{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T15:00:06Z","timestamp":1785596406737,"version":"3.56.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2018,4,27]],"date-time":"2018-04-27T00:00:00Z","timestamp":1524787200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Ultrasonics"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1007\/s10396-018-0882-1","type":"journal-article","created":{"date-parts":[[2018,4,27]],"date-time":"2018-04-27T08:09:30Z","timestamp":1524816570000},"page":"647-651","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius"],"prefix":"10.1007","volume":"45","author":[{"given":"Takuya","family":"Uemura","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tadashi","family":"Okano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ema","family":"Onode","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Yokoi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kosuke","family":"Shintani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuhiro","family":"Okada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,4,27]]},"reference":[{"key":"882_CR1","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/01.blo.0000205891.96575.0f","volume":"445","author":"JL Orbay","year":"2006","unstructured":"Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res. 2006;445:58\u201367.","journal-title":"Clin Orthop Relat Res"},{"key":"882_CR2","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1177\/1558944715620792","volume":"11","author":"NA Monaco","year":"2016","unstructured":"Monaco NA, Dwyer CL, Ferikes AJ, et al. Hand surgeon reporting of tendon rupture following distal radius volar plating. Hand (N Y). 2016;11:278\u201386.","journal-title":"Hand (N Y)"},{"key":"882_CR3","doi-asserted-by":"publisher","first-page":"159","DOI":"10.5435\/00124635-200505000-00003","volume":"13","author":"AD Nana","year":"2005","unstructured":"Nana AD, Joshi A, Lichtman DM. Plating of the distal radius. J Am Acad Orthop Surg. 2005;13:159\u201371.","journal-title":"J Am Acad Orthop Surg"},{"key":"882_CR4","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/0363-5023(90)90143-F","volume":"15","author":"DJ Pogue","year":"1990","unstructured":"Pogue DJ, Viegas SF, Patterson RM, et al. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am. 1990;15:721\u20137.","journal-title":"J Hand Surg Am"},{"key":"882_CR5","doi-asserted-by":"publisher","first-page":"e893","DOI":"10.3928\/01477447-20160517-05","volume":"39","author":"H Satake","year":"2016","unstructured":"Satake H, Hanaka N, Honma R, et al. Complications of distal radius fractures treated by volar locking plate fixation. Orthopedics. 2016;39:e893\u20136.","journal-title":"Orthopedics"},{"key":"882_CR6","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1177\/1753193408100964","volume":"34","author":"JA Casaletto","year":"2009","unstructured":"Casaletto JA, Machin D, Leung R, et al. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34:471\u20134.","journal-title":"J Hand Surg Eur"},{"key":"882_CR7","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10195-013-0245-z","volume":"14","author":"S Asadollahi","year":"2013","unstructured":"Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14:227\u201334.","journal-title":"J Orthop Traumatol"},{"key":"882_CR8","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.jos.2017.01.025","volume":"22","author":"Y Tanaka","year":"2017","unstructured":"Tanaka Y, Gotani H, Yano K, et al. Evaluation of flexor pollicis longus tendon attrition using color Doppler imaging after volar plate fixation for distal radius fracture. J Orthop Sci. 2017;22:447\u201352.","journal-title":"J Orthop Sci"},{"key":"882_CR9","doi-asserted-by":"publisher","first-page":"e104","DOI":"10.3928\/01477447-20161017-01","volume":"40","author":"C Kadoma","year":"2017","unstructured":"Kadoma C, Takahara M, Maruyama M, et al. Ultrasonographic assessment of the flexor pollicis longus tendon after plate fixation. Orthopedics. 2017;40:e104\u20138.","journal-title":"Orthopedics"},{"key":"882_CR10","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1142\/S0218810417500137","volume":"22","author":"S Tokunaga","year":"2017","unstructured":"Tokunaga S, Abe Y. Asymptomatic flexor tendon damages after volar locking plate fixation of distal radius fractures. J Hand Surg Asian Pac. 2017;22:75\u201382.","journal-title":"J Hand Surg Asian Pac"},{"key":"882_CR11","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1016\/j.jhsa.2015.11.022","volume":"41","author":"A Kara","year":"2016","unstructured":"Kara A, Celik H, Bankaoglu M, et al. Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures. J Hand Surg Am. 2016;41:374\u201380.","journal-title":"J Hand Surg Am"},{"key":"882_CR12","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10396-015-0670-0","volume":"43","author":"M Nanno","year":"2016","unstructured":"Nanno M, Kodera N, Tomori Y, et al. Transverse ultrasound assessment of the flexor pollicis longus tendon movement on the distal radius during wrist and finger motion in distal radius fracture with volar plating. J Med Ultrason. 2016;43:29\u201336.","journal-title":"J Med Ultrason"},{"key":"882_CR13","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1016\/j.jhsa.2014.01.038","volume":"39","author":"R Limthongthang","year":"2014","unstructured":"Limthongthang R, Bachoura A, Jacoby SM, et al. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am. 2014;39:852\u201360.","journal-title":"J Hand Surg Am"},{"key":"882_CR14","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1142\/S0218810400000223","volume":"5","author":"JL Orbay","year":"2000","unstructured":"Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5:103\u201312.","journal-title":"Hand Surg"},{"key":"882_CR15","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1007\/s11552-009-9180-0","volume":"4","author":"MN Adham","year":"2009","unstructured":"Adham MN, Porembski M, Adham C. Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (N Y). 2009;4:406\u20139.","journal-title":"Hand (N Y)"},{"key":"882_CR16","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jhsa.2007.11.011","volume":"33","author":"AW Cross","year":"2008","unstructured":"Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am. 2008;33:164\u20137.","journal-title":"J Hand Surg Am"},{"key":"882_CR17","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.jhsa.2010.09.033","volume":"36","author":"M Soong","year":"2011","unstructured":"Soong M, van Leerdam R, Guitton TG, et al. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36:3\u20139.","journal-title":"J Hand Surg Am"},{"key":"882_CR18","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1016\/j.jhsa.2015.03.023","volume":"40","author":"H Yamazaki","year":"2015","unstructured":"Yamazaki H, Uchiyama S, Komatsu M, et al. Risk assessment of tendon attrition following treatment of distal radius fractures with volar locking plates using audible crepitus and placement of the plate: a prospective clinical cohort study. J Hand Surg Am. 2015;40:1571\u201381.","journal-title":"J Hand Surg Am"},{"key":"882_CR19","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1142\/S0218810413720246","volume":"18","author":"YC Chiu","year":"2013","unstructured":"Chiu YC, Kao FC, Tu YK. Flexor pollicis longus tendon entrapment after performing minimally invasive plate osteosynthesis of a distal radius fracture: a case report. Hand Surg. 2013;18:403\u20136.","journal-title":"Hand Surg"}],"container-title":["Journal of Medical Ultrasonics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10396-018-0882-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10396-018-0882-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10396-018-0882-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T09:42:26Z","timestamp":1604223746000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10396-018-0882-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,27]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["882"],"URL":"https:\/\/doi.org\/10.1007\/s10396-018-0882-1","relation":{},"ISSN":["1346-4523","1613-2254"],"issn-type":[{"value":"1346-4523","type":"print"},{"value":"1613-2254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,27]]},"assertion":[{"value":"12 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1964 and later versions.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statements"}},{"value":"Informed consent was obtained from the patient in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Takuya Uemura, Tadashi Okano, Ema Onode, Takuya Yokoi, Kosuke Shintani, Mitsuhiro Okada, and Hiroaki Nakamura declare that they have no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}