{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T18:14:49Z","timestamp":1791224089525,"version":"4.1.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["U20A20196"],"award-info":[{"award-number":["U20A20196"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Ophthalmol"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To explore the positional relationship between intraocular lens (IOL) and crystalline lens (CLL) by anterior segment optical coherence tomography (AS-OCT) in high myopia complicated with cataract eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Retrospective and consecutive study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Patients who had undergone phacoemulsification with IOL implantation were reviewed. Exclusion criteria were any ocular history that could have affected the zonules, poor pupil dilation and intra- or post- operative complications. The magnitude and direction of tilt and decentration of CLL and IOL, CLL thickness (LT), anterior chamber depth (ACD) and axial length (AL) were measured.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Fifty eyes without high myopia (EM group) and 73 high myopia eyes (HM group) were recruited. The magnitude of tilt and decentration of CLL was significantly different between the HM and EM group (p\n                      <jats:sub>tilt HM vs. EM<\/jats:sub>\n                      &lt;0.01, p\n                      <jats:sub>decentration HM vs. EM<\/jats:sub>\n                      &lt;0.01). In terms of the decentration, the magnitude of IOL was significantly higher than of CLL in both the HM and EM groups (p\n                      <jats:sub>HM<\/jats:sub>\n                      &lt; 0.01; p\n                      <jats:sub>EM<\/jats:sub>\n                      =0.043). Multivariate analysis showed that only the alignment of CLL was related with the position of IOL in both group (R\n                      <jats:sup>2<\/jats:sup>\n                      <jats:sub>tilt EM<\/jats:sub>\n                      =0.237, p\n                      <jats:sub>tilt EM<\/jats:sub>\n                      &lt; 0.01, R\n                      <jats:sup>2<\/jats:sup>\n                      <jats:sub>decentration EM<\/jats:sub>\n                      =0.097, p\n                      <jats:sub>tilt EM<\/jats:sub>\n                      =0.042; R\n                      <jats:sup>2<\/jats:sup>\n                      <jats:sub>tilt HM<\/jats:sub>\n                      =0.476, p\n                      <jats:sub>tilt HM<\/jats:sub>\n                      &lt; 0.01, R\n                      <jats:sup>2<\/jats:sup>\n                      <jats:sub>decentration HM<\/jats:sub>\n                      =0.359, p\n                      <jats:sub>tilt HM<\/jats:sub>\n                      &lt; 0.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Alignment of CLL in high myopia eyes determines the position of the IOL. Moreover, the IOL in high myopia was more decentrated, while this discrepancy did not reach a level that would compromise visual quality, it needs to be taken into consideration.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10384-026-01327-2","type":"journal-article","created":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T07:03:35Z","timestamp":1772175815000},"page":"546-551","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The intraocular lens position in high myopia eyes"],"prefix":"10.1007","volume":"70","author":[{"given":"Ziyi","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siqing","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Xin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhe","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"key":"1327_CR1","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.1007\/s00417-018-4132-4","volume":"256","author":"M Burgm\u00fcller","year":"2018","unstructured":"Burgm\u00fcller M, Mihaltz K, Sch\u00fctze C, Angermann B, V\u00e9csei-Marlovits V. Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery. Graefes Arch Clin Exp Ophthalmol. 2018;256:2361\u20137.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1327_CR2","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.jcrs.2018.10.045","volume":"45","author":"X Liu","year":"2019","unstructured":"Liu X, Xie L, Huang Y. Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens. J Cataract Refract Surg. 2019;45:507\u201314.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR3","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1136\/bjo.2006.099945","volume":"91","author":"T Oshika","year":"2007","unstructured":"Oshika T, Sugita G, Miyata K, Tokunaga T, Samejima T, Okamoto C, et al. Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol. 2007;91:185\u20138.","journal-title":"Br J Ophthalmol"},{"key":"1327_CR4","doi-asserted-by":"publisher","first-page":"2274","DOI":"10.1016\/j.jcrs.2015.10.059","volume":"41","author":"MJ Kim","year":"2015","unstructured":"Kim MJ, Yoo YS, Joo CK, Yoon G. Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: influence of pupil size, decentration, and rotation. J Cataract Refract Surg. 2015;41:2274\u201382.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR5","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jcrs.2009.01.023","volume":"35","author":"M Baumeister","year":"2009","unstructured":"Baumeister M, B\u00fchren J, Kohnen T. Tilt and decentration of spherical and aspheric intraocular lenses: effect on higher-order aberrations. J Cataract Refract Surg. 2009;35:1006\u201312.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR6","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.jcrs.2008.09.028","volume":"35","author":"U Mester","year":"2009","unstructured":"Mester U, Sauer T, Kaymak H. Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes. J Cataract Refract Surg. 2009;35:485\u201390.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR7","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1097\/j.jcrs.0000000000000632","volume":"47","author":"Z Li","year":"2021","unstructured":"Li Z, Zhu Z, Li X, Meng Z, Qu W, Zhao Y. Age-related changes in crystalline lens tilt and decentration: swept-source OCT study. J Cataract Refract Surg. 2021;47:1290\u20135.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR8","doi-asserted-by":"publisher","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","volume":"18","author":"JT Holladay","year":"2002","unstructured":"Holladay JT, Piers PA, Koranyi G, van der Mooren M, Norrby NE. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg. 2002;18:683\u201391.","journal-title":"J Refract Surg"},{"key":"1327_CR9","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","volume":"45","author":"T Lawu","year":"2019","unstructured":"Lawu T, Mukai K, Matsushima H, Senoo T. Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye. J Cataract Refract Surg. 2019;45:662\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR10","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.1016\/j.ophtha.2011.02.025","volume":"118","author":"J McKelvie","year":"2011","unstructured":"McKelvie J, McArdle B, McGhee C. The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses. Ophthalmology. 2011;118:1724\u201331.","journal-title":"Ophthalmology"},{"key":"1327_CR11","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.ajo.2022.05.005","volume":"242","author":"J Xu","year":"2022","unstructured":"Xu J, Lin P, Zhang S, Lu Y, Zheng T. Risk factors associated with intraocular lens decentration after cataract surgery. Am J Ophthalmol. 2022;242:88\u201395.","journal-title":"Am J Ophthalmol"},{"key":"1327_CR12","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.63.1.8","volume":"63","author":"SM Li","year":"2022","unstructured":"Li SM, Wei S, Atchison DA, Kang MT, Liu L, Li H, et al. Annual incidences and progressions of myopia and high myopia in Chinese schoolchildren based on a 5-year cohort study. Invest Ophthalmol Vis Sci. 2022;63:8.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1327_CR13","doi-asserted-by":"publisher","first-page":"420","DOI":"10.18240\/ijo.2022.03.08","volume":"15","author":"JL Patnaik","year":"2022","unstructured":"Patnaik JL, Kahook MY, Berdahl JP, Hardten DR, Wagner BD, Seibold LK, et al. Association between axial length and toric intraocular lens rotation according to an online toric back-calculator. Int J Ophthalmol. 2022;15:420\u20135.","journal-title":"Int J Ophthalmol"},{"key":"1327_CR14","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","volume":"100","author":"X Zhu","year":"2016","unstructured":"Zhu X, He W, Zhang K, Lu Y. Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses. Br J Ophthalmol. 2016;100:263\u20138.","journal-title":"Br J Ophthalmol"},{"key":"1327_CR15","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0184066","volume":"12","author":"S Kimura","year":"2017","unstructured":"Kimura S, Morizane Y, Shiode Y, Hirano M, Doi S, Toshima S, et al. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS ONE. 2017;12:e0184066.","journal-title":"PLoS ONE"},{"key":"1327_CR16","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1016\/j.jcrs.2017.01.026","volume":"43","author":"N Hirnschall","year":"2017","unstructured":"Hirnschall N, Buehren T, Bajramovic F, Trost M, Teuber T, Findl O. Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography. J Cataract Refract Surg. 2017;43:732\u20136.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR17","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.jcrs.2018.08.025","volume":"45","author":"L Wang","year":"2019","unstructured":"Wang L, de Guimaraes Souza R, Weikert MP, Koch DD. Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer. J Cataract Refract Surg. 2019;45:35\u201340.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR18","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ajo.2021.08.017","volume":"235","author":"L Wang","year":"2022","unstructured":"Wang L, Jin G, Zhang J, Chen X, Tan X, Wang W, et al. Clinically Significant Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Swept-Source Optical Coherence Tomography Study. Am J Ophthalmol. 2022;235:46\u201355.","journal-title":"Am J Ophthalmol"},{"key":"1327_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-020-00186-3","volume":"7","author":"J Meng","year":"2020","unstructured":"Meng J, He W, Rong X, Miao A, Lu Y, Zhu X. Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes. Eye and Vision. 2020;7:17.","journal-title":"Eye and Vision"},{"key":"1327_CR20","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1007\/s10792-021-02106-3","volume":"42","author":"T Tokuhisa","year":"2022","unstructured":"Tokuhisa T, Watanabe T, Watanabe A, Nakano T. Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation. Int Ophthalmol. 2022;42:1213\u201320.","journal-title":"Int Ophthalmol"},{"key":"1327_CR21","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/j.jcrs.0000000000001115","volume":"49","author":"X Gu","year":"2023","unstructured":"Gu X, Zhang M, Liu Z, Ruan X, Tan X, Zhang E, et al. Building prediction models of clinically significant intraocular lens tilt and decentration for age-related cataract. J Cataract Refract Surg. 2023;49:385\u201391.","journal-title":"J Cataract Refract Surg"},{"key":"1327_CR22","doi-asserted-by":"publisher","DOI":"10.21037\/atm-20-1008","volume":"8","author":"X Gu","year":"2020","unstructured":"Gu X, Chen X, Yang G, Wang W, Xiao W, Jin G, et al. Determinants of intraocular lens tilt and decentration after cataract surgery. Ann Transl Med. 2020;8:921.","journal-title":"Ann Transl Med"}],"container-title":["Japanese Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-026-01327-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10384-026-01327-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-026-01327-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T09:54:55Z","timestamp":1780307695000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10384-026-01327-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,27]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["1327"],"URL":"https:\/\/doi.org\/10.1007\/s10384-026-01327-2","relation":{},"ISSN":["0021-5155","1613-2246"],"issn-type":[{"value":"0021-5155","type":"print"},{"value":"1613-2246","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,27]]},"assertion":[{"value":"11 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Z. Wang, None; S. He, None; N. Ding, None; C. Xin, None; Z. Dong, None.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}