{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T06:38:43Z","timestamp":1776494323654,"version":"3.51.2"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:00:00Z","timestamp":1759104000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:00:00Z","timestamp":1759104000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Ophthalmol"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the clinical performance of a hydrophobic acrylic toric intraocular lens (IOL) with double C-loop haptics in a Japanese population with cataracts.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Prospective<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The PODEYE TORIC IOL (POD T 49P) was implanted in 58 eyes from 42 patients diagnosed with bilateral cataracts with corneal astigmatism. Thirty-one eyes received IOLs with cylinder powers of 1.50 to 6.00 D (group A), and 27 eyes received IOLs with 1.00 D cylinder (group B). Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and refractive cylinder were examined postoperatively. The primary endpoints, which were the non-inferiority of UDVA in group A and superiority of the refractive cylinder in group B, were examined and compared with relevant previous data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In group A, the mean preoperative corneal astigmatism was 1.87\u00b11.01 D and postoperative logMAR UDVA and CDVA were -0.023\u00b10.110 and -0.102\u00b10.079, respectively. There were 23 eyes (74.2%) with UDVA of 0.0 logMAR or better, while the refractive cylinder was - 0.39\u00b10.39 D. In group B, the preoperative corneal astigmatism of 0.73\u00b10.22 D and postoperative logMAR UDVA and CDVA were -0.074\u00b10.091 and -0.096\u00b10.075, respectively; 23 eyes (85.2%) obtained a UDVA of 0.0 logMAR or better. The postoperative refractive cylinder was -0.16\u00b10.23D. The non-inferiority of UDVA in group A and the superiority of the refractive cylinder in group B were verified with previous data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The PODEYE TORIC IOL with 1.00\u20136.00 D cylinder powers and double C-loop haptics effectively corrected corneal astigmatism in Japanese patients after cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration number<\/jats:title>\n                    <jats:p>NCT04699266 (Clinicaltrials.gov)<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10384-025-01274-4","type":"journal-article","created":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T06:11:48Z","timestamp":1759126308000},"page":"278-285","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical performance of a hydrophobic acrylic toric intraocular lens with a double C-loop haptics in Japanese patients"],"prefix":"10.1007","volume":"70","clinical-trial-number":[{"clinical-trial-number":"nct04699266","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0053-5078","authenticated-orcid":false,"given":"Yosai","family":"Mori","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazunori","family":"Miyata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuo","family":"Ichikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshifumi","family":"Fujita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuya","family":"Shiba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroko","family":"Bissen-Miyajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,29]]},"reference":[{"key":"1274_CR1","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1136\/bjophthalmol-2018-312025","volume":"103","author":"AC Day","year":"2019","unstructured":"Day AC, Dhariwal M, Keith MS, Ender F, Perez Vives C, Miglio C, et al. Distribution of preoperative and postoperative astigmatism in a large population of patients undergoing cataract surgery in the UK. Br J Ophthalmol. 2019;103:993\u20131000.","journal-title":"Br J Ophthalmol"},{"key":"1274_CR2","first-page":"447","volume":"115","author":"T Miyake","year":"2011","unstructured":"Miyake T, Kamiya K, Amano R, Shimizu K. Corneal astigmatism before cataract surgery. Nippon Ganka Gakkai Zasshi. 2011;115:447\u201353.","journal-title":"Nippon Ganka Gakkai Zasshi"},{"key":"1274_CR3","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J. Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology. 2016;123:275\u201386.","journal-title":"Ophthalmology"},{"key":"1274_CR4","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jcrs.2013.09.010","volume":"40","author":"EA Villegas","year":"2014","unstructured":"Villegas EA, Alcon E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg. 2014;40:13\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR5","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1016\/j.jcrs.2016.07.034","volume":"42","author":"Y Ninomiya","year":"2016","unstructured":"Ninomiya Y, Minami K, Miyata K, Eguchi S, Sato R, Okamoto F, et al. Toric intraocular lenses in eyes with with-the-rule, against-the-rule, and oblique astigmatism: one-year results. J Cataract Refract Surg. 2016;42:1431\u201340.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR6","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1016\/j.jcrs.2013.06.027","volume":"39","author":"DD Koch","year":"2013","unstructured":"Koch DD, Jenkins RB, Weikert MP, Yeu E, Wang L. Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism. J Cataract Refract Surg. 2013;39:1803\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR7","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.jcrs.2010.11.026","volume":"37","author":"P Ernest","year":"2011","unstructured":"Ernest P, Potvin R. Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens. J Cataract Refract Surg. 2011;37:727\u201332.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR8","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1007\/s10792-022-02571-4","volume":"43","author":"C Bellucci","year":"2023","unstructured":"Bellucci C, Panico A, Tedesco SA, Carta A, Gandolfi S, Bellucci R, et al. One-dioptre toric IOL versus spherical IOL in eyes with low preoperative corneal astigmatism. Int Ophthalmol. 2023;43:1711\u20139.","journal-title":"Int Ophthalmol"},{"key":"1274_CR9","doi-asserted-by":"publisher","first-page":"755","DOI":"10.2147\/OPTH.S448427","volume":"18","author":"H Bissen-Miyajima","year":"2024","unstructured":"Bissen-Miyajima H, Ota Y, Yaguchi S, Nakamura K, Sasaki N. Clinical results of a trifocal toric intraocular lens using the holladay total surgically induced astigmatism formula for correcting low corneal astigmatism in Japanese patients. Clin Ophthalmol. 2024;18:755\u201363.","journal-title":"Clin Ophthalmol"},{"key":"1274_CR10","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.survophthal.2014.04.004","volume":"59","author":"JL Alio","year":"2014","unstructured":"Alio JL, Grzybowski A, El Aswad A, Romaniuk D. Refractive lens exchange. Surv Ophthalmol. 2014;59:579\u201398.","journal-title":"Surv Ophthalmol"},{"key":"1274_CR11","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1016\/j.jfo.2022.07.005","volume":"46","author":"C Chassain","year":"2023","unstructured":"Chassain C, Hallak MK, Lesaffre M. Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design. J Fr Ophtalmol. 2023;46:571\u201380.","journal-title":"J Fr Ophtalmol"},{"key":"1274_CR12","doi-asserted-by":"publisher","first-page":"2765","DOI":"10.2147\/OPTH.S432598","volume":"17","author":"RET Ang","year":"2023","unstructured":"Ang RET, Ta\u00f1\u00e1-Rivero P, Pastor-Pascual F, Stodulka P, Tetz M, Fischinger I. Visual and refractive outcomes after bilateral implantation of a biconvex aspheric toric monofocal intraocular with a double C-loop haptic design. Clin Ophthalmol. 2023;17:2765\u201376.","journal-title":"Clin Ophthalmol"},{"key":"1274_CR13","unstructured":"Application form for marketing authorization for Alcon AcrySof Toric Single-peace (Alcon Japan Ltd., Approval number: 22000BZX01199000)."},{"key":"1274_CR14","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.jcrs.2016.02.038","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Koch DD, Wang L, Hill WE, Assia EI, Franchina M, et al. New regression formula for toric intraocular lens calculations. J Cataract Refract Surg. 2016;42:663\u201371.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR15","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1097\/j.jcrs.0000000000001486","volume":"50","author":"ES Li","year":"2024","unstructured":"Li ES, Vanderford EK, Xu Y, Kang PC. Rotational stability of toric intraocular lenses by lens model and haptic design: systematic review and single-arm meta-analysis. J Cataract Refract Surg. 2024;50:976\u201384.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR16","unstructured":"ISO 11979-7:2018 ophthalmic implants \u2014 intraocular lenses \u2014 part 7: clinical investigations; 2018 [Available: https:\/\/www.iso.org\/standard\/69038.html]."},{"key":"1274_CR17","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1097\/j.jcrs.0000000000000079","volume":"46","author":"G N\u00e9meth","year":"2020","unstructured":"N\u00e9meth G. One degree of misalignment does not lead to a 3.3% effect decrease after implantation of a toric intraocular lens. J Cataract Refract Surg. 2020;46:482.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR18","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.jcrs.2017.10.053","volume":"44","author":"D Tognetto","year":"2018","unstructured":"Tognetto D, Perrotta AA, Bauci F, Rinaldi S, Antonuccio M, Pellegrino FA, et al. Quality of images with toric intraocular lenses. J Cataract Refract Surg. 2018;44:376\u201381.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR19","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1007\/s00417-023-06232-9","volume":"262","author":"J Sun","year":"2024","unstructured":"Sun J, Bai H, Cui W, Wu X. Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial. Graefes Arch Clin Exp Ophthalmol. 2024;262:847\u201355.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1274_CR20","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1097\/j.jcrs.0000000000000415","volume":"47","author":"A Haripriya","year":"2021","unstructured":"Haripriya A, Gk S, Mani I, Chang DF. Comparison of surgical repositioning rates and outcomes for hydrophilic vs hydrophobic single-piece acrylic toric IOLs. J Cataract Refract Surg. 2021;47:178\u201383.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR21","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1016\/j.jcrs.2013.11.039","volume":"40","author":"S Maedel","year":"2014","unstructured":"Maedel S, Hirnschall N, Chen YA, Findl O. Rotational performance and corneal astigmatism correction during cataract surgery: aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal incision. J Cataract Refract Surg. 2014;40:1355\u201362.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR22","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1016\/S0886-3350(99)00204-7","volume":"25","author":"C Vass","year":"1999","unstructured":"Vass C, Menapace R, Schmetterer K, Findl O, Rainer G, Steineck I. Prediction of pseudophakic capsular bag diameter based on biometric variables. J Cataract Refract Surg. 1999;25:1376\u201381.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR23","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1016\/j.jcrs.2011.04.035","volume":"37","author":"M Modesti","year":"2011","unstructured":"Modesti M, Pasqualitto G, Appolloni R, Pecorella I, Sourdille P. Preoperative and postoperative size and movements of the lens capsular bag: ultrasound biomicroscopy analysis. J Cataract Refract Surg. 2011;37:1775\u201384.","journal-title":"J Cataract Refract Surg"},{"key":"1274_CR24","doi-asserted-by":"publisher","first-page":"9437","DOI":"10.1038\/s41598-023-36694-0","volume":"13","author":"I Cabeza-Gil","year":"2023","unstructured":"Cabeza-Gil I, Frechilla J, Calvo B. Evaluation of the mechanical stability of intraocular lenses using digital image correlation. Sci Rep. 2023;13:9437.","journal-title":"Sci Rep"},{"key":"1274_CR25","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.jcrs.2018.09.028","volume":"45","author":"JT Holladay","year":"2019","unstructured":"Holladay JT, Pettit G. Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5 mm temporal incision. J Cataract Refract Surg. 2019;45:272\u201383.","journal-title":"J Cataract Refract Surg."},{"key":"1274_CR26","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.18240\/ijo.2020.10.09","volume":"13","author":"P Orts-Vila","year":"2020","unstructured":"Orts-Vila P, Aguilar-C\u00f3rcoles S, Tello-Elordi C, Ramos-Alzamora M, Mont\u00e9s-Mic\u00f3 R, Ta\u00f1\u00e1-Rivero P. Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism. Int J Ophthalmol. 2020;13:1567\u201373.","journal-title":"Int J Ophthalmol"}],"container-title":["Japanese Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-025-01274-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10384-025-01274-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-025-01274-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T05:40:16Z","timestamp":1776490816000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10384-025-01274-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,29]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["1274"],"URL":"https:\/\/doi.org\/10.1007\/s10384-025-01274-4","relation":{},"ISSN":["0021-5155","1613-2246"],"issn-type":[{"value":"0021-5155","type":"print"},{"value":"1613-2246","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,29]]},"assertion":[{"value":"6 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Y. Mori, Payment or honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events (Alcon, HOYA, BVI, KOWA, NIDEK, Santen, AMO); K. Miyata, Grants or contracts to the author\u2019s institution (Alcon, BVI, HOYA, NIDEK, AMO), Payment or honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events (Alcon, AMO, BVI, KOWA, HOYA, Santen, ZEISS), Patents planned, issued or pending (TOMEY); T. Kojima, None; K. Ichikawa, Grants or contracts to the author\u2019s institution (Alcon), Stock or stock options (Alcon), Receipt of equipment, materials, drugs, medical writing, gifts or other services to the author\u2019s institution (Alcon); Y. Fujita, None; T. Shiba, None; H. B-Miyajima, Consulting fees (BVI), Payment or honoraria for lectures, presentations, speakers bureaus, manuscript writing or educational events (BVI).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}