{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T15:59:18Z","timestamp":1756310358608,"version":"3.37.3"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T00:00:00Z","timestamp":1456790400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Prince Charles Hospital Foundation","award":["PRO2014-08"],"award-info":[{"award-number":["PRO2014-08"]}]},{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"crossref","award":["APP1079421"],"award-info":[{"award-number":["APP1079421"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2016,9]]},"DOI":"10.1007\/s10439-016-1579-5","type":"journal-article","created":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T15:51:34Z","timestamp":1456847494000},"page":"2674-2682","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation"],"prefix":"10.1007","volume":"44","author":[{"given":"Shaun D.","family":"Gregory","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3583-688X","authenticated-orcid":false,"given":"Michael C.","family":"Stevens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric L.","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jo P.","family":"Pauls","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Kleinheyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John F.","family":"Fraser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,3,1]]},"reference":[{"key":"1579_CR1","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1016\/S0003-4975(03)00461-2","volume":"75","author":"KD Aaronson","year":"2003","unstructured":"Aaronson, K. D., H. Patel, and F. D. Pagani. Patient selection for left ventricular assist device therapy. Ann. Thorac. Surg. 75:S29\u201335, 2003.","journal-title":"Ann. Thorac. Surg."},{"key":"1579_CR2","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1111\/aor.12253","volume":"38","author":"R Amacher","year":"2014","unstructured":"Amacher, R., G. Ochsner, and M. Schmid Daners. Synchronized pulsatile speed control of turbodynamic left ventricular assist devices: review and prospects. Artif. Organs 38:867\u2013875, 2014.","journal-title":"Artif. Organs"},{"key":"1579_CR3","unstructured":"British Society of Echocardiography Education Committee. Echocardiography: Guidelines for valve quantification. edited by British Heart Foundation 2011."},{"key":"1579_CR4","doi-asserted-by":"crossref","first-page":"489","DOI":"10.5301\/ijao.5000102","volume":"35","author":"N Dranishnikov","year":"2012","unstructured":"Dranishnikov, N., A. Stepanenko, E. V. Potapov, M. Dandel, H. Siniawski, A. Mladenow, M. Hubler, O. Grauhan, Y. Weng, T. Krabatsch, R. Hetzer, and M. Kukucka. Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience. Int. J. Artif. Organs 35:489\u2013494, 2012.","journal-title":"Int. J. Artif. Organs"},{"key":"1579_CR5","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/MAT.0b013e3180536694","volume":"53","author":"DJ Farrar","year":"2007","unstructured":"Farrar, D. J., K. Bourque, C. P. Dague, C. J. Cotter, and V. L. Poirier. Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO J. 53:310\u2013315, 2007.","journal-title":"ASAIO J."},{"key":"1579_CR6","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1057\/jos.2009.15","volume":"4","author":"SD Gregory","year":"2010","unstructured":"Gregory, S. D., N. Greatrex, D. Timms, N. Gaddum, M. J. Pearcy, and J. F. Fraser. Simulation and enhancement of a cardiovascular device test rig. J. Simul. 4:34\u201341, 2010.","journal-title":"J. Simul."},{"key":"1579_CR7","doi-asserted-by":"crossref","unstructured":"Gregory S. D., M. Stevens, D. Timms and M. Pearcy. Replication of the Frank-Starling response in a mock circulation loop. Conf Proc IEEE Eng Med Biol Soc 2011, pp. 6825\u20136828.","DOI":"10.1109\/IEMBS.2011.6091683"},{"key":"1579_CR8","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/aor.12143","volume":"37","author":"SD Gregory","year":"2013","unstructured":"Gregory, S. D., M. C. Stevens, E. Wu, J. F. Fraser, and D. Timms. In vitro evaluation of aortic insufficiency with a rotary left ventricular assist device. Artif. Organs 37:802\u2013809, 2013.","journal-title":"Artif. Organs"},{"key":"1579_CR9","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/MAT.0000000000000262","volume":"61","author":"MS Ising","year":"2015","unstructured":"Ising, M. S., M. A. Sobieski, M. S. Slaughter, S. C. Koenig, and G. A. Giridharan. Feasibility of pump speed modulation for restoring vascular pulsatility with rotary blood pumps. ASAIO J. 61:526\u2013532, 2015.","journal-title":"ASAIO J."},{"key":"1579_CR10","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/MAT.0b013e31829ff57d","volume":"59","author":"M Jelenc","year":"2013","unstructured":"Jelenc, M., B. Jelenc, B. Vrtovec, and I. Knezevic. Mitral regurgitation and axial flow left ventricular assist device: a computer simulation study. ASAIO J. 59:405\u2013409, 2013.","journal-title":"ASAIO J."},{"key":"1579_CR11","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.jtcvs.2010.03.006","volume":"140","author":"R John","year":"2010","unstructured":"John, R., K. Liao, F. Kamdar, P. Eckman, A. Boyle, and M. Colvin-Adams. Effects on pre- and posttransplant pulmonary hemodynamics in patients with continuous-flow left ventricular assist devices. J. Thorac. Cardiovasc. Surg. 140:447\u2013452, 2010.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"1579_CR12","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.jtcvs.2013.10.024","volume":"147","author":"R John","year":"2014","unstructured":"John, R., Y. Naka, S. J. Park, C. Sai-Sudhakar, C. Salerno, K. S. Sundareswaran, D. J. Farrar, and C. A. Milano. Impact of concurrent surgical valve procedures in patients receiving continuous-flow devices. J. Thorac. Cardiovasc. Surg. 147:581\u2013589, 2014; (discussion 589).","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"1579_CR13","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.healun.2014.04.010","volume":"33","author":"JK Kirklin","year":"2014","unstructured":"Kirklin, J. K., D. C. Naftel, F. D. Pagani, R. L. Kormos, L. W. Stevenson, E. D. Blume, M. A. Miller, J. Timothy Baldwin, and J. B. Young. Sixth INTERMACS annual report: A 10,000-patient database. J. Heart Lung Transplant. 33:555\u2013564, 2014.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR14","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/j.healun.2013.06.004","volume":"32","author":"S Kitada","year":"2013","unstructured":"Kitada, S., T. S. Kato, S. S. Thomas, S. D. Conwell, C. Russo, M. R. Di Tullio, M. Farr, P. C. Schulze, N. Uriel, U. P. Jorde, H. Takayama, Y. Naka, S. Homma, and D. M. Mancini. Pre-operative echocardiographic features associated with persistent mitral regurgitation after left ventricular assist device implantation. J. Heart Lung Transplant. 32:897\u2013904, 2013.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR15","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1067\/mhj.2002.123575","volume":"144","author":"TM Koelling","year":"2002","unstructured":"Koelling, T. M., K. D. Aaronson, R. J. Cody, D. S. Bach, and W. F. Armstrong. Prognostic significance of mitral regurgitation and tricuspid regurgitation in patients with left ventricular systolic dysfunction. Am. Heart J. 144:524\u2013529, 2002.","journal-title":"Am. Heart J."},{"key":"1579_CR16","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1097\/MAT.0b013e31826e4267","volume":"58","author":"JA Morgan","year":"2012","unstructured":"Morgan, J. A., R. J. Brewer, H. W. Nemeh, R. Murthy, C. T. Williams, D. E. Lanfear, C. Tita, and G. Paone. Left ventricular reverse remodeling with a continuous flow left ventricular assist device measured by left ventricular end-diastolic dimensions and severity of mitral regurgitation. ASAIO J. 58:574\u2013577, 2012.","journal-title":"ASAIO J."},{"key":"1579_CR17","first-page":"84","volume":"6","author":"KS Parikh","year":"2013","unstructured":"Parikh, K. S., A. K. Mehrotra, M. J. Russo, R. M. Lang, A. Anderson, V. Jeevanandam, B. H. Freed, J. D. Paul, J. Karol, S. Nathan, and A. P. Shah. Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics. JACC: Cardiovasc. Interv. 6:84\u201389, 2013.","journal-title":"JACC: Cardiovasc. Interv."},{"key":"1579_CR18","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.jtcvs.2012.02.015","volume":"144","author":"T Pirbodaghi","year":"2012","unstructured":"Pirbodaghi, T., S. Axiak, A. Weber, T. Gempp, and S. Vandenberghe. Pulsatile control of rotary blood pumps: does the modulation waveform matter? J. Thorac. Cardiovasc. Surg. 144:970\u2013977, 2012.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"12","key":"1579_CR19","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1111\/aor.12323","volume":"38","author":"T Pirbodaghi","year":"2014","unstructured":"Pirbodaghi, T., C. Cotter, and K. Bourque. Power consumption of rotary blood pumps: pulsatile versus constant-speed mode. Artif. Organs 38(12):1024\u20131028, 2014.","journal-title":"Artif. Organs"},{"key":"1579_CR20","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1093\/ejcts\/ezs299","volume":"43","author":"T Pirbodaghi","year":"2013","unstructured":"Pirbodaghi, T., A. Weber, S. Axiak, T. Carrel, and S. Vandenberghe. Asymmetric speed modulation of a rotary blood pump affects ventricular unloading. Eur. J. Cardiothorac. Surg. 43:383\u2013388, 2013.","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"1579_CR21","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.healun.2014.11.008","volume":"34","author":"JO Robertson","year":"2014","unstructured":"Robertson, J. O., D. C. Naftel, S. L. Myers, S. Prasad, G. D. Mertz, A. Itoh, F. D. Pagani, J. K. Kirklin, and S. C. Silvestry. Concomitant aortic valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: an INTERMACS database analysis. J. Heart Lung Transplant. 34:797\u2013805, 2014.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR22","doi-asserted-by":"crossref","first-page":"925310","DOI":"10.1155\/2013\/925310","volume":"2013","author":"MJ Russo","year":"2013","unstructured":"Russo, M. J., A. Merlo, E. M. Johnson, S. Akhter, S. McCarney, J. Steiman, A. Anderson, and V. Jeevanandam. Transapical approach for mitral valve repair during insertion of a left ventricular assist device. Sci. World J. 2013:925310, 2013.","journal-title":"Sci. World J."},{"key":"1579_CR23","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.healun.2010.12.002","volume":"30","author":"D Saeed","year":"2011","unstructured":"Saeed, D., T. Kidambi, S. Shalli, B. Lapin, S. C. Malaisrie, R. Lee, W. G. Cotts, and E. C. McGee, Jr. Tricuspid valve repair with left ventricular assist device implantation: Is it warranted? J. Heart Lung Transplant. 30:530\u2013535, 2011.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR24","doi-asserted-by":"crossref","first-page":"E47","DOI":"10.1111\/j.1525-1594.2010.01168.x","volume":"35","author":"RF Salamonsen","year":"2011","unstructured":"Salamonsen, R. F., D. G. Mason, and P. J. Ayre. Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart. Artif. Organs 35:E47\u201353, 2011.","journal-title":"Artif. Organs"},{"key":"1579_CR25","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","volume":"29","author":"MS Slaughter","year":"2010","unstructured":"Slaughter, M. S., F. D. Pagani, J. G. Rogers, L. W. Miller, B. Sun, S. D. Russel, R. C. Starling, L. Chen, A. J. Boyle, S. Chillcott, R. M. Adamson, M. S. Blood, M. T. Camacho, K. A. Idrissi, M. Petty, M. Sobieski, S. Wright, T. J. Myers, and D. J. Farrar. Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J. Heart Lung Transplant. 29:S1\u2013S39, 2010.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR26","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1007\/s13239-012-0110-x","volume":"3","author":"JR Stanfield","year":"2012","unstructured":"Stanfield, J. R., and C. H. Selzman. Pressure sensitivity of axial-flow and centrifugal-flow left ventricular assist devices. Cardiovasc. Eng. Technol. 3:413\u2013423, 2012.","journal-title":"Cardiovasc. Eng. Technol."},{"key":"1579_CR27","first-page":"630","volume":"3","author":"A Stepanenko","year":"2014","unstructured":"Stepanenko, A., E. V. Potapov, Y. Weng, M. Pasic, T. Krabatsch, and R. Hetzer. Concomitant surgery during ventricular assist device implantation. Ann. Cardiothorac. Surg. 3:630\u2013631, 2014.","journal-title":"Ann. Cardiothorac. Surg."},{"key":"1579_CR28","unstructured":"Stevens M. C. Automatic Control of Dual LVADs as a BiVAD. PhD Thesis, University of Queensland, 2014."},{"key":"1579_CR29","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1016\/j.healun.2014.11.023","volume":"34","author":"JM Stulak","year":"2015","unstructured":"Stulak, J. M., V. Tchantchaleishvili, N. A. Haglund, M. E. Davis, J. A. Schirger, J. A. Cowger, P. Shah, K. D. Aaronson, F. D. Pagani, and S. Maltais. Uncorrected pre-operative mitral valve regurgitation is not associated with adverse outcomes after continuous-flow left ventricular assist device implantation. J. Heart Lung Transplant. 34:718\u2013723, 2015.","journal-title":"J. Heart Lung Transplant."},{"key":"1579_CR30","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1097\/MAT.0b013e31829be026","volume":"59","author":"S Taghavi","year":"2013","unstructured":"Taghavi, S., E. Hamad, L. Wilson, R. Clark, S. N. Jayarajan, N. Uriel, D. J. Goldstein, H. Takayama, Y. Naka, and A. A. Mangi. Mitral valve repair at the time of continuous-flow left ventricular assist device implantation confers meaningful decrement in pulmonary vascular resistance. ASAIO J. 59:469\u2013473, 2013.","journal-title":"ASAIO J."},{"key":"1579_CR31","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1111\/j.1525-1594.2010.01088.x","volume":"35","author":"D Timms","year":"2011","unstructured":"Timms, D., S. Gregory, N. Greatrex, M. J. Pearcy, J. F. Fraser, and U. Steinseifer. A compact mock circulation loop for the in vitro testing of cardiovascular devices. Artif. Organs 35:384\u2013391, 2011.","journal-title":"Artif. Organs"},{"key":"1579_CR32","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1111\/j.1525-1594.2010.01093.x","volume":"34","author":"D Timms","year":"2010","unstructured":"Timms, D., S. Gregory, P. L. Hsu, B. Thomson, M. Pearcy, K. McNeil, J. Fraser, and U. Steinseifer. Atrial versus ventricular cannulation for a rotary ventricular assist device. Artif. Organs 34:714\u2013720, 2010.","journal-title":"Artif. Organs"},{"key":"1579_CR33","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/01.MAT.0000155708.75802.C7","volume":"51","author":"E Tuzun","year":"2005","unstructured":"Tuzun, E., I. D. Gregoric, J. L. Conger, K. Golden, R. Jarvik, O. H. Frazier, and K. A. Kadipasaoglu. The effect of intermittent low speed mode upon aortic valve opening in calves supported with a Jarvik 2000 axial flow device. ASAIO J. 51:139\u2013143, 2005.","journal-title":"ASAIO J."},{"key":"1579_CR34","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1161\/CIRCHEARTFAILURE.113.000473","volume":"7","author":"TS Wang","year":"2014","unstructured":"Wang, T. S., A. F. Hernandez, G. M. Felker, C. A. Milano, J. G. Rogers, and C. B. Patel. Valvular heart disease in patients supported with left ventricular assist devices. Circ. Heart Fail. 7:215\u2013222, 2014.","journal-title":"Circ. Heart Fail."},{"key":"1579_CR35","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.ejcts.2011.06.019","volume":"41","author":"S Westaby","year":"2012","unstructured":"Westaby, S. Tricuspid regurgitation in left ventricular assist device patients. Eur. J. Cardio-Thorac. Surg. 41:217\u2013218, 2012.","journal-title":"Eur. J. Cardio-Thorac. Surg."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-016-1579-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10439-016-1579-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-016-1579-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,14]],"date-time":"2024-06-14T18:16:55Z","timestamp":1718389015000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10439-016-1579-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,1]]},"references-count":35,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["1579"],"URL":"https:\/\/doi.org\/10.1007\/s10439-016-1579-5","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"type":"print","value":"0090-6964"},{"type":"electronic","value":"1573-9686"}],"subject":[],"published":{"date-parts":[[2016,3,1]]}}}