{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T17:21:55Z","timestamp":1791048115840,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2008,9,1]],"date-time":"2008-09-01T00:00:00Z","timestamp":1220227200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Jpn J Ophthalmol"],"published-print":{"date-parts":[[2008,9]]},"DOI":"10.1007\/s10384-008-0570-6","type":"journal-article","created":{"date-parts":[[2008,11,10]],"date-time":"2008-11-10T01:37:39Z","timestamp":1226281059000},"page":"363-367","source":"Crossref","is-referenced-by-count":31,"title":["Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery"],"prefix":"10.1007","volume":"52","author":[{"given":"Minehiro","family":"Takimoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyuki","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,9,1]]},"reference":[{"key":"570_CR1","first-page":"265","volume":"3","author":"U.F.C. Legler","year":"1994","unstructured":"Legler UFC, Witschel BM. The capsular ring: a new device for complicated cataract surgery. Ger J Ophthalmol 1994;3:265.","journal-title":"Ger J Ophthalmol"},{"key":"570_CR2","first-page":"358","volume":"22","author":"T. Hara","year":"1991","unstructured":"Hara T, Hara T, Yamada Y. \u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal. Ophthalmic Surg 1991;22:358\u2013359.","journal-title":"Ophthalmic Surg"},{"key":"570_CR3","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0886-3350(13)80126-5","volume":"21","author":"R.J. Cionni","year":"1995","unstructured":"Cionni RJ, Osher RH. Endocapsular ring approach to the subluxated cataractous lens. J Cataract Refract Surg 1995;21:245\u2013249.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR4","doi-asserted-by":"crossref","first-page":"273","DOI":"10.3928\/1542-8877-19970401-03","volume":"28","author":"H.V. Gimbel","year":"1997","unstructured":"Gimbel HV, Sun R, Heston JP. Management of zonular dialysis in phacoemulsification and IOL implantation using the capsular tension ring. Ophthalmic Surg Lasers 1997;28:273\u2013281.","journal-title":"Ophthalmic Surg Lasers"},{"key":"570_CR5","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1016\/S0886-3350(00)00446-6","volume":"26","author":"R. Menapace","year":"2000","unstructured":"Menapace R, Findl O, Georgopoulos M, Rainer G, Vass C, Schmetterer K. The capsular tension ring: designs, applications, and techniques. J Cataract Refract Surg 2000;26:898\u2013912.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR6","doi-asserted-by":"crossref","first-page":"502","DOI":"10.3928\/1542-8877-19980601-12","volume":"29","author":"R. Sun","year":"1998","unstructured":"Sun R, Gimbel HV. In vitro evaluation of the efficacy of the capsular tension ring for managing zonular dialysis in cataract surgery. Ophthalmic Surg Lasers 1998;29:502\u2013505.","journal-title":"Ophthalmic Surg Lasers"},{"key":"570_CR7","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/S0886-3350(00)00610-6","volume":"27","author":"D.H. Lee","year":"2001","unstructured":"Lee DH, Lee HY, Lee KH, Chung KH, Joo C-K. Effect of a capsular tension ring on the shape of the capsular bag and opening and the intraocular lens. J Cataract Refract Surg 2001;27:452\u2013456.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR8","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.1016\/j.jcrs.2006.05.012","volume":"32","author":"S. Kurtz","year":"2006","unstructured":"Kurtz S, Krummenauer F, Dumbach C, Pfeiffer N, Dick HB. Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery. J Cataract Refract Surg 2006;32:1615\u20131620.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR9","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1016\/S0886-3350(97)80027-2","volume":"23","author":"K. Strenn","year":"1997","unstructured":"Strenn K, Menapace R, Vass C. Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ring. J Cataract Refract Surg 1997;23:1543\u20131547.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR10","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/S0886-3350(02)01534-1","volume":"29","author":"S. Jacob","year":"2003","unstructured":"Jacob S, Agarwal A, Agarwal A, Agarwal S, Patel N, Lal V. Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis. J Cataract Refract Surg 2003;29:315\u2013321.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR11","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.ophtha.2004.09.022","volume":"112","author":"F.W. Price Jr","year":"2005","unstructured":"Price FW Jr, Maxkool RJ, Miller KM, Koch P, Oetting TA, Johnson AT. Interim results of the United States investigational device study of the Ophtec capsular tension ring. Ophthalmology 2005;112:460\u2013465.","journal-title":"Ophthalmology"},{"key":"570_CR12","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1016\/S0886-3350(01)01174-9","volume":"28","author":"D.H. Lee","year":"2002","unstructured":"Lee DH, Shin SC, Joo CK. Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery. J Cataract Refract Surg 2002;28:843\u2013846.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR13","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1016\/S0886-3350(99)00070-X","volume":"25","author":"C.W. Faschinger","year":"1999","unstructured":"Faschinger CW, Eckhardt M. Complete capsulorhexis opening occlusion despite capsular tension ring implantation. J Cataract Refract Surg 1999;25:1013\u20131015.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR14","doi-asserted-by":"publisher","first-page":"1688","DOI":"10.1016\/S0886-3350(01)00766-0","volume":"27","author":"K. Waheed","year":"2001","unstructured":"Waheed K, Eleftheriadis H, Liu C. Anterior capsular phimosis in eyes with a capsular tension ring. J Cataract Refract Surg 2001;27:1688\u20131690.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR15","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1016\/S0886-3350(01)01231-7","volume":"28","author":"J. Moreno-Montanes","year":"2002","unstructured":"Moreno-Montanes J, Sanchez-Tocino H, Rodriguez-Conde R. Complete anterior capsule contraction after phacoemulsification with acrylic intraocular lens and endocapsular ring implantation. J Cataract Refract Surg 2002;28:717\u2013719.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR16","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.ajo.2007.04.044","volume":"144","author":"K. Hayashi","year":"2007","unstructured":"Hayashi K, Hayashi H. Influence on posterior capsule opacification and visual function of intraocular lens optic material. Am J Ophthalmol 2007;144:195\u2013202.","journal-title":"Am J Ophthalmol"},{"key":"570_CR17","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/S0161-6420(97)30231-0","volume":"104","author":"K. Hayashi","year":"1997","unstructured":"Hayashi K, Harada M, Hayashi H, Nakao F, Hayashi F. Decentration and tilt of polymethyl methacrylate, silicone, and acrylic soft intraocular lenses. Ophthalmology 1997;104:793\u2013798.","journal-title":"Ophthalmology"},{"key":"570_CR18","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1016\/S0161-6420(98)97028-2","volume":"105","author":"K. Hayashi","year":"1998","unstructured":"Hayashi K, Hayashi H, Matsuo K, Nakao F, Hayashi F. Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa. Ophthalmology 1998;105:1239\u20131243.","journal-title":"Ophthalmology"},{"key":"570_CR19","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/S0002-9394(14)70169-2","volume":"123","author":"K. Hayashi","year":"1997","unstructured":"Hayashi K, Hayashi H, Nakao F, Hayashi F. Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Am J Ophthalmol 1997;123:441\u2013447.","journal-title":"Am J Ophthalmol"},{"key":"570_CR20","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1016\/S0886-3350(01)00787-8","volume":"27","author":"H. Hayashi","year":"2001","unstructured":"Hayashi H, Hayashi K, Nakao F, Hayashi F. Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation. J Cataract Refract Surg 2001;27:817\u2013824.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR21","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.jcrs.2004.06.042","volume":"31","author":"K. Hayashi","year":"2005","unstructured":"Hayashi K, Hayashi H. Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg 2005;31:337\u2013342.","journal-title":"J Cataract Refract Surg"},{"key":"570_CR22","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.ophtha.2004.11.013","volume":"112","author":"K. Hayashi","year":"2005","unstructured":"Hayashi K, Hayashi H. Intraocular lens factors that may affect anterior capsule contraction. Ophthalmology 2005;112:286\u2013292.","journal-title":"Ophthalmology"},{"key":"570_CR23","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1016\/j.jcrs.2006.06.009","volume":"32","author":"J.A. Boomer","year":"2006","unstructured":"Boomer JA, Jackson DW. Effect of the Morcher capsular tension ring on refractive outcome. J Cataract Refract Surg 2006;32:1180\u20131183.","journal-title":"J Cataract Refract Surg"}],"container-title":["Japanese Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-008-0570-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10384-008-0570-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-008-0570-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-008-0570-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,20]],"date-time":"2021-09-20T05:51:39Z","timestamp":1632117099000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10384-008-0570-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,9]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2008,9]]}},"alternative-id":["570"],"URL":"https:\/\/doi.org\/10.1007\/s10384-008-0570-6","relation":{},"ISSN":["0021-5155","1613-2246"],"issn-type":[{"value":"0021-5155","type":"print"},{"value":"1613-2246","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,9]]}}}