{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T18:45:12Z","timestamp":1790621112091,"version":"4.1.0"},"reference-count":239,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T00:00:00Z","timestamp":1785369600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T00:00:00Z","timestamp":1785369600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["CBET-2505739"],"award-info":[{"award-number":["CBET-2505739"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Continuous monitoring of chronic diseases with mobile health tools is rapidly advancing to improve patient care. Wearable sensors placed on or near the skin remain the dominant paradigm for collecting physiological data noninvasively during activities of daily living. However, wearable sensors have their limitations. Epidermal sensors are fundamentally limited by the information barrier that the skin presents. Furthermore, environmental factors impact the stability and longevity of wearables. An alternative technology is the expanding class of minimally invasive subdermal sensors, also called insertables. Key applications for subdermal sensors are reviewed, including three current clinical devices: insertable cardiac monitors, insertable continuous glucose monitors, and sub-scalp epilepsy monitors. Next, common challenges impacting performance are discussed, including device migration, device encapsulation, and misalignment with wirelessly linked wearables. Finally, recent technological advancements to mitigate these challenges are covered. With state-of-the-art approaches for achieving biocompatibility, remote powering, and wireless data transmission, the next generation of subdermal biosensors can be developed for unmet needs in chronic disease monitoring.<\/jats:p>","DOI":"10.1007\/s10439-026-04297-1","type":"journal-article","created":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T13:28:54Z","timestamp":1785418134000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Subdermal Insertable Sensors for Health Monitoring: Applications, Challenges, and Emerging Technologies"],"prefix":"10.1007","author":[{"given":"Haoyuan","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xilin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4752-3867","authenticated-orcid":false,"given":"Andrew G.","family":"Richardson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,30]]},"reference":[{"issue":"1","key":"4297_CR1","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.mayocpiqo.2023.08.005","volume":"8","author":"K Hacker","year":"2024","unstructured":"Hacker, K. The burden of chronic disease. Mayo Clin. Proc. Innov. Qual. Outcomes. 8(1):112\u2013119, 2024. https:\/\/doi.org\/10.1016\/j.mayocpiqo.2023.08.005.","journal-title":"Mayo Clin. Proc. Innov. Qual. Outcomes"},{"issue":"4","key":"4297_CR2","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1001\/jama.2014.17125","volume":"313","author":"EJ Topol","year":"2015","unstructured":"Topol, E. J., S. R. Steinhubl, and A. Torkamani. Digital medical tools and sensors. JAMA. 313(4):353, 2015. https:\/\/doi.org\/10.1001\/jama.2014.17125.","journal-title":"JAMA"},{"issue":"5","key":"4297_CR3","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1177\/1357633X20937573","volume":"28","author":"T Kamei","year":"2022","unstructured":"Kamei, T., T. Kanamori, Y. Yamamoto, and S. Edirippulige. The use of wearable devices in chronic disease management to enhance adherence and improve telehealth outcomes: a systematic review and meta-analysis. J. Telemed. Telecare. 28(5):342\u2013359, 2022. https:\/\/doi.org\/10.1177\/1357633X20937573.","journal-title":"J. Telemed. Telecare"},{"issue":"5","key":"4297_CR4","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1089\/tmj.2019.0066","volume":"26","author":"FACD Farias","year":"2020","unstructured":"Farias, F. A. C. D., C. M. Dagostini, Y. D. A. Bicca, V. F. Falavigna, and A. Falavigna. Remote patient monitoring: a systematic review. Telemed. e-Health. 26(5):576\u2013583, 2020. https:\/\/doi.org\/10.1089\/tmj.2019.0066.","journal-title":"Telemed. e-Health"},{"issue":"12","key":"4297_CR5","doi-asserted-by":"publisher","first-page":"2750","DOI":"10.1109\/TBME.2015.2422751","volume":"62","author":"J Andreu-Perez","year":"2015","unstructured":"Andreu-Perez, J., D. R. Leff, H. M. D. Ip, and G.-Z. Yang. From wearable sensors to smart implants\u2014toward pervasive and personalized healthcare. IEEE Trans. Biomed. Eng. 62(12):2750\u20132762, 2015. https:\/\/doi.org\/10.1109\/TBME.2015.2422751.","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"20","key":"4297_CR6","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1056\/NEJMoa1901183","volume":"381","author":"MV Perez","year":"2019","unstructured":"Perez, M. V., K. W. Mahaffey, H. Hedlin, J. S. Rumsfeld, A. Garcia, T. Ferris, V. Balasubramanian, A. M. Russo, A. Rajmane, L. Cheung, G. Hung, J. Lee, P. Kowey, N. Talati, D. Nag, S. E. Gummidipundi, A. Beatty, M. T. Hills, S. Desai, C. B. Granger, M. Desai, and M. P. Turakhia. Large-scale assessment of a smartwatch to identify atrial fibrillation. N. Engl. J. Med. 381(20):1909\u20131917, 2019. https:\/\/doi.org\/10.1056\/NEJMoa1901183.","journal-title":"N. Engl. J. Med."},{"issue":"10","key":"4297_CR7","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1038\/s41551-023-01095-1","volume":"7","author":"Y Xu","year":"2023","unstructured":"Xu, Y., E. De La Paz, A. Paul, K. Mahato, J. R. Sempionatto, N. Tostado, M. Lee, G. Hota, M. Lin, A. Uppal, W. Chen, S. Dua, L. Yin, B. L. Wuerstle, S. Deiss, P. Mercier, S. Xu, J. Wang, and G. Cauwenberghs. In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat. Nat. Biomed. Eng. 7(10):1307\u20131320, 2023. https:\/\/doi.org\/10.1038\/s41551-023-01095-1.","journal-title":"Nat. Biomed. Eng."},{"issue":"14","key":"4297_CR8","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1056\/NEJMoa0805017","volume":"359","author":"The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group","year":"2008","unstructured":"The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N. Engl. J. Med. 359(14):1464\u20131476, 2008. https:\/\/doi.org\/10.1056\/NEJMoa0805017.","journal-title":"N. Engl. J. Med."},{"issue":"6044","key":"4297_CR9","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1126\/science.1206157","volume":"333","author":"D-H Kim","year":"2011","unstructured":"Kim, D.-H., N. Lu, R. Ma, Y.-S. Kim, R.-H. Kim, S. Wang, J. Wu, S. M. Won, H. Tao, A. Islam, K. J. Yu, T.-I. Kim, R. Chowdhury, M. Ying, L. Xu, M. Li, H.-J. Chung, H. Keum, M. McCormick, P. Liu, Y.-W. Zhang, F. G. Omenetto, Y. Huang, T. Coleman, and J. A. Rogers. Epidermal electronics. Science. 333(6044):838\u2013843, 2011. https:\/\/doi.org\/10.1126\/science.1206157.","journal-title":"Science"},{"issue":"1","key":"4297_CR10","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3390\/s17010130","volume":"17","author":"S Majumder","year":"2017","unstructured":"Majumder, S., T. Mondal, and M. Deen. Wearable sensors for remote health monitoring. Sensors. 17(1):130, 2017. https:\/\/doi.org\/10.3390\/s17010130.","journal-title":"Sensors"},{"issue":"10","key":"4297_CR11","doi-asserted-by":"publisher","first-page":"9614","DOI":"10.1021\/acsnano.7b04898","volume":"11","author":"Y Liu","year":"2017","unstructured":"Liu, Y., M. Pharr, and G. A. Salvatore. Lab-on-skin: a review of flexible and stretchable electronics for wearable health monitoring. ACS Nano. 11(10):9614\u20139635, 2017. https:\/\/doi.org\/10.1021\/acsnano.7b04898.","journal-title":"ACS Nano"},{"issue":"2","key":"4297_CR12","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1039\/C7LC00914C","volume":"18","author":"J Heikenfeld","year":"2018","unstructured":"Heikenfeld, J., A. Jajack, J. Rogers, P. Gutruf, L. Tian, T. Pan, R. Li, M. Khine, J. Kim, J. Wang, and J. Kim. Wearable sensors: modalities, challenges, and prospects. Lab. Chip. 18(2):217\u2013248, 2018. https:\/\/doi.org\/10.1039\/C7LC00914C.","journal-title":"Lab. Chip"},{"issue":"5","key":"4297_CR13","doi-asserted-by":"publisher","first-page":"2007495","DOI":"10.1002\/adfm.202007495","volume":"31","author":"S Wang","year":"2021","unstructured":"Wang, S., Y. Fang, H. He, L. Zhang, C. Li, and J. Ouyang. Wearable stretchable dry and self-adhesive strain sensors with conformal contact to skin for high-quality motion monitoring. Adv. Funct. Mater. 31(5):2007495, 2021. https:\/\/doi.org\/10.1002\/adfm.202007495.","journal-title":"Adv. Funct. Mater."},{"issue":"3","key":"4297_CR14","doi-asserted-by":"publisher","first-page":"032023","DOI":"10.1088\/1742-6596\/1237\/3\/032023","volume":"1237","author":"F Zhang","year":"2019","unstructured":"Zhang, F., X. Li, B. Duan, C. Zhang, and L. Hu. Effect of skin layer on electric impedance scanning imaging. J. Phys. Conf. Ser. 1237(3):032023, 2019. https:\/\/doi.org\/10.1088\/1742-6596\/1237\/3\/032023.","journal-title":"J. Phys. Conf. Ser."},{"issue":"4","key":"4297_CR15","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1007\/s10103-019-02888-0","volume":"35","author":"HC Jo","year":"2020","unstructured":"Jo, H. C., and D. Y. Kim. Correlation between light absorbance and skin color using fabricated skin phantoms with different colors. Lasers Med. Sci. 35(4):919\u2013926, 2020. https:\/\/doi.org\/10.1007\/s10103-019-02888-0.","journal-title":"Lasers Med. Sci."},{"issue":"6","key":"4297_CR16","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1046\/j.0022-202x.2001.01577.x","volume":"117","author":"G Zonios","year":"2001","unstructured":"Zonios, G., J. Bykowski, and N. Kollias. Skin melanin, hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy. J. Investig. Dermatol. 117(6):1452\u20131457, 2001. https:\/\/doi.org\/10.1046\/j.0022-202x.2001.01577.x.","journal-title":"J. Investig. Dermatol."},{"issue":"18","key":"4297_CR17","doi-asserted-by":"publisher","first-page":"8044","DOI":"10.1039\/D3NR00807J","volume":"15","author":"D Rybak","year":"2023","unstructured":"Rybak, D., Y.-C. Su, Y. Li, B. Ding, X. Lv, Z. Li, Y.-C. Yeh, P. Nakielski, C. Rinoldi, F. Pierini, and J. M. Dodda. Evolution of nanostructured skin patches towards multifunctional wearable platforms for biomedical applications. Nanoscale. 15(18):8044\u20138083, 2023. https:\/\/doi.org\/10.1039\/D3NR00807J.","journal-title":"Nanoscale"},{"issue":"23","key":"4297_CR18","doi-asserted-by":"publisher","first-page":"1700648","DOI":"10.1002\/aenm.201700648","volume":"7","author":"S Gong","year":"2017","unstructured":"Gong, S., and W. Cheng. Toward soft skin-like wearable and implantable energy devices. Adv. Energy Mater. 7(23):1700648, 2017. https:\/\/doi.org\/10.1002\/aenm.201700648.","journal-title":"Adv. Energy Mater."},{"issue":"3","key":"4297_CR19","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1111\/iwj.13650","volume":"19","author":"A Grigatti","year":"2022","unstructured":"Grigatti, A., and A. Gefen. What makes a hydrogel-based dressing advantageous for the prevention of medical device-related pressure ulcers. Int. Wound J. 19(3):515\u2013530, 2022. https:\/\/doi.org\/10.1111\/iwj.13650.","journal-title":"Int. Wound J."},{"issue":"6","key":"4297_CR20","doi-asserted-by":"publisher","first-page":"062002","DOI":"10.1088\/2057-1976\/ab4b32","volume":"5","author":"AS Barbone","year":"2019","unstructured":"Barbone, A. S., M. Meftah, K. Markiewicz, and K. Dellimore. Beyond wearables and implantables: a scoping review of insertable medical devices. Biomed. Phys. Eng. Express. 5(6):062002, 2019. https:\/\/doi.org\/10.1088\/2057-1976\/ab4b32.","journal-title":"Biomed. Phys. Eng. Express"},{"issue":"7","key":"4297_CR21","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1038\/s41928-021-00614-9","volume":"4","author":"SM Mirvakili","year":"2021","unstructured":"Mirvakili, S. M., and R. Langer. Wireless on-demand drug delivery. Nat. Electron. 4(7):464\u2013477, 2021. https:\/\/doi.org\/10.1038\/s41928-021-00614-9.","journal-title":"Nat. Electron."},{"issue":"9","key":"4297_CR22","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1111\/j.1526-4637.2011.01201.x","volume":"12","author":"P Verrills","year":"2011","unstructured":"Verrills, P., D. Vivian, B. Mitchell, and A. Barnard. Peripheral nerve field stimulation for chronic pain: 100 cases and review of the literature. Pain Med. 12(9):1395\u20131405, 2011. https:\/\/doi.org\/10.1111\/j.1526-4637.2011.01201.x.","journal-title":"Pain Med."},{"issue":"11","key":"4297_CR23","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1016\/j.jacep.2018.06.001","volume":"4","author":"S Giancaterino","year":"2018","unstructured":"Giancaterino, S., F. Lupercio, M. Nishimura, and J. C. Hsu. Current and future use of insertable cardiac monitors. JACC Clin. Electrophysiol. 4(11):1383\u20131396, 2018. https:\/\/doi.org\/10.1016\/j.jacep.2018.06.001.","journal-title":"JACC Clin. Electrophysiol."},{"issue":"5","key":"4297_CR24","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1089\/dia.2024.0592","volume":"27","author":"TS Bailey","year":"2025","unstructured":"Bailey, T. S., D. R. Liljenquist, D. S. Denham, R. L. Brazg, S. Ioacara, J. Masciotti, S. Ghosh-Dastidar, K. S. Tweden, and F. R. Kaufman. Evaluation of accuracy and safety of the 365-day implantable Eversense continuous glucose monitoring system: the ENHANCE study. Diabetes Technol. Ther. 27(5):407\u2013411, 2025. https:\/\/doi.org\/10.1089\/dia.2024.0592.","journal-title":"Diabetes Technol. Ther."},{"key":"4297_CR25","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.clinph.2022.07.003","volume":"141","author":"Z Haneef","year":"2022","unstructured":"Haneef, Z., K. Yang, S. A. Sheth, F. Z. Aloor, B. Aazhang, V. Krishnan, and C. Karakas. Sub-scalp electroencephalography: a next-generation technique to study human neurophysiology. Clin. Neurophysiol. 141:77\u201387, 2022. https:\/\/doi.org\/10.1016\/j.clinph.2022.07.003.","journal-title":"Clin. Neurophysiol."},{"key":"4297_CR26","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/978-3-030-30457-7_6","volume-title":"Technology-Augmented Perception and Cognition","author":"KJ Heffernan","year":"2021","unstructured":"Heffernan, K. J., F. Vetere, and S. Chang. Insertables: beyond cyborgs and augmentation to convenience and amenity. In: Technology-Augmented Perception and Cognition, edited by T. Dingler, and E. Niforatos. Cham: Springer, 2021, pp. 185\u2013227. https:\/\/doi.org\/10.1007\/978-3-030-30457-7_6."},{"issue":"1","key":"4297_CR27","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1097\/CRD.0000000000000129","volume":"25","author":"TT Tomson","year":"2017","unstructured":"Tomson, T. T., and R. Passman. Current and emerging uses of insertable cardiac monitors: evaluation of syncope and monitoring for atrial fibrillation. Cardiol. Rev. 25(1):22\u201329, 2017. https:\/\/doi.org\/10.1097\/CRD.0000000000000129.","journal-title":"Cardiol. Rev."},{"key":"4297_CR28","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jelectrocard.2022.11.007","volume":"77","author":"AA Al Qurashi","year":"2023","unstructured":"Al Qurashi, A. A., F. Rasheed, A. R. Siddiqi, M. Abdullah, M. Mumtaz, T. Khan, A. H. Mallick, S. Jabeen, I. E. Ahmed, and R. K. Ochani. Insertable cardiac monitoring devices versus external cardiac monitoring for detecting atrial fibrillation and preventing the recurrence of stroke: a systematic review and meta-analysis. J. Electrocardiol. 77:29\u201336, 2023. https:\/\/doi.org\/10.1016\/j.jelectrocard.2022.11.007.","journal-title":"J. Electrocardiol."},{"issue":"7","key":"4297_CR29","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1111\/pace.13728","volume":"42","author":"C Piorkowski","year":"2019","unstructured":"Piorkowski, C., M. Busch, G. N\u00f6lker, J. Schmitt, F. X. Roithinger, G. Young, M. T\u00e1borsk\u00fd, G. Herrmann, and D. Schmitz. Clinical evaluation of a small implantable cardiac monitor with a long sensing vector. Pacing Clin. Electrophysiol. 42(7):1038\u20131046, 2019. https:\/\/doi.org\/10.1111\/pace.13728.","journal-title":"Pacing Clin. Electrophysiol."},{"key":"4297_CR30","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jelectrocard.2020.04.004","volume":"60","author":"JA Mariani","year":"2020","unstructured":"Mariani, J. A., R. Weerasooriya, O. Van Den Brink, U. Mohamed, P. A. Gould, R. K. Pathak, T. Lin, A. Conradie, P. Illes, S. Pavia, K. Rajamani, S. Lovibond, I. Matthews, D. DiFiore, D. Arumugam, J. Schrader, and D. H. Lau. Miniaturized implantable cardiac monitor with a long sensing vector (Biomonitor III): insertion procedure assessment, sensing performance, and home monitoring transmission success. J. Electrocardiol. 60:118\u2013125, 2020. https:\/\/doi.org\/10.1016\/j.jelectrocard.2020.04.004.","journal-title":"J. Electrocardiol."},{"key":"4297_CR31","doi-asserted-by":"publisher","first-page":"934","DOI":"10.3389\/fneur.2020.00934","volume":"11","author":"I Campanini","year":"2020","unstructured":"Campanini, I., C. Disselhorst-Klug, W. Z. Rymer, and R. Merletti. Surface EMG in clinical assessment and neurorehabilitation: barriers limiting its use. Front. Neurol. 11:934, 2020. https:\/\/doi.org\/10.3389\/fneur.2020.00934.","journal-title":"Front. Neurol."},{"issue":"1","key":"4297_CR32","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1109\/TBME.2008.2005942","volume":"56","author":"RF Weir","year":"2009","unstructured":"Weir, R. F., P. R. Troyk, G. A. DeMichele, D. A. Kerns, J. F. Schorsch, and H. Maas. Implantable myoelectric sensors (IMESs) for intramuscular electromyogram recording. IEEE Trans. Biomed. Eng. 56(1):159\u2013171, 2009. https:\/\/doi.org\/10.1109\/TBME.2008.2005942.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"4297_CR33","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.jneumeth.2014.07.016","volume":"244","author":"PF Pasquina","year":"2015","unstructured":"Pasquina, P. F., M. Evangelista, A. J. Carvalho, J. Lockhart, S. Griffin, G. Nanos, P. McKay, M. Hansen, D. Ipsen, J. Vandersea, J. Butkus, M. Miller, I. Murphy, and D. Hankin. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand. J. Neurosci. Methods. 244:85\u201393, 2015. https:\/\/doi.org\/10.1016\/j.jneumeth.2014.07.016.","journal-title":"J. Neurosci. Methods"},{"key":"4297_CR34","doi-asserted-by":"publisher","unstructured":"Alexandrov, G., and J. M. Rabaey. Wireless power transfer to randomly distributed implants via homogeneous magnetic fields. In: 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS), 2019, pp. 1\u20134. https:\/\/doi.org\/10.1109\/BIOCAS.2019.8918735.","DOI":"10.1109\/BIOCAS.2019.8918735"},{"issue":"3","key":"4297_CR35","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.neuron.2016.06.034","volume":"91","author":"D Seo","year":"2016","unstructured":"Seo, D., R. M. Neely, K. Shen, U. Singhal, E. Alon, J. M. Rabaey, J. M. Carmena, and M. M. Maharbiz. Wireless recording in the peripheral nervous system with ultrasonic neural dust. Neuron. 91(3):529\u2013539, 2016. https:\/\/doi.org\/10.1016\/j.neuron.2016.06.034.","journal-title":"Neuron"},{"issue":"9","key":"4297_CR36","doi-asserted-by":"publisher","first-page":"1805","DOI":"10.1111\/epi.16630","volume":"61","author":"J Duun-Henriksen","year":"2020","unstructured":"Duun-Henriksen, J., M. Baud, M. P. Richardson, M. Cook, G. Kouvas, J. M. Heasman, D. Friedman, J. Peltola, I. C. Zibrandtsen, and T. W. Kjaer. A new era in electroencephalographic monitoring? Subscalp devices for ultra-long-term recordings. Epilepsia. 61(9):1805\u20131817, 2020. https:\/\/doi.org\/10.1111\/epi.16630.","journal-title":"Epilepsia"},{"issue":"11","key":"4297_CR37","doi-asserted-by":"publisher","first-page":"2204","DOI":"10.1111\/epi.16360","volume":"60","author":"S Weisdorf","year":"2019","unstructured":"Weisdorf, S., J. Duun-Henriksen, M. J. Kjeldsen, F. R. Poulsen, S. W. Gangstad, and T. W. Kj\u00e6r. Ultra-long-term subcutaneous home monitoring of epilepsy\u2014490 days of EEG from nine patients. Epilepsia. 60(11):2204\u20132214, 2019. https:\/\/doi.org\/10.1111\/epi.16360.","journal-title":"Epilepsia"},{"key":"4297_CR38","doi-asserted-by":"publisher","DOI":"10.1111\/epi.18566","author":"PF Viana","year":"2025","unstructured":"Viana, P. F., J. Duun-Henriksen, A. Biondi, J. S. Winston, D. R. Freestone, A. Schulze-Bonhage, B. H. Brinkmann, and M. P. Richardson. Real-world epilepsy monitoring with ultra-long-term subcutaneous electroencephalography: a 15-month prospective study. Epilepsia. 2025. https:\/\/doi.org\/10.1111\/epi.18566.","journal-title":"Epilepsia"},{"issue":"9","key":"4297_CR39","doi-asserted-by":"publisher","first-page":"3426","DOI":"10.1111\/epi.18458","volume":"66","author":"AJ Halliday","year":"2025","unstructured":"Halliday, A. J., L. Gillinder, A. Lai, U. Seneviratne, H. Fontenot, T. Cameron, K. McLean, A. Niemiec, R. Raghupathi, T. M. Ganguly, C. Ellis, E. C. Conrad, R. Briggs, K. Bulluss, P. Kwan, P. Perucca, T. J. O\u2019Brien, A. McGonigal, M. Gutman, J. Papacostas, M. W. K. Fong, A. Lee, D. E. Crompton, J. Laing, M. Wijayath, A. P. Morokoff, M. Murphy, W. J. D\u2019Souza, and M. J. Cook. A first-in-human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection. Epilepsia. 66(9):3426\u20133439, 2025. https:\/\/doi.org\/10.1111\/epi.18458.","journal-title":"Epilepsia"},{"issue":"5","key":"4297_CR40","doi-asserted-by":"publisher","first-page":"6292","DOI":"10.19102\/icrm.2025.16056","volume":"16","author":"A Mauriello","year":"2025","unstructured":"Mauriello, A., A. Rago, D. Amore, G. Sica, A. D\u2019Andrea, and V. Russo. Migration of an implantable loop recorder: a meta-summary of case reports. J. Innov. Card. Rhythm Manag. 16(5):6292\u20136296, 2025.","journal-title":"J. Innov. Card. Rhythm Manag."},{"key":"4297_CR41","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jelectrocard.2022.05.008","volume":"73","author":"BM Pitman","year":"2022","unstructured":"Pitman, B. M., K. Kadhim, R. Tarone, E. Jones, D. Linz, M. Lim, K. M. Heath, N. Scanlan, K. C. Roberts-Thomson, G. D. Young, C. X. Wong, P. Sanders, J. A. Mariani, and D. H. Lau. Impact of device length on electrogram sensing in miniaturized insertable cardiac monitors. J. Electrocardiol. 73:42\u201348, 2022. https:\/\/doi.org\/10.1016\/j.jelectrocard.2022.05.008.","journal-title":"J. Electrocardiol."},{"key":"4297_CR42","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1038\/nmat4671","volume":"15","author":"A Chortos","year":"2016","unstructured":"Chortos, A., J. Liu, and Z. Bao. Pursuing prosthetic electronic skin. Nat. Mater. 15:937\u2013950, 2016. https:\/\/doi.org\/10.1038\/nmat4671.","journal-title":"Nat. Mater."},{"issue":"10081","key":"4297_CR43","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1016\/S0140-6736(17)30601-3","volume":"389","author":"AB Ajiboye","year":"2017","unstructured":"Ajiboye, A. B., F. R. Willett, D. R. Young, W. D. Memberg, B. A. Murphy, J. P. Miller, et al. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. Lancet. 389(10081):1821\u20131830, 2017. https:\/\/doi.org\/10.1016\/S0140-6736(17)30601-3.","journal-title":"Lancet"},{"key":"4297_CR44","doi-asserted-by":"publisher","DOI":"10.1021\/acsnano.0c10141","author":"I Shlomy","year":"2021","unstructured":"Shlomy, I., S. Divald, K. Tadmor, Y. Leichtmann-Bardoogo, A. Arami, and B. M. Maoz. Restoring tactile sensation using a triboelectric nanogenerator. ACS Nano. 2021. https:\/\/doi.org\/10.1021\/acsnano.0c10141.","journal-title":"ACS Nano"},{"issue":"1","key":"4297_CR45","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1038\/s41378-023-00602-3","volume":"9","author":"L Du","year":"2023","unstructured":"Du, L., H. Hao, Y. Ding, A. Gabros, T. C. E. Mier, J. Van Der Spiegel, T. H. Lucas, F. Aflatouni, A. G. Richardson, and M. G. Allen. An implantable, wireless, battery-free system for tactile pressure sensing. Microsyst. Nanoeng. 9(1):130, 2023. https:\/\/doi.org\/10.1038\/s41378-023-00602-3.","journal-title":"Microsyst. Nanoeng."},{"issue":"6","key":"4297_CR46","doi-asserted-by":"publisher","first-page":"2907","DOI":"10.1109\/TMTT.2021.3072398","volume":"69","author":"H Hao","year":"2021","unstructured":"Hao, H., L. Du, A. G. Richardson, T. H. Lucas, M. G. Allen, J. V. D. Spiegel, and F. Aflatouni. A wireless artificial mechanoreceptor in 180-nm CMOS. IEEE Trans. Microw. Theory Tech. 69(6):2907\u20132920, 2021. https:\/\/doi.org\/10.1109\/TMTT.2021.3072398.","journal-title":"IEEE Trans. Microw. Theory Tech."},{"issue":"7","key":"4297_CR47","doi-asserted-by":"publisher","first-page":"11205","DOI":"10.1109\/JSEN.2024.3366195","volume":"24","author":"P Ahmmed","year":"2024","unstructured":"Ahmmed, P., J. Reynolds, and A. Bozkurt. A subcutaneously injectable implant for multimodal physiological monitoring in animals. IEEE Sens. J. 24(7):11205\u201311216, 2024. https:\/\/doi.org\/10.1109\/JSEN.2024.3366195.","journal-title":"IEEE Sens. J."},{"issue":"5","key":"4297_CR48","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1109\/TBCAS.2019.2923153","volume":"13","author":"J Reynolds","year":"2019","unstructured":"Reynolds, J., P. Ahmmed, and A. Bozkurt. An injectable system for subcutaneous photoplethysmography, accelerometry, and thermometry in animals. IEEE Trans. Biomed. Circuits Syst. 13(5):825\u2013834, 2019. https:\/\/doi.org\/10.1109\/TBCAS.2019.2923153.","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"issue":"11","key":"4297_CR49","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1016\/j.neuron.2024.02.020","volume":"112","author":"W Ouyang","year":"2024","unstructured":"Ouyang, W., K. J. Kilner, R. M. P. Xavier, Y. Liu, Y. Lu, S. M. Feller, K. M. Pitts, M. Wu, J. Ausra, I. Jones, Y. Wu, H. Luan, J. Trueb, E. M. Higbee-Dempsey, I. Stepien, N. Ghoreishi-Haack, C. R. Haney, H. Li, Y. Kozorovitskiy, M. Heshmati, A. R. Banks, S. A. Golden, C. H. Good, and J. A. Rogers. An implantable device for wireless monitoring of diverse physio-behavioral characteristics in freely behaving small animals and interacting groups. Neuron. 112(11):1764\u20131777, 2024. https:\/\/doi.org\/10.1016\/j.neuron.2024.02.020.","journal-title":"Neuron"},{"key":"4297_CR50","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1007\/s11325-020-02268-x","volume":"25","author":"K Montazeri","year":"2021","unstructured":"Montazeri, K., S. A. Jonsson, J. S. Agustsson, M. Serwatko, T. Gislason, and E. S. Arnardottir. The design of rip belts impacts the reliability and quality of the measured respiratory signals. Sleep Breath. 25:1535\u20131541, 2021. https:\/\/doi.org\/10.1007\/s11325-020-02268-x.","journal-title":"Sleep Breath."},{"key":"4297_CR51","doi-asserted-by":"publisher","unstructured":"\u00c1lvarez, R. C., P.-Y. Joubert, and D. Feuerstein. Subcutaneous accelerometer-based monitoring of respiration: a pre-clinical exploration. In: 2019 13th International Symposium on Medical Information and Communication Technology (ISMICT), 2019, pp. 1\u20136. https:\/\/doi.org\/10.1109\/ISMICT.2019.8743996.","DOI":"10.1109\/ISMICT.2019.8743996"},{"issue":"Suppl 34","key":"4297_CR52","doi-asserted-by":"publisher","first-page":"4221","DOI":"10.21037\/jtd.2018.12.63","volume":"10","author":"GR Geovanini","year":"2018","unstructured":"Geovanini, G. R., and G. Lorenzi-Filho. Cardiac rhythm disorders in obstructive sleep apnea. J. Thorac. Dis. 10(Suppl 34):4221\u20134230, 2018. https:\/\/doi.org\/10.21037\/jtd.2018.12.63.","journal-title":"J. Thorac. Dis."},{"issue":"3","key":"4297_CR53","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/0967-3334\/28\/3\/R01","volume":"28","author":"J Allen","year":"2007","unstructured":"Allen, J. Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28(3):1\u201339, 2007. https:\/\/doi.org\/10.1088\/0967-3334\/28\/3\/R01.","journal-title":"Physiol. Meas."},{"issue":"4","key":"4297_CR54","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1109\/JPROC.2022.3149785","volume":"110","author":"PH Charlton","year":"2022","unstructured":"Charlton, P. H., P. A. Kyriaco, J. Mant, V. Marozas, P. Chowienczyk, and J. Alastruey. Wearable photoplethysmography for cardiovascular disease detection: fundamentals, features, and prospects. Proc. IEEE. 110(4):642\u2013667, 2022. https:\/\/doi.org\/10.1109\/JPROC.2022.3149785.","journal-title":"Proc. IEEE"},{"key":"4297_CR55","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1038\/s41569-021-00522-7","volume":"18","author":"K Bayoumy","year":"2021","unstructured":"Bayoumy, K., M. Gaber, A. Elshafeey, O. Mhaimeed, E. H. Dineen, F. A. Marvel, S. S. Martin, E. D. Muse, M. P. Turakhia, K. G. Tarakji, and M. B. Elshazly. Smart wearable devices in cardiovascular care: where we are and how to move forward. Nat. Rev. Cardiol. 18:581\u2013599, 2021. https:\/\/doi.org\/10.1038\/s41569-021-00522-7.","journal-title":"Nat. Rev. Cardiol."},{"key":"4297_CR56","doi-asserted-by":"publisher","unstructured":"Fine, J., K. L. Branan, A. J. Rodriguez, T. Boonya-Ananta, Ajmal, J. C. Ramella-Roman, M. J. McShane, and G. L. Cot\u00e9. Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring. Biosensors 11(4):126, 2021 https:\/\/doi.org\/10.3390\/bios11040126.","DOI":"10.3390\/bios11040126"},{"issue":"25","key":"4297_CR57","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.1056\/NEJMc2029240","volume":"383","author":"MW Sjoding","year":"2020","unstructured":"Sjoding, M. W., R. P. Dickson, T. J. Iwashyna, S. E. Gay, and T. S. Valley. Racial bias in pulse oximetry measurement. N. Engl. J. Med. 383(25):2477\u20132478, 2020. https:\/\/doi.org\/10.1056\/NEJMc2029240.","journal-title":"N. Engl. J. Med."},{"key":"4297_CR58","doi-asserted-by":"publisher","first-page":"693926","DOI":"10.3389\/fmed.2021.693926","volume":"8","author":"E Kachel","year":"2021","unstructured":"Kachel, E., N. Constantini, C. Carasso, L. Littman, E. Eisenkraft, and G. Gepner. A pilot study of blood pressure monitoring after cardiac surgery using PPG-based devices. Front. Med. 8:693926, 2021. https:\/\/doi.org\/10.3389\/fmed.2021.693926.","journal-title":"Front. Med."},{"issue":"4","key":"4297_CR59","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1007\/s10544-013-9768-6","volume":"15","author":"M Theodor","year":"2013","unstructured":"Theodor, M., D. Ruh, A. Seifert, P. Ruther, U. Morgner, and J. Haueisen. Subcutaneous blood pressure monitoring with an implantable optical sensor. Biomed. Microdevices. 15(4):811\u2013820, 2013. https:\/\/doi.org\/10.1007\/s10544-013-9768-6.","journal-title":"Biomed. Microdevices"},{"issue":"3","key":"4297_CR60","doi-asserted-by":"publisher","first-page":"0873","DOI":"10.1126\/sciadv.aaw0873","volume":"5","author":"H Zhang","year":"2019","unstructured":"Zhang, H., P. Gutruf, K. Meacham, M. C. Montana, X. Zhao, A. M. Chiarelli, A. V\u00e1zquez-Guardado, A. Norris, L. Lu, Q. Guo, C. Xu, Y. Wu, H. Zhao, X. Ning, W. Bai, I. Kandela, C. R. Haney, D. Chanda, R. W. Gereau, and J. A. Rogers. Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry. Sci. Adv. 5(3):0873, 2019. https:\/\/doi.org\/10.1126\/sciadv.aaw0873.","journal-title":"Sci. Adv."},{"issue":"2","key":"4297_CR61","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1007\/s44174-022-00057-6","volume":"1","author":"JG Troughton","year":"2023","unstructured":"Troughton, J. G., P. Brige, and M. Ramuz. Flexible, implantable, pulse oximetry sensors: toward long-term monitoring of blood oxygen saturations. Biomed. Mater. Devices. 1(2):912\u2013924, 2023. https:\/\/doi.org\/10.1007\/s44174-022-00057-6.","journal-title":"Biomed. Mater. Devices"},{"issue":"5","key":"4297_CR62","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.3390\/s19051013","volume":"19","author":"P Mehrotra","year":"2019","unstructured":"Mehrotra, P., B. Chatterjee, and S. Sen. EM-wave biosensors: a review of RF, microwave, mm-wave and optical sensing. Sensors. 19(5):1013, 2019. https:\/\/doi.org\/10.3390\/s19051013.","journal-title":"Sensors"},{"issue":"3","key":"4297_CR63","doi-asserted-by":"publisher","first-page":"10","DOI":"10.4018\/IJMHCI.2018070102","volume":"10","author":"G Shaker","year":"2018","unstructured":"Shaker, G., K. Smith, A. E. Omer, S. Liu, C. Csech, U. Wadhwa, S. Safavi-Naeini, and R. Hughson. Non-invasive monitoring of glucose level changes utilizing a mm-wave radar system. Int. J. Mob. Hum.\u2013Comput. Interact. 10(3):10\u201329, 2018. https:\/\/doi.org\/10.4018\/IJMHCI.2018070102.","journal-title":"Int. J. Mob. Hum.\u2013Comput. Interact."},{"issue":"1","key":"4297_CR64","doi-asserted-by":"publisher","first-page":"17395","DOI":"10.1038\/s41598-022-22128-w","volume":"12","author":"S Kim","year":"2022","unstructured":"Kim, S., J. Malik, J. M. Seo, Y. M. Cho, and F. Bien. Subcutaneously implantable electromagnetic biosensor system for continuous glucose monitoring. Sci. Rep. 12(1):17395, 2022. https:\/\/doi.org\/10.1038\/s41598-022-22128-w.","journal-title":"Sci. Rep."},{"issue":"3","key":"4297_CR65","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1109\/TBME.2022.3207240","volume":"70","author":"J Malik","year":"2023","unstructured":"Malik, J., S. Kim, J. M. Seo, Y. M. Cho, and F. Bien. Minimally invasive implant type electromagnetic biosensor for continuous glucose monitoring system: in vivo evaluation. IEEE Trans. Biomed. Eng. 70(3):1000\u20131011, 2023. https:\/\/doi.org\/10.1109\/TBME.2022.3207240.","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"12","key":"4297_CR66","doi-asserted-by":"publisher","first-page":"2400068","DOI":"10.1002\/adsr.202400068","volume":"3","author":"KL Peterson","year":"2024","unstructured":"Peterson, K. L., R. P. Shukla, and M. A. Daniele. Percutaneous wearable biosensors: a brief history and systems perspective. Adv. Sens. Res. 3(12):2400068, 2024. https:\/\/doi.org\/10.1002\/adsr.202400068.","journal-title":"Adv. Sens. Res."},{"key":"4297_CR67","doi-asserted-by":"publisher","first-page":"113054","DOI":"10.1016\/j.bios.2021.113054","volume":"181","author":"I Lee","year":"2021","unstructured":"Lee, I., D. Probst, D. Klonoff, and K. Sode. Continuous glucose monitoring systems\u2014current status and future perspectives of the flagship technologies in biosensor research. Biosens. Bioelectron. 181:113054, 2021. https:\/\/doi.org\/10.1016\/j.bios.2021.113054.","journal-title":"Biosens. Bioelectron."},{"key":"4297_CR68","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1038\/s41551-022-00998-9","volume":"7","author":"M Friedel","year":"2023","unstructured":"Friedel, M., I. A. P. Thompson, G. Kasting, R. Polsky, D. Cunningham, H. T. Soh, and J. Heikenfeld. Opportunities and challenges in the diagnostic utility of dermal interstitial fluid. Nat. Biomed. Eng. 7:1541\u20131555, 2023. https:\/\/doi.org\/10.1038\/s41551-022-00998-9.","journal-title":"Nat. Biomed. Eng."},{"issue":"2","key":"4297_CR69","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1089\/dia.2021.0182","volume":"24","author":"SK Garg","year":"2022","unstructured":"Garg, S. K., D. R. Liljenquist, B. W. Bode, M. P. Christiansen, T. S. Bailey, R. L. Brazg, D. S. Denham, A. R. Chang, H. K. Akturk, A. Dehennis, K. S. Tweden, and F. R. Kaufman. Evaluation of accuracy and safety of the next-generation up to 180-day long-term implantable Eversense continuous glucose monitoring system: the PROMISE study. Diabetes Technol. Ther. 24(2):84\u201392, 2022. https:\/\/doi.org\/10.1089\/dia.2021.0182.","journal-title":"Diabetes Technol. Ther."},{"issue":"1","key":"4297_CR70","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.bmc.2004.09.058","volume":"13","author":"R Badugu","year":"2005","unstructured":"Badugu, R., J. R. Lakowicz, and C. D. Geddes. Boronic acid fluorescent sensors for monosaccharide signaling based on the 6-methoxyquinolinium heterocyclic nucleus: progress toward noninvasive and continuous glucose monitoring. Bioorg. Med. Chem. 13(1):113\u2013119, 2005. https:\/\/doi.org\/10.1016\/j.bmc.2004.09.058.","journal-title":"Bioorg. Med. Chem."},{"issue":"1","key":"4297_CR71","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1177\/1932296820911919","volume":"15","author":"JI Joseph","year":"2021","unstructured":"Joseph, J. I. Review of the long-term implantable Senseonics continuous glucose monitoring system and other continuous glucose monitoring systems. J. Diabetes Sci. Technol. 15(1):167\u2013173, 2021. https:\/\/doi.org\/10.1177\/1932296820911919.","journal-title":"J. Diabetes Sci. Technol."},{"key":"4297_CR72","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.bios.2014.05.022","volume":"61","author":"M Mortellaro","year":"2014","unstructured":"Mortellaro, M., A. DeHennis, et al. Performance characterization of an abiotic and fluorescent-based continuous glucose monitoring system in patients with type 1 diabetes. Biosens. Bioelectron. 61:227\u2013231, 2014. https:\/\/doi.org\/10.1016\/j.bios.2014.05.022.","journal-title":"Biosens. Bioelectron."},{"issue":"33","key":"4297_CR73","doi-asserted-by":"publisher","first-page":"13399","DOI":"10.1073\/pnas.1104954108","volume":"108","author":"YJ Heo","year":"2011","unstructured":"Heo, Y. J., H. Shibata, T. Okitsu, T. Kawanishi, and S. Takeuchi. Long-term in vivo glucose monitoring using fluorescent hydrogel fibers. Proc. Natl Acad. Sci. USA. 108(33):13399\u201313403, 2011. https:\/\/doi.org\/10.1073\/pnas.1104954108.","journal-title":"Proc. Natl Acad. Sci. USA"},{"issue":"437","key":"4297_CR74","doi-asserted-by":"publisher","first-page":"8562","DOI":"10.1126\/scitranslmed.aap8562","volume":"10","author":"A Tastanova","year":"2018","unstructured":"Tastanova, A., M. Folcher, M. M\u00fcller, G. Camenisch, A. Ponti, T. Horn, M. S. Tikhomirova, and M. Fussenegger. Synthetic biology-based cellular biomedical tattoo for detection of hypercalcemia associated with cancer. Sci. Transl. Med. 10(437):8562, 2018. https:\/\/doi.org\/10.1126\/scitranslmed.aap8562.","journal-title":"Sci. Transl. Med."},{"issue":"6","key":"4297_CR75","doi-asserted-by":"publisher","first-page":"3964","DOI":"10.1021\/acsabm.4c00336","volume":"7","author":"D Chimene","year":"2024","unstructured":"Chimene, D., W. Saleem, N. Longbottom, B. Ko, A. S. Jeevarathinam, S. Horn, and M. J. McShane. Long-term evaluation of inserted nanocomposite hydrogel-based phosphorescent oxygen biosensors: evolution of local tissue oxygen levels and foreign body response. ACS Appl. Bio Mater. 7(6):3964\u20133980, 2024. https:\/\/doi.org\/10.1021\/acsabm.4c00336.","journal-title":"ACS Appl. Bio Mater."},{"issue":"11","key":"4297_CR76","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1038\/nnano.2013.222","volume":"8","author":"NM Iverson","year":"2013","unstructured":"Iverson, N. M., P. W. Barone, M. Shandell, L. J. Trudel, S. Sen, F. Sen, V. Ivanov, E. Atolia, E. Farias, T. P. McNicholas, N. Reuel, N. M. A. Parry, G. N. Wogan, and M. S. Strano. In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes. Nat. Nanotechnol. 8(11):873\u2013880, 2013. https:\/\/doi.org\/10.1038\/nnano.2013.222.","journal-title":"Nat. Nanotechnol."},{"issue":"1","key":"4297_CR77","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1146\/annurev-bioeng-110222-101045","volume":"26","author":"D Chimene","year":"2024","unstructured":"Chimene, D., K. M. K. Queener, B. S. Ko, M. McShane, and M. Daniele. Insertable biosensors: combining implanted sensing materials with wearable monitors. Annu. Rev. Biomed. Eng. 26(1):197\u2013221, 2024. https:\/\/doi.org\/10.1146\/annurev-bioeng-110222-101045.","journal-title":"Annu. Rev. Biomed. Eng."},{"issue":"6","key":"4297_CR78","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1016\/j.jvs.2014.12.060","volume":"61","author":"MF Montero-Baker","year":"2015","unstructured":"Montero-Baker, M. F., A. R. Schmidt, J. L. Zunzunegui, J. L. Mills, and D. G. Armstrong. The first-in-man Si Se Puede study for the use of micro-oxygen sensors (MOXYs) to determine dynamic relative oxygen indices in the feet of patients with limb-threatening ischemia during endovascular therapy. J. Vasc. Surg. 61(6):1501\u20131509, 2015. https:\/\/doi.org\/10.1016\/j.jvs.2014.12.060.","journal-title":"J. Vasc. Surg."},{"key":"4297_CR79","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.aca.2018.10.032","volume":"1056","author":"SC Kanick","year":"2019","unstructured":"Kanick, S. C., C. Wang, R. McCombie, et al. Continuous monitoring of interstitial tissue oxygen using subcutaneous microsensors. Anal. Chim. Acta. 1056:174\u2013184, 2019. https:\/\/doi.org\/10.1016\/j.aca.2018.10.032.","journal-title":"Anal. Chim. Acta"},{"issue":"11","key":"4297_CR80","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.hrcr.2017.07.012","volume":"3","author":"MW Preminger","year":"2017","unstructured":"Preminger, M. W., D. L. Musat, T. Sichrovsky, A. G. Bhatt, and S. Mittal. Migration of an implantable loop recorder into the pleural space. HeartRhythm Case Rep. 3(11):539\u2013541, 2017. https:\/\/doi.org\/10.1016\/j.hrcr.2017.07.012.","journal-title":"HeartRhythm Case Rep."},{"issue":"6","key":"4297_CR81","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1093\/ehjcr\/ytaf259","volume":"9","author":"N Verlinde","year":"2025","unstructured":"Verlinde, N., J. Van Keer, and R. Beelen. Implantable loop recorder migration as cause of unexplained chronic chest pain. Eur. Heart J. Case Rep. 9(6):259, 2025. https:\/\/doi.org\/10.1093\/ehjcr\/ytaf259.","journal-title":"Eur. Heart J. Case Rep."},{"key":"4297_CR82","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/978-3-319-18603-0_6","volume-title":"Immune Responses to Biosurfaces","author":"M Kastellorizios","year":"2015","unstructured":"Kastellorizios, M., N. Tipnis, and D. J. Burgess. Foreign body reaction to subcutaneous implants. In: Immune Responses to Biosurfaces, Vol. 865, edited by J. D. Lambris, K. N. Ekdahl, D. Ricklin, and B. Nilsson. Cham: Springer, 2015, pp. 93\u2013108. https:\/\/doi.org\/10.1007\/978-3-319-18603-0_6."},{"issue":"8","key":"4297_CR83","doi-asserted-by":"publisher","first-page":"1800112","DOI":"10.1002\/mabi.201800112","volume":"18","author":"G Zhou","year":"2018","unstructured":"Zhou, G., and T. Groth. Host responses to biomaterials and anti-inflammatory design\u2014a brief review. Macromol. Biosci. 18(8):1800112, 2018. https:\/\/doi.org\/10.1002\/mabi.201800112.","journal-title":"Macromol. Biosci."},{"key":"4297_CR84","unstructured":"Neely, C. M., and A. Jayaprakash. Anti-migration features for implantable medical devices. U.S. Patent Application US20210121607A1, 2021. https:\/\/patents.google.com\/patent\/US20210121607A1\/en."},{"key":"4297_CR85","unstructured":"Avidity Science. BMDS Transponder: Control and Monitoring. Avidity Science, 2025) https:\/\/www.avidityscience.com\/control-monitoring\/bmds\/transponder."},{"issue":"12","key":"4297_CR86","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/j.hrthm.2017.09.001","volume":"14","author":"FM Kusumoto","year":"2017","unstructured":"Kusumoto, F. M., M. H. Schoenfeld, B. L. Wilkoff, C. I. Berul, U. M. Birgersdotter-Green, R. Carrillo, Y.-M. Cha, J. Clancy, J.-C. Deharo, K. A. Ellenbogen, D. Exner, A. A. Hussein, C. Kennergren, A. Krahn, R. Lee, C. J. Love, R. A. Madden, H. Mazzetti, J. C. Moore, V. Parsonnet, K. K. Patton, M. A. Rozner, C. H. Selzman, M. Shoda, K. Srivathsan, N. Strathmore, C. D. Swerdlow, C. Tompkins, and O. Wazni. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 14(12):503\u2013551, 2017. https:\/\/doi.org\/10.1016\/j.hrthm.2017.09.001.","journal-title":"Heart Rhythm"},{"issue":"3","key":"4297_CR87","doi-asserted-by":"publisher","first-page":"2307288","DOI":"10.1002\/adma.202307288","volume":"36","author":"M Singh","year":"2024","unstructured":"Singh, M., D. L. Teodorescu, M. Rowlett, S. X. Wang, M. Balcells, C. Park, B. Bernardo, S. McGarel, C. Reeves, M. R. Mehra, X. Zhao, H. Yuk, and E. T. Roche. A tunable soft silicone bioadhesive for secure anchoring of diverse medical devices to wet biological tissue. Adv. Mater. 36(3):2307288, 2024. https:\/\/doi.org\/10.1002\/adma.202307288.","journal-title":"Adv. Mater."},{"issue":"2","key":"4297_CR88","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1515\/cdbme-2017-0153","volume":"3","author":"S Winkler","year":"2017","unstructured":"Winkler, S., J. Edelmann, C. Welsch, and R. Ruff. Different encapsulation strategies for implanted electronics: comparison of titanium, ceramic and silicone material for implant body. Curr. Dir. Biomed. Eng. 3(2):725\u2013728, 2017. https:\/\/doi.org\/10.1515\/cdbme-2017-0153.","journal-title":"Curr. Dir. Biomed. Eng."},{"issue":"3","key":"4297_CR89","doi-asserted-by":"publisher","first-page":"2001397","DOI":"10.1002\/adhm.202001397","volume":"10","author":"B Llerena Zambrano","year":"2021","unstructured":"Llerena Zambrano, B., A. F. Renz, T. Ruff, S. Lienemann, K. Tybrandt, J. V\u00f6r\u00f6s, and J. Lee. Soft electronics based on stretchable and conductive nanocomposites for biomedical applications. Adv. Healthc. Mater. 10(3):2001397, 2021. https:\/\/doi.org\/10.1002\/adhm.202001397.","journal-title":"Adv. Healthc. Mater."},{"key":"4297_CR90","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/j.matlet.2017.06.069","volume":"205","author":"X Li","year":"2017","unstructured":"Li, X., D. Zhang, and Y. Chen. Silicone rubber\/hollow silica spheres composites with enhanced mechanical and electrical insulating performances. Mater. Lett. 205:240\u2013244, 2017. https:\/\/doi.org\/10.1016\/j.matlet.2017.06.069.","journal-title":"Mater. Lett."},{"issue":"6","key":"4297_CR91","doi-asserted-by":"publisher","first-page":"1566","DOI":"10.1039\/C8CS00706C","volume":"48","author":"S Choi","year":"2019","unstructured":"Choi, S., S. I. Han, D. Kim, T. Hyeon, and D.-H. Kim. High-performance stretchable conductive nanocomposites: materials, processes, and device applications. Chem. Soc. Rev. 48(6):1566\u20131595, 2019. https:\/\/doi.org\/10.1039\/C8CS00706C.","journal-title":"Chem. Soc. Rev."},{"issue":"23","key":"4297_CR92","doi-asserted-by":"publisher","first-page":"11174","DOI":"10.1021\/acs.nanolett.3c03670","volume":"23","author":"Y Lin","year":"2023","unstructured":"Lin, Y., T. Fang, C. Bai, Y. Sun, C. Yang, G. Hu, H. Guo, W. Qiu, W. Huang, L. Wang, Z. Tao, Y.-Q. Lu, and D. Kong. Ultrastretchable electrically self-healing conductors based on silver nanowire\/liquid metal microcapsule nanocomposites. Nano Lett. 23(23):11174\u201311183, 2023. https:\/\/doi.org\/10.1021\/acs.nanolett.3c03670.","journal-title":"Nano Lett."},{"issue":"16","key":"4297_CR93","doi-asserted-by":"publisher","first-page":"2630","DOI":"10.3390\/polym13162630","volume":"13","author":"H-S Kim","year":"2021","unstructured":"Kim, H.-S., S. Kim, B.-H. Shin, C.-Y. Heo, O. Faruq, L. T. Van Anh, N. D\u00f6nmez, P. N. Chien, D.-S. Shin, S.-Y. Nam, and R.-M. Baek. Silicone implants immobilized with interleukin-4 promote the M2 polarization of macrophages and inhibit the formation of fibrous capsules. Polymers. 13(16):2630, 2021. https:\/\/doi.org\/10.3390\/polym13162630.","journal-title":"Polymers"},{"issue":"2","key":"4297_CR94","doi-asserted-by":"publisher","first-page":"026006","DOI":"10.1088\/1741-2560\/13\/2\/026006","volume":"13","author":"JJ FitzGerald","year":"2016","unstructured":"FitzGerald, J. J. Suppression of scarring in peripheral nerve implants by drug elution. J. Neural Eng. 13(2):026006, 2016. https:\/\/doi.org\/10.1088\/1741-2560\/13\/2\/026006.","journal-title":"J. Neural Eng."},{"issue":"2","key":"4297_CR95","doi-asserted-by":"publisher","first-page":"02-419","DOI":"10.1116\/1.4989835","volume":"12","author":"ML Sylvester","year":"2017","unstructured":"Sylvester, M. L., and B. D. Ratner. Collagen affinity coating for surface binding of decorin and other biomolecules: surface characterization. Biointerphases. 12(2):02\u2013419, 2017. https:\/\/doi.org\/10.1116\/1.4989835.","journal-title":"Biointerphases"},{"issue":"10","key":"4297_CR96","doi-asserted-by":"publisher","first-page":"3126","DOI":"10.3390\/molecules27103126","volume":"27","author":"M Gori","year":"2022","unstructured":"Gori, M., S. M. Giannitelli, G. Vadal\u00e0, R. Papalia, L. Zollo, M. Sanchez, M. Trombetta, A. Rainer, G. Di Pino, and V. Denaro. A soft zwitterionic hydrogel as potential coating on a polyimide surface to reduce foreign body reaction to intraneural electrodes. Molecules. 27(10):3126, 2022. https:\/\/doi.org\/10.3390\/molecules27103126.","journal-title":"Molecules"},{"issue":"28","key":"4297_CR97","doi-asserted-by":"publisher","first-page":"33300","DOI":"10.1021\/acsami.1c10121","volume":"13","author":"MT Matter","year":"2021","unstructured":"Matter, M. T., L. Maliqi, K. Keevend, S. Guimond, J. Ng, E. Armagan, M. Rottmar, and I. K. Herrmann. One-step synthesis of versatile antimicrobial nano-architected implant coatings for hard and soft tissue healing. ACS Appl. Mater. Interfaces. 13(28):33300\u201333310, 2021. https:\/\/doi.org\/10.1021\/acsami.1c10121.","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"7","key":"4297_CR98","doi-asserted-by":"publisher","first-page":"9685","DOI":"10.1021\/acsami.1c19579","volume":"14","author":"SK Divakarla","year":"2022","unstructured":"Divakarla, S. K., T. Das, C. Chatterjee, M. Ionescu, Z. Pastuovic, J.-H. Jang, H. Al-khoury, H. Loppnow, S. Yamaguchi, T. Groth, and W. Chrzanowski. Antimicrobial and anti-inflammatory gallium-defensin surface coatings for implantable devices. ACS Appl. Mater. Interfaces. 14(7):9685\u20139696, 2022. https:\/\/doi.org\/10.1021\/acsami.1c19579.","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"6","key":"4297_CR99","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1149\/06906.0015ecst","volume":"69","author":"J-C Souriau","year":"2015","unstructured":"Souriau, J.-C., J. M. Herrera Morales, L. Castagn\u00e9, G. Simon, K. Amara, and B. Boutaud. Miniaturization and biocompatible encapsulation for implantable biomedical silicon devices. ECS Trans. 69(6):15\u201324, 2015. https:\/\/doi.org\/10.1149\/06906.0015ecst.","journal-title":"ECS Trans."},{"key":"4297_CR100","doi-asserted-by":"publisher","DOI":"10.1515\/bmt-2012-4292","author":"W Betz","year":"2012","unstructured":"Betz, W., H. K. Trieu, and H. Vogt. Microelectromechanical implants: encapsulation concepts and test procedures (SI-1 Track-D). Biomed. Eng.\/Biomed. Tech. 2012. https:\/\/doi.org\/10.1515\/bmt-2012-4292.","journal-title":"Biomed. Eng.\/Biomed. Tech."},{"key":"4297_CR101","doi-asserted-by":"publisher","DOI":"10.5772\/55308","volume-title":"Advances in Micro\/Nano Electromechanical Systems and Fabrication Technologies","author":"DC Rodger","year":"2013","unstructured":"Rodger, D. C., W. Li, J. D. Weiland, M. S. Humayun, and Y.-C. Tai. Flexible circuit technologies for biomedical applications. In: Advances in Micro\/Nano Electromechanical Systems and Fabrication Technologies, edited by K. Takahata. Rijeka: InTech, 2013. https:\/\/doi.org\/10.5772\/55308."},{"issue":"34","key":"4297_CR102","doi-asserted-by":"publisher","first-page":"2201129","DOI":"10.1002\/adma.202201129","volume":"34","author":"M Mariello","year":"2022","unstructured":"Mariello, M., K. Kim, K. Wu, S. P. Lacour, and Y. Leterrier. Recent advances in encapsulation of flexible bioelectronic implants: materials, technologies, and characterization methods. Adv. Mater. 34(34):2201129, 2022. https:\/\/doi.org\/10.1002\/adma.202201129.","journal-title":"Adv. Mater."},{"issue":"3","key":"4297_CR103","doi-asserted-by":"publisher","first-page":"031502","DOI":"10.1063\/1.5063657","volume":"7","author":"C Lim","year":"2019","unstructured":"Lim, C., Y. Shin, J. Jung, J. H. Kim, S. Lee, and D.-H. Kim. Stretchable conductive nanocomposite based on alginate hydrogel and silver nanowires for wearable electronics. APL Mater. 7(3):031502, 2019. https:\/\/doi.org\/10.1063\/1.5063657.","journal-title":"APL Mater."},{"issue":"12","key":"4297_CR104","doi-asserted-by":"publisher","first-page":"3287","DOI":"10.1002\/jbm.a.34274","volume":"100A","author":"JH Kim","year":"2012","unstructured":"Kim, J. H., C. H. Park, O.-J. Lee, J.-M. Lee, J. W. Kim, Y. H. Park, and C. S. Ki. Preparation and in vivo degradation of controlled biodegradability of electrospun silk fibroin nanofiber mats. J. Biomed. Mater. Res. A. 100A(12):3287\u20133295, 2012. https:\/\/doi.org\/10.1002\/jbm.a.34274.","journal-title":"J. Biomed. Mater. Res. A"},{"key":"4297_CR105","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.biomaterials.2015.08.039","volume":"71","author":"AE Thurber","year":"2015","unstructured":"Thurber, A. E., F. G. Omenetto, and D. L. Kaplan. In vivo bioresponses to silk proteins. Biomaterials. 71:145\u2013157, 2015. https:\/\/doi.org\/10.1016\/j.biomaterials.2015.08.039.","journal-title":"Biomaterials"},{"issue":"33","key":"4297_CR106","doi-asserted-by":"publisher","first-page":"42745","DOI":"10.1021\/acsami.4c10541","volume":"16","author":"Y Lin","year":"2024","unstructured":"Lin, Y., H. Wang, W. Qiu, T. Fang, C. Bai, Y. Sun, W. Li, Z. Liu, C. Majidi, Y. Zhang, M. D. Dickey, L. Jiang, and W. Cheng. Liquid metal-based self-healing conductors for flexible and stretchable electronics. ACS Appl. Mater. Interfaces. 16(33):42745\u201342762, 2024. https:\/\/doi.org\/10.1021\/acsami.4c10541.","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"10","key":"4297_CR107","doi-asserted-by":"publisher","first-page":"1892","DOI":"10.2337\/db19-0229","volume":"68","author":"PM McClatchey","year":"2019","unstructured":"McClatchey, P. M., E. S. McClain, I. M. Williams, C. M. Malabanan, F. D. James, P. C. Lord, J. M. Gregory, D. E. Cliffel, and D. H. Wasserman. Fibrotic encapsulation is the dominant source of continuous glucose monitor delays. Diabetes. 68(10):1892\u20131901, 2019. https:\/\/doi.org\/10.2337\/db19-0229.","journal-title":"Diabetes"},{"issue":"3","key":"4297_CR108","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1177\/193229681100500317","volume":"5","author":"KL Helton","year":"2011","unstructured":"Helton, K. L., B. D. Ratner, and N. A. Wisniewski. Biomechanics of the sensor\u2013tissue interface\u2014effects of motion, pressure, and design on sensor performance and the foreign body response\u2014Part I: theoretical framework. J. Diabetes Sci. Technol. 5(3):632\u2013646, 2011. https:\/\/doi.org\/10.1177\/193229681100500317.","journal-title":"J. Diabetes Sci. Technol."},{"issue":"3","key":"4297_CR109","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1177\/193229681100500318","volume":"5","author":"KL Helton","year":"2011","unstructured":"Helton, K. L., B. D. Ratner, and N. A. Wisniewski. Biomechanics of the sensor\u2013tissue interface\u2014effects of motion, pressure, and design on sensor performance and foreign body response\u2014Part II: examples and application. J. Diabetes Sci. Technol. 5(3):647\u2013656, 2011. https:\/\/doi.org\/10.1177\/193229681100500318.","journal-title":"J. Diabetes Sci. Technol."},{"issue":"1","key":"4297_CR110","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1038\/s44385-025-00053-7","volume":"3","author":"ME Dickenson","year":"2026","unstructured":"Dickenson, M. E., R. S. Oakes, and A. H. Morris. Don\u2019t judge an implant by its cover: how the foreign body response and fibrotic capsule might be harnessed for good. NPJ Biomed. Innov. 3(1):3, 2026. https:\/\/doi.org\/10.1038\/s44385-025-00053-7.","journal-title":"NPJ Biomed. Innov."},{"issue":"6","key":"4297_CR111","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1177\/193229680800200628","volume":"2","author":"AW Bridges","year":"2008","unstructured":"Bridges, A. W., and A. J. Garc\u00eda. Anti-inflammatory polymeric coatings for implantable biomaterials and devices. J. Diabetes Sci. Technol. 2(6):984\u2013994, 2008. https:\/\/doi.org\/10.1177\/193229680800200628.","journal-title":"J. Diabetes Sci. Technol."},{"issue":"4","key":"4297_CR112","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1177\/193229680700100407","volume":"1","author":"U Klueh","year":"2007","unstructured":"Klueh, U., M. Kaur, D. C. Montrose, and D. L. Kreutzer. Inflammation and glucose sensors: use of dexamethasone to extend glucose sensor function and life span in vivo. J. Diabetes Sci. Technol. 1(4):496\u2013504, 2007. https:\/\/doi.org\/10.1177\/193229680700100407.","journal-title":"J. Diabetes Sci. Technol."},{"key":"4297_CR113","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.actbio.2015.10.045","volume":"30","author":"SG Vallejo-Heligon","year":"2016","unstructured":"Vallejo-Heligon, S. G., N. L. Brown, W. M. Reichert, and B. Klitzman. Porous, dexamethasone-loaded polyurethane coatings extend performance window of implantable glucose sensors in vivo. Acta Biomater. 30:106\u2013115, 2016. https:\/\/doi.org\/10.1016\/j.actbio.2015.10.045.","journal-title":"Acta Biomater."},{"issue":"1","key":"4297_CR114","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1002\/jbm.a.32512","volume":"93A","author":"YM Ju","year":"2010","unstructured":"Ju, Y. M., B. Yu, L. West, Y. Moussy, and F. Moussy. A dexamethasone-loaded PLGA microspheres\/collagen scaffold composite for implantable glucose sensors. J. Biomed. Mater. Res. A. 93A(1):200\u2013210, 2010. https:\/\/doi.org\/10.1002\/jbm.a.32512.","journal-title":"J. Biomed. Mater. Res. A"},{"issue":"1","key":"4297_CR115","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1186\/s12951-023-01873-8","volume":"21","author":"MA Lee","year":"2023","unstructured":"Lee, M. A., X. Jin, S. Muthupalani, N. A. Bakh, X. Gong, and M. S. Strano. In-vivo fluorescent nanosensor implants based on hydrogel-encapsulation: investigating the inflammation and the foreign-body response. J. Nanobiotechnol. 21(1):133, 2023. https:\/\/doi.org\/10.1186\/s12951-023-01873-8.","journal-title":"J. Nanobiotechnol."},{"issue":"1","key":"4297_CR116","doi-asserted-by":"publisher","first-page":"11105","DOI":"10.1038\/srep11105","volume":"5","author":"D Wu","year":"2015","unstructured":"Wu, D., X. Chen, T. Chen, C. Ding, W. Wu, and J. Li. Substrate-anchored and degradation-sensitive anti-inflammatory coatings for implant materials. Sci. Rep. 5(1):11105, 2015. https:\/\/doi.org\/10.1038\/srep11105.","journal-title":"Sci. Rep."},{"issue":"12","key":"4297_CR117","doi-asserted-by":"publisher","first-page":"01067","DOI":"10.1016\/j.heliyon.2018.e01067","volume":"4","author":"Z Khatoon","year":"2018","unstructured":"Khatoon, Z., C. D. McTiernan, E. J. Suuronen, T.-F. Mah, and E. I. Alarcon. Bacterial biofilm formation on implantable devices and approaches to its treatment and prevention. Heliyon. 4(12):01067, 2018. https:\/\/doi.org\/10.1016\/j.heliyon.2018.e01067.","journal-title":"Heliyon"},{"issue":"2","key":"4297_CR118","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1002\/app.31119","volume":"115","author":"P Kaali","year":"2010","unstructured":"Kaali, P., D. Momcilovic, A. Markstr\u00f6m, R. E. Aune, G. Czel, and S. Karlsson. Degradation of biomedical polydimethylsiloxanes during exposure to in vivo biofilm environment monitored by FE-SEM, ATR-FTIR, and MALDI-TOF MS. J. Appl. Polym. Sci. 115(2):802\u2013810, 2010. https:\/\/doi.org\/10.1002\/app.31119.","journal-title":"J. Appl. Polym. Sci."},{"issue":"48","key":"4297_CR119","doi-asserted-by":"publisher","first-page":"53646","DOI":"10.1021\/acsami.0c14668","volume":"12","author":"KWJ Verhorstert","year":"2020","unstructured":"Verhorstert, K. W. J., Z. Guler, L. Boer, M. Riool, J.-P.W.R. Roovers, and S. A. J. Zaat. In vitro bacterial adhesion and biofilm formation on fully absorbable poly-4-hydroxybutyrate and nonabsorbable polypropylene pelvic floor implants. ACS Appl. Mater. Interfaces. 12(48):53646\u201353653, 2020. https:\/\/doi.org\/10.1021\/acsami.0c14668.","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"12","key":"4297_CR120","doi-asserted-by":"publisher","first-page":"6057","DOI":"10.1021\/ac501203n","volume":"86","author":"C Hou","year":"2014","unstructured":"Hou, C., D. Yang, B. Liang, and A. Liu. Enhanced performance of a glucose\/O$$_{2}$$ biofuel cell assembled with laccase-covalently immobilized three-dimensional macroporous gold film-based biocathode and bacterial surface displayed glucose dehydrogenase-based bioanode. Anal. Chem. 86(12):6057\u20136063, 2014. https:\/\/doi.org\/10.1021\/ac501203n.","journal-title":"Anal. Chem."},{"issue":"8","key":"4297_CR121","doi-asserted-by":"publisher","first-page":"12475","DOI":"10.1021\/acsnano.1c03614","volume":"15","author":"L Sun","year":"2021","unstructured":"Sun, L., C. Cheng, S. Wang, J. Tang, R. Xie, and D. Wang. Bioinspired, nanostructure-amplified, subcutaneous light harvesting to power implantable biomedical electronics. ACS Nano. 15(8):12475\u201312482, 2021. https:\/\/doi.org\/10.1021\/acsnano.1c03614.","journal-title":"ACS Nano"},{"issue":"16","key":"4297_CR122","doi-asserted-by":"publisher","first-page":"14656","DOI":"10.1021\/acsanm.3c01973","volume":"6","author":"\u00d6 Faruk \u00dcnsal","year":"2023","unstructured":"Faruk \u00dcnsal, \u00d6., and A. \u00c7elik Bedelo\u011flu. Three-dimensional piezoelectric\u2013triboelectric hybrid nanogenerators for mechanical energy harvesting. ACS Appl. Nano Mater. 6(16):14656\u201314668, 2023. https:\/\/doi.org\/10.1021\/acsanm.3c01973.","journal-title":"ACS Appl. Nano Mater."},{"key":"4297_CR123","doi-asserted-by":"publisher","unstructured":"Kim, J., D.-H. Kim, and Y.-J. Park. Effective magnetic resonant wireless power transfer system over medium range using an intermediate resonant coil of two loops. In: 2015 IEEE-APS Topical Conference on Antennas and Propagation in Wireless Communications (APWC), 2015. Torino: IEEE, 2015, pp. 274\u2013277. https:\/\/doi.org\/10.1109\/APWC.2015.7300166.","DOI":"10.1109\/APWC.2015.7300166"},{"issue":"5","key":"4297_CR124","doi-asserted-by":"publisher","first-page":"10476","DOI":"10.1371\/journal.pone.0010476","volume":"5","author":"P Cinquin","year":"2010","unstructured":"Cinquin, P., C. Gondran, F. Giroud, S. Mazabrard, A. Pellissier, F. Boucher, J.-P. Alcaraz, K. Gorgy, F. Lenouvel, S. Math\u00e9, P. Porcu, and S. Cosnier. A glucose BioFuel cell implanted in rats. PLoS ONE. 5(5):10476, 2010. https:\/\/doi.org\/10.1371\/journal.pone.0010476.","journal-title":"PLoS ONE"},{"key":"4297_CR125","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1038\/srep01516","volume":"3","author":"A Zebda","year":"2013","unstructured":"Zebda, A., S. Cosnier, J.-P. Alcaraz, M. Holzinger, A. Le Goff, C. Gondran, F. Boucher, F. Giroud, K. Gorgy, H. Lamraoui, and P. Cinquin. Single glucose biofuel cells implanted in rats power electronic devices. Sci. Rep. 3:1516, 2013. https:\/\/doi.org\/10.1038\/srep01516.","journal-title":"Sci. Rep."},{"key":"4297_CR126","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.electacta.2018.02.156","volume":"269","author":"S El Ichi-Ribault","year":"2018","unstructured":"El Ichi-Ribault, S., J.-P. Alcaraz, F. Boucher, B. Boutaud, R. Dalmolin, J. Boutonnat, P. Cinquin, A. Zebda, and D. K. Martin. Remote wireless control of an enzymatic biofuel cell implanted in a rabbit for 2 months. Electrochim. Acta. 269:360\u2013366, 2018. https:\/\/doi.org\/10.1016\/j.electacta.2018.02.156.","journal-title":"Electrochim. Acta"},{"key":"4297_CR127","doi-asserted-by":"publisher","DOI":"10.1007\/s40243-025-00297-8","author":"S Vanmathi","year":"2025","unstructured":"Vanmathi, S., U. S. Jayapiriya, P. Sharma, O. P. Kulkarni, and S. Goel. An implantable glucose enzymatic biofuel cell integrated with flexible gold-coated carbon foam and carbon thread bioelectrodes grafted inside a living rat. Mater. Renew. Sustain. Energy. 2025. https:\/\/doi.org\/10.1007\/s40243-025-00297-8.","journal-title":"Mater. Renew. Sustain. Energy"},{"key":"4297_CR128","doi-asserted-by":"publisher","first-page":"226844","DOI":"10.1016\/j.jpowsour.2019.226844","volume":"436","author":"I Shitanda","year":"2019","unstructured":"Shitanda, I., K. Takamatsu, A. Niiyama, T. Mikawa, Y. Hoshi, M. Itagaki, and S. Tsujimura. High-power lactate\/O$$_{2}$$ enzymatic biofuel cell based on carbon cloth electrodes modified with MgO-templated carbon. J. Power Sources. 436:226844, 2019. https:\/\/doi.org\/10.1016\/j.jpowsour.2019.226844.","journal-title":"J. Power Sources"},{"key":"4297_CR129","doi-asserted-by":"publisher","unstructured":"Roxby, D. N., S.R. S. Ting, and H. T. Nguyen. Polypyrrole RVC biofuel cells for powering medical implants. In: 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2017. Seogwipo: IEEE, 2017, pp. 779\u2013782. https:\/\/doi.org\/10.1109\/EMBC.2017.8036940.","DOI":"10.1109\/EMBC.2017.8036940"},{"issue":"4","key":"4297_CR130","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1002\/elan.201600706","volume":"29","author":"A Koushanpour","year":"2017","unstructured":"Koushanpour, A., M. Gamella, N. Guz, and E. Katz. A biofuel cell based on biocatalytic reactions of glucose on both anode and cathode electrodes. Electroanalysis. 29(4):950\u2013954, 2017. https:\/\/doi.org\/10.1002\/elan.201600706.","journal-title":"Electroanalysis"},{"issue":"24","key":"4297_CR131","doi-asserted-by":"publisher","first-page":"11988","DOI":"10.1109\/JSEN.2019.2937814","volume":"19","author":"N Maleki","year":"2019","unstructured":"Maleki, N., S. Kashanian, M. Nazari, and N. Shahabadi. A novel and enhanced membrane-free performance of glucose\/O$$_{2}$$ biofuel cell, integrated with biocompatible laccase nanoflower biocathode and glucose dehydrogenase bioanode. IEEE Sens. J. 19(24):11988\u201311994, 2019. https:\/\/doi.org\/10.1109\/JSEN.2019.2937814.","journal-title":"IEEE Sens. J."},{"issue":"13","key":"4297_CR132","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1002\/adhm.201600222","volume":"5","author":"K Song","year":"2016","unstructured":"Song, K., J. H. Han, T. Lim, N. Kim, S. Shin, J. Kim, H. Choo, S. Jeong, Y.-C. Kim, Z. L. Wang, and J. Lee. Subdermal flexible solar cell arrays for powering medical electronic implants. Adv. Healthc. Mater. 5(13):1572\u20131580, 2016. https:\/\/doi.org\/10.1002\/adhm.201600222.","journal-title":"Adv. Healthc. Mater."},{"key":"4297_CR133","doi-asserted-by":"publisher","first-page":"114948","DOI":"10.1016\/j.apenergy.2020.114948","volume":"269","author":"MV Tholl","year":"2020","unstructured":"Tholl, M. V., H. G. Akar\u00e7ay, H. Tanner, T. Niederhauser, A. Zurbuchen, M. Frenz, and A. Haeberlin. Subdermal solar energy harvesting\u2014a new way to power autonomous electric implants. Appl. Energy. 269:114948, 2020. https:\/\/doi.org\/10.1016\/j.apenergy.2020.114948.","journal-title":"Appl. Energy"},{"key":"4297_CR134","doi-asserted-by":"publisher","first-page":"35801","DOI":"10.1109\/ACCESS.2018.2851940","volume":"6","author":"T Wu","year":"2018","unstructured":"Wu, T., J.-M. Redoute, and M. R. Yuce. A wireless implantable sensor design with subcutaneous energy harvesting for long-term IoT healthcare applications. IEEE Access. 6:35801\u201335808, 2018. https:\/\/doi.org\/10.1109\/ACCESS.2018.2851940.","journal-title":"IEEE Access."},{"key":"4297_CR135","doi-asserted-by":"publisher","unstructured":"Colin, C., I. Massiot, A. Cattoni, N. Vandamme, C. Dupuis, N. Bardou, I. Gerard, N. Naghavi, J.-F. Guillemoles, J.-L. Pelouard, and S. Collin. Broadband light-trapping in ultra-thin nano-structured solar cells. In: SPIE OPTO, San Francisco, California, USA, 2013, edited by A. Freundlich, and J.-F. Guillemoles, p. 86200. https:\/\/doi.org\/10.1117\/12.2004269.","DOI":"10.1117\/12.2004269"},{"issue":"17","key":"4297_CR136","doi-asserted-by":"publisher","first-page":"2000779","DOI":"10.1002\/adhm.202000779","volume":"9","author":"J Zhao","year":"2020","unstructured":"Zhao, J., R. Ghannam, K. O. Htet, Y. Liu, M.-K. Law, V. A. L. Roy, B. Michel, M. A. Imran, and H. Heidari. Self-powered implantable medical devices: photovoltaic energy harvesting review. Adv. Healthc. Mater. 9(17):2000779, 2020. https:\/\/doi.org\/10.1002\/adhm.202000779.","journal-title":"Adv. Healthc. Mater."},{"issue":"5","key":"4297_CR137","doi-asserted-by":"publisher","first-page":"1927","DOI":"10.1073\/pnas.1317233111","volume":"111","author":"C Dagdeviren","year":"2014","unstructured":"Dagdeviren, C., B. D. Yang, Y. Su, P. L. Tran, P. Joe, E. Anderson, J. Xia, V. Doraiswamy, B. Dehdashti, X. Feng, B. Lu, R. Poston, Z. Khalpey, R. Ghaffari, Y. Huang, M. J. Slepian, and J. A. Rogers. Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm. Proc. Natl Acad. Sci. USA. 111(5):1927\u20131932, 2014. https:\/\/doi.org\/10.1073\/pnas.1317233111.","journal-title":"Proc. Natl Acad. Sci. USA"},{"issue":"3","key":"4297_CR138","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1039\/C6NR07781A","volume":"9","author":"X Chen","year":"2017","unstructured":"Chen, X., M. Han, H. Chen, X. Cheng, Y. Song, Z. Su, Y. Jiang, and H. Zhang. A wave-shaped hybrid piezoelectric and triboelectric nanogenerator based on P(VDF-TrFE) nanofibers. Nanoscale. 9(3):1263\u20131270, 2017. https:\/\/doi.org\/10.1039\/C6NR07781A.","journal-title":"Nanoscale"},{"key":"4297_CR139","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.eml.2016.05.015","volume":"9","author":"C Dagdeviren","year":"2016","unstructured":"Dagdeviren, C., P. Joe, O. L. Tuzman, K.-I. Park, K. J. Lee, Y. Shi, Y. Huang, and J. A. Rogers. Recent progress in flexible and stretchable piezoelectric devices for mechanical energy harvesting, sensing and actuation. Extreme Mech. Lett. 9:269\u2013281, 2016. https:\/\/doi.org\/10.1016\/j.eml.2016.05.015.","journal-title":"Extreme Mech. Lett."},{"issue":"7","key":"4297_CR140","doi-asserted-by":"publisher","first-page":"1700029","DOI":"10.1002\/advs.201700029","volume":"4","author":"Q Zheng","year":"2017","unstructured":"Zheng, Q., B. Shi, Z. Li, and Z. L. Wang. Recent progress on piezoelectric and triboelectric energy harvesters in biomedical systems. Adv. Sci. 4(7):1700029, 2017. https:\/\/doi.org\/10.1002\/advs.201700029.","journal-title":"Adv. Sci."},{"issue":"8","key":"4297_CR141","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.3390\/nano12081366","volume":"12","author":"C Wang","year":"2022","unstructured":"Wang, C., Q. Shi, and C. Lee. Advanced implantable biomedical devices enabled by triboelectric nanogenerators. Nanomaterials. 12(8):1366, 2022. https:\/\/doi.org\/10.3390\/nano12081366.","journal-title":"Nanomaterials"},{"issue":"1","key":"4297_CR142","doi-asserted-by":"publisher","first-page":"4374","DOI":"10.1038\/s41467-021-24417-w","volume":"12","author":"H Ryu","year":"2021","unstructured":"Ryu, H., H.-M. Park, M.-K. Kim, B. Kim, H. S. Myoung, T. Y. Kim, H.-J. Yoon, S. S. Kwak, J. Kim, T. H. Hwang, E.-K. Choi, and S.-W. Kim. Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators. Nat. Commun. 12(1):4374, 2021. https:\/\/doi.org\/10.1038\/s41467-021-24417-w.","journal-title":"Nat. Commun."},{"key":"4297_CR143","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202400797","author":"M Mariello","year":"2024","unstructured":"Mariello, M., and C. M. Proctor. Wireless power and data transfer technologies for flexible bionic and bioelectronic interfaces: materials and applications. Adv. Mater. Technol. 2024. https:\/\/doi.org\/10.1002\/admt.202400797.","journal-title":"Adv. Mater. Technol."},{"issue":"12","key":"4297_CR144","doi-asserted-by":"publisher","first-page":"3487","DOI":"10.3390\/s20123487","volume":"20","author":"SR Khan","year":"2020","unstructured":"Khan, S. R., S. K. Pavuluri, G. Cummins, and M. P. Y. Desmulliez. Wireless power transfer techniques for implantable medical devices: a review. Sensors. 20(12):3487, 2020. https:\/\/doi.org\/10.3390\/s20123487.","journal-title":"Sensors"},{"key":"4297_CR145","doi-asserted-by":"publisher","first-page":"113007","DOI":"10.1016\/j.bios.2021.113007","volume":"178","author":"T Stuart","year":"2021","unstructured":"Stuart, T., L. Cai, A. Burton, and P. Gutruf. Wireless and battery-free platforms for collection of biosignals. Biosens. Bioelectron. 178:113007, 2021. https:\/\/doi.org\/10.1016\/j.bios.2021.113007.","journal-title":"Biosens. Bioelectron."},{"key":"4297_CR146","doi-asserted-by":"publisher","unstructured":"Ansari, S., A. Das, and A. Bhattacharya. Resonant inductive wireless power transfer of two-coil system with class-e resonant high frequency inverter. In: 2019 6th International Conference on Signal Processing and Integrated Networks (SPIN), 2019. Noida: IEEE, 2019, pp. 269\u2013273. https:\/\/doi.org\/10.1109\/SPIN.2019.8711782.","DOI":"10.1109\/SPIN.2019.8711782"},{"issue":"22","key":"4297_CR147","doi-asserted-by":"publisher","first-page":"223902","DOI":"10.1063\/1.4971185","volume":"109","author":"M Song","year":"2016","unstructured":"Song, M., P. Belov, and P. Kapitanova. Wireless power transfer based on dielectric resonators with colossal permittivity. Appl. Phys. Lett. 109(22):223902, 2016. https:\/\/doi.org\/10.1063\/1.4971185.","journal-title":"Appl. Phys. Lett."},{"issue":"1","key":"4297_CR148","doi-asserted-by":"publisher","first-page":"20220106","DOI":"10.1002\/EXP.20220106","volume":"4","author":"M Xu","year":"2024","unstructured":"Xu, M., Y. Liu, K. Yang, S. Li, M. Wang, J. Wang, D. Yang, M. Shkunov, S. R. P. Silva, F. A. Castro, and Y. Zhao. Minimally invasive power sources for implantable electronics. Exploration. 4(1):20220106, 2024. https:\/\/doi.org\/10.1002\/EXP.20220106.","journal-title":"Exploration"},{"issue":"15","key":"4297_CR149","doi-asserted-by":"publisher","first-page":"3321","DOI":"10.3390\/ma13153321","volume":"13","author":"C Fares","year":"2020","unstructured":"Fares, C., S.-M. Hsu, M. Xian, X. Xia, F. Ren, J. J. Mecholsky, L. Gonzaga, and J. Esquivel-Upshaw. Demonstration of a SiC protective coating for titanium implants. Materials. 13(15):3321, 2020. https:\/\/doi.org\/10.3390\/ma13153321.","journal-title":"Materials"},{"key":"4297_CR150","doi-asserted-by":"publisher","unstructured":"Perez-Nicoli, P., M. Biancheri-Astier, A. Diet, Y. L. Bihan, L. Pichon, and F. Silveira. Influence of the titanium case used in implantable medical devices on the wireless power link. In: 2018 IEEE Wireless Power Transfer Conference (WPTC), 2018. Montreal: IEEE, 2018, pp. 1\u20133. https:\/\/doi.org\/10.1109\/WPT.2018.8639416.","DOI":"10.1109\/WPT.2018.8639416"},{"issue":"43","key":"4297_CR151","doi-asserted-by":"publisher","first-page":"2003713","DOI":"10.1002\/aenm.202003713","volume":"11","author":"L Liu","year":"2021","unstructured":"Liu, L., N. Solin, and O. Ingan\u00e4s. Bio based batteries. Adv. Energy Mater. 11(43):2003713, 2021. https:\/\/doi.org\/10.1002\/aenm.202003713.","journal-title":"Adv. Energy Mater."},{"issue":"14","key":"4297_CR152","doi-asserted-by":"publisher","first-page":"2340","DOI":"10.1002\/adma.201500121","volume":"27","author":"Y Zi","year":"2015","unstructured":"Zi, Y., L. Lin, J. Wang, S. Wang, J. Chen, X. Fan, P.-K. Yang, F. Yi, and Z. L. Wang. Triboelectric\u2013pyroelectric\u2013piezoelectric hybrid cell for high-efficiency energy-harvesting and self-powered sensing. Adv. Mater. 27(14):2340\u20132347, 2015. https:\/\/doi.org\/10.1002\/adma.201500121.","journal-title":"Adv. Mater."},{"issue":"3","key":"4297_CR153","doi-asserted-by":"publisher","first-page":"182","DOI":"10.5940\/jcrsj.44.182","volume":"44","author":"K Kajihara","year":"2002","unstructured":"Kajihara, K., M. Hirano, and H. Hosono. Vacuum-ultraviolet transparency of silica glass and its interaction with vacuum-ultraviolet lasers. Nihon Kessho Gakkaishi. 44(3):182\u2013188, 2002. https:\/\/doi.org\/10.5940\/jcrsj.44.182.","journal-title":"Nihon Kessho Gakkaishi"},{"issue":"10","key":"4297_CR154","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.3390\/ma18102183","volume":"18","author":"Y Liu","year":"2025","unstructured":"Liu, Y., C. Huang, J. Guo, H. Zu, J. Shen, P. Zhang, and W. Chen. Superspreading-based fabrication of poly(methyl methacrylate) films with high toughness for ultra-wideband flexible transparent antenna. Materials. 18(10):2183, 2025. https:\/\/doi.org\/10.3390\/ma18102183.","journal-title":"Materials"},{"key":"4297_CR155","doi-asserted-by":"publisher","unstructured":"Schulz, U., N. Gratzke, T. Seifert, C. Hahmann, F. Rickelt, and S. Schr\u00f6der. Properties of new transparent polymers for optical applications. In: Advances in Optical Thin Films VII, edited by M. Lequime, and D. P. Ristau, 2021, Vol. 16. SPIE, Online Only, 2021. https:\/\/doi.org\/10.1117\/12.2597061.","DOI":"10.1117\/12.2597061"},{"key":"4297_CR156","unstructured":"Chen, K.-C., A. M. Wo, and Y.-F. Chen. Transmission spectrum of PDMS in 4\u20137 $$\\mu$$m mid-IR range for characterization of protein structure. In: NSTI-Nanotech, 2006, Vol. 2, pp. 732\u2013735. ISBN 0-9767985-7-3."},{"key":"4297_CR157","doi-asserted-by":"publisher","first-page":"107063","DOI":"10.1016\/j.jqsrt.2020.107063","volume":"252","author":"X Zhang","year":"2020","unstructured":"Zhang, X., J. Qiu, J. Zhao, X. Li, and L. Liu. Complex refractive indices measurements of polymers in infrared bands. J. Quant. Spectrosc. Radiat. Transf. 252:107063, 2020. https:\/\/doi.org\/10.1016\/j.jqsrt.2020.107063.","journal-title":"J. Quant. Spectrosc. Radiat. Transf."},{"key":"4297_CR158","doi-asserted-by":"publisher","unstructured":"Druffel, T., O. Buazza, M. Lattis, and S. Farmer. Nanocomposite thin films exhibiting high mechanical and optical flexibility. In: Optical Engineering + Applications, San Diego, California, USA, 2008, edited by J. D. T. Kruschwitz, and M. J. Ellison, p. 70670. https:\/\/doi.org\/10.1117\/12.795294.","DOI":"10.1117\/12.795294"},{"issue":"11","key":"4297_CR159","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1177\/0892705718797157","volume":"32","author":"W Wildner","year":"2019","unstructured":"Wildner, W., and D. Drummer. Nanofiller materials for transparent polymer composites: influences on the properties and on the transparency\u2014a review. J. Thermoplast. Compos. Mater. 32(11):1547\u20131565, 2019. https:\/\/doi.org\/10.1177\/0892705718797157.","journal-title":"J. Thermoplast. Compos. Mater."},{"issue":"5881","key":"4297_CR160","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1126\/science.1156965","volume":"320","author":"RR Nair","year":"2008","unstructured":"Nair, R. R., P. Blake, A. N. Grigorenko, K. S. Novoselov, T. J. Booth, T. Stauber, N. M. R. Peres, and A. K. Geim. Fine structure constant defines visual transparency of graphene. Science. 320(5881):1308, 2008. https:\/\/doi.org\/10.1126\/science.1156965.","journal-title":"Science"},{"issue":"7","key":"4297_CR161","doi-asserted-by":"publisher","first-page":"2374","DOI":"10.1021\/cm500641a","volume":"26","author":"J Halim","year":"2014","unstructured":"Halim, J., M. R. Lukatskaya, K. M. Cook, J. Lu, C. R. Smith, L.-T. N\u00e4slund, S. J. May, L. Hultman, Y. Gogotsi, and M. W. Barsoum. Transparent conductive two-dimensional titanium carbide (MXene) films. Chem. Mater. 26(7):2374\u20132381, 2014. https:\/\/doi.org\/10.1021\/cm500641a.","journal-title":"Chem. Mater."},{"issue":"6","key":"4297_CR162","doi-asserted-by":"publisher","first-page":"1600050","DOI":"10.1002\/aelm.201600050","volume":"2","author":"K Hantanasirisakul","year":"2016","unstructured":"Hantanasirisakul, K., M.-Q. Zhao, P. Urbankowski, J. Halim, B. Anasori, S. Kota, C. E. Ren, M. W. Barsoum, and Y. Gogotsi. Fabrication of Ti$$_{3}$$C$$_{2}$$T$$_x$$ MXene transparent thin films with tunable optoelectronic properties. Adv. Electron. Mater. 2(6):1600050, 2016. https:\/\/doi.org\/10.1002\/aelm.201600050.","journal-title":"Adv. Electron. Mater."},{"issue":"5","key":"4297_CR163","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1109\/TBCAS.2013.2237905","volume":"7","author":"B Eilebrecht","year":"2013","unstructured":"Eilebrecht, B., J. Willkomm, A. Pohl, T. Wartzek, and S. Leonhardt. Impedance measurement system for determination of capacitive electrode coupling. IEEE Trans. Biomed. Circuits Syst. 7(5):682\u2013689, 2013. https:\/\/doi.org\/10.1109\/TBCAS.2013.2237905.","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"issue":"2","key":"4297_CR164","doi-asserted-by":"publisher","first-page":"100022","DOI":"10.1016\/j.device.2023.100022","volume":"1","author":"M Gao","year":"2023","unstructured":"Gao, M., Y. Yao, F. Yang, J. Ye, G. Liu, B. Wang, S. Liu, P. Wang, and Y. Lu. Two-dimensional materials for wireless power transfer. Device. 1(2):100022, 2023. https:\/\/doi.org\/10.1016\/j.device.2023.100022.","journal-title":"Device"},{"issue":"2","key":"4297_CR165","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1109\/TCPMT.2012.2185792","volume":"3","author":"F Bossuyt","year":"2013","unstructured":"Bossuyt, F., T. Vervust, and J. Vanfleteren. Stretchable electronics technology for large area applications: fabrication and mechanical characterization. IEEE Trans. Compon. Packag. Manuf. Technol. 3(2):229\u2013235, 2013. https:\/\/doi.org\/10.1109\/TCPMT.2012.2185792.","journal-title":"IEEE Trans. Compon. Packag. Manuf. Technol."},{"issue":"8","key":"4297_CR166","doi-asserted-by":"publisher","first-page":"3043","DOI":"10.1364\/OME.463349","volume":"12","author":"LA Moore","year":"2022","unstructured":"Moore, L. A., and C. M. Smith. Fused silica as an optical material. Opt. Mater. Express. 12(8):3043\u20133059, 2022. https:\/\/doi.org\/10.1364\/OME.463349.","journal-title":"Opt. Mater. Express"},{"issue":"2","key":"4297_CR167","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1134\/S0012500819080019","volume":"487","author":"GP Panasyuk","year":"2019","unstructured":"Panasyuk, G. P., I. V. Kozerozhets, M. N. Danchevskaya, Y. D. Ivakin, G. P. Murav\u2019eva, and A. D. Izotov. A new method for synthesis of fine crystalline magnesium aluminate spinel. Dokl. Chem. 487(2):218\u2013220, 2019. https:\/\/doi.org\/10.1134\/S0012500819080019.","journal-title":"Dokl. Chem."},{"issue":"10","key":"4297_CR168","doi-asserted-by":"publisher","first-page":"6047","DOI":"10.1016\/j.jeurceramsoc.2024.03.049","volume":"44","author":"P Zubrzycka","year":"2024","unstructured":"Zubrzycka, P., M. Radecka, T. Graule, A. Trenczek-Zajac, D. Zientara, and M. Stuer. MgAl$$_{2}$$O$$_{4}$$ spinel with transmittance approaching theoretical value at reduced sintering temperatures. J. Eur. Ceram. Soc. 44(10):6047\u20136059, 2024. https:\/\/doi.org\/10.1016\/j.jeurceramsoc.2024.03.049.","journal-title":"J. Eur. Ceram. Soc."},{"issue":"8","key":"4297_CR169","doi-asserted-by":"publisher","first-page":"5366","DOI":"10.1103\/PhysRevB.51.5366","volume":"51","author":"AK Sarychev","year":"1995","unstructured":"Sarychev, A. K., D. J. Bergman, and Y. Yagil. Theory of the optical and microwave properties of metal-dielectric films. Phys. Rev. B. 51(8):5366\u20135385, 1995. https:\/\/doi.org\/10.1103\/PhysRevB.51.5366.","journal-title":"Phys. Rev. B"},{"issue":"10","key":"4297_CR170","doi-asserted-by":"publisher","first-page":"49962","DOI":"10.1002\/app.49962","volume":"138","author":"K Zeranska-Chudek","year":"2021","unstructured":"Zeranska-Chudek, K., A. Lapinska, A. Siemion, A. M. Jastrz\u0119bska, and M. Zdrojek. Terahertz time domain spectroscopy of graphene and MXene polymer composites. J. Appl. Polym. Sci. 138(10):49962, 2021. https:\/\/doi.org\/10.1002\/app.49962.","journal-title":"J. Appl. Polym. Sci."},{"key":"4297_CR171","doi-asserted-by":"publisher","first-page":"123","DOI":"10.4028\/www.scientific.net\/AMR.900.123","volume":"900","author":"XG Miao","year":"2014","unstructured":"Miao, X. G., Y. R. Qu, F. Ghezzo, X. W. Fang, Y. T. Yue, Z. Y. Zhao, and R. P. Liu. Fused silica ceramics and composites for radome applications. Adv. Mater. Res. 900:123\u2013129, 2014. https:\/\/doi.org\/10.4028\/www.scientific.net\/AMR.900.123.","journal-title":"Adv. Mater. Res."},{"issue":"33","key":"4297_CR172","doi-asserted-by":"publisher","first-page":"8118","DOI":"10.1364\/AO.46.008118","volume":"46","author":"R Kitamura","year":"2007","unstructured":"Kitamura, R., L. Pilon, and M. Jonasz. Optical constants of silica glass from extreme ultraviolet to far infrared at near room temperature. Appl. Opt. 46(33):8118\u20138133, 2007. https:\/\/doi.org\/10.1364\/AO.46.008118.","journal-title":"Appl. Opt."},{"key":"4297_CR173","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1016\/j.snb.2014.05.063","volume":"202","author":"Y Qin","year":"2014","unstructured":"Qin, Y., M. M. R. Howlader, M. J. Deen, Y. M. Haddara, and P. R. Selvaganapathy. Polymer integration for packaging of implantable sensors. Sens. Actuators B. 202:758\u2013778, 2014. https:\/\/doi.org\/10.1016\/j.snb.2014.05.063.","journal-title":"Sens. Actuators B"},{"issue":"9","key":"4297_CR174","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.3390\/mi12091020","volume":"12","author":"S Seok","year":"2021","unstructured":"Seok, S. Polymer-based biocompatible packaging for implantable devices: packaging method, materials, and reliability simulation. Micromachines. 12(9):1020, 2021. https:\/\/doi.org\/10.3390\/mi12091020.","journal-title":"Micromachines"},{"issue":"3","key":"4297_CR175","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1109\/MAP.2012.6293982","volume":"54","author":"A Kiourti","year":"2012","unstructured":"Kiourti, A., and K. S. Nikita. A review of implantable patch antennas for biomedical telemetry: challenges and solutions. IEEE Antennas Propag. Mag. 54(3):210\u2013228, 2012. https:\/\/doi.org\/10.1109\/MAP.2012.6293982.","journal-title":"IEEE Antennas Propag. Mag."},{"issue":"10","key":"4297_CR176","doi-asserted-by":"publisher","first-page":"183","DOI":"10.3390\/mi7100183","volume":"7","author":"M Birkholz","year":"2016","unstructured":"Birkholz, M., T. Basmer, D. Genschow, R. Ehwald, R. K\u00f6titz, S. Knaack, M. Nagel, M. Zamora, and S. Risse. Continuously operating biosensor and its integration into a hermetically sealed medical implant. Micromachines. 7(10):183, 2016. https:\/\/doi.org\/10.3390\/mi7100183.","journal-title":"Micromachines"},{"issue":"6","key":"4297_CR177","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1007\/s40145-022-0584-4","volume":"11","author":"C Yang","year":"2022","unstructured":"Yang, C., J. Huang, Q. Huang, Z. Deng, Y. Wang, X. Li, Z. Zhou, J. Chen, Z. Liu, and W. Guo. Optical, thermal, and mechanical properties of (Y$$_{1-x}$$Sc$$_x$$)$$_{2}$$O$$_{3}$$ transparent ceramics. J. Adv. Ceram. 11(6):901\u2013911, 2022. https:\/\/doi.org\/10.1007\/s40145-022-0584-4.","journal-title":"J. Adv. Ceram."},{"issue":"5","key":"4297_CR178","doi-asserted-by":"publisher","first-page":"054024","DOI":"10.1103\/PhysRevApplied.7.054024","volume":"7","author":"DD Stupin","year":"2017","unstructured":"Stupin, D. D., S. V. Koniakhin, N. A. Verlov, and M. V. Dubina. Adaptive filtering to enhance noise immunity of impedance and admittance spectroscopy: comparison with Fourier transformation. Phys. Rev. Appl. 7(5):054024, 2017. https:\/\/doi.org\/10.1103\/PhysRevApplied.7.054024.","journal-title":"Phys. Rev. Appl."},{"issue":"4","key":"4297_CR179","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1109\/TBME.1983.325225","volume":"30","author":"GS Furno","year":"1983","unstructured":"Furno, G. S., and W. J. Tompkins. A learning filter for removing noise interference. IEEE Trans. Biomed. Eng. 30(4):234\u2013235, 1983. https:\/\/doi.org\/10.1109\/TBME.1983.325225.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"4297_CR180","doi-asserted-by":"publisher","unstructured":"Mollaei, Y.: Hardware implementation of adaptive filters. In: 2009 IEEE Student Conference on Research and Development (SCOReD), 2009. IEEE, UPM Serdang, 2009, pp. 45\u201348. https:\/\/doi.org\/10.1109\/SCORED.2009.5443365.","DOI":"10.1109\/SCORED.2009.5443365"},{"key":"4297_CR181","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1186\/1475-925X-13-149","volume":"13","author":"A C\u00f6mert","year":"2014","unstructured":"C\u00f6mert, A., M. Honkala, and J. Hyttinen. Impedance spectroscopy of changes in skin-electrode impedance induced by motion. Biomed. Eng. Online. 13:149, 2014. https:\/\/doi.org\/10.1186\/1475-925X-13-149.","journal-title":"Biomed. Eng. Online"},{"key":"4297_CR182","doi-asserted-by":"publisher","unstructured":"Ashley, B. K., and U. Hassan. Frequency\u2013time domain (FTD) impedance data analysis to improve accuracy of microparticle enumeration in a microfluidic electronic counter. In: 2021 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2021. IEEE, 2021, pp. 1201\u20131204. https:\/\/doi.org\/10.1109\/EMBC46164.2021.9630635.","DOI":"10.1109\/EMBC46164.2021.9630635"},{"key":"4297_CR183","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2024.3468374","author":"Z Yu","year":"2024","unstructured":"Yu, Z., Y. Zou, H.-C. Liao, F. Alrashdan, Z. Wen, J. E. Woods, W. Wang, J. T. Robinson, and K. Yang. A miniature batteryless bioelectronic implant using one magnetoelectric transducer for wireless powering and PWM backscatter communication. IEEE Trans. Biomed. Circuits Syst. 2024. https:\/\/doi.org\/10.1109\/TBCAS.2024.3468374.","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"4297_CR184","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4304\/jcm.3.2.13-21","volume":"3","author":"L Biard","year":"2008","unstructured":"Biard, L., and D. Noguet. Reed\u2013Solomon codes for low power communications. J. Commun. 3:13\u201321, 2008. https:\/\/doi.org\/10.4304\/jcm.3.2.13-21.","journal-title":"J. Commun."},{"issue":"8","key":"4297_CR185","doi-asserted-by":"publisher","first-page":"703","DOI":"10.4236\/ijcns.2010.38094","volume":"3","author":"D Bera","year":"2010","unstructured":"Bera, D., T. Chakravarty, and S. Chakrabarti. Reliable wireless communication for medical devices using turbo convolution code. Int. J. Commun. Netw. Syst. Sci. 3(8):703\u2013710, 2010. https:\/\/doi.org\/10.4236\/ijcns.2010.38094.","journal-title":"Int. J. Commun. Netw. Syst. Sci."},{"key":"4297_CR186","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: Reveal LINQ. U.S. FDA, 2014. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K132649."},{"key":"4297_CR187","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: Reveal XT. U.S. FDA, 2007. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K071641."},{"key":"4297_CR188","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: Assert IQ ICM. U.S. FDA, 2023. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K230286."},{"key":"4297_CR189","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: Jot Dx ICM. U.S. FDA, 2021. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K212206."},{"key":"4297_CR190","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: BioMonitor III. U.S. FDA, 2019. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K190548."},{"key":"4297_CR191","unstructured":"U.S. Food and Drug Administration. PMA Supplement Approval: Eversense E3 Continuous Glucose Monitoring System, P160048\/S016. U.S. FDA, 2022. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpma\/pma.cfm?id=P160048S016."},{"key":"4297_CR192","unstructured":"U.S. Food and Drug Administration. 510(k) Premarket Notification: Eversense 365. U.S. FDA, 2024. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K241335."},{"key":"4297_CR193","unstructured":"U.S. Food and Drug Administration. De Novo Classification Request: Minder System. U.S. FDA, 2025. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/denovo.cfm?id=DEN240062."},{"key":"4297_CR194","unstructured":"Grand View Research. Implantable Loop Recorders Market Size, Share Report, 2030. Grand View Research, 2024. https:\/\/www.grandviewresearch.com\/industry-analysis\/implantable-loop-recorders-market Accessed 1 Aug 2025."},{"key":"4297_CR195","unstructured":"Grand View Research. Continuous Glucose Monitoring Devices Market Report, 2033. Grand View Research, 2025. https:\/\/www.grandviewresearch.com\/industry-analysis\/continuous-glucose-monitoring-market."},{"key":"4297_CR196","unstructured":"Towards Healthcare: Continuous Glucose Monitoring Devices Market Size to Reach USD 10.7 Billion by 2035, 2025. https:\/\/www.towardshealthcare.com\/insights\/continuous-glucose-monitoring-devices-market-sizing."},{"key":"4297_CR197","unstructured":"Grand View Research. Epilepsy Monitoring Devices Market Size, Share Report, 2030. Grand View Research, 2025. https:\/\/www.grandviewresearch.com\/industry-analysis\/epilepsy-monitoring-devices-market-report."},{"key":"4297_CR198","doi-asserted-by":"publisher","first-page":"139043","DOI":"10.1109\/ACCESS.2021.3118554","volume":"9","author":"RR Warty","year":"2021","unstructured":"Warty, R. R., V. Smith, M. Salih, D. Fox, S. L. McArthur, and B. W. Mol. Barriers to the diffusion of medical technologies within healthcare: a systematic review. IEEE Access. 9:139043\u2013139058, 2021. https:\/\/doi.org\/10.1109\/ACCESS.2021.3118554.","journal-title":"IEEE Access"},{"issue":"1","key":"4297_CR199","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1186\/s12913-019-4305-9","volume":"19","author":"V Smith","year":"2019","unstructured":"Smith, V., R. Warty, A. Nair, S. Krishnan, J. A. Sursas, F. Silva Costa, B. Vollenhoven, and E. M. Wallace. Defining the clinician\u2019s role in early health technology assessment during medical device innovation: a systematic review. BMC Health Serv. Res. 19(1):514, 2019. https:\/\/doi.org\/10.1186\/s12913-019-4305-9.","journal-title":"BMC Health Serv. Res."},{"issue":"2","key":"4297_CR200","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.hrthm.2016.11.001","volume":"14","author":"JD Rogers","year":"2017","unstructured":"Rogers, J. D., P. Sanders, C. Piorkowski, M. R. Sohail, R. Anand, K. J. Crossen, F. S. Khairallah, R. E. Kaplon, K. Stromberg, and R. C. Kowal. In-office insertion of a miniaturized insertable cardiac monitor: results from the Reveal LINQ in-Office 2 randomized study. Heart Rhythm. 14(2):218\u2013224, 2017. https:\/\/doi.org\/10.1016\/j.hrthm.2016.11.001.","journal-title":"Heart Rhythm"},{"issue":"10","key":"4297_CR201","doi-asserted-by":"publisher","first-page":"1624","DOI":"10.1093\/europace\/euw304","volume":"19","author":"J Steffel","year":"2017","unstructured":"Steffel, J., D. J. Wright, H. Sch\u00e4fer, T. Rashid-Fadel, and T. Lewalter. Insertion of miniaturized cardiac monitors outside the catheter operating room: experience and practical advice. Europace. 19(10):1624\u20131629, 2017. https:\/\/doi.org\/10.1093\/europace\/euw304.","journal-title":"Europace"},{"issue":"5","key":"4297_CR202","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1089\/dia.2018.0397","volume":"21","author":"D Deiss","year":"2019","unstructured":"Deiss, D., A. Szadkowska, D. Gordon, A. Mallipedhi, I. Schutz-Fuhrmann, E. Aguilera, C. Ringsell, and C. De Block. Clinical practice recommendations on the routine use of Eversense, the first long-term implantable continuous glucose monitoring system. Diabetes Technol. Ther. 21(5):254\u2013264, 2019. https:\/\/doi.org\/10.1089\/dia.2018.0397.","journal-title":"Diabetes Technol. Ther."},{"key":"4297_CR203","doi-asserted-by":"publisher","first-page":"1304343","DOI":"10.3389\/fsurg.2023.1304343","volume":"10","author":"BD Djurhuus","year":"2023","unstructured":"Djurhuus, B. D., P. F. Viana, E. Ahrens, S. S. Nielsen, H. L. Srinivasan, M. P. Richardson, P. Hom\u00f8e, H. Hasegawa, A. A. Zarei, P. L. K. Gauger, J. Duun-Henriksen, et al. Minimally invasive surgery for placement of a subcutaneous EEG implant. Front. Surg. 10:1304343, 2023. https:\/\/doi.org\/10.3389\/fsurg.2023.1304343.","journal-title":"Front. Surg."},{"key":"4297_CR204","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.ijcard.2017.03.144","volume":"241","author":"SZ Diederichsen","year":"2017","unstructured":"Diederichsen, S. Z., K. J. Haugan, S. H\u00f8jberg, A. G. Holst, L. K\u00f8ber, K. B. Pedersen, C. Graff, D. Krieger, A. Brandes, and J. H. Svendsen. Complications after implantation of a new-generation insertable cardiac monitor: results from the LOOP study. Int. J. Cardiol. 241:229\u2013234, 2017. https:\/\/doi.org\/10.1016\/j.ijcard.2017.03.144.","journal-title":"Int. J. Cardiol."},{"issue":"5","key":"4297_CR205","doi-asserted-by":"publisher","first-page":"068","DOI":"10.1093\/europace\/euad068","volume":"25","author":"F Quartieri","year":"2023","unstructured":"Quartieri, F., M. Harish, L. Cal\u00f2, I. Ebrahim, A. Fusco, S. Mester, F. Cauti, S.-J. Park, P. Francia, M. Giovagnoni, P. Adragao, B. Vezi, W. Lin, C. S. Hutson, and A. Grammatico. New insertable cardiac monitors show high diagnostic yield and good safety profile in real-world clinical practice: results from the international prospective observational SMART Registry. Europace. 25(5):068, 2023. https:\/\/doi.org\/10.1093\/europace\/euad068.","journal-title":"Europace"},{"issue":"1","key":"4297_CR206","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1089\/dia.2019.0159","volume":"22","author":"D Deiss","year":"2020","unstructured":"Deiss, D., C. Irace, G. Carlson, K. S. Tweden, and F. R. Kaufman. Real-world safety of an implantable continuous glucose sensor over multiple cycles of use: a post-market registry study. Diabetes Technol. Ther. 22(1):48\u201352, 2020. https:\/\/doi.org\/10.1089\/dia.2019.0159.","journal-title":"Diabetes Technol. Ther."},{"key":"4297_CR207","unstructured":"National Institute for Health and Care Excellence. 24\/7 EEG SubQ for Epilepsy. Medtech Innovation Briefing MIB277. National Institute for Health and Care Excellence, 2021. https:\/\/www.nice.org.uk\/advice\/mib277."},{"issue":"5","key":"4297_CR208","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1093\/europace\/euv053","volume":"17","author":"KA Polyzos","year":"2015","unstructured":"Polyzos, K. A., A. A. Konstantelias, and M. E. Falagas. Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis. Europace. 17(5):767\u2013777, 2015. https:\/\/doi.org\/10.1093\/europace\/euv053.","journal-title":"Europace"},{"issue":"21","key":"4297_CR209","doi-asserted-by":"publisher","first-page":"2160","DOI":"10.1001\/jama.2021.6128","volume":"325","author":"BH Buck","year":"2021","unstructured":"Buck, B. H., M. D. Hill, F. R. Quinn, K. S. Butcher, B. K. Menon, S. Gulamhusein, M. Siddiqui, S. B. Coutts, T. Jeerakathil, E. E. Smith, K. Khan, P. A. Barber, G. Jickling, L. Reyes, S. Save, P. Fairall, L. Piquette, N. Kamal, D. S. Chew, A. M. Demchuk, A. Shuaib, and D. V. Exner. Effect of implantable vs prolonged external electrocardiographic monitoring on atrial fibrillation detection in patients with ischemic stroke: the PER DIEM randomized clinical trial. JAMA. 325(21):2160\u20132168, 2021. https:\/\/doi.org\/10.1001\/jama.2021.6128.","journal-title":"JAMA"},{"key":"4297_CR210","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/s12872-023-03073-6","volume":"23","author":"MSV Elkind","year":"2023","unstructured":"Elkind, M. S. V., K. K. Witte, S. E. Kasner, L. M. Sawyer, F. W. Grimsey Jones, C. Rinciog, S. Tsintzos, S. C. Rosemas, D. Lanctin, P. D. Ziegler, and M. R. Reynolds. Cost-effectiveness of an insertable cardiac monitor in a high-risk population in the US. BMC Cardiovasc. Disord. 23:45, 2023. https:\/\/doi.org\/10.1186\/s12872-023-03073-6.","journal-title":"BMC Cardiovasc. Disord."},{"issue":"1","key":"4297_CR211","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1007\/s40618-021-01624-2","volume":"45","author":"F Boscari","year":"2022","unstructured":"Boscari, F., M. Vettoretti, F. Cavallin, A. M. L. Amato, A. Uliana, V. Vallone, A. Avogaro, A. Facchinetti, and D. Bruttomesso. Implantable and transcutaneous continuous glucose monitoring system: a randomized cross over trial comparing accuracy, efficacy and acceptance. J. Endocrinol. Investig. 45(1):115\u2013124, 2022. https:\/\/doi.org\/10.1007\/s40618-021-01624-2.","journal-title":"J. Endocrinol. Investig."},{"key":"4297_CR212","doi-asserted-by":"publisher","first-page":"713794","DOI":"10.3389\/fneur.2021.713794","volume":"12","author":"RE Stirling","year":"2021","unstructured":"Stirling, R. E., M. I. Maturana, P. J. Karoly, E. S. Nurse, K. McCutcheon, D. B. Grayden, S. G. Ringo, J. M. Heasman, R. J. Hoare, A. Lai, W. D\u2019Souza, U. Seneviratne, L. Seiderer, K. J. McLean, K. J. Bulluss, M. Murphy, B. H. Brinkmann, M. P. Richardson, D. R. Freestone, and M. J. Cook. Seizure forecasting using a novel sub-scalp ultra-long term EEG monitoring system. Front. Neurol. 12:713794, 2021. https:\/\/doi.org\/10.3389\/fneur.2021.713794.","journal-title":"Front. Neurol."},{"issue":"1","key":"4297_CR213","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1111\/epi.18644","volume":"67","author":"T Munteanu","year":"2026","unstructured":"Munteanu, T., B. Daly, C. O\u2019Donnell, A. Breen, T. Choekyi, B. Staunton-Grufferty, D. O\u2019Brien, K. Sweeney, R. Kilbride, P. Widdess-Walsh, H. El-Naggar, and N. Delanty. Unilateral ultra long-term subcutaneous EEG monitoring in drug-refractory idiopathic generalized epilepsy. Epilepsia. 67(1):396\u2013407, 2026. https:\/\/doi.org\/10.1111\/epi.18644.","journal-title":"Epilepsia"},{"key":"4297_CR214","doi-asserted-by":"publisher","first-page":"3366","DOI":"10.57187\/s.3366","volume":"154","author":"DG Rohner","year":"2024","unstructured":"Rohner, D. G., L. Burget, C. Henzen, and S. Fischli. Impact on diabetes control and patient-reported outcomes of a newer implantable continuous glucose monitoring system (Eversense CGM system): a single-centre retro- and prospective observational study. Swiss Med. Wkly. 154:3366, 2024. https:\/\/doi.org\/10.57187\/s.3366.","journal-title":"Swiss Med. Wkly"},{"issue":"3","key":"4297_CR215","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1177\/1932296816688010","volume":"11","author":"ML Tanenbaum","year":"2017","unstructured":"Tanenbaum, M. L., R. N. Adams, S. J. Hanes, R. C. Barley, K. M. Miller, S. A. Mulvaney, and K. K. Hood. Optimal use of diabetes devices: clinician perspectives on barriers and adherence to device use. J. Diabetes Sci. Technol. 11(3):484\u2013492, 2017. https:\/\/doi.org\/10.1177\/1932296816688010.","journal-title":"J. Diabetes Sci. Technol."},{"issue":"2","key":"4297_CR216","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/WNP.0000000000001169","volume":"43","author":"N Zabler","year":"2026","unstructured":"Zabler, N., Y. Novitskaya, R. Spr\u00fcnken, M. Hirsch, M. D\u00fcmpelmann, and A. Schulze-Bonhage. Long-term adherence to a subcutaneous two-channel EEG system in patients with focal epilepsy. J. Clin. Neurophysiol. 43(2):150\u2013156, 2026. https:\/\/doi.org\/10.1097\/WNP.0000000000001169.","journal-title":"J. Clin. Neurophysiol."},{"key":"4297_CR217","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.seizure.2023.05.007","volume":"110","author":"M Milne-Ives","year":"2023","unstructured":"Milne-Ives, M., J. Duun-Henriksen, L. Blaabjerg, B. McLean, R. Shankar, and E. Meinert. At home EEG monitoring technologies for people with epilepsy and intellectual disabilities: a scoping review. Seizure. 110:11\u201320, 2023. https:\/\/doi.org\/10.1016\/j.seizure.2023.05.007.","journal-title":"Seizure"},{"issue":"4","key":"4297_CR218","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1046\/j.1540-8167.2005.40134.x","volume":"16","author":"JL Burns","year":"2005","unstructured":"Burns, J. L., E. R. Serber, S. Keim, and S. F. Sears. Measuring patient acceptance of implantable cardiac device therapy: initial psychometric investigation of the Florida patient acceptance survey. J. Cardiovasc. Electrophysiol. 16(4):384\u2013390, 2005. https:\/\/doi.org\/10.1046\/j.1540-8167.2005.40134.x.","journal-title":"J. Cardiovasc. Electrophysiol."},{"issue":"9","key":"4297_CR219","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1111\/pace.13421","volume":"41","author":"VS Frydensberg","year":"2018","unstructured":"Frydensberg, V. S., S. J. Skovbakke, S. S. Pedersen, and R. N. Kok. Body image concerns in patients with an implantable cardioverter defibrillator: a scoping review. Pacing Clin. Electrophysiol. 41(9):1235\u20131260, 2018. https:\/\/doi.org\/10.1111\/pace.13421.","journal-title":"Pacing Clin. Electrophysiol."},{"issue":"2","key":"4297_CR220","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.jacep.2020.08.029","volume":"7","author":"CJ O\u2019Shea","year":"2021","unstructured":"O\u2019Shea, C. J., M. E. Middeldorp, J. M. Hendriks, A. G. Brooks, D. H. Lau, M. Emami, R. Mishima, A. Thiyagarajah, S. Feigofsky, R. Gopinathannair, N. Varma, K. Campbell, and P. Sanders. Remote monitoring alert burden: an analysis of transmission in $$>$$ 26,000 patients. JACC Clin. Electrophysiol. 7(2):226\u2013234, 2021. https:\/\/doi.org\/10.1016\/j.jacep.2020.08.029.","journal-title":"JACC Clin. Electrophysiol."},{"issue":"11","key":"4297_CR221","doi-asserted-by":"publisher","first-page":"009635","DOI":"10.1161\/CIRCEP.121.009635","volume":"14","author":"CJ O\u2019Shea","year":"2021","unstructured":"O\u2019Shea, C. J., M. E. Middeldorp, J. M. Hendriks, A. G. Brooks, C. Harper, G. Thomas, M. Emami, A. Thiyagarajah, S. Feigofsky, R. Gopinathannair, N. Varma, K. Campbell, D. H. Lau, and P. Sanders. Remote monitoring of implantable loop recorders: false-positive alert episode burden. Circ. Arrhythm. Electrophysiol. 14(11):009635, 2021. https:\/\/doi.org\/10.1161\/CIRCEP.121.009635.","journal-title":"Circ. Arrhythm. Electrophysiol."},{"issue":"3","key":"4297_CR222","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1111\/pace.14941","volume":"47","author":"S Covino","year":"2024","unstructured":"Covino, S., and V. Russo. False-positive alarms in patients with implantable loop recorder followed by remote monitoring: a systematic review. Pacing Clin. Electrophysiol. 47(3):406\u2013416, 2024. https:\/\/doi.org\/10.1111\/pace.14941.","journal-title":"Pacing Clin. Electrophysiol."},{"issue":"5","key":"4297_CR223","doi-asserted-by":"publisher","first-page":"032890","DOI":"10.1161\/JAHA.123.032890","volume":"13","author":"ZM Neiman","year":"2024","unstructured":"Neiman, Z. M., M. H. Raitt, G. Rohrbach, and S. S. Dhruva. Monitoring of remotely reprogrammable implantable loop recorders with algorithms to reduce false-positive alerts. J. Am. Heart Assoc. 13(5):032890, 2024. https:\/\/doi.org\/10.1161\/JAHA.123.032890.","journal-title":"J. Am. Heart Assoc."},{"issue":"7","key":"4297_CR224","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.hrthm.2024.10.024","volume":"22","author":"ME Middeldorp","year":"2025","unstructured":"Middeldorp, M. E., G. Thomas, S. H. Kamsani, C. Harper, T. Baykaner, R. Gopinathannair, J. V. Freeman, A. M. Russo, T. F. Deering, and P. Sanders. Use of artificial intelligence algorithms to reduce transmissions in implantable loop recorders. Heart Rhythm. 22(7):241\u2013243, 2025. https:\/\/doi.org\/10.1016\/j.hrthm.2024.10.024.","journal-title":"Heart Rhythm"},{"issue":"9","key":"4297_CR225","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.hrthm.2023.03.1525","volume":"20","author":"AM Ferrick","year":"2023","unstructured":"Ferrick, A. M., S. R. Raj, T. Deneke, P. Kojodjojo, N. Lopez-Cabanillas, H. Abe, S. Boveda, D. S. Chew, J.-O. Choi, N. Dagres, A. S. Dalal, B. E. Dechert, C. G. Frazier-Mills, O. Gilbert, J. K. Han, S. Hewit, C. Kneeland, S. DeEllen Mirza, S. Mittal, R. P. Ricci, M. Runte, S. Sinclair, R. Alkmim-Teixeira, B. Vandenberk, and N. Varma. 2023 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on practical management of the remote device clinic. Heart Rhythm. 20(9):92\u2013144, 2023. https:\/\/doi.org\/10.1016\/j.hrthm.2023.03.1525.","journal-title":"Heart Rhythm"},{"issue":"9","key":"4297_CR226","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/j.hroo.2023.08.001","volume":"4","author":"N Varma","year":"2023","unstructured":"Varma, N. Highlights from the 2023 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on practical management of the remote device clinic. Heart Rhythm O2. 4(9):526\u2013527, 2023. https:\/\/doi.org\/10.1016\/j.hroo.2023.08.001.","journal-title":"Heart Rhythm O2"},{"key":"4297_CR227","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.clinph.2022.07.504","volume":"142","author":"LS Remvig","year":"2022","unstructured":"Remvig, L. S., J. Duun-Henriksen, F. F\u00fcrbass, M. Hartmann, P. F. Viana, A. M. Kappel Overby, S. Weisdorf, M. P. Richardson, S. Beniczky, and T. W. Kjaer. Detecting temporal lobe seizures in ultra long-term subcutaneous EEG using algorithm-based data reduction. Clin. Neurophysiol. 142:86\u201393, 2022. https:\/\/doi.org\/10.1016\/j.clinph.2022.07.504.","journal-title":"Clin. Neurophysiol."},{"issue":"1","key":"4297_CR228","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1111\/epi.18652","volume":"67","author":"S Park","year":"2026","unstructured":"Park, S., J. S. Clark, P. F. Viana, J. Cui, J. Duun-Henriksen, J. Mandrekar, N. Gregg, V. Kremen, G. A. Worrell, M. P. Richardson, and B. H. Brinkmann. Seizure detection using ultra-long-term subcutaneous electroencephalography: a deep learning CNN-BiLSTM approach. Epilepsia. 67(1):437\u2013447, 2026. https:\/\/doi.org\/10.1111\/epi.18652.","journal-title":"Epilepsia"},{"issue":"2","key":"4297_CR229","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1177\/19322968211058148","volume":"17","author":"J Espinoza","year":"2023","unstructured":"Espinoza, J., N. Y. Xu, K. T. Nguyen, and D. C. Klonoff. The need for data standards and implementation policies to integrate CGM data into the electronic health record. J. Diabetes Sci. Technol. 17(2):495\u2013502, 2023. https:\/\/doi.org\/10.1177\/19322968211058148.","journal-title":"J. Diabetes Sci. Technol."},{"key":"4297_CR230","unstructured":"UNEEG Medical. UNEEG Medical Ultra Long-Term EEG Monitoring. UNEEG Medical, 2026. https:\/\/www.uneeg.com\/."},{"key":"4297_CR231","unstructured":"Centers for Medicare & Medicaid Services. Local Coverage Determination (LCD): Cardiac Rhythm Device Evaluation, L34833. Centers for Medicare & Medicaid Services, 2020. https:\/\/www.cms.gov\/medicare-coverage-database\/view\/lcd.aspx?LCDId=34833."},{"key":"4297_CR232","unstructured":"Centers for Medicare & Medicaid Services. Billing and Coding: Cardiac Rhythm Device Evaluation, A56602. Centers for Medicare & Medicaid Services, 2025. https:\/\/www.cms.gov\/medicare-coverage-database\/view\/article.aspx?articleid=56602&ver=39."},{"key":"4297_CR233","unstructured":"Centers for Medicare & Medicaid Services. Local Coverage Determination (LCD): Implantable Continuous Glucose Monitors (I-CGM), L38657. Centers for Medicare & Medicaid Services, 2020. https:\/\/www.cms.gov\/medicare-coverage-database\/view\/lcd.aspx?lcdid=38657."},{"key":"4297_CR234","unstructured":"Centers for Medicare & Medicaid Services. Billing and Coding: Implantable Continuous Glucose Monitors (I-CGM), A58133. Centers for Medicare & Medicaid Services, 2020. https:\/\/www.cms.gov\/medicare-coverage-database\/view\/article.aspx?articleid=58133."},{"key":"4297_CR235","unstructured":"Senseonics Holdings, Inc. Senseonics Holdings, Inc. Reports Fourth Quarter and Full Year 2024 Financial Results. Senseonics Holdings, Inc., 2025. https:\/\/www.senseonics.com\/investor-relations\/news-releases\/2025\/03-03-2025-210657100."},{"key":"4297_CR236","unstructured":"Senseonics Holdings, Inc. Senseonics Holdings, Inc. Reports Fourth Quarter and Full Year 2025 Financial Results. Senseonics Holdings, Inc., 2026. https:\/\/www.senseonics.com\/investor-relations\/news-releases\/2026\/03-02-2026-210131962."},{"key":"4297_CR237","unstructured":"Epiminder. The American Medical Association Creates New Category III CPT Codes for Interpretation and Reporting of Continuous EEG Data. Epiminder, 2025. https:\/\/epiminder.com\/news\/ama-cat-iii-cpt-eeg-interpretation."},{"key":"4297_CR238","unstructured":"American Medical Association. CPT Category III Codes, American Medical Association, 2026. https:\/\/www.ama-assn.org\/system\/files\/cpt-category3-codes-long-descriptors.pdf."},{"key":"4297_CR239","unstructured":"Centers for Medicare & Medicaid Services. Local Coverage Determination (LCD): Category III Codes, L35490. Centers for Medicare & Medicaid Services, 2026. https:\/\/www.cms.gov\/medicare-coverage-database\/view\/lcd.aspx?LCDId=35490."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04297-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-026-04297-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04297-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T02:05:40Z","timestamp":1785463540000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10439-026-04297-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,30]]},"references-count":239,"alternative-id":["4297"],"URL":"https:\/\/doi.org\/10.1007\/s10439-026-04297-1","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,30]]},"assertion":[{"value":"26 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors report no conflicts of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Clinical trial number: not applicable. This work is a narrative review and does not involve human or animal subjects or any other matter requiring ethical approval.","order":2,"name":"Ethics","label":"Ethical Approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}