{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T22:07:48Z","timestamp":1793138868394,"version":"4.5.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T00:00:00Z","timestamp":1530230400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Engineering and Physical Sciences Research Council (EPSRC) Healthcare Partnership Award","award":["EP\/I027270\/1"],"award-info":[{"award-number":["EP\/I027270\/1"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2018,11]]},"DOI":"10.1007\/s10439-018-2080-0","type":"journal-article","created":{"date-parts":[[2018,6,29]],"date-time":"2018-06-29T16:23:06Z","timestamp":1530289386000},"page":"1736-1744","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Quantitative Comparison of Korotkoff Sound Waveform Characteristics: Effects of Static Cuff Pressures and Stethoscope Positions"],"prefix":"10.1007","volume":"46","author":[{"given":"Fan","family":"Pan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhipeng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dingchang","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,29]]},"reference":[{"key":"2080_CR1","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1088\/0967-3334\/25\/1\/010","volume":"25","author":"J Allen","year":"2004","unstructured":"Allen, J., T. Gehrke, J. J. O\u2019Sullivan, S. T. King, and A. Murray. Characterization of the Korotkoff sounds using joint time-frequency analysis. Physiol. Meas. 25:107\u2013117, 2004.","journal-title":"Physiol. Meas."},{"key":"2080_CR2","doi-asserted-by":"crossref","unstructured":"Babbs C. F. The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements. J. Am. Soc. Hypertens. 9: 935\u2013950 e933, 2015.","DOI":"10.1016\/j.jash.2015.09.011"},{"key":"2080_CR3","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1136\/bmj.322.7293.1043","volume":"322","author":"G Beevers","year":"2001","unstructured":"Beevers, G., G. Y. Lip, and E. O\u2019Brien. ABC of hypertension: blood pressure measurement. Part II-conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ 322:1043\u20131047, 2001.","journal-title":"BMJ"},{"key":"2080_CR4","doi-asserted-by":"publisher","first-page":"4104","DOI":"10.1121\/1.3695401","volume":"131","author":"F Chen","year":"2012","unstructured":"Chen, F., and P. C. Loizou. Contributions of cochlea-scaled entropy and consonant-vowel boundaries to prediction of speech intelligibility in noise. J. Acoust. Soc. Am. 131:4104\u20134113, 2012.","journal-title":"J. Acoust. Soc. Am."},{"key":"2080_CR5","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1152\/ajplegacy.1964.207.1.190","volume":"207","author":"D Chungcharoen","year":"1964","unstructured":"Chungcharoen, D. Genesis of Korotkoff sounds. Am. J. Physiol. 207:190\u2013194, 1964.","journal-title":"Am. J. Physiol."},{"key":"2080_CR6","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1109\/10.247807","volume":"40","author":"RC Cozby","year":"1993","unstructured":"Cozby, R. C., and R. R. Adhami. Low-frequency Korotkoff signal analysis and application. IEEE Trans. Biomed. Eng. 40:1067\u20131070, 1993.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2080_CR7","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1007\/BF02368225","volume":"22","author":"G Drzewiecki","year":"1994","unstructured":"Drzewiecki, G., R. Hood, and H. Apple. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann. Biomed. Eng. 22:88\u201396, 1994.","journal-title":"Ann. Biomed. Eng."},{"key":"2080_CR8","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/BF02368055","volume":"17","author":"GM Drzewiecki","year":"1989","unstructured":"Drzewiecki, G. M., J. Melbin, and A. Noordergraaf. The Korotkoff sound. Ann. Biomed. Eng. 17:325\u2013359, 1989.","journal-title":"Ann. Biomed. Eng."},{"key":"2080_CR9","doi-asserted-by":"publisher","first-page":"Viii","DOI":"10.1007\/978-1-4684-7170-0","volume-title":"Handbook of Blood Pressure Measurement","author":"LA Geddes","year":"1991","unstructured":"Geddes, L. A. Handbook of Blood Pressure Measurement. Clifton, NJ: Humana Press, p. Viii, 1991."},{"key":"2080_CR10","first-page":"57","volume":"5","author":"LA Geddes","year":"1966","unstructured":"Geddes, L. A., H. E. Hoff, and A. S. Badger. Introduction of the auscultatory method of measuring blood pressure\u2013including a translation of Korotkoff\u2019s original paper. Cardiovasc. Res. Cent. Bull. 5:57\u201374, 1966.","journal-title":"Cardiovasc. Res. Cent. Bull."},{"key":"2080_CR11","doi-asserted-by":"publisher","first-page":"51","DOI":"10.7812\/TPP\/09-054","volume":"13","author":"J Handler","year":"2009","unstructured":"Handler, J. The importance of accurate blood pressure measurement. Perm. J. 13:51\u201354, 2009.","journal-title":"Perm. J."},{"key":"2080_CR12","doi-asserted-by":"publisher","first-page":"2224","DOI":"10.1121\/1.1862575","volume":"117","author":"JM Kates","year":"2005","unstructured":"Kates, J. M., and K. H. Arehart. Coherence and the speech intelligibility index. J. Acoust. Soc. Am. 117:2224\u20132237, 2005.","journal-title":"J. Acoust. Soc. Am."},{"key":"2080_CR13","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1146\/annurev.fluid.29.1.399","volume":"29","author":"DN Ku","year":"1997","unstructured":"Ku, D. N. Blood flow in arteries. Annu. Rev. Fluid Mech. 29:399\u2013434, 1997.","journal-title":"Annu. Rev. Fluid Mech."},{"key":"2080_CR14","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1097\/MBP.0000000000000175","volume":"21","author":"C Liu","year":"2016","unstructured":"Liu, C., C. Griffiths, A. Murray, and D. Zheng. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement. Blood Press. Monit. 21:178\u2013183, 2016.","journal-title":"Blood Press Monit."},{"key":"2080_CR15","first-page":"e32","volume":"10","author":"A Nunez","year":"2016","unstructured":"Nunez, A., M. Ihsan, S. Gaballah, A. Haque, O. Yurevich, S. Ahluwalia, L. Salciccioli, M. Stewart, and J. Lazar. Differential effects of hyperemia and passive leg raising on QRS to Korotkoff sound time intervals in hypertensive patients. J. Am. Soc. Hypertens. 10:e32, 2016.","journal-title":"J. Am. Soc. Hyperten."},{"key":"2080_CR16","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1097\/00004872-200305000-00001","volume":"21","author":"E O\u2019Brien","year":"2003","unstructured":"O\u2019Brien, E., R. Asmar, L. Beilin, Y. Imai, J. M. Mallion, G. Mancia, T. Mengden, M. Myers, P. Padfield, P. Palatini, G. Parati, T. Pickering, J. Redon, J. Staessen, G. Stergiou, P. Verdecchia, and M. European. Society of Hypertension Working Group on Blood Pressure. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J. Hypertens. 21:821\u2013848, 2003.","journal-title":"J. Hypertens."},{"key":"2080_CR17","doi-asserted-by":"publisher","first-page":"e301","DOI":"10.1097\/MD.0000000000000301","volume":"93","author":"F Pan","year":"2014","unstructured":"Pan, F., D. C. Zheng, P. Y. He, and A. Murray. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements an observational study. Medicine 93:e301, 2014.","journal-title":"Medicine"},{"key":"2080_CR18","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1161\/01.HYP.0000150859.47929.8e","volume":"45","author":"TG Pickering","year":"2005","unstructured":"Pickering, T. G., J. E. Hall, L. J. Appel, B. E. Falkner, J. Graves, M. N. Hill, D. W. Jones, T. Kurtz, S. G. Sheps, E. J. Roccella, and P. Subcommittee of and R. Public Education of the American Heart Association Council on High Blood Pressure. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension 45:142\u2013161, 2005.","journal-title":"Hypertension"},{"key":"2080_CR19","doi-asserted-by":"crossref","unstructured":"Rauterkus T., J. F. Feltz and J. W. Fickes. Frequency analysis of Korotkov blood pressure sounds using the Fourier transform. Sam-TR-66-8. Technical report SAM-TR. USAF School of Aerospace Medicine 1\u201346, 1966.","DOI":"10.21236\/AD0632483"},{"key":"2080_CR20","first-page":"467","volume":"52","author":"D Zheng","year":"2014","unstructured":"Zheng, D., L. Y. Di Marco, and A. Murray. Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. Med. Biol. Eng. Comput. 52:467\u2013473, 2014.","journal-title":"Med. Biol. Eng. Comput."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10439-018-2080-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-018-2080-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-018-2080-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,29]],"date-time":"2019-08-29T22:28:15Z","timestamp":1567117695000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10439-018-2080-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,29]]},"references-count":20,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2018,11]]}},"alternative-id":["2080"],"URL":"https:\/\/doi.org\/10.1007\/s10439-018-2080-0","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,29]]},"assertion":[{"value":"15 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}