{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T05:44:16Z","timestamp":1786167856347,"version":"build-2736575974"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T00:00:00Z","timestamp":1774915200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T00:00:00Z","timestamp":1774915200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"crossref","award":["RS-2023-00253065"],"award-info":[{"award-number":["RS-2023-00253065"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Ophthalmol"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1007\/s10384-026-01346-z","type":"journal-article","created":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T09:23:35Z","timestamp":1774949015000},"page":"886-896","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Longitudinal changes in retinal nerve fiber layer thickness after vitrectomy for vitreomacular traction syndrome"],"prefix":"10.1007","volume":"70","author":[{"given":"Gee-Hyun","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young-Geun","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9553-3069","authenticated-orcid":false,"given":"Young-Hoon","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,31]]},"reference":[{"key":"1346_CR1","doi-asserted-by":"publisher","first-page":"2611","DOI":"10.1016\/j.ophtha.2013.07.042","volume":"120","author":"JS Duker","year":"2013","unstructured":"Duker JS, Kaiser PK, Binder S, de Smet MD, Gaudric A, Reichel E, et al. The International Vitreomacular Traction Study Group classification of vitreomacular adhesion, traction, and macular hole. Ophthalmology. 2013;120:2611\u20139.","journal-title":"Ophthalmology"},{"key":"1346_CR2","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1007\/s00417-019-04352-9","volume":"257","author":"EK Lee","year":"2019","unstructured":"Lee EK, Lee SY, Lee JY, Heo JW, Yu HG, Chung H. Anatomical configurations of vitreomacular traction syndrome: influence on clinical course and surgical outcomes. Graefes Arch Clin Exp Ophthalmol. 2019;257:1631\u20139.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1346_CR3","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1177\/24741264211045867","volume":"6","author":"ZA Nawrocka","year":"2022","unstructured":"Nawrocka ZA, Nawrocka Z, Nawrocki J. Swept-source optical coherence tomography angiography in vitreomacular traction syndrome. J Vitreoretin Dis. 2022;6:31\u20139.","journal-title":"J Vitreoretin Dis"},{"issue":"Suppl 1","key":"1346_CR4","doi-asserted-by":"publisher","first-page":"S5","DOI":"10.1097\/IAE.0000000000001906","volume":"38","author":"A Diaz-Valverde","year":"2018","unstructured":"Diaz-Valverde A, Wu L. To peel or not to peel the internal limiting membrane in idiopathic epiretinal membranes. Retina. 2018;38(Suppl 1):S5\u201311.","journal-title":"Retina"},{"key":"1346_CR5","doi-asserted-by":"publisher","first-page":"2305","DOI":"10.1016\/j.ophtha.2009.05.025","volume":"116","author":"O Tan","year":"2009","unstructured":"Tan O, Chopra V, Lu AT, Schuman JS, Ishikawa H, Wollstein G, et al. Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography. Ophthalmology. 2009;116:2305-14.e1-2.","journal-title":"Ophthalmology"},{"key":"1346_CR6","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1038\/nrn1497","volume":"5","author":"H Wassle","year":"2004","unstructured":"Wassle H. Parallel processing in the mammalian retina. Nat Rev Neurosci. 2004;5:747\u201357.","journal-title":"Nat Rev Neurosci"},{"key":"1346_CR7","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1136\/bjo.2009.157875","volume":"93","author":"JS Kim","year":"2009","unstructured":"Kim JS, Ishikawa H, Sung KR, Xu J, Wollstein G, Bilonick RA, et al. Retinal nerve fibre layer thickness measurement reproducibility improved with spectral domain optical coherence tomography. Br J Ophthalmol. 2009;93:1057\u201363.","journal-title":"Br J Ophthalmol"},{"key":"1346_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-43230-7","volume":"13","author":"H Hou","year":"2023","unstructured":"Hou H, El-Nimri NW, Durbin MK, Arias JD, Moghimi S, Weinreb RN. Agreement and precision of wide and cube scan measurements between swept-source and spectral-domain OCT in normal and glaucoma eyes. Sci Rep. 2023;13:15876.","journal-title":"Sci Rep"},{"key":"1346_CR9","volume":"13","author":"KW Bae","year":"2023","unstructured":"Bae KW, Kim DI, Hwang DD. Long-term changes in retinal nerve fiber layer thickness after vitrectomy for epiretinal membrane using optical coherence tomography images. Life (Basel). 2023;13:1804.","journal-title":"Life (Basel)"},{"key":"1346_CR10","volume":"2016","author":"K Ohta","year":"2016","unstructured":"Ohta K, Sato A, Senda N, Fukui E. Transient increase of retinal nerve fiber layer thickness after vitrectomy with ILM peeling for idiopathic macular hole. J Ophthalmol. 2016;2016:5903452.","journal-title":"J Ophthalmol"},{"key":"1346_CR11","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1097\/IAE.0b013e3182a15f8b","volume":"34","author":"VJ John","year":"2014","unstructured":"John VJ, Flynn HW Jr, Smiddy WE, Carver A, Leonard R, Tabandeh H, et al. Clinical course of vitreomacular adhesion managed by initial observation. Retina. 2014;34:442\u20136.","journal-title":"Retina"},{"key":"1346_CR12","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/9457670","volume":"2020","author":"P Petrou","year":"2020","unstructured":"Petrou P, Chalkiadaki E, Errera MH, Liyanage S, Wickham L, Papakonstantinou E, et al. Factors associated with the clinical course of vitreomacular traction. J Ophthalmol. 2020;2020:9457670. https:\/\/doi.org\/10.1155\/2020\/9457670.","journal-title":"J Ophthalmol"},{"key":"1346_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10112240","volume":"10","author":"KY Nam","year":"2021","unstructured":"Nam KY, Kim BJ, Lee WH, Han YS. Repeatability of spectral domain optical coherence tomography measurements of Bruch\u2019s membrane opening-minimum rim width in epiretinal membrane patients with peripapillary involvement. J Clin Med. 2021;10:2240.","journal-title":"J Clin Med"},{"key":"1346_CR14","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1136\/bjophthalmol-2015-307313","volume":"100","author":"YH Lee","year":"2016","unstructured":"Lee YH, Bae HW, Seo SJ, Lee SY, Beon SH, Kang S, et al. Influence of epiretinal membrane on the measurement of peripapillary retinal nerve fibre layer thickness using spectral-domain coherence tomography. Br J Ophthalmol. 2016;100:1035\u201340.","journal-title":"Br J Ophthalmol"},{"key":"1346_CR15","doi-asserted-by":"publisher","first-page":"1983","DOI":"10.1016\/j.ophtha.2014.04.008","volume":"121","author":"M Lalezary","year":"2014","unstructured":"Lalezary M, Shah RJ, Reddy RK, Kammer JA, Kuchtey RW, Joos KM, et al. Prospective retinal and optic nerve vitrectomy evaluation (PROVE) study: twelve-month findings. Ophthalmology. 2014;121:1983\u20139.","journal-title":"Ophthalmology"},{"key":"1346_CR16","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/IAE.0000000000001509","volume":"38","author":"HB Lim","year":"2018","unstructured":"Lim HB, Lee MW, Kwak BS, Jo YJ, Kim JY. Longitudinal changes in thicknesses of the macula, ganglion cell-inner plexiform layer, and retinal nerve fiber layer after vitrectomy: a 12-month observational study. Retina. 2018;38:155\u201362.","journal-title":"Retina"},{"key":"1346_CR17","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1001\/archophthalmol.2010.99","volume":"128","author":"P Batta","year":"2010","unstructured":"Batta P, Engel HM, Shrivastava A, Freeman K, Mian U. Effect of partial posterior vitreous detachment on retinal nerve fiber layer thickness as measured by optical coherence tomography. Arch Ophthalmol. 2010;128:692\u20137.","journal-title":"Arch Ophthalmol"},{"key":"1346_CR18","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1016\/j.ajo.2013.06.016","volume":"156","author":"Y Sugiura","year":"2013","unstructured":"Sugiura Y, Okamoto F, Okamoto Y, Hiraoka T, Oshika T. Intraocular pressure fluctuation during microincision vitrectomy with Constellation Vision System. Am J Ophthalmol. 2013;156:941-7.e1.","journal-title":"Am J Ophthalmol"},{"key":"1346_CR19","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1097\/IAE.0000000000001768","volume":"38","author":"A Scupola","year":"2018","unstructured":"Scupola A, Grimaldi G, Abed E, Sammarco MG, Giudiceandrea A, Greco A, et al. Arcuate nerve fiber layer changes after internal limiting membrane peeling in idiopathic epiretinal membrane. Retina. 2018;38:1777\u201385.","journal-title":"Retina"},{"key":"1346_CR20","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.preteyeres.2016.12.002","volume":"57","author":"DC Hood","year":"2017","unstructured":"Hood DC. Improving our understanding, and detection, of glaucomatous damage: an approach based upon optical coherence tomography (OCT). Prog Retin Eye Res. 2017;57:46\u201375.","journal-title":"Prog Retin Eye Res"}],"container-title":["Japanese Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-026-01346-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10384-026-01346-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10384-026-01346-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T05:23:11Z","timestamp":1786166591000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10384-026-01346-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,31]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["1346"],"URL":"https:\/\/doi.org\/10.1007\/s10384-026-01346-z","relation":{},"ISSN":["0021-5155","1613-2246"],"issn-type":[{"value":"0021-5155","type":"print"},{"value":"1613-2246","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,31]]},"assertion":[{"value":"15 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"G. H. Kim, None; Y. G. Park, None; Y. H. Park, None.","order":1,"name":"Ethics","label":"Conflicts of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors did not use generative AI or AI-assisted technologies in the preparation of this manuscript.","order":2,"name":"Ethics","label":"Disclosure of artificial intelligence (AI) in scientific writing","group":{"name":"EthicsHeading","label":"Declarations"}}]}}