{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T13:05:38Z","timestamp":1788959138500,"version":"build-2803163510"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,18]],"date-time":"2024-03-18T00:00:00Z","timestamp":1710720000000},"content-version":"vor","delay-in-days":17,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Ophthalmol"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To report aging-associated change rates in circumpapillary retinal nerve fiber layer thickness (cpRNFLT) and macular ganglion cell-inner plexiform layer and complex thickness (MGCIPLT, MGCCT) in normal Japanese eyes and to compare the data in linear scaled visual field (VF) sensitivity of central 4 points of Humphrey Field Analyzer (HFA) 24-2 test (VF<jats:sub>4TestPoints<\/jats:sub>) to that in MGCIPLT in four 0.6-mm-diameter circles corresponding to the four central points of HFA 24-2 adjusted for retinal ganglion cell displacement (GCIPLT<jats:sub>4TestPoints<\/jats:sub>).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Study design<\/jats:title>\n                <jats:p>Prospective observational study<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>HFA 24-2 tests and spectral-domain optical coherence tomography (SD-OCT) measurements of cpRNFLT, MGCIPLT, MGCCT and GCIPLT<jats:sub>4TestPoints<\/jats:sub> were performed every 3 months for 3 years in 73 eyes of 37 healthy Japanese with mean age of 50.4 years. The time changes of SD-OCT-measured parameters and VF<jats:sub>4TestPoints<\/jats:sub> were analyzed using a linear mixed model.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The aging-associated change rates were -0.064 \u03bcm\/year for MGCIPLT and and -0.095 for MGCCT (P=0.020 and 0.017), but could not be detected for cpRNFLT. They accelerated with aging at -0.009\u03bcm\/year\/year of age for MGCIPLT (P&lt;0.001), at 0.011 for MGCCT (P&lt;0.001) and at 0.013 for cpRNFLT(0.031). The aging-associated decline of -82.1 [1\/Lambert]\/year of VF<jats:sub>4TestPoints<\/jats:sub> corresponded to -0.095 \u03bcm\/year of GCIPLT<jats:sub>4TestPoints<\/jats:sub>.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>We report that aging-associated change rates of cpRNFLT, MGCIPLT and MGCCT in normal Japanese eyes were found to be significantly accelerated along with aging. Relationship between VF sensitivity decline rates and SD-OCT measured GCIPLT decline rates during physiological aging in the corresponding parafoveal retinal areas are also documented.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10384-024-01049-3","type":"journal-article","created":{"date-parts":[[2024,3,18]],"date-time":"2024-03-18T06:02:00Z","timestamp":1710741720000},"page":"117-125","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Aging-associated changes of optical coherence tomography-measured ganglion cell-related retinal layer thickness and visual sensitivity in normal Japanese"],"prefix":"10.1007","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5950-4260","authenticated-orcid":false,"given":"Aiko","family":"Iwase","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomomi","family":"Higashide","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Fujii","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuko","family":"Ohno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsutomu","family":"Kikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Araie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,18]]},"reference":[{"key":"1049_CR1","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/0002-9394(84)90509-9","volume":"97","author":"AG Balazsi","year":"1984","unstructured":"Balazsi AG, Rootman J, Drance SM, Schulzer M, Douglas GR. The effect of age on the nerve fiber population of the human optic nerve. Am J Ophthalmol. 1984;97:760\u20136.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR2","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/S0161-6420(89)32928-9","volume":"96","author":"MX Repka","year":"1989","unstructured":"Repka MX, Quigley HA. The effect of age on normal human optic nerve fiber number and diameter. Ophthalmology. 1989;96:26\u201332.","journal-title":"Ophthalmology"},{"key":"1049_CR3","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/S0161-6420(89)32718-7","volume":"96","author":"FS Mikelberg","year":"1989","unstructured":"Mikelberg FS, Drance SM, Schulzer M, Yidegiligne H, Weis MM. The normal human optic nerve. Axon count and axon diameter distribution. Ophthalmology. 1989;96:1125\u20138.","journal-title":"Ophthalmology"},{"key":"1049_CR4","first-page":"2012","volume":"33","author":"JB Jonas","year":"1992","unstructured":"Jonas JB, Schmidt AM, M\u00fcller-Bergh JA, Shlotzer-Schrehardt UM, Naumann GO. Human optic nerve fiber count and optic disc size. Invest Ophthalmol Vis Sci. 1992;33:2012\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR5","first-page":"741","volume":"41","author":"LA Kerrigan-Baumrind","year":"2000","unstructured":"Kerrigan-Baumrind LA, Quigley HA, Pease ME, Kerrigan DF, Mitchell RS. Number of ganglion cells in glaucoma eyes compared with threshold visual tests in the same persons. Invest Ophthalmol Vis Sci. 2000;41:741\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR6","doi-asserted-by":"publisher","first-page":"1544","DOI":"10.1001\/archopht.1987.01060110090039","volume":"105","author":"A Heijl","year":"1978","unstructured":"Heijl A, Lindgren G, Olsson J. Normal variability of static perimetric threshold values across the central visual field. Arch Ophthalmol. 1978;105:1544\u20139.","journal-title":"Arch Ophthalmol"},{"key":"1049_CR7","first-page":"2741","volume":"35","author":"BJ Lachenmayr","year":"1994","unstructured":"Lachenmayr BJ, Kojetinsky S, Ostermaier N, Angstwurm K, Vivell PMO, Schaumberger M. The different effects of aging on normal sensitivity in flicker and light-sense perimetry. Invest Ophthalmol Vis Sci. 1994;35:2741\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR8","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1111\/j.1600-0420.2007.01055.x","volume":"86","author":"A Hermann","year":"2008","unstructured":"Hermann A, Paetzold J, Vonthein R, Krapp E, Rauscher S, Schiefer U. Age-dependent normative values for differential luminance sensitivity in automated static perimetry using the Octopus 101. Acta Ophthalmol. 2008;86:446\u201355.","journal-title":"Acta Ophthalmol"},{"key":"1049_CR9","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1097\/00006324-200106000-00017","volume":"78","author":"PGD Spry","year":"2001","unstructured":"Spry PGD, Johnson CA. Changes of the normal visual field: an age-old problem. Optom Vis Sci. 2001;78:436\u201341.","journal-title":"Optom Vis Sci"},{"key":"1049_CR10","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.ajo.2021.04.027","volume":"230","author":"A Iwase","year":"2021","unstructured":"Iwase A, Fujii M, Murata H, Ohno Y, Araie M. Effects of physiologic myopia and aging on visual fields in normal eyes. Am J Ophthalmol. 2021;230:224\u201333.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR11","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1001\/archophthalmol.2010.244","volume":"128","author":"H Hirasawa","year":"2010","unstructured":"Hirasawa H, Tomidokoro A, Araie M, Konno S, Saito H, Iwase A, et al. Peripapillary retinal nerve fiber layer thickness determined by spectral-domain optical coherence tomography in ophthalmologically normal eyes. Arch Ophthalmol. 2010;128:1420\u20136.","journal-title":"Arch Ophthalmol"},{"key":"1049_CR12","doi-asserted-by":"publisher","first-page":"7872","DOI":"10.1167\/iovs.11-7896","volume":"52","author":"JC Mwanza","year":"2011","unstructured":"Mwanza JC, Durbin MK, Budenz DL, Girkin CA, Leung CK, Liebmann JM, Cirrus OCT Normative Database Study Group, et al. Profile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2011;52:7872\u20139.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR13","doi-asserted-by":"publisher","first-page":"8769","DOI":"10.1167\/iovs.11-8388","volume":"52","author":"S Ooto","year":"2011","unstructured":"Ooto S, Hangai M, Tomidokoro A, Saito H, Araie M, Otani T, et al. Effects of age, sex, and axial length on the three-dimensional profile of normal macular layer structures. Invest Ophthalmol Vis Sci. 2011;52:8769\u201379.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR14","doi-asserted-by":"publisher","first-page":"2403","DOI":"10.1016\/j.ophtha.2011.06.013","volume":"118","author":"CA Girkin","year":"2011","unstructured":"Girkin CA, McGwin G Jr, Sinai MJ, Sekhar GC, Fingeret M, Wollstein G, et al. Variation in optic nerve and macular structure with age and race with spectral-domain optical coherence tomography. Ophthalmology. 2011;118:2403\u20138.","journal-title":"Ophthalmology"},{"key":"1049_CR15","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1001\/archopthalmol.2011.1576","volume":"130","author":"OJ Knight","year":"2012","unstructured":"Knight OJ, Girkin CA, Budenz DL, Durbin MK, Feuer WJ, Cirrus OCT Normative Database Study Group. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. Arch Ophthalmol. 2012;130:312\u20138.","journal-title":"Arch Ophthalmol"},{"key":"1049_CR16","doi-asserted-by":"publisher","first-page":"7199","DOI":"10.1167\/iovs.14-14964","volume":"55","author":"M Araie","year":"2014","unstructured":"Araie M, Saito H, Tomidokoro A, Murata H, Iwase A. Relationship between macular inner retinal layer thickness and corresponding retinal sensitivity in normal eyes. Invest Ophthalmol Vis Sci. 2014;55:7199\u2013205.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR17","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/j.ophtha.2011.10.010","volume":"119","author":"CKS Leung","year":"2012","unstructured":"Leung CKS, Yu M, Weinreb RN, Ye C, Liu S, Lai G, et al. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography. A prospective analysis of age-related loss. Ophthalmology. 2012;119:731\u20137.","journal-title":"Ophthalmology"},{"key":"1049_CR18","doi-asserted-by":"publisher","first-page":"2485","DOI":"10.1016\/j.ophtha.2013.07.021","volume":"120","author":"CKS Leung","year":"2013","unstructured":"Leung CKS, Ye C, Weinreb RN, Yu M, Lai G, Lam DS. Impact of age-related change of retinal nerve fiber layer and macular thicknesses on evaluation of glaucoma progression. Ophthalmology. 2013;120:2485\u201392.","journal-title":"Ophthalmology"},{"key":"1049_CR19","doi-asserted-by":"publisher","first-page":"2392","DOI":"10.1016\/j.ophtha.2015.08.020","volume":"122","author":"JR Vianna","year":"2015","unstructured":"Vianna JR, Danthurebandara VM, Sharpe GP, Hutchison DM, Belliveau AC, Shuba LM, et al. Importance of normal aging in estimating the rate of glaucomatous neuroretinal rim and retinal nerve fiber layer loss. Ophthalmology. 2015;122:2392\u20138.","journal-title":"Ophthalmology"},{"key":"1049_CR20","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.ajo.2017.03.008","volume":"178","author":"L Hammel","year":"2017","unstructured":"Hammel L, Belghith A, Weinreb RN, Medeiros FA, Mendoza N, Zangwill LM. Comparing the rates of retinal nerve fiber layer and ganglion-cell-inner plexiform layer loss in healthy eyes and in glaucomatous eyes. Am J Ophthalmol. 2017;178:38\u201350.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR21","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.ajo.2018.08.050","volume":"196","author":"C Bowd","year":"2018","unstructured":"Bowd C, Zangwill LM, Weinreb RB, Girkin CA, Fazio MA, Liebmann JM, et al. Racial differences in rate of change of spectral domain OCT-measured minimum rim width and retinal nerve fiber thickness. Am J Ophthalmol. 2018;196:154\u201364.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR22","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1111\/aos.14553","volume":"99","author":"HM \u00d6hnell","year":"2021","unstructured":"\u00d6hnell HM, Heijl A, Bengtsson B. Ageing and glaucoma progression on the retinal nerve fibre layer using spectral-domain optical coherence tomography analysis. Acta Ophthalmol. 2021;99:260\u20138.","journal-title":"Acta Ophthalmol"},{"key":"1049_CR23","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ajo.2010.03.015","volume":"150","author":"L Pierro","year":"2010","unstructured":"Pierro L, Giatsidis SM, Mantovani E, Gagliardi M. Macular thickness interoperator and intraoperator reproducibility in healthy eyes using 7 optical coherence tomography instruments. Am J Ophthalmol. 2010;150:199\u2013204.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR24","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.ajo.2010.06.041","volume":"151","author":"MT Leite","year":"2011","unstructured":"Leite MT, Rao HL, Weinreb RN, Zangwill LM, Bowd C, Sample PA, et al. Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. Am J Ophthalmol. 2011;151:85\u201392.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR25","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1136\/bjophthalmol-2011-301084","volume":"96","author":"A Kanamori","year":"2012","unstructured":"Kanamori A, Nakamura M, Tomioka M, Kawaka Y, Yamada Y, Negi A. Agreement Among three types of spectral-domain optical coherent tomography instruments in measuring parapapillary retinal nerve fibre layer thickness. Br J Ophthalmol. 2012;96:832\u20137.","journal-title":"Br J Ophthalmol"},{"key":"1049_CR26","doi-asserted-by":"publisher","first-page":"5912","DOI":"10.1167\/iovs.11-8644","volume":"53","author":"L Pierro","year":"2012","unstructured":"Pierro L, Gagliardi M, Iuliano L, Ambrosi A, Bandello F. Retinal nerve fiber layer thickness reproducibility using seven different OCT instruments. Invest Ophthalmol Vis Sci. 2012;53:5912\u201320.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2021.05.016","volume":"231","author":"G Mahmoudinezhad","year":"2021","unstructured":"Mahmoudinezhad G, Mohammadzadeh V, Amini N, Delao K, Zhou B, Hong T, et al. Detection of longitudinal ganglion cell\/inner plexiform layer change: comparison of two spectral-domain optical coherence tomography devices. Am J Ophtalmol. 2021;231:1\u201310.","journal-title":"Am J Ophtalmol."},{"key":"1049_CR28","doi-asserted-by":"publisher","first-page":"2261","DOI":"10.1016\/j.ophtha.2012.06.009","volume":"119","author":"R Lisboa","year":"2012","unstructured":"Lisboa R, Leite MT, Zangwill LM, Tafreshi A, Weinreb RN, Medeiors FA. Diagnosing preperimetric glaucoma with spectral domain optical coherencetomography. Ophthalmology. 2012;119:2261\u20139.","journal-title":"Ophthalmology"},{"key":"1049_CR29","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1016\/j.ophtha.2012.03.044","volume":"119","author":"CK Leung","year":"2012","unstructured":"Leung CK, Yu M, Weinreb RN, Lai G, Xu G, Lam DS. Retinal nerve fiber layer with spectral-domain optical coherence tomography: patterns of retinal nerve fiber layer progression. Ophthalmology. 2012;119:1858\u201366.","journal-title":"Ophthalmology"},{"key":"1049_CR30","doi-asserted-by":"publisher","first-page":"2002","DOI":"10.1016\/j.ophtha.2015.06.015","volume":"122","author":"TM Kuang","year":"2015","unstructured":"Kuang TM, Zhang C, Zangwill LM, Weinreb RN, Medeiros FA. Estimating lead time gained by optical coherence tomography in detecting glaucoma before development of visual field defects. Ophthalmology. 2015;122:2002\u20139.","journal-title":"Ophthalmology"},{"key":"1049_CR31","doi-asserted-by":"publisher","first-page":"2243","DOI":"10.1016\/j.ophtha.2015.07.027","volume":"122","author":"T Liu","year":"2015","unstructured":"Liu T, Tatham AJ, Gracitelli CP, Zangwill LM, Weinreb RN, Medeiros FA. Rates of retinal nerve fiber layer loss in contralateral eyes of glaucoma patients with unilateral progression by conventional methods. Ophthalmology. 2015;122:2243\u201351.","journal-title":"Ophthalmology"},{"key":"1049_CR32","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1167\/iovs.16-21202","volume":"58","author":"A Iwase","year":"2017","unstructured":"Iwase A, Sekine A, Suehiro J, Tanaka K, Kawasaki Y, Kawasaki R, et al. A new method of magnification correction for accurately measuring retinal vessel calibers from fundus photographs. Invest Ophthalmol Vis Sci. 2017;58:1858\u201364.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR33","doi-asserted-by":"publisher","first-page":"21293","DOI":"10.1364\/OE.18.021293","volume":"18","author":"Q Yang","year":"2010","unstructured":"Yang Q, Reisman CA, Wang Z, Fukuma Y, Hangai M, Yoshimura N, et al. Automated layer segmentation of macular OCT images using dual-scale gradient information. Opt Express. 2010;18:21293\u2013307.","journal-title":"Opt Express"},{"key":"1049_CR34","doi-asserted-by":"publisher","first-page":"2901","DOI":"10.1016\/j.visres.2007.01.007","volume":"47","author":"N Drasdo","year":"2007","unstructured":"Drasdo N, Millican CL, Katholi CR, Curcio CA. The length of Henle fibers in the human retina and a model of ganglion receptive field density in the visual field. Vis Res. 2007;47:2901\u201311.","journal-title":"Vis Res"},{"key":"1049_CR35","doi-asserted-by":"publisher","first-page":"5028","DOI":"10.1167\/iovs.13-11971","volume":"54","author":"AP Khawaja","year":"2013","unstructured":"Khawaja AP, Chan MP, Garway-Heath DF, Broadway DC, Luben R, Sherwin JC, et al. Associations with retinal nerve fiber layer measurements in the EPIC-Norfolk Eye Study. Invest Ophthalmol Vis Sci. 2013;54:5028\u201334.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR36","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.ophtha.2019.09.019","volume":"127","author":"D Li","year":"2020","unstructured":"Li D, Rauscher FG, Choi EY, Wang M, Baniasadi N, Wirkner K, et al. Sex-specific differences in circumpapillary retinal nerve fiber layer thickness. Ophthalmology. 2020;127:357\u201368.","journal-title":"Ophthalmology"},{"key":"1049_CR37","doi-asserted-by":"publisher","first-page":"3913","DOI":"10.1167\/iovs.09-4189","volume":"51","author":"WK Song","year":"2010","unstructured":"Song WK, Lee SC, Lee ES, Kim CY, Kim SS. Macular thickness variations with sex, age, and axial length in healthy subjects: a spectral domain-optical coherence tomography study. Invest Ophthalmol Vis Sci. 2010;51:3913\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR38","doi-asserted-by":"publisher","first-page":"7297","DOI":"10.1167\/iovs.14-14993","volume":"55","author":"DJ Russel","year":"2014","unstructured":"Russel DJ, Fallah S, Lier CF, Riffenburgh RH. A comprehensive model for correcting RNFL readings of varying signal strengths in Cirrus optical coherence tomography. Invest Ophthalmol Vis Sci. 2014;55:7297\u2013302.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR39","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1186\/s12886-021-02023-0","volume":"21","author":"X Xu","year":"2021","unstructured":"Xu X, Xiao H, Lai K, Guo X, Luo J, Liu X. Determinants of macular ganglion cell-inner plexiform layer thickness in normal Chinese adults. BMC Ophthalmol. 2021;21:267.","journal-title":"BMC Ophthalmol"},{"key":"1049_CR40","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.preteyeres.2007.08.001","volume":"26","author":"DC Hood","year":"2007","unstructured":"Hood DC, Kardon RH. A framework for comparing structural and functional measures of glaucomatous damage. Prog Retin Eye Res. 2007;26:688\u2013710.","journal-title":"Prog Retin Eye Res"},{"key":"1049_CR41","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.preteyeres.2010.02.001","volume":"29","author":"RS Harwerth","year":"2010","unstructured":"Harwerth RS, Wheat JI, Fredette MJ, Anderson DR. Linking structure and function in glaucoma. Prog Retin Eye Res. 2010;29:249\u201371.","journal-title":"Prog Retin Eye Res"},{"key":"1049_CR42","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/S0161-6420(00)00497-8","volume":"108","author":"T Aung","year":"2001","unstructured":"Aung T, Foster PJ, Seah SK, Chan SP, Lim WK, Wu HM, et al. Automated static perimetry: the influence of myopia and its method of correction. Ophthalmology. 2001;108:290\u20135.","journal-title":"Ophthalmology"},{"key":"1049_CR43","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.ajo.2004.08.076","volume":"139","author":"E Tay","year":"2005","unstructured":"Tay E, Seah SK, Chan SP, Lim AT, Chew SJ, Foster PJ, et al. Optic disk ovality as an index of tilt and its relationship to myopia and perimetry. Am J Ophthalmol. 2005;139:247\u201352.","journal-title":"Am J Ophthalmol"},{"key":"1049_CR44","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10384-012-0181-0","volume":"57","author":"M Araie","year":"2013","unstructured":"Araie M. Test-retest variability in structural parameters measured with glaucoma imaging devices. Jpn J Ophthalmol. 2013;57:1\u201324.","journal-title":"Jpn J Ophthalmol"},{"key":"1049_CR45","doi-asserted-by":"publisher","first-page":"8323","DOI":"10.1167\/iovs.11-7962","volume":"52","author":"JC Mwanza","year":"2011","unstructured":"Mwanza JC, Oakley JD, Budenz DL, Chang RT, Knight OJ, Feuer WJ. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci. 2011;52:8323\u20139.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR46","doi-asserted-by":"publisher","first-page":"4437","DOI":"10.1167\/iovs.08-1753","volume":"49","author":"RS Harwerth","year":"2008","unstructured":"Harwerth RS, Wheat JL, Rangaswamy NV. Age-related loss of retinal ganglion cells and axons. Invest Ophthalmol Vis Sci. 2008;49:4437\u201343.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR47","doi-asserted-by":"publisher","first-page":"5134","DOI":"10.1167\/iovs.14-14303","volume":"55","author":"NB Patel","year":"2014","unstructured":"Patel NB, Lim M, Gajjar A, Evans KB, Harwerth RS. Age-associated changes in the retinal nerve fiber layer and optic nerve head. Invest Ophthalmol Vis Sci. 2014;55:5134\u201343.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR48","doi-asserted-by":"publisher","first-page":"4106","DOI":"10.1167\/iovs.17-22057","volume":"58","author":"M Araie","year":"2017","unstructured":"Araie M, Iwase A, Sugiyama K, Nakazawa T, Tomita G, Hangai M, et al. Determinants and characteristics of Bruch\u2019s membrane opening and Bruch\u2019s membrane opening-minimum rim width in a normal Japanese population. Invest Ophthalmol Vis Sci. 2017;58:4106\u201313.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR49","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1016\/j.ophtha.2012.09.005","volume":"120","author":"PJ Ernest","year":"2013","unstructured":"Ernest PJ, Schouten JS, Beckers HJ, Hendrikse F, Prins MH, Webers CA. An evidence-based review of prognostic factors for glaucomatous visual field progression. Ophthalmology. 2013;120:512\u20139.","journal-title":"Ophthalmology"},{"key":"1049_CR50","doi-asserted-by":"publisher","first-page":"1989","DOI":"10.1016\/j.ophtha.2011.03.012","volume":"118","author":"MW Marcus","year":"2011","unstructured":"Marcus MW, de Vries MM, Junoy Montolio FG, Jansonius NM. Myopia as a risk factor for open-angle glaucoma: a systematic review and meta-analysis. Ophthalmology. 2011;118:1989\u201394.","journal-title":"Ophthalmology"},{"key":"1049_CR51","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.1167\/iovs.15-18131","volume":"57","author":"M Araie","year":"2016","unstructured":"Araie M, Murata H, Iwase A, Hangai M, Sugiyama K, Yoshimura N. Differences in relationship between macular inner retinal layer thickness and retinal sensitivity in eyes with early and progressed glaucoma. Invest Ophthalmol Vis Sci. 2016;57:1588\u201394.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1049_CR52","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1097\/00041327-199906000-00002","volume":"19","author":"AB Safran","year":"1999","unstructured":"Safran AB, Landis T. From cortical plasticity and unawareness of visual field defects. J Neuroophthalmol. 1999;19:84\u20138.","journal-title":"J Neuroophthalmol"}],"container-title":["Japanese Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-024-01049-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10384-024-01049-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-024-01049-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,26]],"date-time":"2024-03-26T06:07:09Z","timestamp":1711433229000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10384-024-01049-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":52,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["1049"],"URL":"https:\/\/doi.org\/10.1007\/s10384-024-01049-3","relation":{},"ISSN":["0021-5155","1613-2246"],"issn-type":[{"value":"0021-5155","type":"print"},{"value":"1613-2246","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"31 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"A. Iwase, Consulting fees (Santen), Payment or honoraria for lectures (ZEISS, Crewt Medical Systems, Heidelberg Engineering, Santen, Senju, Otsuka, Novartis), Patents planned, issued or pending (Topcon without any royalties) ; T. Higashide, Payment or honoraria for lectures (Santen, Senju, Novartis, Bayer, Kowa, Otsuka, Nitto, Viatris), Payment or honoraria for educational events (HOYA); M. Araie, Consulting fees (Aerie, Santen, Senju, Kowa), Payment or honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events (Santen), Patents planned, issued or pending (Topcon without any royalties), Participation on a Data Safety Monitoring Board or Advisory Board (Topcon); M. Fujii, None; Y. Ohno, None; Y. Tanaka, Employee (Santen); T. Kikawa, Employee (Topcon).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of Interest"}}]}}