{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T19:35:36Z","timestamp":1773603336270,"version":"3.50.1"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T00:00:00Z","timestamp":1597276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T00:00:00Z","timestamp":1597276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Tendon mobility is highly relevant in rotator cuff surgery. Objective data about rotator cuff mobility is rare. Tendon mobility still needs to be evaluated subjectively by the surgeon. This study aims to establish a porcine animal model for mobility analysis of the supraspinatus. In this context, we introduce a sensor-enhanced, arthroscopic grasper (SEAG) suitable for objective intraoperative measurements of tendon mobility in clinical praxis. Tendon mobility of 15 fresh porcine cadaver shoulders with artificial rotator cuff tears was evaluated using the SEAG. Mobility characteristics (load\u2013displacement curves, maximum load, stiffness) were studied and inter- and intraobserver agreement (intraclass correlation coefficient (ICC)) were tested. Factors with a potential adverse effect (plastic deformation and rigor mortis) were also evaluated. All shoulders showed characteristic reproducible load\u2013displacement curves with a nonlinear part at the start, followed by a linear part. Mean maximum load was 28.6\u00a0N\u2009\u00b1\u200912.5. Mean stiffness was 6.0\u00a0N\/mm\u2009\u00b1\u20092.6. We found substantial interobserver agreement (ICC 0.672) and nearly perfect intraobserver agreement (0.944) for maximum load measurement. Inter- (0.021) and intraobserver (0.774) agreement for stiffness was lower. Plastic deformation and rigor mortis were excluded. The animal model demonstrates reliable and <jats:italic>in vivo<\/jats:italic>-like measurements of tendon mobility. The SEAG is a reliable tool for tendon mobility assessment.<\/jats:p>","DOI":"10.1007\/s10439-020-02572-3","type":"journal-article","created":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T15:49:59Z","timestamp":1597333799000},"page":"617-626","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Mobility Assessment of the Supraspinatus in a Porcine Cadaver Model Using a Sensor-Enhanced, Arthroscopic Grasper"],"prefix":"10.1007","volume":"49","author":[{"given":"Felix","family":"Porschke","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Luecke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thorsten","family":"Guehring","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christel","family":"Weiss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Studier-Fischer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul Alfred","family":"Gruetzner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc","family":"Schnetzke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,13]]},"reference":[{"key":"2572_CR1","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1023\/B:ABME.0000007801.44277.df","volume":"32","author":"SS Burkhart","year":"2004","unstructured":"Burkhart, S. S. The principle of margin convergence in rotator cuff repair as a means of strain reduction at the tear margin. Ann. Biomed. Eng. 32:166\u2013170, 2004.","journal-title":"Ann. Biomed. Eng."},{"key":"2572_CR2","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1097\/BOT.0b013e318225b875","volume":"25","author":"JL Cartner","year":"2011","unstructured":"Cartner, J. L., Z. M. Hartsell, W. M. Ricci, and P. Tornetta, 3rd. Can we trust ex vivo mechanical testing of fresh\u2013frozen cadaveric specimens? The effect of postfreezing delays. J. Orthop. Trauma 25:459\u2013461, 2011.","journal-title":"J. Orthop. Trauma"},{"key":"2572_CR3","doi-asserted-by":"publisher","first-page":"3180","DOI":"10.1007\/s00167-019-05346-0","volume":"27","author":"Y Chen","year":"2019","unstructured":"Chen, Y., H. Li, Y. Qiao, Y. Ge, Y. Li, Y. Hua, J. Chen, and S. Chen. Double-row rotator cuff repairs lead to more intensive pain during the early postoperative period but have a lower risk of residual pain than single-row repairs. Knee Surg. Sports Traumatol. Arthrosc. 27:3180\u20133187, 2019.","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"2572_CR4","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1067\/mse.2000.109385","volume":"9","author":"PA Davidson","year":"2000","unstructured":"Davidson, P. A., and D. W. Rivenburgh. Rotator cuff repair tension as a determinant of functional outcome. J. Shoulder Elbow Surg. 9:502\u2013506, 2000.","journal-title":"J. Shoulder Elbow Surg."},{"issue":"Suppl 4","key":"2572_CR5","doi-asserted-by":"publisher","first-page":"35","DOI":"10.2106\/JBJS.H.00650","volume":"90","author":"BG Domb","year":"2008","unstructured":"Domb, B. G., R. E. Glousman, A. Brooks, M. Hansen, T. Q. Lee, and N. S. ElAttrache. High-tension double-row footprint repair compared with reduced-tension single-row repair for massive rotator cuff tears. J. Bone Joint Surg. Am. 90(Suppl 4):35\u201339, 2008.","journal-title":"J. Bone Joint Surg. Am."},{"key":"2572_CR6","first-page":"150","volume":"11","author":"L Edelstein","year":"2011","unstructured":"Edelstein, L., S. J. Thomas, and L. J. Soslowsky. Rotator cuff tears: what have we learned from animal models? J. Musculoskelet. Neuronal Interact. 11:150\u2013162, 2011.","journal-title":"J. Musculoskelet. Neuronal Interact."},{"key":"2572_CR7","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.aanat.2011.03.007","volume":"193","author":"G Fessel","year":"2011","unstructured":"Fessel, G., K. Frey, A. Schweizer, M. Calcagni, O. Ullrich, and J. G. Snedeker. Suitability of Thiel embalmed tendons for biomechanical investigation. Ann. Anat. 193:237\u2013241, 2011.","journal-title":"Ann. Anat."},{"key":"2572_CR8","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1097\/01.blo.0000136831.17696.80","volume":"426","author":"JA Gimbel","year":"2004","unstructured":"Gimbel, J. A., S. Mehta, J. P. Van Kleunen, G. R. Williams, and L. J. Soslowsky. The tension required at repair to reappose the supraspinatus tendon to bone rapidly increases after injury. Clin Orthop Relat Res 426:258\u2013265, 2004.","journal-title":"Clin Orthop Relat Res"},{"key":"2572_CR9","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.jbiomech.2003.09.019","volume":"37","author":"JA Gimbel","year":"2004","unstructured":"Gimbel, J. A., J. P. Van Kleunen, S. Mehta, S. M. Perry, G. R. Williams, and L. J. Soslowsky. Supraspinatus tendon organizational and mechanical properties in a chronic rotator cuff tear animal model. J. Biomech. 37:739\u2013749, 2004.","journal-title":"J. Biomech."},{"key":"2572_CR10","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/S0268-0033(99)00095-9","volume":"15","author":"A Halder","year":"2000","unstructured":"Halder, A., M. E. Zobitz, F. Schultz, and K. N. An. Mechanical properties of the posterior rotator cuff. Clin Biomech (Bristol, Avon) 15:456\u2013462, 2000.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"2572_CR11","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1007\/s00590-017-2114-6","volume":"28","author":"E Hohmann","year":"2018","unstructured":"Hohmann, E., A. Konig, C. J. Kat, V. Glatt, K. Tetsworth, and N. Keough. Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies. Eur. J. Orthop. Surg. Traumatol. 28:859\u2013868, 2018.","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"2572_CR12","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1002\/jor.1100130413","volume":"13","author":"E Itoi","year":"1995","unstructured":"Itoi, E., L. J. Berglund, J. J. Grabowski, F. M. Schultz, E. S. Growney, B. F. Morrey, and K. N. An. Tensile properties of the supraspinatus tendon. J. Orthop. Res. 13:578\u2013584, 1995.","journal-title":"J. Orthop. Res."},{"key":"2572_CR13","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.arthro.2017.07.022","volume":"34","author":"J Kawakami","year":"2018","unstructured":"Kawakami, J., N. Yamamoto, H. Nagamoto, and E. Itoi. Minimum distance of suture anchors used for rotator cuff repair without decreasing the pullout strength: a biomechanical study. Arthroscopy 34:377\u2013385, 2018.","journal-title":"Arthroscopy"},{"key":"2572_CR14","doi-asserted-by":"publisher","first-page":"2401","DOI":"10.1177\/0363546515596408","volume":"43","author":"ML Killian","year":"2015","unstructured":"Killian, M. L., L. M. Cavinatto, S. R. Ward, N. Havlioglu, S. Thomopoulos, and L. M. Galatz. Chronic degeneration leads to poor healing of repaired massive rotator cuff tears in rats. Am. J. Sports Med. 43:2401\u20132410, 2015.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR15","doi-asserted-by":"publisher","first-page":"2606","DOI":"10.1177\/0363546514547177","volume":"42","author":"JH Kim","year":"2014","unstructured":"Kim, J. H., I. T. Hong, K. J. Ryu, S. T. Bong, Y. S. Lee, and J. H. Kim. Retear rate in the late postoperative period after arthroscopic rotator cuff repair. Am. J. Sports Med. 42:2606\u20132613, 2014.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR16","doi-asserted-by":"publisher","first-page":"2807","DOI":"10.1177\/0363546516651831","volume":"44","author":"DH Kim","year":"2016","unstructured":"Kim, D. H., Y. H. Jang, Y. E. Choi, H. R. Lee, and S. H. Kim. Evaluation of repair tension in arthroscopic rotator cuff repair: does it really matter to the integrity of the rotator cuff? Am. J. Sports Med. 44:2807\u20132812, 2016.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR17","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1016\/j.jse.2017.11.016","volume":"27","author":"YK Kim","year":"2018","unstructured":"Kim, Y. K., K. H. Jung, J. W. Kim, U. S. Kim, and D. H. Hwang. Factors affecting rotator cuff integrity after arthroscopic repair for medium-sized or larger cuff tears: a retrospective cohort study. J. Shoulder Elbow Surg. 27:1012\u20131020, 2018.","journal-title":"J. Shoulder Elbow Surg."},{"key":"2572_CR18","doi-asserted-by":"publisher","first-page":"1482","DOI":"10.2106\/JBJS.L.01193","volume":"95","author":"SJ Kim","year":"2013","unstructured":"Kim, S. J., S. H. Kim, S. K. Lee, J. W. Seo, and Y. M. Chun. Arthroscopic repair of massive contracted rotator cuff tears: aggressive release with anterior and posterior interval slides do not improve cuff healing and integrity. J. Bone Joint Surg. Am. 95:1482\u20131488, 2013.","journal-title":"J. Bone Joint Surg. Am."},{"key":"2572_CR19","doi-asserted-by":"publisher","first-page":"2270","DOI":"10.1177\/0363546513499000","volume":"41","author":"YK Kim","year":"2013","unstructured":"Kim, Y. K., S. H. Moon, and S. H. Cho. Treatment outcomes of single- versus double-row repair for larger than medium-sized rotator cuff tears: the effect of preoperative remnant tendon length. Am. J. Sports Med. 41:2270\u20132277, 2013.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR20","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.jse.2011.01.038","volume":"21","author":"A Ladermann","year":"2012","unstructured":"Ladermann, A., F. K. Christophe, P. J. Denard, and G. Walch. Supraspinatus rupture at the musclotendinous junction: an uncommonly recognized phenomenon. J. Shoulder Elbow Surg. 21:72\u201376, 2012.","journal-title":"J. Shoulder Elbow Surg."},{"key":"2572_CR21","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1002\/jor.20938","volume":"27","author":"SP Lake","year":"2009","unstructured":"Lake, S. P., K. S. Miller, D. M. Elliott, and L. J. Soslowsky. Effect of fiber distribution and realignment on the nonlinear and inhomogeneous mechanical properties of human supraspinatus tendon under longitudinal tensile loading. J. Orthop. Res. 27:1596\u20131602, 2009.","journal-title":"J. Orthop. Res."},{"key":"2572_CR22","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.jbiomech.2009.10.017","volume":"43","author":"SP Lake","year":"2010","unstructured":"Lake, S. P., K. S. Miller, D. M. Elliott, and L. J. Soslowsky. Tensile properties and fiber alignment of human supraspinatus tendon in the transverse direction demonstrate inhomogeneity, nonlinearity, and regional isotropy. J. Biomech. 43:727\u2013732, 2010.","journal-title":"J. Biomech."},{"key":"2572_CR23","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis, J. R., and G. G. Koch. The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174, 1977.","journal-title":"Biometrics"},{"key":"2572_CR24","doi-asserted-by":"publisher","first-page":"2298","DOI":"10.1016\/j.arthro.2018.03.015","volume":"34","author":"KW Lee","year":"2018","unstructured":"Lee, K. W., K. H. Moon, C. H. Ma, G. S. Lee, D. S. Yang, and W. S. Choy. Clinical and radiologic outcomes after medializing and not medializing rotator cuff tendon attachment site on chronic retracted rotator cuff tears. Arthroscopy 34:2298\u20132307, 2018.","journal-title":"Arthroscopy"},{"key":"2572_CR25","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.arthro.2003.11.013","volume":"20","author":"IK Lo","year":"2004","unstructured":"Lo, I. K., and S. S. Burkhart. Arthroscopic repair of massive, contracted, immobile rotator cuff tears using single and double interval slides: technique and preliminary results. Arthroscopy 20:22\u201333, 2004.","journal-title":"Arthroscopy"},{"key":"2572_CR26","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.1016\/j.jse.2015.06.005","volume":"24","author":"M Loew","year":"2015","unstructured":"Loew, M., P. Magosch, S. Lichtenberg, P. Habermeyer, and F. Porschke. How to discriminate between acute traumatic and chronic degenerative rotator cuff lesions: an analysis of specific criteria on radiography and magnetic resonance imaging. J. Shoulder Elbow Surg. 24:1685\u20131693, 2015.","journal-title":"J. Shoulder Elbow Surg."},{"key":"2572_CR27","doi-asserted-by":"publisher","first-page":"1914","DOI":"10.1007\/s10439-011-0301-x","volume":"39","author":"S Mannava","year":"2011","unstructured":"Mannava, S., W. F. Wiggins, K. R. Saul, J. D. Stitzel, B. P. Smith, L. A. Koman, T. L. Smith, and C. J. Tuohy. Contributions of neural tone to in vivo passive muscle\u2013tendon unit biomechanical properties in a rat rotator cuff animal model. Ann. Biomed. Eng. 39:1914\u20131924, 2011.","journal-title":"Ann. Biomed. Eng."},{"key":"2572_CR28","doi-asserted-by":"publisher","first-page":"2242","DOI":"10.1177\/0363546512457587","volume":"40","author":"DC Meyer","year":"2012","unstructured":"Meyer, D. C., K. Wieser, M. Farshad, and C. Gerber. Retraction of supraspinatus muscle and tendon as predictors of success of rotator cuff repair. Am. J. Sports Med. 40:2242\u20132247, 2012.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR29","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1177\/0363546510388152","volume":"39","author":"T Mihata","year":"2011","unstructured":"Mihata, T., T. Fukuhara, B. J. Jun, C. Watanabe, and M. Kinoshita. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique. Am. J. Sports Med. 39:551\u2013556, 2011.","journal-title":"Am. J. Sports Med."},{"key":"2572_CR30","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1007\/s10439-011-0490-3","volume":"40","author":"KS Miller","year":"2012","unstructured":"Miller, K. S., B. K. Connizzo, and L. J. Soslowsky. Collagen fiber re-alignment in a neonatal developmental mouse supraspinatus tendon model. Ann. Biomed. Eng. 40:1102\u20131110, 2012.","journal-title":"Ann. Biomed. Eng."},{"key":"2572_CR31","doi-asserted-by":"publisher","first-page":"2992","DOI":"10.1016\/j.arthro.2019.05.049","volume":"35","author":"SG Park","year":"2019","unstructured":"Park, S. G., B. J. Shim, and H. G. Seok. How much will high tension adversely affect rotator cuff repair integrity? Arthroscopy 35:2992\u20133000, 2019.","journal-title":"Arthroscopy"},{"key":"2572_CR32","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1007\/s00402-017-2823-7","volume":"138","author":"MF Pastor","year":"2018","unstructured":"Pastor, M. F., M. Kraemer, M. Schwarze, C. Hurschler, T. Smith, and M. Wellmann. The effect of rotator cuff malreduction on tendon tension: an evaluation of a custom-made digital tensiometer clamp. Arch. Orthop. Trauma Surg. 138:219\u2013225, 2018.","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"2572_CR33","first-page":"81","volume":"254","author":"D Patte","year":"1990","unstructured":"Patte, D. Classification of rotator cuff lesions. Clin. Orthop. Relat. Res. 254:81\u201386, 1990.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"2572_CR34","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1186\/s13018-017-0643-7","volume":"12","author":"H Shimokobe","year":"2017","unstructured":"Shimokobe, H., M. Gotoh, H. Honda, H. Nakamura, Y. Mitsui, T. Kakuma, T. Okawa, and N. Shiba. Risk factors for retear of large\/massive rotator cuff tears after arthroscopic surgery: an analysis of tearing patterns. J. Orthop. Surg. Res. 12:140, 2017.","journal-title":"J. Orthop. Surg. Res."},{"key":"2572_CR35","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/S1058-2746(96)80070-X","volume":"5","author":"LJ Soslowsky","year":"1996","unstructured":"Soslowsky, L. J., J. E. Carpenter, C. M. DeBano, I. Banerji, and M. R. Moalli. Development and use of an animal model for investigations on rotator cuff disease. J. Shoulder Elbow Surg. 5:383\u2013392, 1996.","journal-title":"J. Shoulder Elbow Surg."},{"key":"2572_CR36","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1053\/ar.1999.v15.0150521","volume":"15","author":"JC Tauro","year":"1999","unstructured":"Tauro, J. C. Arthroscopic, \u201cinterval slide\u201d in the repair of large rotator cuff tears. Arthroscopy 15:527\u2013530, 1999.","journal-title":"Arthroscopy"},{"key":"2572_CR37","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1097\/00003086-199711000-00027","volume":"344","author":"H Thomazeau","year":"1997","unstructured":"Thomazeau, H., E. Boukobza, N. Morcet, J. Chaperon, and F. Langlais. Prediction of rotator cuff repair results by magnetic resonance imaging. Clin. Orthop. Relat. Res. 344:275\u2013283, 1997.","journal-title":"Clin. Orthop. Relat. Res."},{"key":"2572_CR38","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1115\/1.429621","volume":"122","author":"CA Van Ee","year":"2000","unstructured":"Van Ee, C. A., A. L. Chasse, and B. S. Myers. Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage. J. Biomech. Eng. 122:9\u201314, 2000.","journal-title":"J. Biomech. Eng."},{"key":"2572_CR39","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1016\/j.jmbbm.2017.04.009","volume":"71","author":"F Vollner","year":"2017","unstructured":"Vollner, F., U. Pilsl, B. Craiovan, F. Zeman, M. Schneider, M. Worner, J. Grifka, and M. Weber. Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee. J. Mech. Behav. Biomed. Mater. 71:392\u2013396, 2017.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"2572_CR40","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1177\/0363546516652900","volume":"45","author":"J Yang","year":"2017","unstructured":"Yang, J., M. Robbins, J. Reilly, T. Maerz, and K. Anderson. The clinical effect of a rotator cuff retear: a meta-analysis of arthroscopic single-row and double-row repairs. Am. J. Sports Med. 45:733\u2013741, 2017.","journal-title":"Am. J. Sports Med."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-020-02572-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-020-02572-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-020-02572-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T01:15:13Z","timestamp":1628817313000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10439-020-02572-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,13]]},"references-count":40,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2572"],"URL":"https:\/\/doi.org\/10.1007\/s10439-020-02572-3","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,13]]},"assertion":[{"value":"18 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}