{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T14:05:13Z","timestamp":1783433113054,"version":"3.54.6"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007518","name":"North Dakota State University Foundation","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007518","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100018283","name":"Fifth District Eagles Cancer Telethon","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100018283","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01AR56212"],"award-info":[{"award-number":["R01AR56212"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["K25AG068368"],"award-info":[{"award-number":["K25AG068368"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The goal of this study was to investigate the mechanical performance of vertebral augmentation with various polymer-based materials across different defect sizes. Specifically, this study aimed to identify the optimal stiffness of bone cement that maximizes vertebral strength while minimizing stress redistribution.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>A calibrated quantitative computed tomography-based finite element analysis (QCT\/FEA) approach was developed and calibrated against cadaveric experimental data. Lytic metastatic defects were simulated in human vertebrae at two augmentation volumes (20 and 50%) and filled with materials spanning a wide range of elastic moduli (50 to 2500 MPa). Stress distributions and fracture forces were analyzed in six vertebrae to evaluate the influence of material stiffness and augmentation size.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The QCT\/FEA models accurately predicted vertebral strength (R\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.96) and showed that increased material stiffness leads to higher fracture force but also significantly elevates stress concentrations. An augmentation material with an elastic modulus of approximately 300 MPa offered a favorable balance between strength restoration and minimal stress elevation, especially for 50% augmentation size. Paired t-tests revealed that materials with moduli\u2009\u2264\u2009300 MPa did not produce statistically significant stress redistribution compared to intact bones, while stiffer materials (\u22651000 MPa)  did.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The findings suggest that a bone cement stiffness of approximately 300 MPa may provide optimal mechanical benefits by enhancing vertebral strength without inducing excessive stress redistribution. The study also highlights that augmentation size strongly influences the mechanical outcomes, with larger augmentation volumes showing greater sensitivity to material stiffness. The proposed patient-specific QCT\/FEA framework provides a cost-efficient, adaptable tool for preclinical evaluation and personalized planning of vertebral augmentation These insights can assist material developers in optimizing bone cement formulations for patient-specific treatments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10439-025-03948-z","type":"journal-article","created":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T14:53:20Z","timestamp":1765983200000},"page":"1188-1202","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Optimization of Bone Cement Stiffness in Metastatic Vertebral Augmentation: Balancing Strength Restoration and Stress Redistribution"],"prefix":"10.1007","volume":"54","author":[{"given":"Mehran","family":"Fereydoonpour","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asghar","family":"Rezaei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lichun","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariusz","family":"Ziejewski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0815-0850","authenticated-orcid":false,"given":"Ghodrat","family":"Karami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,17]]},"reference":[{"issue":"4","key":"3948_CR1","doi-asserted-by":"publisher","first-page":"311","DOI":"10.23736\/S0390-5616.22.05642-9","volume":"66","author":"S Sharif","year":"2022","unstructured":"Sharif, S., M. Y. Ali, F. Costa, M. Zileli, and J. Parthiban. Vertebral augmentation in osteoporotic spine fractures: WFNS Spine Committee recommendations. J. Neurosurg. Sci. 66(4):311\u2013326, 2022.","journal-title":"J. Neurosurg. Sci."},{"issue":"3","key":"3948_CR2","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/S0033-8389(05)70042-7","volume":"36","author":"H Deramond","year":"1998","unstructured":"Deramond, H., C. Depriester, P. Galibert, and D. Le Gars. Percutaneous vertebroplasty with polymethylmethacrylate: technique, indications, and results. Radiol. Clin. North. Am. 36(3):533\u2013546, 1998.","journal-title":"Radiol. Clin. North. Am."},{"key":"3948_CR3","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00586-002-0512-9","volume":"12","author":"G Baroud","year":"2003","unstructured":"Baroud, G., J. Nemes, P. Heini, and T. Steffen. Load shift of the intervertebral disc after a vertebroplasty: a finite-element study. Eur. Spine. J. 12:421\u2013426, 2003.","journal-title":"Eur. Spine. J."},{"issue":"5","key":"3948_CR4","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1302\/0301-620X.84B5.0840748","volume":"84","author":"U Berlemann","year":"2002","unstructured":"Berlemann, U., S. Ferguson, L.-P. Nolte, and P. Heini. Adjacent vertebral failure after vertebroplasty: a biomechanical investigation. The J. Bone & Joint Surg. Br. 84(5):748\u2013752, 2002.","journal-title":"The J. Bone & Joint Surg. Br."},{"issue":"1","key":"3948_CR5","first-page":"217","volume":"27","author":"AT Trout","year":"2006","unstructured":"Trout, A. T., D. Kallmes, and T. Kaufmann. New fractures after vertebroplasty: adjacent fractures occur significantly sooner. Am J. Neuroradiol. 27(1):217\u2013223, 2006.","journal-title":"Am J. Neuroradiol."},{"issue":"14","key":"3948_CR6","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1097\/00007632-200107150-00026","volume":"26","author":"I Lieberman","year":"2001","unstructured":"Lieberman, I., S. Dudeney, M.-K. Reinhardt, and G. Bell. Initial outcome and efficacy of \u201ckyphoplasty\u201d in the treatment of painful osteoporotic vertebral compression fractures. Spine. 26(14):1631\u20131637, 2001.","journal-title":"Spine"},{"key":"3948_CR7","first-page":"S85","volume":"16","author":"PF Heini","year":"2005","unstructured":"Heini, P. F. The current treatment\u2014a survey of osteoporotic fracture treatment. Osteoporot. spine fract.: the spine surg. Perspect., Osteoporos. Int. 16:S85\u2013S92, 2005.","journal-title":"Osteoporot. spine fract.: the spine surg. Perspect., Osteoporos. Int."},{"issue":"10","key":"3948_CR8","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1097\/01.BRS.0000061987.71624.17","volume":"28","author":"A Polikeit","year":"2003","unstructured":"Polikeit, A., L. P. Nolte, and S. J. Ferguson. The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis. Spine. 28(10):991\u2013996, 2003.","journal-title":"Spine"},{"issue":"15","key":"3948_CR9","doi-asserted-by":"publisher","first-page":"4239","DOI":"10.1039\/D0BM00413H","volume":"8","author":"S de Lacerda Schickert","year":"2020","unstructured":"de Lacerda Schickert, S., J. C. Pinto, J. Jansen, S. C. Leeuwenburgh, and J. J. van den Beucken. Tough and injectable fiber reinforced calcium phosphate cement as an alternative to polymethylmethacrylate cement for vertebral augmentation: a biomechanical study. Biomater. Sci. 8(15):4239\u20134250, 2020.","journal-title":"Biomater. Sci."},{"key":"3948_CR10","first-page":"141","volume-title":"International conference on advances in glass and glass-ceramics","author":"R Saha","year":"2022","unstructured":"Saha, R., P. Roy, and J. Chakraborty, bioactive glass incorporated plexiglass bone cement: value addition for osteoporotic vertebral compression fracture:(OVCF). In: International conference on advances in glass and glass-ceramics, Springer, 2022, pp. 141\u2013159."},{"issue":"2","key":"3948_CR11","doi-asserted-by":"publisher","first-page":"467","DOI":"10.52312\/jdrs.2022.628","volume":"33","author":"Q Wang","year":"2022","unstructured":"Wang, Q., J.-F. Dong, X. Fang, and Y. Chen. Application and modification of bone cement in vertebroplasty: a literature review. Joint Dis. and Related. Surg. 33(2):467, 2022.","journal-title":"Joint Dis. and Related. Surg."},{"key":"3948_CR12","doi-asserted-by":"crossref","unstructured":"H. Bae, H.P. Hatten Jr, R. Linovitz, A.D. Tahernia, M.K. Schaufele, V. McCollom, L. Gilula, P. Maurer, R. Benyamin, J.M. Mathis, (2012) A prospective randomized FDA-IDE trial comparing Cortoss with PMMA for vertebroplasty: a comparative effectiveness research study with 24-month follow-up, LWW.","DOI":"10.1097\/BRS.0b013e31822ba50b"},{"issue":"4","key":"3948_CR13","first-page":"1110","volume":"40","author":"J Luo","year":"2007","unstructured":"Luo, J., D. M. Skrzypiec, P. Pollintine, M. A. Adams, D. J. Annesley-Williams, and P. Dolan. Mechanical efficacy of vertebroplasty: influence of cement type. BMD, fract. Sev., and Disc. Degener. Bone. 40(4):1110\u20131119, 2007.","journal-title":"BMD, fract. Sev., and Disc. Degener. Bone"},{"issue":"22","key":"3948_CR14","doi-asserted-by":"publisher","first-page":"E1291","DOI":"10.1097\/BRS.0000000000000540","volume":"39","author":"Y Matsuura","year":"2014","unstructured":"Matsuura, Y., H. Giambini, Y. Ogawa, Z. Fang, A. Thoreson, M. Yaszemski, L. Lu, and K. An. Specimen-specific nonlinear finite element modeling to predict vertebrae fracture loads after vertebroplasty. Spine. 39(22):E1291\u2013E1296, 2014.","journal-title":"Spine"},{"key":"3948_CR15","first-page":"143","volume-title":"Injectable cements for vertebroplasty and kyphoplasty","author":"M Bohner","year":"2008","unstructured":"Bohner, M. Injectable cements for vertebroplasty and kyphoplasty. Balloon kyphoplasty: Springer, pp. 143\u2013148, 2008."},{"key":"3948_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2021.104833","volume":"137","author":"A Rezaei","year":"2021","unstructured":"Rezaei, A., M. Tilton, Y. Li, M. J. Yaszemski, and L. Lu. Single-level subject-specific finite element model can predict fracture outcomes in three-level spine segments under different loading rates. Comput. Biol. Med.137:104833, 2021.","journal-title":"Comput. Biol. Med."},{"key":"3948_CR17","doi-asserted-by":"crossref","unstructured":"M. Fereydoonpour, A. Rezaei, A. Schreiber, L. Lu, M. Ziejewski, G. Karami, (2024) Prediction of Vertebral Failure under General Loadings of Compression, Flexion, Extension, and Side-bending, Journal of the Mechanical Behavior of Biomedical Materials 106827.","DOI":"10.1016\/j.jmbbm.2024.106827"},{"issue":"3","key":"3948_CR18","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1097\/00007632-199702010-00002","volume":"22","author":"H Taneichi","year":"1997","unstructured":"Taneichi, H., K. Kaneda, N. Takeda, K. Abumi, and S. Satoh. Risk factors and probability of vertebral body collapse in metastases of the thoracic and lumbar spine. Spine. 22(3):239\u2013245, 1997.","journal-title":"Spine"},{"key":"3948_CR19","doi-asserted-by":"crossref","unstructured":"X. Miao, S. Yang, J. Zhu, Z. Gong, D. Wu, J. Hong, K. Cai, J. Wang, X. Fang, J. Lu, (2023) Bioactive mineralized small intestinal submucosa acellular matrix\/PMMA bone cement for vertebral bone regeneration, Regenerative Biomaterials 10 rbad040.","DOI":"10.1093\/rb\/rbad040"},{"issue":"2","key":"3948_CR20","first-page":"474","volume":"86","author":"A Boger","year":"2008","unstructured":"Boger, A., M. Bohner, P. Heini, S. Verrier, and E. Schneider. Properties of an injectable low modulus PMMA bone cement for osteoporotic bone, Journal of Biomedical Materials Research Part B: Applied Biomaterials: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for. Biomaterials. 86(2):474\u2013482, 2008.","journal-title":"Biomaterials"},{"issue":"7","key":"3948_CR21","doi-asserted-by":"publisher","first-page":"1792","DOI":"10.1002\/jbm.a.34130","volume":"100","author":"DL Alge","year":"2012","unstructured":"Alge, D. L., J. Bennett, T. Treasure, S. Voytik-Harbin, W. S. Goebel, and T. M. G. Chu. Poly (propylene fumarate) reinforced dicalcium phosphate dihydrate cement composites for bone tissue engineering. J. Biomed. Mater. Res. Part A. 100(7):1792\u20131802, 2012.","journal-title":"J. Biomed. Mater. Res. Part A"},{"issue":"8","key":"3948_CR22","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.70081","volume":"41","author":"M Fereydoonpour","year":"2025","unstructured":"Fereydoonpour, M., A. Rezaei, A. Schreiber, L. Lu, M. Ziejewski, and G. Karami. Computational Assessment of Fracture Risk in Vertebral Bodies With Simulated Defects: The Role of Baseline Strength and Tumor Size. Int. J.Numer. Method. Biomed. Eng.41(8):e70081, 2025.","journal-title":"Int. J.Numer. Method. Biomed. Eng"},{"issue":"2","key":"3948_CR23","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.clinbiomech.2007.08.024","volume":"23","author":"B Helgason","year":"2008","unstructured":"Helgason, B., E. Perilli, E. Schileo, F. Taddei, S. Brynj\u00f3lfsson, and M. Viceconti. Mathematical relationships between bone density and mechanical properties: a literature review. Clinical Biomech. 23(2):135\u2013146, 2008.","journal-title":"Clinical Biomech"},{"issue":"13","key":"3948_CR24","doi-asserted-by":"publisher","first-page":"2152","DOI":"10.1016\/j.jbiomech.2013.06.035","volume":"46","author":"S Eberle","year":"2013","unstructured":"Eberle, S., M. G\u00f6ttlinger, and P. Augat. Individual density\u2013elasticity relationships improve accuracy of subject-specific finite element models of human femurs. J. biomech. 46(13):2152\u20132157, 2013.","journal-title":"J. biomech"},{"issue":"3","key":"3948_CR25","doi-asserted-by":"publisher","first-page":"180","DOI":"10.14336\/AD.2014.0621","volume":"6","author":"K Imai","year":"2015","unstructured":"Imai, K. Analysis of vertebral bone strength, fracture pattern, and fracture location: a validation study using a computed tomography-based nonlinear finite element analysis. Aging and dis. 6(3):180, 2015.","journal-title":"Aging and dis"},{"issue":"9","key":"3948_CR26","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0272529","volume":"17","author":"C Garavelli","year":"2022","unstructured":"Garavelli, C., C. Curreli, M. Palanca, A. Aldieri, L. Cristofolini, and M. Viceconti. Experimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation. PLoS One.17(9):0272529, 2022.","journal-title":"PLoS One"},{"key":"3948_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104872","volume":"125","author":"M Palanca","year":"2022","unstructured":"Palanca, M., S. Oliviero, and E. Dall\u2019Ara,. MicroFE models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation. J. Mech Behav. Biomed. Mat.125:104872, 2022.","journal-title":"J. Mech Behav. Biomed. Mat."},{"key":"3948_CR28","doi-asserted-by":"crossref","unstructured":"C. Garavelli, A. Aldieri, M. Palanca, E. Dall\u2019Ara, M. Viceconti, (2025) Comparing the predictions of CT-based subject-specific finite element models of human metastatic vertebrae with digital volume correlation measurements, Biomechanics and Modeling in Mechanobiology 1-14.","DOI":"10.1007\/s10237-025-01950-x"},{"issue":"2","key":"3948_CR29","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/0021-9290(93)90042-D","volume":"26","author":"JY Rho","year":"1993","unstructured":"Rho, J. Y., R. B. Ashman, and C. H. Turner. Young\u2019s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J. biomech. 26(2):111\u2013119, 1993.","journal-title":"J. biomech."},{"issue":"4","key":"3948_CR30","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1243\/09544119H00305","volume":"220","author":"R Wilcox","year":"2006","unstructured":"Wilcox, R. The biomechanical effect of vertebroplasty on the adjacent vertebral body: a finite element study. Proc. Instit. Mech. Eng. Part H: J. Eng. in Med. 220(4):565\u2013572, 2006.","journal-title":"Proc. Instit. Mech. Eng. Part H: J. Eng. in Med."},{"key":"3948_CR31","doi-asserted-by":"publisher","first-page":"2118","DOI":"10.1007\/s00586-007-0473-0","volume":"16","author":"A Boger","year":"2007","unstructured":"Boger, A., P. Heini, M. Windolf, and E. Schneider. Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement. Eur Spine J. 16:2118\u20132125, 2007.","journal-title":"Eur Spine J."},{"key":"3948_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104437","volume":"118","author":"C Robo","year":"2021","unstructured":"Robo, C., C. \u00d6hman-M\u00e4gi, and C. Persson. Long-term mechanical properties of a novel low-modulus bone cement for the treatment of osteoporotic vertebral compression fractures. J. Mech. Behav. Biomed. Mater.118:104437, 2021.","journal-title":"J. Mech. Behav. Biomed. Mater"},{"key":"3948_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.nxmate.2025.100943","volume":"9","author":"A Kumar","year":"2025","unstructured":"Kumar, A. Biomechanics of interfaces for cemented joint replacements: A systematic review. Next Mater.9:100943, 2025.","journal-title":"Next Mater."},{"key":"3948_CR34","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s12178-007-9013-0","volume":"1","author":"T McCall","year":"2008","unstructured":"McCall, T., C. Cole, and A. Dailey. Vertebroplasty and kyphoplasty: a comparative review of efficacy and adverse events. Curr. Rev. in Musculoskel. Med. 1:17\u201323, 2008.","journal-title":"Curr. Rev. in Musculoskel. Med."},{"issue":"11","key":"3948_CR35","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s11517-018-1844-x","volume":"56","author":"Y Peng","year":"2018","unstructured":"Peng, Y., X. Du, L. Huang, J. Li, R. Zhan, W. Wang, B. Xu, S. Wu, C. Peng, and S. Chen. Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling. Med. & Biol. Eng. & Comput. 56(11):2137\u20132150, 2018.","journal-title":"Med. & Biol. Eng. & Comput."},{"key":"3948_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2023.105889","volume":"102","author":"L Eliyahu","year":"2023","unstructured":"Eliyahu, L., Z. Yosibash, I. Avivi, Y. C. Cohen, G. Ariel, O. Sadovnic, and A. Sternheim. On the influence of computed tomography\u2019s slice thickness on computer tomography based finite element analyses results. Clin. Biomech.102:105889, 2023.","journal-title":"Clin. Biomech."},{"key":"3948_CR37","doi-asserted-by":"crossref","unstructured":"M. Fereydoonpour, J. Mclean, M. Ziejewski, G. Karami, A Dynamic Mode Decomposition Method for Modal Analysis of Human Brain Diagnosis, ASME International Mechanical Engineering Congress and Exposition, American Society of Mechanical Engineers, 2022, p. V004T05A045.","DOI":"10.1115\/IMECE2022-96394"}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-025-03948-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-025-03948-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-025-03948-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T13:32:12Z","timestamp":1774877532000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10439-025-03948-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,17]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["3948"],"URL":"https:\/\/doi.org\/10.1007\/s10439-025-03948-z","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,17]]},"assertion":[{"value":"7 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Cadaveric samples used in this study were obtained through a previously approved protocol by the Mayo Clinic Institutional Review Board (IRB). The study did not involve living human participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}]}}