{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T23:40:03Z","timestamp":1784763603988,"version":"3.55.0"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T00:00:00Z","timestamp":1716422400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T00:00:00Z","timestamp":1716422400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Ultrasonics"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Sonazoid, an ultrasound contrast agent, has been covered by insurance in Japan since January 2007 for the diagnosis of hepatic mass lesions and is widely used for diagnosing not only primary liver cancer but also liver metastases such as those from breast cancer and colorectal cancer. Contrast-enhanced ultrasound for breast mass lesions has been covered by insurance since August 2012 after phase II and phase III clinical trials showed that the diagnostic performance was significantly superior to that of B-mode and contrast-enhanced magnetic resonance imaging. This paper describes the principles of imaging techniques in contrast-enhanced ultrasonography including the filter, pulse inversion, amplitude modulation, and amplitude-modulated pulse inversion methods. The pulse inversion method, which visualizes the second-harmonic component using the nonlinear scattering characteristics of the contrast agent, is widely used regardless of the contrast agent and target organ because of its high resolution. Sonazoid has a stiffer shell and requires a higher acoustic amplitude than Sonovue to generate nonlinear vibrations. The higher transmitted sound pressure generates more tissue harmonic components. Since pulse inversion allows visualization of the tissue harmonic components, amplitude modulation and amplitude-modulated pulse inversion, which include few tissue harmonic components, are primarily used. Amplitude modulation methods detect nonlinear signals from the contrast agent in the fundamental band. The mechanism of the amplitude modulation is considered to be changes in the echo signal\u2019s phase depending on the sound pressure. Since the tissue-derived component is minor in amplitude modulation methods, good contrast sensitivity can be obtained.<\/jats:p>","DOI":"10.1007\/s10396-024-01443-x","type":"journal-article","created":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T07:01:56Z","timestamp":1716447716000},"page":"567-580","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Principle of contrast-enhanced ultrasonography"],"prefix":"10.1007","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-9654-9572","authenticated-orcid":false,"given":"Yoshitaka","family":"Mine","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Etsuo","family":"Takada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsutoshi","family":"Sugimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuminori","family":"Moriyasu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,23]]},"reference":[{"key":"1443_CR1","unstructured":"The International Contrast Ultrasound Society (ICUS): https:\/\/icus-society.org\/getting-started\/finding-an-agent\/ (Accessed 14 Feb, 2024)"},{"key":"1443_CR2","doi-asserted-by":"publisher","first-page":"86","DOI":"10.2214\/AJR.08.1618","volume":"193","author":"F Moriyasu","year":"2009","unstructured":"Moriyasu F, Itoh K. Efficacy of perflubutane microbubble-enhanced ultrasound in the characterization and detection of focal liver lesions: phase 3 multicenter clinical trial. AJR. 2009;193:86\u201395.","journal-title":"AJR"},{"key":"1443_CR3","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s10396-011-0342-7","volume":"39","author":"Y Miyamoto","year":"2012","unstructured":"Miyamoto Y, Ito T, Takada E, et al. Phase II Clinical Study of DD-723 (perflubutane): dose-response study in patients with breast tumors. J Med Ultrasonics. 2012;39:79\u201386.","journal-title":"J Med Ultrasonics"},{"key":"1443_CR4","doi-asserted-by":"publisher","first-page":"W400","DOI":"10.2214\/AJR.12.10518","volume":"202","author":"Y Miyamoto","year":"2014","unstructured":"Miyamoto Y, Ito T, Takada E, et al. Efficacy of Sonazoid (perflubutane) for contrast-enhanced ultrasound in the differentiation of focal breast lesions: phase 3 multicenter clinical trial. AJR. 2014;202:W400\u20137.","journal-title":"AJR"},{"key":"1443_CR5","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3179\/jjmu.JJMU.R.168","volume":"47","author":"T Ito","year":"2020","unstructured":"Ito T. Diagnostic criteria for contrast-enhanced ultrasound in the differentiation of focal breast lesions. Jpn J Med Ultrasonics. 2020;47:53\u20139.","journal-title":"Jpn J Med Ultrasonics"},{"key":"1443_CR6","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1254\/fpj.130.413","volume":"130","author":"M Matsumura","year":"2007","unstructured":"Matsumura M, Sugihara H. Basic and clinical profile of perflubutane (Sonazoid powder for injection). Folia Pharmacol Jpn. 2007;130:413\u201320.","journal-title":"Folia Pharmacol Jpn"},{"key":"1443_CR7","unstructured":"GE HealthCare: Interview form for Sonazoid. https:\/\/www.gehealthcare.co.jp\/products\/pharma\/sonazoid (Accessed 14 Feb, 2024)"},{"key":"1443_CR8","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1016\/j.ultrasmedbio.2007.11.006","volume":"34","author":"PC Sontum","year":"2008","unstructured":"Sontum PC. Physicochemical characteristics of Sonazoid\u2122, a new contrast agent for ultrasound imaging. Ultrasound Med Biol. 2008;34:824\u201333.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR9","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1097\/00004424-199904000-00003","volume":"34","author":"PC Sontum","year":"1999","unstructured":"Sontum PC, et al. Acoustic properties of NC100100 and their relation with the microbubble size distribution. Invest Radiol. 1999;34:268\u201375.","journal-title":"Invest Radiol"},{"key":"1443_CR10","first-page":"S270","volume":"23","author":"Y Kono","year":"1996","unstructured":"Kono Y, Moriyasu F, Nada T, et al. Properties of ultrasound contrast agent (2)\u2014study with harmonic imaging. Jpn J Med Ultrasonics. 1996;23:S270.","journal-title":"Jpn J Med Ultrasonics"},{"key":"1443_CR11","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.1109\/TUFFC.2020.3034532","volume":"68","author":"SB Keller","year":"2021","unstructured":"Keller SB, Sheeran PS, Averkiou MA. Cavitation therapy monitoring of commercial microbubbles with a clinical scanner. IEEE Trans Ultrason Ferroelectr Freq Control. 2021;68:1144\u201354.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"1443_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3350\/cmh.2013.19.1.1","volume":"19","author":"JY Jang","year":"2013","unstructured":"Jang JY, Kim MY, Jeong SW, et al. Current consensus and guidelines of contrast enhanced ultrasound for the characterization of focal liver lesions. Clin Mol Hepatol. 2013;19:1\u201316.","journal-title":"Clin Mol Hepatol"},{"key":"1443_CR13","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1121\/1.395410","volume":"82","author":"S Saito","year":"1987","unstructured":"Saito S, Akashi N, Kushibiki J. Second-harmonic component of a nonlinearly distorted wave in a focused sound field. J Acoust Soc Am. 1987;82:621\u20138.","journal-title":"J Acoust Soc Am"},{"key":"1443_CR14","first-page":"969","volume":"28","author":"S Saito","year":"2001","unstructured":"Saito S. Nonlinear acoustic field of focused ultrasound. J Med Ultrasonics. 2001;28:969\u201376.","journal-title":"J Med Ultrasonics"},{"key":"1443_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4899-4794-9","volume-title":"Theoretical foundations of nonlinear acoustics. Translated by Beyer RT","author":"OV Rudenko","year":"1977","unstructured":"Rudenko OV, Soluyan SI. Theoretical foundations of nonlinear acoustics. Translated by Beyer RT. New York: Consultant Bureau; 1977."},{"key":"1443_CR16","unstructured":"Kamakura T. Fundamentals of nonlinear acoustics. Aichi Shuppan, 1996; 61\u2013125."},{"key":"1443_CR17","volume-title":"Nonlinear acoustics","author":"MF Hamilton","year":"1997","unstructured":"Hamilton MF, Blackstock DT. Nonlinear acoustics. New York: Academic Press; 1997."},{"key":"1443_CR18","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1121\/1.385942","volume":"69","author":"JN Tj\u00f8tta","year":"1981","unstructured":"Tj\u00f8tta JN, T\u00f8tta S. Nonlinear equations of acoustics with application to parametric acoustic arrays. J Acoust Soc Am. 1981;69:1644\u201352.","journal-title":"J Acoust Soc Am"},{"key":"1443_CR19","doi-asserted-by":"publisher","first-page":"1522","DOI":"10.1121\/1.390155","volume":"74","author":"BG Lucas","year":"1983","unstructured":"Lucas BG, Muir TG. Field of a finit-amplitude forcusing source. J Acoust Soc Am. 1983;74:1522\u20138.","journal-title":"J Acoust Soc Am"},{"key":"1443_CR20","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1016\/0301-5629(93)90080-8","volume":"19","author":"BA Schrope","year":"1993","unstructured":"Schrope BA, Newhouse VL. Second-harmonic ultrasonic blood perfusion measurement. Ultrasound Med Biol. 1993;19:567\u201379.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR21","first-page":"205A","volume":"25","author":"K Miyatake","year":"1995","unstructured":"Miyatake K, Uematsu M, Matsuda H, et al. Harmonic contrast echocardiography: a new method for detecting myocardial opacification after intravenous injection of contrast. J ACC. 1995;25:205A.","journal-title":"J ACC"},{"key":"1443_CR22","first-page":"230","volume":"197","author":"F Moriyasu","year":"1995","unstructured":"Moriyasu F, Ito Y, Nada T, et al. Gray-scale second-harmonic imaging of the liver with galactose-based microbubble. Radiology. 1995;197:230.","journal-title":"Radiology"},{"key":"1443_CR23","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.ultrasmedbio.2019.11.004","volume":"46","author":"MA Averkiou","year":"2020","unstructured":"Averkiou MA, Bruce MF, Powers JE, et al. Imaging methods for ultrasound contrast agents. Ultrasound Med Biol. 2020;46:498\u2013517.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR24","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1016\/j.ultrasmedbio.2019.12.008","volume":"46","author":"P Frinking","year":"2020","unstructured":"Frinking P, Segers S, Luan Y, et al. Three decades of ultrasound contrast agents: a review of the past, present and future improvements. Ultrasound Med Biol. 2020;46:892\u2013908.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR25","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1097\/00004424-199702000-00008","volume":"32","author":"Y Kono","year":"1997","unstructured":"Kono Y, Moriyasu F, Mine Y, et al. Gray-scale second-harmonic imaging of the liver with galactose-based microbubbles. Invest Radiol. 1997;32:120\u20135.","journal-title":"Invest Radiol"},{"key":"1443_CR26","doi-asserted-by":"crossref","unstructured":"Burns PN, Powers JE, Simpson DH, et al. Harmonic power mode Doppler using microbubble contrast agents: An improved method for small vessel flow imaging. In: 1994 Proceedings of IEEE Ultrasonics Symposium. 1994. p. 1547\u201350.","DOI":"10.1109\/ULTSYM.1994.401886"},{"key":"1443_CR27","doi-asserted-by":"crossref","unstructured":"Simpson DH, Burns PN. Pulse Inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents. In: 1997 IEEE ultrasonics symposium proceedings. An international symposium. 1997. p. 1597\u2013600.","DOI":"10.1109\/ULTSYM.1997.663301"},{"key":"1443_CR28","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1109\/58.753026","volume":"46","author":"D Hope Simpson","year":"1999","unstructured":"Hope Simpson D, Chin CT, Burns PN. Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. IEEE Trans Ultrason Ferroelectr Freq Control. 1999;46:372\u201382.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"1443_CR29","first-page":"S167","volume":"30","author":"T Sato","year":"2003","unstructured":"Sato T, Mine Y. Contrast echo imaging using non-linear signals from fundamental frequency band. Jpn J Med Ultrasonics. 2003;30:S167.","journal-title":"Jpn J Med Ultrasonics"},{"key":"1443_CR30","first-page":"S115","volume":"31","author":"T Sato","year":"2004","unstructured":"Sato T, Kawagishi T, Kamiyama N, et al. The property of non-linear signals at the fundamental frequency band using amplitude modulation. Jpn J Med Ultrasonics. 2004;31:S115.","journal-title":"Jpn J Med Ultrasonics"},{"key":"1443_CR31","first-page":"S245","volume":"31","author":"F Moriyasu","year":"2004","unstructured":"Moriyasu F, Sato T, Kamiyama N, et al. Comparison between phase modulation and amplitude modulation methods in ultrasound contrast imaging of the liver with next generation contrast agents. Jpn J Med Ultrasonics. 2004;31:S245.","journal-title":"Jpn J Med Ultrasonics"},{"key":"1443_CR32","unstructured":"Brock-Fisher GA, Poland MD, Rafter PG. Means for increasing sensitivity in non-linear ultrasound imaging systems. 1996; US5577505A."},{"key":"1443_CR33","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1161\/01.CIR.104.3.352","volume":"104","author":"V Mor-Avi","year":"2001","unstructured":"Mor-Avi V, Caiani EG, Collins KA, et al. Combined assessment of myocardial perfusion and regional left ventricular function by analysis of contrast-enhanced power modulation images. Circulation. 2001;104:352\u20137.","journal-title":"Circulation"},{"key":"1443_CR34","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1109\/TUFFC.2021.3050481","volume":"68","author":"TY Lai","year":"2021","unstructured":"Lai TY, Averkiou MA. Linear signal cancellation of nonlinear pulsing schemes in a verasonics research scanner. IEEE Trans Ultrason Ferroelectr Freq Control. 2021;68:1721\u20138.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"1443_CR35","doi-asserted-by":"publisher","first-page":"2676","DOI":"10.1109\/TUFFC.2012.2508","volume":"59","author":"O Couture","year":"2012","unstructured":"Couture O, Fink M, Tanter M. Ultrasound contrast plane wave imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2012;59:2676\u201383.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"1443_CR36","doi-asserted-by":"crossref","unstructured":"Phillips PJ. Contrast pulse sequences (CPS): Imaging nonlinear microbubbles. Proc IEEE Int Ultrason Symp. 2001; 1739\u201345.","DOI":"10.1109\/ULTSYM.2001.992057"},{"key":"1443_CR37","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1007\/s10406-004-0075-4","volume":"14","author":"P Phillips","year":"2004","unstructured":"Phillips P, Gardner E. Contrast-agent detection and quantification. Eur Radiol. 2004;14:4\u201310.","journal-title":"Eur Radiol"},{"key":"1443_CR38","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.ultrasmedbio.2004.10.004","volume":"31","author":"RJ Eckersley","year":"2005","unstructured":"Eckersley RJ, Chin CT, Burns PN. Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power. Ultrasound Med Biol. 2005;31:213\u20139.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR39","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1080\/14786440808635681","volume":"34","author":"L Rayleigh","year":"1917","unstructured":"Rayleigh L. On the pressure developed in a liquid during the collapse of a spherical cavity. Phil Mag. 1917;34:94\u20138.","journal-title":"Phil Mag"},{"key":"1443_CR40","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1115\/1.4009975","volume":"16","author":"MS Plesset","year":"1949","unstructured":"Plesset MS. The dynamics of cavitation bubbles. Trans ASME J Appl Mech. 1949;16:277\u201382.","journal-title":"Trans ASME J Appl Mech"},{"key":"1443_CR41","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1121\/1.380884","volume":"59","author":"W Lauterborn","year":"1976","unstructured":"Lauterborn W. Numerical investigation of nonlinear oscillations of gas bubbles in liquids. J Acousr Soc Amer. 1976;59:283\u201393.","journal-title":"J Acousr Soc Amer"},{"key":"1443_CR42","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1121\/1.389844","volume":"74","author":"RE Glazman","year":"1983","unstructured":"Glazman RE. Effects of adsorbed films on gas bubble radial oscillations. J Acoust Soc Amer. 1983;74:980\u20136.","journal-title":"J Acoust Soc Amer"},{"key":"1443_CR43","first-page":"214","volume":"59","author":"K Vorkurka","year":"1986","unstructured":"Vorkurka K. Comparison of Rayleigh\u2019s, Herring\u2019s, and Gilmore\u2019s models of gas bubbles. Acustica. 1986;59:214\u20139.","journal-title":"Acustica"},{"key":"1443_CR44","first-page":"187","volume-title":"The Acoustic Bubble","author":"TG Leighton","year":"1994","unstructured":"Leighton TG. The Acoustic Bubble. New York: Academic Press; 1994. p. 187\u20138 (P.100, 106)."},{"key":"1443_CR45","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1121\/1.412091","volume":"97","author":"CC Church","year":"1995","unstructured":"Church CC. The effects of an elastic solid surface layer on the radial pulsations of gas bubbles. J Acoust Soc Amer. 1995;97:1510\u201321.","journal-title":"J Acoust Soc Amer"},{"key":"1443_CR46","doi-asserted-by":"crossref","unstructured":"Hoff L, Sontum PC, Hoff B. Acoustic properties of shell- encapsulated, gas-filled ultrasound contrast agents. In: Proceeding of IEEE Ultrason Symp San Antonio TX. 1996; 2: 1441\u20134.","DOI":"10.1109\/ULTSYM.1996.584337"},{"key":"1443_CR47","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/S0301-5629(98)00009-X","volume":"24","author":"PJA Frinking","year":"1998","unstructured":"Frinking PJA, de Jong N. Acoustic modeling of shell- encapsulated gas bubbles. Ultrasound Med Biol. 1998;24:523\u201333.","journal-title":"Ultrasound Med Biol"},{"key":"1443_CR48","doi-asserted-by":"publisher","first-page":"415","DOI":"10.3811\/jjmf.25.415","volume":"25","author":"H Kubo","year":"2012","unstructured":"Kubo H, Sato A, Ito S, et al. Nonlinear oscillation of an insonified microbubble with shell-coating. Jpn J Multiphase Flow. 2012;25:415\u201322.","journal-title":"Jpn J Multiphase Flow"},{"key":"1443_CR49","first-page":"3","volume-title":"Frontiers of micro-bubbles","author":"The Japan Society of Mechanical Engineers. ed","year":"2006","unstructured":"The Japan Society of Mechanical Engineers. ed. Frontiers of micro-bubbles. Tokyo: Kyoritsu Publishing; 2006. p. 3\u201321."},{"key":"1443_CR50","doi-asserted-by":"publisher","first-page":"3499","DOI":"10.1121\/1.2109427","volume":"118","author":"P Marmottant","year":"2005","unstructured":"Marmottant P, van der Meer S, Emmer M, et al. A model for large amplitude oscillations of coated bubbles accounting for buckling and rupture. J Acoust Soc Amer. 2005;118:3499\u2013505.","journal-title":"J Acoust Soc Amer"},{"key":"1443_CR51","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1109\/58.883539","volume":"47","author":"KE Morgan","year":"2000","unstructured":"Morgan KE, Allen JS, Dayton PA, et al. Experimental and theoretical evaluation of microbubble behaviour: effect of transmitted phase and bubble size. IEEE Trans Ultrason Ferroelect Freq Contr. 2000;47:1494.","journal-title":"IEEE Trans Ultrason Ferroelect Freq Contr"},{"key":"1443_CR52","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1109\/58.710539","volume":"45","author":"K Morgan","year":"1998","unstructured":"Morgan K, Averkiou M, Ferrara K. Effect of the phase of transmission on contrast agent echoes. IEEE Trans Ultrason Ferroelect Freq Contr. 1998;45:872\u20135.","journal-title":"IEEE Trans Ultrason Ferroelect Freq Contr"},{"key":"1443_CR53","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1109\/TUFFC.2022.3143810","volume":"69","author":"SB Keller","year":"2022","unstructured":"Keller SB, Lai TY, Koninck LD, et al. Investigation of the phase of nonlinear echoes from microbubbles during amplitude modulation. IEEE Trans Ultrason Ferroelect Freq Contr. 2022;69:1032\u201340.","journal-title":"IEEE Trans Ultrason Ferroelect Freq Contr"},{"key":"1443_CR54","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.1109\/TUFFC.2018.2841848","volume":"65","author":"C Tremblay-Darveau","year":"2018","unstructured":"Tremblay-Darveau C, Sheeran PS, Vu CK, et al. The role of microbubble echo phase lag in multipulse contrast-enhanced ultrasound imaging. IEEE Trans Ultrason Ferroelect Freq Contr. 2018;65:1389\u2013401.","journal-title":"IEEE Trans Ultrason Ferroelect Freq Contr"}],"updated-by":[{"DOI":"10.1007\/s10396-024-01500-5","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,9,21]],"date-time":"2024-09-21T00:00:00Z","timestamp":1726876800000}}],"container-title":["Journal of Medical Ultrasonics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10396-024-01443-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10396-024-01443-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10396-024-01443-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T05:15:12Z","timestamp":1729746912000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10396-024-01443-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,23]]},"references-count":54,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["1443"],"URL":"https:\/\/doi.org\/10.1007\/s10396-024-01443-x","relation":{"correction":[{"id-type":"doi","id":"10.1007\/s10396-024-01500-5","asserted-by":"object"}]},"ISSN":["1346-4523","1613-2254"],"issn-type":[{"value":"1346-4523","type":"print"},{"value":"1613-2254","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,23]]},"assertion":[{"value":"19 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2024","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s10396-024-01500-5","URL":"https:\/\/doi.org\/10.1007\/s10396-024-01500-5","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human or animal subjects performed by any authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}