{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T03:51:32Z","timestamp":1776484292959,"version":"3.51.2"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,9,8]],"date-time":"2020-09-08T00:00:00Z","timestamp":1599523200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,8]],"date-time":"2020-09-08T00:00:00Z","timestamp":1599523200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Heart failure is a raising cause of mortality. Heart transplantation and ventricular assist device (VAD) support represent the only available lifelines for end stage disease. In the context of donor organ shortage, the future role of VAD as destination therapy is emerging. Yet, major drawbacks are connected to the long-term implantation of current devices. Poor VAD hemocompatibility exposes the patient to life-threatening events, including haemorrhagic syndromes and thrombosis. Here, we introduce a new concept of artificial support, the Hybrid Membrane VAD, as a first-of-its-kind pump prototype enabling physiological blood propulsion through the cyclic actuation of a hyperelastic membrane, enabling the protection from the thrombogenic interaction between blood and the implant materials. The centre of the luminal membrane surface displays a rationally-developed surface topography interfering with flow to support a living endothelium. The precast cell layer survives to a range of dynamically changing pump actuating conditions i.e., actuation frequency from 1 to 4\u00a0Hz, stroke volume from 12 to 30\u00a0mL, and support duration up to 313\u00a0min, which are tested both <jats:italic>in vitro<\/jats:italic> and <jats:italic>in vivo<\/jats:italic>, ensuring the full retention of tissue integrity and connectivity under challenging conditions. In summary, the presented results constitute a proof of principle for the Hybrid Membrane VAD concept and represent the basis for its future development towards clinical validation.<\/jats:p>","DOI":"10.1007\/s10439-020-02590-1","type":"journal-article","created":{"date-parts":[[2020,9,10]],"date-time":"2020-09-10T08:09:51Z","timestamp":1599725391000},"page":"716-731","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["A Novel Hybrid Membrane VAD as First Step Toward Hemocompatible Blood Propulsion"],"prefix":"10.1007","volume":"49","author":[{"given":"Aldo","family":"Ferrari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Costanza","family":"Giampietro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bj\u00f6rn","family":"Bachmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Bernardi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Deon","family":"Bezuidenhhout","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Ermanni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raoul","family":"Hopf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Kitz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerald","family":"Kress","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Loosli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vita","family":"Marina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mirko","family":"Meboldt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Pellegrini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dimos","family":"Poulikakos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathias","family":"Rebholz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6411-8871","authenticated-orcid":false,"given":"Marianne","family":"Schmid Daners","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tanja","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Starck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georgios","family":"Stefopoulos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"S\u00fcndermann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bente","family":"Thamsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Zilla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evgenij","family":"Potapov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Volkmar","family":"Falk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edoardo","family":"Mazza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,8]]},"reference":[{"key":"2590_CR1","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1080\/10255842.2015.1015527","volume":"19","author":"MG Al-Azawy","year":"2016","unstructured":"Al-Azawy, M. G., A. Turan, and A. Revell. Assessment of turbulence models for pulsatile flow inside a heart pump. Comput. Methods Biomech. Biomed. Eng. 19:271\u2013285, 2016.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2590_CR2","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1161\/CIRCHEARTFAILURE.110.959684","volume":"4","author":"AV Ambardekar","year":"2011","unstructured":"Ambardekar, A. V., and P. M. Buttrick. Reverse remodeling with left ventricular assist devices: a review of clinical, cellular, and molecular effects. Circ. Heart Fail. 4:224\u2013233, 2011.","journal-title":"Circ. Heart Fail."},{"key":"2590_CR3","doi-asserted-by":"publisher","first-page":"38861","DOI":"10.1038\/srep38861","volume":"6","author":"BJ Bachmann","year":"2016","unstructured":"Bachmann, B. J., L. Bernardi, C. Loosli, J. Marschewski, M. Perrini, et al. A novel bioreactor system for the assessment of endothelialization on deformable surfaces. Sci. Rep. 6:38861, 2016.","journal-title":"Sci. Rep."},{"key":"2590_CR4","doi-asserted-by":"publisher","first-page":"2726","DOI":"10.1039\/C8BM00660A","volume":"6","author":"BJ Bachmann","year":"2018","unstructured":"Bachmann, B. J., C. Giampietro, A. Bayram, G. Stefopoulos, C. Michos, et al. Honeycomb-structured metasurfaces for the adaptive nesting of endothelial cells under hemodynamic loads. Biomater. Sci. 6:2726\u20132737, 2018.","journal-title":"Biomater. Sci."},{"key":"2590_CR5","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.1016\/j.jacc.2018.02.074","volume":"71","author":"JJ Badimon","year":"2018","unstructured":"Badimon, J. J., and C. G. Santos-Gallego. Modulatory role of pulsatility on von Willebrand factor: implications for mechanical circulatory support-associated bleeding. J. Am. Coll. Cardiol. 71:2119\u20132121, 2018.","journal-title":"J. Am. Coll. Cardiol."},{"key":"2590_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10456-012-9307-8","volume":"16","author":"S Baiguera","year":"2013","unstructured":"Baiguera, S., and D. Ribatti. Endothelialization approaches for viable engineered tissues. Angiogenesis 16:1\u201314, 2013.","journal-title":"Angiogenesis"},{"key":"2590_CR7","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1016\/j.jtcvs.2013.08.043","volume":"147","author":"CR Bartoli","year":"2014","unstructured":"Bartoli, C. R., S. Dassanayaka, K. R. Brittian, A. Luckett, S. Sithu, et al. Insights into the mechanism(s) of von Willebrand factor degradation during mechanical circulatory support. J. Thorac. Cardiovasc. Surg. 147:1634\u20131643, 2014.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"2590_CR8","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1016\/j.jtcvs.2014.09.031","volume":"149","author":"CR Bartoli","year":"2015","unstructured":"Bartoli, C. R., D. J. Restle, D. M. Zhang, M. A. Acker, and P. Atluri. Pathologic von Willebrand factor degradation with a left ventricular assist device occurs via two distinct mechanisms: mechanical demolition and enzymatic cleavage. J. Thorac. Cardiovasc. Surg. 149:281\u2013289, 2015.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"2590_CR9","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1152\/physrev.00035.2003","volume":"84","author":"G Bazzoni","year":"2004","unstructured":"Bazzoni, G., and E. Dejana. Endothelial cell-to-cell junctions: molecular organization and role in vascular homeostasis. Physiol. Rev. 84:869\u2013901, 2004.","journal-title":"Physiol. Rev."},{"key":"2590_CR10","doi-asserted-by":"publisher","first-page":"204173141773154","DOI":"10.1177\/2041731417731546","volume":"8","author":"TM Bedair","year":"2017","unstructured":"Bedair, T. M., M. A. ElNaggar, Y. K. Joung, and D. K. Han. Recent advances to accelerate re-endothelialization for vascular stents. J. Tissue Eng. 8:2041731417731546, 2017.","journal-title":"J. Tissue Eng."},{"key":"2590_CR11","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.polymertesting.2016.12.029","volume":"58","author":"L Bernardi","year":"2017","unstructured":"Bernardi, L., R. Hopf, A. Ferrari, A. E. Ehret, and E. Mazza. On the large strain deformation behavior of silicone-based elastomers for biomedical applications. Polym. Test 58:189\u2013198, 2017.","journal-title":"Polym. Test"},{"key":"2590_CR12","first-page":"418","volume":"33","author":"KA Dasse","year":"1987","unstructured":"Dasse, K. A., S. D. Chipman, C. N. Sherman, A. H. Levine, and O. H. Frazier. Clinical experience with textured blood contacting surfaces in ventricular assist devices. ASAIO Trans. 33:418\u2013425, 1987.","journal-title":"ASAIO Trans."},{"key":"2590_CR13","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s12471-011-0211-4","volume":"20","author":"ML Haeck","year":"2012","unstructured":"Haeck, M. L., G. E. Hoogslag, S. F. Rodrigo, D. E. Atsma, R. J. Klautz, et al. Treatment options in end-stage heart failure: where to go from here? Neth. Heart J. 20:167\u2013175, 2012.","journal-title":"Neth. Heart J."},{"key":"2590_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s13221-015-0033-z","volume":"7","author":"NF Jufri","year":"2015","unstructured":"Jufri, N. F., A. Mohamedali, A. Avolio, and M. S. Baker. Mechanical stretch: physiological and pathological implications for human vascular endothelial cells. Vasc. Cell 7:8, 2015.","journal-title":"Vasc. Cell"},{"key":"2590_CR15","doi-asserted-by":"publisher","first-page":"63","DOI":"10.2174\/1573403X09666131117163825","volume":"11","author":"JN Katz","year":"2015","unstructured":"Katz, J. N., S. B. Waters, I. B. Hollis, and P. P. Chang. Advanced therapies for end-stage heart failure. Curr. Cardiol. Rev. 11:63\u201372, 2015.","journal-title":"Curr. Cardiol. Rev."},{"issue":"Pt 17","key":"2590_CR16","doi-asserted-by":"crossref","first-page":"2065","DOI":"10.1242\/jcs.110.17.2065","volume":"110","author":"MG Lampugnani","year":"1997","unstructured":"Lampugnani, M. G., M. Corada, P. Andriopoulou, S. Esser, W. Risau, and E. Dejana. Cell confluence regulates tyrosine phosphorylation of adherens junction components in endothelial cells. J. Cell Sci. 110(Pt 17):2065\u20132077, 1997.","journal-title":"J. Cell Sci."},{"key":"2590_CR17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.healun.2017.09.002","volume":"37","author":"C Latremouille","year":"2018","unstructured":"Latremouille, C., A. Carpentier, P. Leprince, J. C. Roussel, B. Cholley, et al. A bioprosthetic total artificial heart for end-stage heart failure: results from a pilot study. J. Heart Lung Transplant. 37:33\u201337, 2018.","journal-title":"J. Heart Lung Transplant."},{"key":"2590_CR18","unstructured":"Loosli, C. Numerical and experimental studies for the development of an endothelialized ventricular assist device. ETH dissertation number 26750, 2020."},{"key":"2590_CR19","first-page":"1","volume":"23","author":"C Loosli","year":"2018","unstructured":"Loosli, C., L. Moy, G. Kress, E. Mazza, and P. Ermanni. Corrugated diaphragm shape design study for hemocompatible pulsatile ventricular assist devices. Comput. Methods Biomech. Biomed. Eng. 23:1\u20139, 2018.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2590_CR20","first-page":"241","volume":"37","author":"C Loosli","year":"2019","unstructured":"Loosli, C., S. Rupp, B. Thamsen, M. Rebholz, G. Kress, et al. High-frequency operation of pulsatile ventricular assist devices: a computational study on circular and elliptically shaped pumps. Int. J. Artif. Organs 37:241\u2013252, 2019.","journal-title":"Int. J. Artif. Organs"},{"key":"2590_CR21","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1056\/NEJMoa1800866","volume":"378","author":"MR Mehra","year":"2018","unstructured":"Mehra, M. R., D. J. Goldstein, N. Uriel, J. C. Cleveland, Jr, M. Yuzefpolskaya, et al. Two-year outcomes with a magnetically levitated cardiac pump in heart failure. N. Engl. J. Med. 378:1386\u20131395, 2018.","journal-title":"N. Engl. J. Med."},{"key":"2590_CR22","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/1741-7007-8-11","volume":"8","author":"J Millan","year":"2010","unstructured":"Millan, J., R. J. Cain, N. Reglero-Real, C. Bigarella, B. Marcos-Ramiro, et al. Adherens junctions connect stress fibres between adjacent endothelial cells. BMC Biol. 8:11, 2010.","journal-title":"BMC Biol."},{"key":"2590_CR23","doi-asserted-by":"publisher","first-page":"M487","DOI":"10.1097\/00002480-199609000-00035","volume":"42","author":"VV Nikolaychik","year":"1996","unstructured":"Nikolaychik, V. V., D. M. Wankowski, M. M. Samet, and P. I. Lelkes. In vitro testing of endothelial cell monolayers under dynamic conditions inside a beating ventricular prosthesis. ASAIO J. 42:M487\u2013M494, 1996.","journal-title":"ASAIO J."},{"key":"2590_CR24","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1109\/TBME.2012.2230000","volume":"60","author":"G Ochsner","year":"2013","unstructured":"Ochsner, G., R. Amacher, A. Amstutz, A. Plass, M. Schmid Daners, et al. A novel interface for hybrid mock circulations to evaluate ventricular assist devices. IEEE Trans. Biomed. Eng. 60:507\u2013516, 2013.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2590_CR25","doi-asserted-by":"publisher","first-page":"6248","DOI":"10.1002\/smll.201402579","volume":"11","author":"JH Pang","year":"2015","unstructured":"Pang, J. H., Y. Farhatnia, F. Godarzi, A. Tan, J. Rajadas, et al. In situ endothelialization: bioengineering considerations to translation. Small 11:6248\u20136264, 2015.","journal-title":"Small"},{"key":"2590_CR26","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.actbio.2017.10.038","volume":"65","author":"T Pennel","year":"2018","unstructured":"Pennel, T., D. Bezuidenhout, J. Koehne, N. H. Davies, and P. Zilla. Transmural capillary ingrowth is essential for confluent vascular graft healing. Acta Biomater. 65:237\u2013247, 2018.","journal-title":"Acta Biomater."},{"key":"2590_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2019.12.005","author":"EV Potapov","year":"2020","unstructured":"Potapov, E. V., C. Starck, and V. Falk. Regarding The STS\/Intermacs 2019 Annual Report. Ann. Thorac. Surg. 2020. https:\/\/doi.org\/10.1016\/j.athoracsur.2019.12.005.","journal-title":"Ann. Thorac. Surg."},{"key":"2590_CR28","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1172\/JCI8774","volume":"105","author":"S Rafii","year":"2000","unstructured":"Rafii, S. Circulating endothelial precursors: mystery, reality, and promise. J. Clin. Invest. 105:17\u201319, 2000.","journal-title":"J. Clin. Invest."},{"key":"2590_CR29","first-page":"161","volume":"62","author":"M Rebholz","year":"2017","unstructured":"Rebholz, M., R. Amacher, A. Petrou, M. Meboldt, and M. Schmid Daners. High-frequency operation of a pulsatile VAD: a simulation study. Biomed. Eng-Biomed. Tech. 62:161\u2013170, 2017.","journal-title":"Biomed. Eng-Biomed. Tech."},{"key":"2590_CR30","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1111\/aor.13521","volume":"43","author":"M Rebholz","year":"2019","unstructured":"Rebholz, M., S. A. Dual, M. Batliner, M. Meboldt, and M. Schmid Daners. Short-term physiological response to high-frequency-actuated pVAD support. Artif. Organs 43:1170\u20131181, 2019.","journal-title":"Artif. Organs"},{"key":"2590_CR31","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1111\/aor.12428","volume":"39","author":"DJ Restle","year":"2015","unstructured":"Restle, D. J., D. M. Zhang, G. Hung, J. L. Howard, F. Kallel, et al. Preclinical Models for Translational Investigations of Left Ventricular Assist Device-Associated von Willebrand Factor Degradation. Artif. Organs 39:569\u2013575, 2015.","journal-title":"Artif. Organs"},{"key":"2590_CR32","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1111\/aor.13291","volume":"42","author":"G Rosenberg","year":"2018","unstructured":"Rosenberg, G., C. A. Siedlecki, C. S. Jhun, W. J. Weiss, K. Manning, et al. Acquired Von Willebrand Syndrome and Blood Pump Design. Artif. Organs 42:1119\u20131124, 2018.","journal-title":"Artif. Organs"},{"key":"2590_CR33","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1093\/ejcts\/ezw224","volume":"50","author":"JD Schmitto","year":"2016","unstructured":"Schmitto, J. D., D. Zimpfer, A. E. Fiane, R. Larbalestier, S. Tsui, et al. Long-term support of patients receiving a left ventricular assist device for advanced heart failure: a follow-up analysis of the Registry to Evaluate the HeartWare Left Ventricular Assist System. Eur. J. Cardiothorac. Surg. 50:834\u2013838, 2016.","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"2590_CR34","doi-asserted-by":"publisher","first-page":"II339","DOI":"10.1161\/01.CIR.98.4.339","volume":"98","author":"T Scott-Burden","year":"1998","unstructured":"Scott-Burden, T., C. L. Tock, J. P. Bosely, F. J. Clubb, Jr, S. M. Parnis, et al. Nonthrombogenic, adhesive cellular lining for left ventricular assist devices. Circulation 98:II339\u2013II345, 1998.","journal-title":"Circulation"},{"key":"2590_CR35","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1016\/0003-4975(96)00750-3","volume":"62","author":"JP Slater","year":"1996","unstructured":"Slater, J. P., E. A. Rose, H. R. Levin, O. H. Frazier, J. K. Roberts, et al. Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices. Ann. Thorac. Surg. 62:1321\u20131327, 1996.","journal-title":"Ann. Thorac. Surg."},{"key":"2590_CR36","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jfluidstructs.2012.11.011","volume":"38","author":"SJ Sonntag","year":"2013","unstructured":"Sonntag, S. J., T. A. S. Kaufmann, M. R. Busen, M. Laumen, T. Linde, et al. Simulation of a pulsatile total artificial heart: development of a partitioned Fluid Structure Interaction model. J. Fluid Struct. 38:187\u2013204, 2013.","journal-title":"J. Fluid Struct."},{"key":"2590_CR37","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.athoracsur.2019.12.005","volume":"109","author":"JJ Teuteberg","year":"2020","unstructured":"Teuteberg, J. J., J. C. Cleveland, Jr, J. Cowger, R. S. Higgins, D. J. Goldstein, et al. The Society of Thoracic Surgeons Intermacs 2019 Annual Report: the changing landscape of devices and indications. Ann. Thorac. Surg. 109:649\u2013660, 2020.","journal-title":"Ann. Thorac. Surg."},{"key":"2590_CR38","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1016\/j.medengphy.2011.04.010","volume":"33","author":"D Timms","year":"2011","unstructured":"Timms, D. A review of clinical ventricular assist devices. Med. Eng. Phys. 33:1041\u20131047, 2011.","journal-title":"Med. Eng. Phys."},{"key":"2590_CR39","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.healun.2019.12.011","volume":"39","author":"VK Ton","year":"2020","unstructured":"Ton, V. K., R. Xie, J. A. Hernandez-Montfort, B. Meyns, T. Nakatani, et al. Short- and long-term adverse events in patients on temporary circulatory support before durable ventricular assist device: an IMACS registry analysis. J. Heart Lung Transplant. 39:342\u2013352, 2020.","journal-title":"J. Heart Lung Transplant."},{"key":"2590_CR40","doi-asserted-by":"publisher","first-page":"2106","DOI":"10.1016\/j.jacc.2018.02.075","volume":"71","author":"F Vincent","year":"2018","unstructured":"Vincent, F., A. Rauch, V. Loobuyck, E. Robin, C. Nix, et al. Arterial pulsatility and circulating von Willebrand factor in patients on mechanical circulatory support. J. Am. Coll. Cardiol. 71:2106\u20132118, 2018.","journal-title":"J. Am. Coll. Cardiol."},{"key":"2590_CR41","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1111\/j.1540-8191.1993.tb00574.x","volume":"8","author":"P Zilla","year":"1993","unstructured":"Zilla, P., U. Vonoppell, and M. Deutsch. The endothelium: a key to the future. J. Cardiac Surg. 8:32\u201360, 1993.","journal-title":"J. Cardiac Surg."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-020-02590-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-020-02590-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-020-02590-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,7]],"date-time":"2021-09-07T23:57:07Z","timestamp":1631059027000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10439-020-02590-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,8]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2590"],"URL":"https:\/\/doi.org\/10.1007\/s10439-020-02590-1","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,8]]},"assertion":[{"value":"26 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}