{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T12:46:45Z","timestamp":1775825205366,"version":"3.50.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2018,4,19]],"date-time":"2018-04-19T00:00:00Z","timestamp":1524096000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1007\/s10439-018-2025-7","type":"journal-article","created":{"date-parts":[[2018,4,19]],"date-time":"2018-04-19T14:30:44Z","timestamp":1524148244000},"page":"1558-1567","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["A New Venous Entry Detection Method Based on Electrical Bio-impedance Sensing"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4267-6928","authenticated-orcid":false,"given":"Zhuoqi","family":"Cheng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian L.","family":"Davies","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Darwin G.","family":"Caldwell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonardo S.","family":"Mattos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,4,19]]},"reference":[{"key":"2025_CR1","unstructured":"Ad5933 datasheet document (2013). http:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/AD5933.pdf"},{"key":"2025_CR2","unstructured":"Andreuccetti, D., Fossi, R., Petrucci, C. An internet resource for the calculation of the dielectric properties of body tissues in the frequency range 10 hz-100 ghz. Internet document, 1997."},{"key":"2025_CR3","unstructured":"Brewer, R.: Improving peripheral iv catheterization through robotics: From simple assistive devices to a fully-autonomous system. Doctor of Philosophy, Stanford University (2015)."},{"issue":"01","key":"2025_CR4","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1142\/S2339547813500064","volume":"1","author":"A Chen","year":"2013","unstructured":"Chen, A., Nikitczuk, K., Nikitczuk, J., Maguire, T., Yarmush, M.: Portable robot for autonomous venipuncture using 3d near infrared image guidance. Technology 1(01), 72\u201387 (2013).","journal-title":"Technology"},{"key":"2025_CR5","doi-asserted-by":"crossref","unstructured":"Cheng, Z., Davies, B.L., Caldwell, D.G., Mattos, L.S. A venipuncture detection system for robot-assisted intravenous catheterization. In: 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob), pp. 80\u201386. IEEE, 2016.","DOI":"10.1109\/BIOROB.2016.7523602"},{"issue":"12","key":"2025_CR6","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1177\/0954411917737328","volume":"231","author":"Z Cheng","year":"2017","unstructured":"Cheng, Z., Davies, B.L., Caldwell, D.G., Barresi, G., Xu, Q., Mattos, L.S.: A hand-held robotic device for peripheral intravenous catheterization. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 231(12), 1165\u20131177 (2017).","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"issue":"3","key":"2025_CR7","first-page":"160","volume":"21","author":"AM Frey","year":"1998","unstructured":"Frey, A.M.: Success rates for peripheral iv insertion in a children\u2019s hospital. Journal of Infusion Nursing 21(3), 160\u2013165 (1998).","journal-title":"J. Infus. Nurs."},{"issue":"6","key":"2025_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/cc2880","volume":"8","author":"NA Haas","year":"2004","unstructured":"Haas, N.A.: Clinical review: vascular access for fluid infusion in children. Critical care 8(6), 1 (2004).","journal-title":"Crit. Care"},{"issue":"4","key":"2025_CR9","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1016\/S0022-5347(05)65823-5","volume":"166","author":"DJ Hernandez","year":"2001","unstructured":"Hernandez, D.J., Sinkov, V.A., Roberts, W.W., Allaf, M.E., Patriciu, A., Jarrett, T.W., Kavoussi, L.R., Stoianovici, D.: Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access. The Journal of urology 166(4), 1520\u20131523 (2001).","journal-title":"J. Urol."},{"issue":"5","key":"2025_CR10","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/j.hrtlng.2005.04.002","volume":"34","author":"AF Jacobson","year":"2005","unstructured":"Jacobson, A.F., Winslow, E.H.: Variables influencing intravenous catheter insertion difficulty and failure: an analysis of 339 intravenous catheter insertions. Heart & Lung: The Journal of Acute and Critical Care 34(5), 345\u2013359 (2005).","journal-title":"Heart Lung: J. Acute Crit. Care"},{"key":"2025_CR11","unstructured":"Kalra, A. Iv insertion technique in infants and small children, 2016. https:\/\/www.youtube.com\/watch?v=bu5zgfZFViY ."},{"issue":"2","key":"2025_CR12","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1088\/0967-3334\/30\/2\/002","volume":"30","author":"H Kalv\u00f8y","year":"2009","unstructured":"Kalv\u00f8y, H., Frich, L., Grimnes, S., Martinsen, \u00d8.G., Hol, P.K., Stubhaug, A.: Impedance-based tissue discrimination for needle guidance. Physiological measurement 30(2), 129 (2009).","journal-title":"Physiol. Meas."},{"issue":"6","key":"2025_CR13","doi-asserted-by":"publisher","first-page":"10895","DOI":"10.3390\/s140610895","volume":"14","author":"SF Khalil","year":"2014","unstructured":"Khalil, S.F., Mohktar, M.S., Ibrahim, F.: The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors 14(6), 10895\u201310928 (2014).","journal-title":"Sensors"},{"issue":"5","key":"2025_CR14","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.jen.2009.01.014","volume":"35","author":"LL Kuensting","year":"2009","unstructured":"Kuensting, L.L., DeBoer, S., Holleran, R., Shultz, B.L., Steinmann, R.A., Venella, J.: Difficult venous access in children: taking control. Journal of Emergency Nursing 35(5), 419\u2013424 (2009).","journal-title":"J. Emerg. Nurs."},{"issue":"4","key":"2025_CR15","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1097\/NAN.0b013e3181e3a0a8","volume":"33","author":"P Larsen","year":"2010","unstructured":"Larsen, P., Eldridge, D., Brinkley, J., Newton, D., Goff, D., Hartzog, T., Saad, N.D., Perkin, R.: Pediatric peripheral intravenous access: does nursing experience and competence really make a difference? Journal of Infusion Nursing 33(4), 226\u2013235 (2010).","journal-title":"J. Infus. Nurs."},{"key":"2025_CR16","volume-title":"Bioimpedance and bioelectricity basics","author":"OG Martinsen","year":"2011","unstructured":"Martinsen, O.G., Grimnes, S.: Bioimpedance and bioelectricity basics. Academic Press, (2011)"},{"issue":"1","key":"2025_CR17","first-page":"1","volume":"2","author":"MS Mialich","year":"2014","unstructured":"Mialich, M.S., Sicchieri, J.M.F., Junior, A.A.J.: Analysis of body composition: a critical review of the use of bioelectrical impedance analysis. International Journal of Clinical Nutrition 2(1), 1\u201310 (2014).","journal-title":"Int. J. Clin. Nutr."},{"issue":"2","key":"2025_CR18","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1111\/j.1460-9592.2009.03198.x","volume":"20","author":"OO Nafiu","year":"2010","unstructured":"Nafiu, O.O., Burke, C., Cowan, A., Tutuo, N., Maclean, S., Tremper, K.K.: Comparing peripheral venous access between obese and normal weight children. Pediatric Anesthesia 20(2), 172\u2013176 (2010).","journal-title":"Pediatr. Anesth."},{"issue":"7","key":"2025_CR19","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1309\/EXTW9LBM0CD7P9EV","volume":"36","author":"H Ogden-Grable","year":"2005","unstructured":"Ogden-Grable, H., Gill, G.W.: Phlebotomy puncture juncture: preventing phlebotomy errorspotential for harming your patients. Laboratory Medicine 36(7), 430\u2013433 (2005).","journal-title":"Lab. Med."},{"issue":"12","key":"2025_CR20","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1097\/PEC.0b013e31823ab926","volume":"27","author":"A Riera","year":"2011","unstructured":"Riera, A., Langhan, M., Northrup, V., Santucci, K., Chen, L.: Remember the saphenous: ultrasound evaluation and intravenous site selection of peripheral veins in young children. Pediatric emergency care 27(12), 1121\u20131125 (2011).","journal-title":"Pediatr. Emerg. Care"},{"issue":"2","key":"2025_CR21","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1016\/j.sna.2005.06.012","volume":"125","author":"H Saito","year":"2006","unstructured":"Saito, H., Mitsubayashi, K., Togawa, T.: Detection of needle puncture to blood vessel by using electric conductivity of blood for automatic blood sampling. Sensors and Actuators A: Physical 125(2), 446\u2013450 (2006).","journal-title":"Sens. Actuators A: Phys."},{"key":"2025_CR22","doi-asserted-by":"crossref","unstructured":"Schoevaerdts, L., Esteveny, L., Gijbels, A., Smits, J., Ourak, M., Borghesan, G., Reynaerts, D., Vander\u00a0Poorten, E. Development of a new bio-impedance sensor to detect retinal vessel punctures for retinal vein occlusion treatment. In: Proceedings of the 7th Joint Workshop on New Technologies for Computer\/Robot Assisted Surgery, pp. 55\u201356, 2017.","DOI":"10.1109\/ICRA.2018.8460205"},{"key":"2025_CR23","unstructured":"Shlamovitz, G.Z. Pediatric intravenous cannulation, 2015. http:\/\/emedicine.medscape.com\/article\/2008690-overview ."},{"issue":"5","key":"2025_CR24","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1213\/ane.0b013e318185cdab","volume":"107","author":"E Simhi","year":"2008","unstructured":"Simhi, E., Kachko, L., Bruckheimer, E., Katz, J.: A vein entry indicator device for facilitating peripheral intravenous cannulation in children: a prospective, randomized, controlled trial. Anesthesia & Analgesia 107(5), 1531\u20131535 (2008).","journal-title":"Anesth. Analgesia"},{"issue":"2","key":"2025_CR25","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1109\/TBME.2011.2174990","volume":"59","author":"D Trebbels","year":"2012","unstructured":"Trebbels, D., Fellhauer, F., Jugl, M., Haimerl, G., Min, M., Zengerle, R.: Online tissue discrimination for transcutaneous needle guidance applications using broadband impedance spectroscopy. IEEE Transactions on Biomedical Engineering 59(2), 494\u2013503 (2012).","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"1","key":"2025_CR26","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1213\/ANE.0b013e3182407cd8","volume":"114","author":"CA Troianos","year":"2012","unstructured":"Troianos, C.A., Hartman, G.S., Glas, K.E., Skubas, N.J., Eberhardt, R.T., Walker, J.D., Reeves, S.T., et al.: Guidelines for performing ultrasound guided vascular cannulation: recommendations of the american society of echocardiography and the society of cardiovascular anesthesiologists. Anesthesia & Analgesia 114(1), 46\u201372 (2012).","journal-title":"Anesth. Analgesia"},{"issue":"4","key":"2025_CR27","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1002\/nbm.768","volume":"15","author":"G Vanhoutte","year":"2002","unstructured":"Vanhoutte, G., Verhoye, M., Raman, E., Roberts, M., Linden, A.: In-vivo non-invasive study of the thermoregulatory function of the blood vessels in the rat tail using magnetic resonance angiography. NMR in Biomedicine 15(4), 263\u2013269 (2002).","journal-title":"NMR Biomed."},{"issue":"1","key":"2025_CR28","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1109\/4233.826854","volume":"4","author":"A Zivanovic","year":"2000","unstructured":"yZivanovic, A., Davies, B.L.: A robotic system for blood sampling. IEEE Transactions on Information Technology in Biomedicine 4(1), 8\u201314 (2000).","journal-title":"IEEE Trans. Inf. Technol. Biomed."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10439-018-2025-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-018-2025-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-018-2025-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T19:46:48Z","timestamp":1751572008000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10439-018-2025-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,19]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["2025"],"URL":"https:\/\/doi.org\/10.1007\/s10439-018-2025-7","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,19]]},"assertion":[{"value":"10 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}