Urol"},{"key":"1373_CR28","unstructured":"Shrivastava ED, Thomas J, Ashbrook ES, et al. Safety and Biological Effects in MRI. 2021 John Wiley & Sons Ltd. ISBN 978-1-118-82130-5"},{"issue":"4","key":"1373_CR29","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1118\/1.596827","volume":"19","author":"JF Schenck","year":"1992","unstructured":"Schenck JF, Dumoulin CL, Redington RW, Kressel HY, Elliott RT, McDougall IL (1992) Human exposure to 4.0-Tesla magnetic fields in a whole-body scanner. Med Phys 19(4):1089\u20131098. https:\/\/doi.org\/10.1118\/1.596827","journal-title":"Med Phys"},{"key":"1373_CR30","unstructured":"MHRA. Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use. Published online December 2007. https:\/\/www.gov.uk\/government\/publications\/safety-guidelines-for-magnetic-resonance-imaging-equipment-in-clinical-use (retrieved: 7\/27\/2025)"},{"key":"1373_CR31","unstructured":"https:\/\/www.youtube.com\/watch?v=6-sxe79Y5Nc (retrieved: 7\/27\/2025)"},{"key":"1373_CR32","unstructured":"https:\/\/www.kfv-schweinfurt.de\/index.php\/aktuelles\/nachrichten-aus-dem-kfv\/nachrichtenarchiv\/item\/1273-schwerer-unfall-beim-brandeinsatz-der-feuerwehr-eisenhaltiges-material-im-mrt"},{"key":"1373_CR33","unstructured":"Watson RE. MRI Safety Events: Lessons Learned. ISMRM 2013:7415."},{"issue":"3","key":"1373_CR34","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1007\/s10334-023-01089-9","volume":"36","author":"C Guenthner","year":"2023","unstructured":"Guenthner C, Peereboom SM, Dillinger H et al (2023) Ramping down a clinical 3 T scanner: a journey into MRI and MRS at 0.75 T. Magn Reson Mater Phy 36(3):355\u2013373. https:\/\/doi.org\/10.1007\/s10334-023-01089-9","journal-title":"Magn Reson Mater Phy"},{"key":"1373_CR35","unstructured":"General Electric. Principles of MR Suite Safety for GE Healthcare https:\/\/hls2.gehealthcare.com\/content\/unfiltered\/service\/cm\/6002\/student\/GE-EHS-492%20Principles%20of%20MR%20Safety.pdf (retrieved: 7\/27\/2025)"},{"key":"1373_CR36","first-page":"243","volume":"7","author":"WM Kelly","year":"1986","unstructured":"Kelly WM, Paglen PG, Pearson JA, Diego AGS, Soloman MA (1986) Ferromagnetism of intraocular foreign body causes unilateral blindness after MR study. Am J Neuroradiol 7:243\u2013245","journal-title":"Am J Neuroradiol"},{"key":"1373_CR37","doi-asserted-by":"publisher","unstructured":"ASTM F2213-17 (2017) Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment. https:\/\/doi.org\/10.1520\/F2213-17","DOI":"10.1520\/F2213-17"},{"issue":"1","key":"1373_CR38","first-page":"301","volume":"13","author":"DF Sobel","year":"1992","unstructured":"Sobel DF, Larsen M, Zyroff J et al (1992) Buffing up MR images. AJNR Am J Neuroradiol 13(1):301\u2013302","journal-title":"AJNR Am J Neuroradiol"},{"key":"1373_CR39","unstructured":"Boiteaux S. 2025 ISMRT\/ISMRM Joint Forum \u201cFlooding in an MRI emergency: A Florida Case Study\u201d"},{"key":"1373_CR40","unstructured":"Stuppino JJ, Large & Small Animal Imaging. ISMRT 2016."},{"key":"1373_CR41","unstructured":"https:\/\/www.youtube.com\/watch?v=1R7KsfosV-o (retrieved: 7\/27\/2025)"},{"key":"1373_CR42","unstructured":"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfmaude\/search.cfm"},{"key":"1373_CR43","unstructured":"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/TextSearch.cfm"},{"key":"1373_CR44","unstructured":"https:\/\/www.fda.gov\/medical-devices\/medical-device-reporting-mdr-how-report-medical-device-problems\/mdr-data-files"},{"key":"1373_CR45","unstructured":"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfRES\/res.cfm"},{"key":"1373_CR46","unstructured":"https:\/\/www.fda.gov\/safety\/recalls-market-withdrawals-safety-alerts"},{"key":"1373_CR47","unstructured":"https:\/\/wayback.archive-it.org\/7993\/20201217182838\/https:\/\/www.fda.gov\/safety\/recalls-market-withdrawals-safety-alerts\/archive-recalls-market-withdrawals-safety-alerts"},{"key":"1373_CR48","unstructured":"https:\/\/www.fda.gov\/safety\/fda-adverse-event-monitoring-system-aems"},{"key":"1373_CR49","unstructured":"Soeldner L, Davies F. Patent US5329266. Magnet assembly. Published online July 12, 1994. Accessed August 22, 2025. https:\/\/patents.google.com\/patent\/US5329266A\/en (retrieved: 7\/27\/2025)"}],"container-title":["Magnetic Resonance Materials in Physics, Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-026-01373-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10334-026-01373-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10334-026-01373-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T13:50:37Z","timestamp":1781358637000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10334-026-01373-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,13]]},"references-count":49,"alternative-id":["1373"],"URL":"https:\/\/doi.org\/10.1007\/s10334-026-01373-4","relation":{},"ISSN":["1352-8661"],"issn-type":[{"value":"1352-8661","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,13]]},"assertion":[{"value":"31 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"There are no conflict of interest related to this paper.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval required for this paper given no experimental data was collected for\nthis paper.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}