{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T01:19:32Z","timestamp":1783473572770,"version":"3.55.0"},"reference-count":72,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2013,7,18]],"date-time":"2013-07-18T00:00:00Z","timestamp":1374105600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1007\/s10439-013-0864-9","type":"journal-article","created":{"date-parts":[[2013,7,17]],"date-time":"2013-07-17T16:57:10Z","timestamp":1374080230000},"page":"2515-2527","source":"Crossref","is-referenced-by-count":68,"title":["A Robust 3D Finite Element Simulation of Human Proximal Femur Progressive Fracture Under Stance Load with Experimental Validation"],"prefix":"10.1007","volume":"41","author":[{"given":"Ridha","family":"Hambli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samir","family":"Allaoui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,7,18]]},"reference":[{"key":"864_CR1","unstructured":"Abaqus 6.11 Documentation, Analysis User\u2019s Manual."},{"issue":"3","key":"864_CR2","first-page":"599","volume":"49","author":"AA Abdel-Wahab","year":"2011","unstructured":"Abdel-Wahab, A. A., and V. V. Silberschmidt. Numerical modeling of impact fracture of cortical bone tissue using X-FEM. J. Theor. Appl. Mech. 49(3):599\u2013619, 2011.","journal-title":"J. Theor. Appl. Mech."},{"issue":"1","key":"864_CR3","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1115\/1.1428745","volume":"124","author":"TL Arthur Moore","year":"2002","unstructured":"Arthur Moore, T. L., and L. J. Gibson. Microdamage accumulation in bovine trabecular bone in uniaxial compression. J. Biomech. Eng. 124(1):63\u201371, 2002.","journal-title":"J. Biomech. Eng."},{"key":"864_CR4","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/j.medengphy.2007.12.009","volume":"30","author":"V Baca","year":"2008","unstructured":"Baca, V., Z. Horak, P. Mikulenka, and V. Dzupa. Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses. Med. Eng. Phys. 30:924\u2013930, 2008.","journal-title":"Med. Eng. Phys."},{"key":"864_CR5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0021-9290(03)00257-4","volume":"37","author":"HH Bayraktar","year":"2004","unstructured":"Bayraktar, H. H., E. F. Morgan, G. L. Niebur, G. E. Morris, E. K. Wong, and T. M. Keaveny. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. J. Biomech. 37:27\u201335, 2004.","journal-title":"J. Biomech."},{"key":"864_CR6","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.jbiomech.2006.08.003","volume":"40","author":"M Bessho","year":"2007","unstructured":"Bessho, M., I. Ohnishi, J. Matsuyama, T. Matsumoto, K. Imai, and K. Nakamura. Prediction of strength and strain of the proximal femur by a CT-based finite element method. J. Biomech. 40:1745\u20131753, 2007.","journal-title":"J. Biomech."},{"key":"864_CR7","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1002\/nme.2791","volume":"82","author":"E Budyn","year":"2010","unstructured":"Budyn, E., and T. Hoc. Analysis of micro fracture in human Haversian cortical bone under transverse tension using extended physical imaging. Int. J. Numer. Methods Eng. 82:940\u2013965, 2010.","journal-title":"Int. J. Numer. Methods Eng."},{"key":"864_CR8","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/00003086-199011000-00047","volume":"260","author":"DB Burr","year":"1990","unstructured":"Burr, D. B., and T. Stafford. Validity of the bulk-staining technique to separate artifactual from in vivo bone microdamage. Clin. Orthop. Relat. Res. 260:305\u2013308, 1990.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"864_CR9","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/0029-5493(81)90007-8","volume":"64","author":"JL Chaboche","year":"1981","unstructured":"Chaboche, J. L. Continuum damage mechanics: a tool to describe phenomena before crack initiation. Nucl. Eng. Des. 64:233\u2013247, 1981.","journal-title":"Nucl. Eng. Des."},{"key":"864_CR10","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/0379-0738(94)90265-8","volume":"65","author":"DW Cotton","year":"1994","unstructured":"Cotton, D. W., C. L. Whitehead, S. Vyas, C. Cooper, and E. A. Patterson. Are hip fractures caused by falling and breaking or breaking and falling? Photoelastic stress analysis. Forensic Sci. Int. 65:105\u2013112, 1994.","journal-title":"Forensic Sci. Int."},{"key":"864_CR11","doi-asserted-by":"crossref","first-page":"2837","DOI":"10.1016\/j.jbiomech.2007.03.015","volume":"40","author":"L Cristofolini","year":"2007","unstructured":"Cristofolini, L., M. Juszczyk, S. Martelli, F. Taddei, and M. Viceconti. In vitro replication of spontaneous fractures of the proximal human femur. J. Biomech. 40:2837\u20132845, 2007.","journal-title":"J. Biomech."},{"issue":"1920","key":"864_CR12","doi-asserted-by":"crossref","first-page":"2725","DOI":"10.1098\/rsta.2010.0046","volume":"368","author":"L Cristofolini","year":"2010","unstructured":"Cristofolini, L., E. Schileo, M. Juszczyk, F. Taddei, S. Martelli, and M. Viceconti. Mechanical testing of bones: the positive synergy of finite-element models and in vitro experiments. Philos. Trans. Math. Phys. Eng. Sci. 368(1920):2725\u20132763, 2010.","journal-title":"Philos. Trans. Math. Phys. Eng. Sci."},{"issue":"7","key":"864_CR13","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1111\/j.1532-5415.1994.tb06540.x","volume":"42","author":"RG Cumming","year":"1994","unstructured":"Cumming, R. G., and R. J. Klineberg. Fall frequency and characteristics and the risk of hip fracture. J. Am. Geriatr. Soc. 42(7):774\u2013778, 1994.","journal-title":"J. Am. Geriatr. Soc."},{"key":"864_CR14","doi-asserted-by":"crossref","DOI":"10.1515\/9781400849505","volume-title":"Bones: Structure and Mechanics","author":"JD Currey","year":"2002","unstructured":"Currey, J. D. Bones: Structure and Mechanics. Princeton: Princeton University Press, 2002."},{"key":"864_CR15","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.bone.2012.09.006","volume":"1","author":"E Dall\u2019Ara","year":"2013","unstructured":"Dall\u2019Ara, E., B. Luisier, R. Schmidt, F. Kainberger, P. Zysset, and D. Pahr. A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro. Bone 1:27\u201338, 2013.","journal-title":"Bone"},{"key":"864_CR16","doi-asserted-by":"crossref","unstructured":"Di Paola, M., F. Paolo Pinnola, and M. Zingales. A discrete mechanical model of fractional hereditary materials. Meccanica (on line), 2013.","DOI":"10.1007\/s11012-012-9685-4"},{"key":"864_CR17","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1122\/1.4717492","volume":"56","author":"M Paola Di","year":"2012","unstructured":"Di Paola, M., and M. Zingales. Exact mechanical models of fractional hereditary materials. J. Rheol. 56:983, 2012.","journal-title":"J. Rheol."},{"issue":"2","key":"864_CR18","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1007\/s10439-010-0196-y","volume":"39","author":"D Dragomir-Daescu","year":"2011","unstructured":"Dragomir-Daescu, D., J. Op Den Buijs, S. McEeligot, Y. Dai, R. C. Entwistle, C. Salas, J. Melton, III, E. Bennet, S. Khosla, and S. Amin. Robust QCT\/FEA models of proximal femur stiffness and fracture load during a sideways fall on the hip. Ann. Biomed. Eng. 39(2):742\u2013755, 2011.","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"864_CR19","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.jtbi.2009.05.021","volume":"260","author":"A Fritsch","year":"2009","unstructured":"Fritsch, A., C. Hellmich, and L. Dormieux. Ductile sliding between mineral crystals followed by rupture of collagen crosslinks: experimentally supported micromechanical explanation of bone strength. J. Theor. Biol. 260(2):230\u2013252, 2009.","journal-title":"J. Theor. Biol."},{"issue":"1\/2","key":"864_CR20","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s00170-008-1819-4","volume":"44","author":"F Gassara","year":"2009","unstructured":"Gassara, F., R. Hambli, T. Bouraoui, F. El Halouani, and D. Soulat. Optimization of springback in L-bending process using a coupled Abaqus\/Python algorithm. Int. J. Adv. Manuf. Technol. 44(1\/2):61\u201367, 2009.","journal-title":"Int. J. Adv. Manuf. Technol."},{"issue":"4","key":"864_CR21","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1002\/cnm.1413","volume":"27","author":"R Hambli","year":"2011","unstructured":"Hambli, R. Multiscale prediction of crack density and crack length accumulation in trabecular bone based on neural networks and finite element simulation. Int. J. Numer. Methods Biomed. Eng. 27(4):461\u2013475, 2011.","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"issue":"6","key":"864_CR22","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.jmbbm.2011.03.002","volume":"4","author":"R Hambli","year":"2011","unstructured":"Hambli, R. Apparent damage accumulation in cancellous bone using neural networks. J. Mech. Behav. Biomed. Mater. 4(6):868\u2013878, 2011.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"864_CR23","doi-asserted-by":"crossref","unstructured":"Hambli, R. A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion. Med. Biol. Eng. Comput. (Online), 2013.","DOI":"10.1007\/s11517-012-0986-5"},{"key":"864_CR24","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.jtbi.2012.02.007","volume":"301","author":"R Hambli","year":"2012","unstructured":"Hambli, R., and A. Barkaoui. Physically based 3D finite element model of a single mineralized collagen microfibril. J. Theor. Biol. 301:28\u201341, 2012.","journal-title":"J. Theor. Biol."},{"issue":"2","key":"864_CR25","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.medengphy.2011.07.011","volume":"34","author":"R Hambli","year":"2012","unstructured":"Hambli, R., A. Bettamer, and S. Allaoui. Finite element prediction of proximal femur fracture pattern based on orthotropic behaviour law coupled to quasi-brittle damage. Med. Eng. Phys. 34(2):202\u2013210, 2012.","journal-title":"Med. Eng. Phys."},{"issue":"3","key":"864_CR26","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1007\/BF00298717","volume":"52","author":"WC Hayes","year":"1993","unstructured":"Hayes, W. C., E. R. Myers, J. N. Morris, T. N. Gerhart, H. S. Yett, and L. A. Lipsitz. Impact near the hip dominates fracture risk in elderly nursing home residents who fall. Calcif. Tissue Int. 52(3):192\u2013198, 1993.","journal-title":"Calcif. Tissue Int."},{"issue":"S1","key":"864_CR27","first-page":"389","volume":"6","author":"Ch Hellmich","year":"2012","unstructured":"Hellmich, Ch., A. Dejaco, and St. Scheiner. Multiscale mechanics and mechanobiology for bone and bone tissue engineering. J. Tissue Eng. Regen. Med. 6(S1):389, 2012.","journal-title":"J. Tissue Eng. Regen. Med."},{"issue":"12","key":"864_CR28","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1016\/j.jbiomech.2011.05.038","volume":"44","author":"MM Juszczyk","year":"2011","unstructured":"Juszczyk, M. M., L. Cristofolini, and M. Viceconti. The human proximal femur behaves linearly elastic up to failure under physiological loading conditions. J. Biomech. 44(12):2259\u20132266, 2011.","journal-title":"J. Biomech."},{"issue":"6","key":"864_CR29","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/S1350-4533(03)00030-4","volume":"25","author":"TS Kaneko","year":"2003","unstructured":"Kaneko, T. S., M. R. Pejcic, J. Tehranzadeh, and J. H. Keyak. Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions. Med. Eng. Phys. 25(6):445\u2013454, 2003.","journal-title":"Med. Eng. Phys."},{"key":"864_CR30","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1002\/jor.1100170308","volume":"17","author":"TM Keaveny","year":"1999","unstructured":"Keaveny, T. M., E. F. Wachtel, and D. L. Kopperdahl. Mechanical behavior of human trabecular bone after overloading. J. Orthop. Res. 17:346\u2013353, 1999.","journal-title":"J. Orthop. Res."},{"issue":"4","key":"864_CR31","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0021-9290(99)00202-X","volume":"33","author":"JH Keyak","year":"2000","unstructured":"Keyak, J. H. Relationships between femoral fracture loads for two load configurations\u201d. J. Biomech. 33(4):499\u2013502, 2000.","journal-title":"J. Biomech."},{"key":"864_CR32","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/S1350-4533(01)00045-5","volume":"23","author":"JH Keyak","year":"2001","unstructured":"Keyak, J. H. Improved prediction of proximal femoral fracture load using nonlinear finite element models. Med. Eng. Phys. 23:165\u2013173, 2001.","journal-title":"Med. Eng. Phys."},{"key":"864_CR33","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/S1350-4533(03)00081-X","volume":"25","author":"JH Keyak","year":"2003","unstructured":"Keyak, J. H., and Y. Falkinstein. Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load. Med. Eng. Phys. 25:781\u2013787, 2003.","journal-title":"Med. Eng. Phys."},{"key":"864_CR34","first-page":"389","volume":"12","author":"J Keyak","year":"1990","unstructured":"Keyak, J., J. Meagher, H. Skinner, and J. Mote. Automated three-dimensional finite element modelling of bone: a new method. ASME J. Biomech. Eng. 12:389\u2013397, 1990.","journal-title":"ASME J. Biomech. Eng."},{"key":"864_CR35","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1016\/S1350-4533(01)00094-7","volume":"23","author":"JH Keyak","year":"2001","unstructured":"Keyak, J. H., S. A. Rossi, K. A. Jones, C. M. Les, and H. B. Skinner. Prediction of fracture location in the proximal femur using finite element models. Med. Eng. Phys. 23:657\u2013664, 2001.","journal-title":"Med. Eng. Phys."},{"key":"864_CR36","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0021-9290(97)00123-1","volume":"31","author":"JH Keyak","year":"1998","unstructured":"Keyak, J. H., S. A. Rossi, K. A. Jones, and H. B. Skinner. Prediction of femoral fracture load using automated finite element modeling. J. Biomech. 31:125\u2013133, 1998.","journal-title":"J. Biomech."},{"key":"864_CR37","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/0141-5425(92)90100-Y","volume":"14","author":"JH Keyak","year":"1992","unstructured":"Keyak, J. H., and H. B. Skinner. Three-dimensional finite element modelling of bone: effects of element size. J. Biomed. Eng. 14:483\u2013489, 1992.","journal-title":"J. Biomed. Eng."},{"issue":"4","key":"864_CR38","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.bone.2012.01.012","volume":"50","author":"JE Koivum\u00e4ki","year":"2012","unstructured":"Koivum\u00e4ki, J. E., J. Thevenot, P. Pulkkinen, V. Kuhn, T. M. Link, F. Eckstein, and T. J\u00e4ms\u00e4. Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur. Bone 50(4):824\u2013829, 2012.","journal-title":"Bone"},{"issue":"11","key":"864_CR39","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/S0021-9290(03)00169-6","volume":"36","author":"SP Kotha","year":"2003","unstructured":"Kotha, S. P., and N. Guzelsu. Tensile damage and its effects on cortical bone. J. Biomech. 36(11):1683\u20131689, 2003.","journal-title":"J. Biomech."},{"key":"864_CR40","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1038\/361511a0","volume":"361","author":"RS Lakes","year":"1993","unstructured":"Lakes, R. S. Materials with structural hierarchy. Nature 361:511\u2013515, 1993.","journal-title":"Nature"},{"key":"864_CR41","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1115\/1.3225775","volume":"107","author":"J Lemaitre","year":"1985","unstructured":"Lemaitre, J. A continuous damage mechanics model for ductile fracture. J. Eng. Mater. Technol. 107:83\u201389, 1985.","journal-title":"J. Eng. Mater. Technol."},{"key":"864_CR42","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1007\/s00223-001-2132-5","volume":"72","author":"M Link","year":"2003","unstructured":"Link, M., V. Vieth, R. Langenberg, N. Meier, A. Lotter, D. Newitt, and S. Majumdar. Structure analysis of high resolution magnetic resonance imaging of the proximal femur: in vitro correlation with biomechanical strength and BMD. Calc. Tissue Int. 72:156\u2013165, 2003.","journal-title":"Calc. Tissue Int."},{"key":"864_CR43","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1115\/1.2895412","volume":"113","author":"JC Lotz","year":"1991","unstructured":"Lotz, J. C., E. J. Cheal, and W. C. Hayes. Fracture prediction for the proximal femur using finite element models. Part I. Linear analysis. J. Biomech. Eng. 113:353\u2013360, 1991.","journal-title":"J. Biomech. Eng."},{"key":"864_CR44","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0021-9290(02)00362-7","volume":"36","author":"L Malik","year":"2003","unstructured":"Malik, L., M. Stover, B. Martin, and C. Gibeling. Equine cortical bone exhibits rising R-curve fracture mechanics. J. Biomech. 36:191\u2013198, 2003.","journal-title":"J. Biomech."},{"key":"864_CR45","first-page":"251","volume":"1","author":"S Martelli","year":"2005","unstructured":"Martelli, S., F. Taddei, E. Varini, L. Cristofolini, L. Gill, and M. Viceconti. Accuracy of subject specific finite-element models of long bones from CT data: an in vitro study. Proc. ICCB II 1:251\u2013265, 2005.","journal-title":"Proc. ICCB II"},{"key":"864_CR46","volume-title":"Structure, Function, and Adaptation of Compact Bone","author":"RB Martin","year":"1989","unstructured":"Martin, R. B., and D. B. Burr. Structure, Function, and Adaptation of Compact Bone. New York: Raven, 1989."},{"key":"864_CR47","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0140-6736(05)66870-5","volume":"366","author":"PM Mayhew","year":"2005","unstructured":"Mayhew, P. M., C. D. Thomas, J. G. Clement, N. Loveridge, T. J. Beck, W. Bonfield, C. J. Burgoyne, and J. Reeve. Relation between age, femoral neck cortical stability, and hip fracture risk. Lancet 366:129\u2013135, 2005.","journal-title":"Lancet"},{"key":"864_CR48","doi-asserted-by":"crossref","first-page":"3327","DOI":"10.1016\/0020-7683(96)00015-7","volume":"33","author":"J Mazars","year":"1996","unstructured":"Mazars, J., and G. Pijaudier-Cabot. From Damage to fracture mechanics and conversely: a combined approach. Int. J. Solid Struct. 33:3327\u20133342, 1996.","journal-title":"Int. J. Solid Struct."},{"key":"864_CR49","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1177\/105678959500400303","volume":"4","author":"S Murakami","year":"1995","unstructured":"Murakami, S., and Y. Liu. Mesh-dependence in local approach to creep fracture. Int. J. Damage Mech 4:230\u2013250, 1995.","journal-title":"Int. J. Damage Mech"},{"key":"864_CR50","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.jbiomech.2004.05.013","volume":"38","author":"S Nagaraja","year":"2005","unstructured":"Nagaraja, S., T. L. Couse, and R. E. Guldberg. Trabecular bone microdamage and microstructural stresses under uniaxial compression. J. Biomech. 38:707\u2013716, 2005.","journal-title":"J. Biomech."},{"issue":"2","key":"864_CR51","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/s007740050072","volume":"17","author":"T Ota","year":"1999","unstructured":"Ota, T., I. Yamamoto, and R. Morita. Fracture simulation of femoral bone using finite-element method: how a fracture initiates and proceeds. J. Bone Miner. Metab. 17(2):108\u2013112, 1999.","journal-title":"J. Bone Miner. Metab."},{"key":"864_CR52","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/0021-9290(94)00156-1","volume":"29","author":"CA Pattin","year":"1996","unstructured":"Pattin, C. A., W. E. Caler, and D. R. Carter. Cyclic mechanical property degradation during fatigue loading of cortical bone. J. Biomech. 29:69\u201379, 1996.","journal-title":"J. Biomech."},{"key":"864_CR53","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.medengphy.2005.06.003","volume":"28","author":"L Peng","year":"2006","unstructured":"Peng, L., J. Bai, X. Zeng, and Y. Zhou. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions. Med. Eng. Phys. 28:227\u2013233, 2006.","journal-title":"Med. Eng. Phys."},{"key":"864_CR54","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1359\/jbmr.1997.12.1.24","volume":"12","author":"NF Ray","year":"1997","unstructured":"Ray, N. F., J. K. Chan, M. Thamer, and L. J. Melton. Medical Expenditures for Treatment of Osteoporosis Fractures in the United States in 1995: report From the National Osteoporosis Foundation. J. Bone Miner. Res. 12:24\u201325, 1997.","journal-title":"J. Bone Miner. Res."},{"key":"864_CR55","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/0021-9290(75)90075-5","volume":"8","author":"DT Reilly","year":"1975","unstructured":"Reilly, D. T., and A. H. Burstein. The elastic and ultimate properties of compact bone tissue. J. Biomech. 8:393\u2013405, 1975.","journal-title":"J. Biomech."},{"issue":"7","key":"864_CR56","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/j.medengphy.2011.10.008","volume":"34","author":"T San Antonio","year":"2012","unstructured":"San Antonio, T., M. Ciaccia, C. M\u00fcller-Karger, and E. Casanova. Orientation of orthotropic material properties in a femur FE model: a method based on the principal stresses directions. Med. Eng. Phys. 34(7):914\u2013919, 2012.","journal-title":"Med. Eng. Phys."},{"issue":"2","key":"864_CR57","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.jbiomech.2007.09.009","volume":"41","author":"E Schileo","year":"2008","unstructured":"Schileo, E., F. Taddei, L. Cristofolini, and M. Viceconti. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro. J. Biomech. 41(2):356\u2013367, 2008.","journal-title":"J. Biomech."},{"key":"864_CR58","doi-asserted-by":"crossref","first-page":"2982","DOI":"10.1016\/j.jbiomech.2007.02.010","volume":"40","author":"E Schileo","year":"2007","unstructured":"Schileo, E., F. Taddei, A. Malandrino, L. Cristofolini, and M. Viceconti. Subject-specific finite element models can accurately predict strain levels in long bones. J. Biomech. 40:2982\u20132989, 2007.","journal-title":"J. Biomech."},{"key":"864_CR59","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1097\/00003086-199210000-00034","volume":"283","author":"MD Smith","year":"1992","unstructured":"Smith, M. D., D. D. Cody, A. M. Cooperman, S. A. Goldstein, L. S. Matthews, and M. J. Flynn. Proximal femur bone density and its correlation to fracture load and hip screw penetration load. Clin. Orthop. Relat. Res. 283:244\u2013251, 1992.","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"9","key":"864_CR60","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1016\/j.jbiomech.2003.12.034","volume":"37","author":"OS Sobelman","year":"2004","unstructured":"Sobelman, O. S., J. C. Gibeling, S. M. Stover, S. J. Hazelwood, O. C. Yeh, D. R. Shelton, and R. B. Martin. Do microcracks decrease or increase fatigue resistance in cortical bone? J. Biomech. 37(9):1295\u20131303, 2004.","journal-title":"J. Biomech."},{"key":"864_CR61","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0142-1123(02)00165-2","volume":"2","author":"D Taylor","year":"2003","unstructured":"Taylor, D., and T. C. Lee. A crack growth model for the simulation of fatigue in bone. Int. J. Fatigue 2:387\u2013395, 2003.","journal-title":"Int. J. Fatigue"},{"issue":"1","key":"864_CR62","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3166\/ejcm.18.33-41","volume":"18","author":"M Tellache","year":"2009","unstructured":"Tellache, M., M. Pithioux, P. Chabrand, and C. Hochard. Femoral neck fracture prediction by anisotropic yield criteria. Eur. J. Comput. Mech. 18(1):33\u201341, 2009.","journal-title":"Eur. J. Comput. Mech."},{"key":"864_CR63","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.jbiomech.2008.10.039","volume":"42","author":"N Trabelsi","year":"2009","unstructured":"Trabelsi, N., Z. Yosibash, and C. Milgrom. Validation of subject-specific automated p-FE analysis of the proximal femur. J. Biomech. 42:234\u2013241, 2009.","journal-title":"J. Biomech."},{"key":"864_CR64","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1196\/annals.1346.039","volume":"1068","author":"CH Turner","year":"2006","unstructured":"Turner, C. H. Bone strength: current concepts. Ann. N. Y. Acad. Sci. 1068:429\u2013446, 2006.","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"864_CR65","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1016\/j.jbiomech.2006.07.023","volume":"40","author":"A Ural","year":"2007","unstructured":"Ural, A., and D. Vashishth. Anisotropy of age-related toughness loss in human cortical bone: a finite element study. J. Biomech. 40:1606\u20131614, 2007.","journal-title":"J. Biomech."},{"issue":"1","key":"864_CR66","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0021-9290(02)00319-6","volume":"36","author":"D Vashishth","year":"2003","unstructured":"Vashishth, D., E. Tanner, and W. Bonfield. Experimental validation of a microcracking-based toughening mechanism for cortical bone. J. Biomech. 36(1):121\u2013124, 2003.","journal-title":"J. Biomech."},{"key":"864_CR67","doi-asserted-by":"crossref","first-page":"2951","DOI":"10.1016\/j.jbiomech.2005.10.027","volume":"39","author":"E Verhulp","year":"2006","unstructured":"Verhulp, E., B. van Rietbergen, and R. Huiskes. Comparison of micro-level and continuum level voxel models of the proximal femur. J. Biomech. 39:2951\u20132957, 2006.","journal-title":"J. Biomech."},{"key":"864_CR68","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.jbiomech.2011.11.048","volume":"45","author":"M Viceconti","year":"2012","unstructured":"Viceconti, M., F. Taddei, L. Cristofolini, S. Martelli, C. Falcinelli, and E. Schileo. Are spontaneous fractures possible? An example of clinical application for personalised, multiscale neuro-musculo-skeletal modelling. J. Biomech. 45:421\u2013426, 2012.","journal-title":"J. Biomech."},{"key":"864_CR69","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1115\/1.2796045","volume":"118","author":"H Yang","year":"1996","unstructured":"Yang, H., L. Shen, K. Demetropoulos, I. King, P. Kolodziej, S. Levine, and J. Fitzgerald. The relationship between loading conditions and fracture patterns of the proximal femur. J. Biomech. Eng. 118:575\u2013578, 1996.","journal-title":"J. Biomech. Eng."},{"key":"864_CR70","doi-asserted-by":"crossref","first-page":"2707","DOI":"10.1098\/rsta.2010.0074","volume":"368","author":"Z Yosibash","year":"2010","unstructured":"Yosibash, Z., D. Tal, and N. Trabelsi. Inhomogeneous orthotropic material properties high-order finite-element analysis with inhomogeneous orthotropic material properties. Philos. Trans. R. Soc. A 368:2707\u20132723, 2010.","journal-title":"Philos. Trans. R. Soc. A"},{"issue":"4","key":"864_CR71","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1007\/s11837-012-0298-0","volume":"64","author":"EA Zimmermann","year":"2012","unstructured":"Zimmermann, E. A., H. D. Barth, and R. O. Ritchie. The multiscale origins of fracture resistance in human bone and its biological degradation. JOM 64(4):486\u2013493, 2012.","journal-title":"JOM"},{"key":"864_CR72","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1056\/NEJM199606063342307","volume":"334","author":"JD Zuckerman","year":"1996","unstructured":"Zuckerman, J. D. Hip fracture. N. Engl. J. Med. 334:1519\u20131525, 1996.","journal-title":"N. Engl. J. Med."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-013-0864-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10439-013-0864-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-013-0864-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T15:05:49Z","timestamp":1646147149000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10439-013-0864-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,18]]},"references-count":72,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["864"],"URL":"https:\/\/doi.org\/10.1007\/s10439-013-0864-9","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,18]]}}}