{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T08:57:03Z","timestamp":1790585823718,"version":"4.1.0"},"reference-count":70,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T00:00:00Z","timestamp":1790467200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T00:00:00Z","timestamp":1790467200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["R15HL175648"],"award-info":[{"award-number":["R15HL175648"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Cardiac vibration signals have been investigated as unobtrusive surrogates of central hemodynamics, but the literature frequently mixes physiological plausibility, association, and clinically meaningful validation. This review evaluates the validation readiness of vibration-based estimation of central hemodynamic parameters, specifically stroke volume (SV), cardiac output (CO), and arterial blood pressure (BP), including cuffless or central BP claims when explicitly reported. Ejection fraction (EF) and pulmonary capillary wedge pressure (PCWP) are also considered as related endpoints for cardiac function and filling pressure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A structured narrative review was conducted across studies using seismocardiography, ballistocardiography, gyrocardiography, and kinocardiography. Evidence was appraised by endpoint using reference standard tier, agreement analysis, calibration burden, and population realism, with emphasis on translational interpretability rather than correlation alone.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Evidence maturity differed substantially by endpoint. The strongest support was found for stroke volume and cardiac output. For these endpoints, weighing-scale ballistocardiography and wearable seismocardiography systems validated against catheterization-based Direct Fick and thermodilution measurements provided the clearest agreement-based evidence within the studies reviewed. Clinically meaningful accuracy remains use-case dependent. Ejection fraction studies were dominated by classification and biomarker-style analyses rather than continuous estimation with agreement reporting. Exploratory early diastolic SCG studies remain limited to associations with echocardiographic relaxation indices, such as tissue Doppler e\u2019, and preload-perturbation responses, rather than direct preload measurement or validated diastolic-function estimation. Blood pressure studies reported promising calibrated error estimates in small healthy cohorts, but none met the International Organization for Standardization (ISO) 81060-2 requirements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Cardiac vibration sensing is not uniformly ready for clinical translation. Stroke volume and cardiac output estimation currently have a relatively more developed validation foundation, whereas ejection fraction and cuffless blood pressure remain pre-validation endpoints that require larger, more clinically realistic studies and stronger agreement-based evaluation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10439-026-04366-5","type":"journal-article","created":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T16:36:41Z","timestamp":1790527001000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Readiness of Hemodynamic Estimation from Cardiac Vibration Signals: An Endpoint-Specific Critical Review"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3317-4811","authenticated-orcid":false,"given":"Peshala T.","family":"Gamage","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasith","family":"Weerasinghe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prasith","family":"Weerasinghe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehmet","family":"Kaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,27]]},"reference":[{"key":"4366_CR1","unstructured":"U.S. Food and Drug Administration. Finapres NOVA Noninvasive Hemodynamic Monitor: 510(k) Summary. U.S. Food and Drug Administration. 2018. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K173916"},{"key":"4366_CR2","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1038\/s41569-025-01127-0","volume":"22","author":"S Min","year":"2025","unstructured":"Min, S., J. An, J. H. Lee, J. H. Kim, D. J. Joe, S. H. Eom, C. D. Yoo, H.-S. Ahn, J.-Y. Hwang, S. Xu, J. A. Rogers, and K. J. Lee. Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation. Nat. Rev. Cardiol. 22:629\u2013648, 2025. https:\/\/doi.org\/10.1038\/s41569-025-01127-0.","journal-title":"Nat. Rev. Cardiol."},{"key":"4366_CR3","doi-asserted-by":"publisher","first-page":"1261022","DOI":"10.3389\/fbioe.2023.1261022","volume":"11","author":"SM Al Younis","year":"2023","unstructured":"Al Younis, S. M., L. J. Hadjileontiadis, C. Stefanini, and A. H. Khandoker. Non-invasive technologies for heart failure, systolic and diastolic dysfunction modeling: a scoping review. Front. Bioeng. Biotechnol. 11:1261022, 2023. https:\/\/doi.org\/10.3389\/fbioe.2023.1261022.","journal-title":"Front. Bioeng. Biotechnol."},{"key":"4366_CR4","doi-asserted-by":"publisher","first-page":"1096859","DOI":"10.3389\/fcvm.2023.1096859","volume":"10","author":"E De Keyzer","year":"2023","unstructured":"De Keyzer, E., A. Hossein, J. Rabineau, M. Morissens, A. Almorad, and P. Van De Borne. Non-invasive cardiac kinetic energy distribution: a new marker of heart failure with impaired ejection fraction (KINO-HF). Front. Cardiovasc. Med. 10:1096859, 2023. https:\/\/doi.org\/10.3389\/fcvm.2023.1096859.","journal-title":"Front. Cardiovasc. Med."},{"key":"4366_CR5","doi-asserted-by":"publisher","first-page":"10479","DOI":"10.1038\/s41598-019-46823-3","volume":"9","author":"A Hossein","year":"2019","unstructured":"Hossein, A., D. C. Mirica, J. Rabineau, J. I. D. Rio, S. Morra, D. Gorlier, A. Nonclercq, P. Van De Borne, and P.-F. Migeotte. Accurate detection of dobutamine-induced haemodynamic changes by kino-cardiography: a randomised double-blind placebo-controlled validation study. Sci. Rep. 9:10479, 2019. https:\/\/doi.org\/10.1038\/s41598-019-46823-3.","journal-title":"Sci. Rep."},{"key":"4366_CR6","doi-asserted-by":"publisher","first-page":"17694","DOI":"10.1038\/s41598-020-74150-5","volume":"10","author":"J Rabineau","year":"2020","unstructured":"Rabineau, J., A. Hossein, F. Landreani, B. Haut, E. Mulder, E. Luchitskaya, J. Tank, E. G. Caiani, P. Van De Borne, and P.-F. Migeotte. Cardiovascular adaptation to simulated microgravity and countermeasure efficacy assessed by ballistocardiography and seismocardiography. Sci. Rep. 10:17694, 2020. https:\/\/doi.org\/10.1038\/s41598-020-74150-5.","journal-title":"Sci. Rep."},{"key":"4366_CR7","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1109\/TBCAS.2015.2405480","volume":"10","author":"M Etemadi","year":"2016","unstructured":"Etemadi, M., O. T. Inan, J. A. Heller, S. Hersek, L. Klein, and S. Roy. A wearable patch to enable long-term monitoring of environmental, activity and hemodynamics variables. IEEE Trans. Biomed. Circuits Syst. 10:280\u2013288, 2016. https:\/\/doi.org\/10.1109\/TBCAS.2015.2405480.","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"4366_CR8","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1152\/japplphysiol.00298.2017","volume":"124","author":"M Etemadi","year":"2018","unstructured":"Etemadi, M., and O. T. Inan. Wearable ballistocardiogram and seismocardiogram systems for health and performance. J. Appl. Physiol. 124:452\u2013461, 2018. https:\/\/doi.org\/10.1152\/japplphysiol.00298.2017.","journal-title":"J. Appl. Physiol."},{"key":"4366_CR9","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1097\/00003246-199906000-00053","volume":"27","author":"E Raaijmakers","year":"1999","unstructured":"Raaijmakers, E., T. J. C. Faes, R. J. P. M. Scholten, H. G. Goovaerts, and R. M. Heethaar. A meta-analysis of three decades of validating thoracic impedance cardiography. Criti. Care Med. 27:1203\u20131213, 1999. https:\/\/doi.org\/10.1097\/00003246-199906000-00053.","journal-title":"Criti. Care Med."},{"key":"4366_CR10","unstructured":"Association for the Advancement of Medical Instrumentation, and International Organization for Standardization. Non-invasive sphygmomanometers: Clinical investigation of intermittent automated measurement type. 2018. https:\/\/www.iso.org\/standard\/73339.html"},{"key":"4366_CR11","doi-asserted-by":"publisher","unstructured":"Srensen, K., A. Verma, A. Blaber, J. Zanetti, S. E. Schmidt, J. Struijk, and K. Tavakolian. Challenges in Using Seismocardiography for Blood Pressure Monitoring. 2017. https:\/\/doi.org\/10.22489\/CinC.2017.026-452","DOI":"10.22489\/CinC.2017.026-452"},{"key":"4366_CR12","doi-asserted-by":"publisher","first-page":"3259","DOI":"10.3906\/elk-1812-121","volume":"27","author":"\u00dc \u015eent\u00fcrk","year":"2019","unstructured":"\u015eent\u00fcrk, \u00dc., K. Polat, and \u0130 Y\u00fcceda\u011f. Towards wearable blood pressure measurement systems from biosignals: a review. Turk. J. Elec. Eng. & Comp. Sci. 27:3259\u20133281, 2019. https:\/\/doi.org\/10.3906\/elk-1812-121.","journal-title":"Turk. J. Elec. Eng. & Comp. Sci."},{"key":"4366_CR13","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.3390\/s26041243","volume":"26","author":"Y Shafti","year":"2026","unstructured":"Shafti, Y., S. Hughes, W. Taylor, M. A. Imran, D. Owens, and S. Ansari. Beyond the cuff: state-of-the-art on cuffless blood pressure monitoring. Sensors. 26:1243, 2026. https:\/\/doi.org\/10.3390\/s26041243.","journal-title":"Sensors"},{"key":"4366_CR14","doi-asserted-by":"publisher","first-page":"3805","DOI":"10.1109\/JSEN.2017.2701349","volume":"17","author":"H Ashouri","year":"2017","unstructured":"Ashouri, H., and O. T. Inan. Automatic detection of seismocardiogram sensor misplacement for robust pre-ejection period estimation in unsupervised settings. IEEE Sensors J. 17:3805\u20133813, 2017. https:\/\/doi.org\/10.1109\/JSEN.2017.2701349.","journal-title":"IEEE Sensors J."},{"key":"4366_CR15","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.121.021893","volume":"10","author":"D Yazdi","year":"2021","unstructured":"Yazdi, D., S. Sridaran, S. Smith, C. Centen, S. Patel, E. Wilson, L. Gillon, S. Kapur, J. A. Tracy, K. Lewine, D. M. Systrom, and C. A. MacRae. Noninvasive scale measurement of stroke volume and cardiac output compared with the direct fick method: a feasibility study. JAHA.10:e021893, 2021. https:\/\/doi.org\/10.1161\/JAHA.121.021893.","journal-title":"JAHA"},{"key":"4366_CR16","doi-asserted-by":"publisher","first-page":"1189732","DOI":"10.3389\/fphys.2023.1189732","volume":"14","author":"TL Steffensen","year":"2023","unstructured":"Steffensen, T. L., F. E. Schjerven, H. M. Flade, I. Kirkeby-Garstad, E. Ingestr\u00f6m, F. S. Solberg, and M. Steinert. Wrist ballistocardiography and invasively recorded blood pressure in healthy volunteers during reclining bike exercise. Front. Physiol. 14:1189732, 2023. https:\/\/doi.org\/10.3389\/fphys.2023.1189732.","journal-title":"Front. Physiol."},{"key":"4366_CR17","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1093\/ehjdh\/ztaf037","volume":"6","author":"A Agam","year":"2025","unstructured":"Agam, A., A. Agam, E. Korsgaard, T. Yding, C. B. Kristensen, R. Mogelvang, K. Kragholm, K. J. G. Emerk, P. S\u00f8gaard, and S. E. Schmidt. Evaluation of seismocardiography in detecting pre-load changes and cardiovascular disease: a comparative study with transthoracic echocardiography. Eur. Heart J. \u2013 Digit. Health. 6:811\u2013821, 2025. https:\/\/doi.org\/10.1093\/ehjdh\/ztaf037.","journal-title":"Eur. Heart J. \u2013 Digit. Health"},{"key":"4366_CR18","doi-asserted-by":"publisher","first-page":"9565","DOI":"10.3390\/s22239565","volume":"22","author":"P Balali","year":"2022","unstructured":"Balali, P., J. Rabineau, A. Hossein, C. Tordeur, O. Debeir, and P. Van De Borne. Investigating cardiorespiratory interaction using ballistocardiography and seismocardiography: a narrative review. Sensors. 22:9565, 2022. https:\/\/doi.org\/10.3390\/s22239565.","journal-title":"Sensors"},{"key":"4366_CR19","doi-asserted-by":"publisher","first-page":"B150","DOI":"10.1016\/j.jacc.2024.09.544","volume":"84","author":"L Klein","year":"2024","unstructured":"Klein, L., A. Carek, and O. Inan. TCT-465 study design and interim results of the non-invasive seismocardiogram in cardiovascular monitoring for heart failure I (SEISMIC-HF I) study. J. Am. Coll. Cardiol. 84:B150, 2024. https:\/\/doi.org\/10.1016\/j.jacc.2024.09.544.","journal-title":"J. Am. Coll. Cardiol."},{"key":"4366_CR20","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1007\/s10741-025-10514-1","volume":"30","author":"B Cheema","year":"2025","unstructured":"Cheema, B., and A. Tibrewala. SEISMIC-HF 1: key findings from AHA24 and implications for remote cardiac monitoring. Heart Fail. Rev. 30:1099\u20131101, 2025. https:\/\/doi.org\/10.1007\/s10741-025-10514-1.","journal-title":"Heart Fail. Rev."},{"key":"4366_CR21","doi-asserted-by":"publisher","unstructured":"Klein, L., M. Fudim, M. Etemadi, R. Gordon, A. Tibrewala, J. Hernandez-Montfort, P. McCann, L. Zier, K. Shah, A. Rollins, D. Karia, A. Quyyumi, S. R. Motiwala, N. Diakos, J. Rommel, A. P. Ambrosy, V. G. Ganti, P. Soni, K. Larimer, A. M. Carek, and O. T. Inan. Noninvasive pulmonary capillary wedge pressure estimation in heart failure patients with the use of wearable sensing and AI. JACC: Heart Fail. 13:102513, 2025. https:\/\/doi.org\/10.1016\/j.jchf.2025.102513","DOI":"10.1016\/j.jchf.2025.102513"},{"key":"4366_CR22","doi-asserted-by":"publisher","unstructured":"Crow, R. S., P. Hannan, D. Jacobs, L. Hedquist, and D. M. Salerno. Relationship between seismocardiogram andechocardiogram for events inthe cardiac cycle. Am. J. Noninvas. Cardiol. 39\u201346, 2017. https:\/\/doi.org\/10.1159\/000470156","DOI":"10.1159\/000470156"},{"key":"4366_CR23","doi-asserted-by":"publisher","unstructured":"Jafari Tadi, M., E. Lehtonen, A. Saraste, J. Tuominen, J. Koskinen, M. Ter\u00e4s, J. Airaksinen, M. P\u00e4nk\u00e4\u00e4l\u00e4, and T. Koivisto. Gyrocardiography: a new non-invasive monitoring method for the assessment of cardiac mechanics and the estimation of hemodynamic variables. Sci. Rep. 7:6823, 2017. https:\/\/doi.org\/10.1038\/s41598-017-07248-y","DOI":"10.1038\/s41598-017-07248-y"},{"key":"4366_CR24","doi-asserted-by":"publisher","unstructured":"Dehkordi, P., K. Tavakolian, T. Zhao, V. Zakeri, and F. Khosrow-khavar. Estimation of cardiac time intervals from the mechanical activity of the heart using machine learning. 2019. https:\/\/doi.org\/10.22489\/CinC.2019.328","DOI":"10.22489\/CinC.2019.328"},{"key":"4366_CR25","doi-asserted-by":"publisher","unstructured":"Giovangrandi, L., O. T. Inan, R. M. Wiard, M. Etemadi, and G. T. A. Kovacs. Ballistocardiography: a method worth revisiting. 2011. https:\/\/doi.org\/10.1109\/IEMBS.2011.6091062","DOI":"10.1109\/IEMBS.2011.6091062"},{"key":"4366_CR26","doi-asserted-by":"publisher","first-page":"201","DOI":"10.2174\/1874120701004010201","volume":"4","author":"E Pinheiro","year":"2010","unstructured":"Pinheiro, E., O. Postolache, and P. Gir\u00e3o. Theory and developments in an unobtrusive cardiovascular system representation: ballistocardiography. TOBEJ. 4:201\u2013216, 2010. https:\/\/doi.org\/10.2174\/1874120701004010201.","journal-title":"TOBEJ"},{"key":"4366_CR27","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1088\/0967-3334\/30\/3\/003","volume":"30","author":"OT Inan","year":"2009","unstructured":"Inan, O. T., M. Etemadi, A. Paloma, L. Giovangrandi, and G. T. A. Kovacs. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph. Physiol. Meas. 30:261\u2013274, 2009. https:\/\/doi.org\/10.1088\/0967-3334\/30\/3\/003.","journal-title":"Physiol. Meas."},{"key":"4366_CR28","doi-asserted-by":"publisher","DOI":"10.2196\/25996","volume":"8","author":"AR Malik","year":"2021","unstructured":"Malik, A. R., and J. Boger. Zero-effort ambient heart rate monitoring using ballistocardiography detected through a seat cushion: prototype development and preliminary study. JMIR Rehabil Assist Technol.8:e25996, 2021. https:\/\/doi.org\/10.2196\/25996.","journal-title":"JMIR Rehabil Assist Technol"},{"key":"4366_CR29","doi-asserted-by":"publisher","unstructured":"Garci, J. A novel wearable insole BCG as a surrogate of the standard vertical weighing scale BCG. 2023. https:\/\/doi.org\/10.22489\/CinC.2023.396","DOI":"10.22489\/CinC.2023.396"},{"key":"4366_CR30","doi-asserted-by":"publisher","first-page":"10666","DOI":"10.1038\/s41598-019-46936-9","volume":"9","author":"P Yousefian","year":"2019","unstructured":"Yousefian, P., S. Shin, A. Mousavi, C.-S. Kim, R. Mukkamala, D.-G. Jang, B.-H. Ko, J. Lee, U. K. Kwon, Y. H. Kim, and J.-O. Hahn. The potential of wearable limb ballistocardiogram in blood pressure monitoring via pulse transit time. Sci. Rep. 9:10666, 2019. https:\/\/doi.org\/10.1038\/s41598-019-46936-9.","journal-title":"Sci. Rep."},{"key":"4366_CR31","doi-asserted-by":"publisher","first-page":"2657","DOI":"10.1109\/TBME.2015.2440291","volume":"62","author":"C-S Kim","year":"2015","unstructured":"Kim, C.-S., A. M. Carek, R. Mukkamala, O. T. Inan, and J.-O. Hahn. Ballistocardiogram as proximal timing reference for pulse transit time measurement: potential for cuffless blood pressure monitoring. IEEE Trans. Biomed. Eng. 62:2657\u20132664, 2015. https:\/\/doi.org\/10.1109\/TBME.2015.2440291.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"4366_CR32","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1161\/CIRCRESAHA.122.322389","volume":"132","author":"A Hughes","year":"2023","unstructured":"Hughes, A., M. M. H. Shandhi, H. Master, J. Dunn, and E. Brittain. Wearable devices in cardiovascular medicine. Circ. Res. 132:652\u2013670, 2023. https:\/\/doi.org\/10.1161\/CIRCRESAHA.122.322389.","journal-title":"Circ. Res."},{"key":"4366_CR33","doi-asserted-by":"publisher","unstructured":"Taebi, A., B. E. Solar, A. J. Bomar, R. H. Sandler, and H. A. Mansy. Recent advances in seismocardiography. Vibration 2:64\u201386, 2019. https:\/\/doi.org\/10.3390\/vibration2010005","DOI":"10.3390\/vibration2010005"},{"key":"4366_CR34","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.122.026067","volume":"11","author":"VG Ganti","year":"2022","unstructured":"Ganti, V. G., A. H. Gazi, S. An, A. V. Srivatsa, B. N. Nevius, C. J. Nichols, A. M. Carek, M. Fares, M. Abdulkarim, T. Hussain, F. G. Greil, M. Etemadi, O. T. Inan, and A. Tandon. Wearable seismocardiography-based assessment of stroke volume in congenital heart disease. JAHA.11:e026067, 2022. https:\/\/doi.org\/10.1161\/JAHA.122.026067.","journal-title":"JAHA"},{"key":"4366_CR35","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.amjcard.2025.09.037","volume":"259","author":"J Wang","year":"2026","unstructured":"Wang, J., S. M. Nouraie, N. J. Kelly, and S. Y. Chan. Deep Learning predicts cardiac output from seismocardiographic signals in heart failure. Am. J. Cardiol. 259:97\u2013104, 2026. https:\/\/doi.org\/10.1016\/j.amjcard.2025.09.037.","journal-title":"Am. J. Cardiol."},{"key":"4366_CR36","doi-asserted-by":"publisher","unstructured":"Rahman, M. M., A. Mann, and A. Taebi. ECG-Free assessment of cardiac valve events using seismocardiography. 2024. https:\/\/doi.org\/10.1109\/BSN63547.2024.10780525","DOI":"10.1109\/BSN63547.2024.10780525"},{"key":"4366_CR37","doi-asserted-by":"publisher","first-page":"1643","DOI":"10.1088\/0967-3334\/33\/10\/1643","volume":"33","author":"K Pandia","year":"2012","unstructured":"Pandia, K., O. T. Inan, G. T. A. Kovacs, and L. Giovangrandi. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer. Physiol. Meas. 33:1643\u20131660, 2012. https:\/\/doi.org\/10.1088\/0967-3334\/33\/10\/1643.","journal-title":"Physiol. Meas."},{"key":"4366_CR38","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.758727","volume":"12","author":"P Dehkordi","year":"2021","unstructured":"Dehkordi, P., E. P. Bauer, K. Tavakolian, Z. G. Xiao, A. P. Blaber, and F. Khosrow-Khavar. Detecting coronary artery disease using rest seismocardiography and gyrocardiography. Front. Physiol.12:758727, 2021. https:\/\/doi.org\/10.3389\/fphys.2021.758727.","journal-title":"Front. Physiol."},{"key":"4366_CR39","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.725716","volume":"12","author":"E Andreozzi","year":"2021","unstructured":"Andreozzi, E., G. D. Gargiulo, D. Esposito, and P. Bifulco. A novel broadband forcecardiography sensor for simultaneous monitoring of respiration, infrasonic cardiac vibrations and heart sounds. Front. Physiol.12:725716, 2021. https:\/\/doi.org\/10.3389\/fphys.2021.725716.","journal-title":"Front. Physiol."},{"key":"4366_CR40","doi-asserted-by":"publisher","unstructured":"Lahdenoja, O., T. Hurnanen, M. Jafari Tadi, M. Pankaala, and T. Koivisto. Heart rate variability estimation with joint accelerometer and gyroscope sensing. 2016. https:\/\/doi.org\/10.22489\/CinC.2016.209-166","DOI":"10.22489\/CinC.2016.209-166"},{"key":"4366_CR41","doi-asserted-by":"publisher","unstructured":"Skoric, \"James, Y. D\u2019Mello, N. Clairmonte, A. McLean, S. Hakim, E. Aboulezz, M. Lortie, and D. V. Plant\". Cuff-less estimation of blood pressure from vibrational cardiography using a convolutional neural network. 2022. https:\/\/doi.org\/10.22489\/CinC.2022.110","DOI":"10.22489\/CinC.2022.110"},{"key":"4366_CR42","doi-asserted-by":"publisher","first-page":"621","DOI":"10.3390\/bios14120621","volume":"14","author":"A Zienkiewicz","year":"2024","unstructured":"Zienkiewicz, A., V. Korhonen, V. Kiviniemi, and T. Myllyl\u00e4. Continuous estimation of blood pressure by utilizing seismocardiogram signal features in relation to electrocardiogram. Biosensors. 14:621, 2024. https:\/\/doi.org\/10.3390\/bios14120621.","journal-title":"Biosensors"},{"key":"4366_CR43","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/s12938-020-00837-5","volume":"20","author":"A Hossein","year":"2021","unstructured":"Hossein, A., J. Rabineau, D. Gorlier, F. Pinki, P. Van De Borne, A. Nonclercq, and P.-F. Migeotte. Effects of acquisition device, sampling rate, and record length on kinocardiography during position-induced haemodynamic changes. BioMed. Eng. OnLine. 20:3, 2021. https:\/\/doi.org\/10.1186\/s12938-020-00837-5.","journal-title":"BioMed. Eng. OnLine"},{"key":"4366_CR44","doi-asserted-by":"publisher","first-page":"4925","DOI":"10.1002\/ehf2.13522","volume":"8","author":"C Herkert","year":"2021","unstructured":"Herkert, C., P.-F. Migeotte, A. Hossein, R. F. Spee, and H. M. C. Kemps. The kinocardiograph for assessment of changes in haemodynamic load in patients with chronic heart failure with reduced ejection fraction. ESC Heart Fail. 8:4925\u20134932, 2021. https:\/\/doi.org\/10.1002\/ehf2.13522.","journal-title":"ESC Heart Fail."},{"key":"4366_CR45","doi-asserted-by":"publisher","first-page":"167","DOI":"10.3390\/bioengineering9040167","volume":"9","author":"E Andreozzi","year":"2022","unstructured":"Andreozzi, E., J. Centracchio, D. Esposito, and P. Bifulco. A comparison of heart pulsations provided by forcecardiography and double integration of seismocardiogram. Bioengineering. 9:167, 2022. https:\/\/doi.org\/10.3390\/bioengineering9040167.","journal-title":"Bioengineering"},{"key":"4366_CR46","doi-asserted-by":"publisher","first-page":"1608","DOI":"10.3390\/s25051608","volume":"25","author":"S Parlato","year":"2025","unstructured":"Parlato, S., J. Centracchio, E. Cinotti, G. D. Gargiulo, D. Esposito, P. Bifulco, and E. Andreozzi. A flexible PVDF sensor for forcecardiography. Sensors. 25:1608, 2025. https:\/\/doi.org\/10.3390\/s25051608.","journal-title":"Sensors"},{"key":"4366_CR47","unstructured":"Tavakolian, K., A. P. Blaber, B. Ngai, and B. Kaminska. Estimation of hemodynamic parameters from seismocardiogram. 2010. https:\/\/ieeexplore.ieee.org\/document\/5738158"},{"key":"4366_CR48","doi-asserted-by":"publisher","unstructured":"Inan, O. T., M. Baran Pouyan, A. Q. Javaid, S. Dowling, M. Etemadi, A. Dorier, J. A. Heller, A. O. Bicen, S. Roy, T. De Marco, and L. Klein. Novel wearable seismocardiography and machine learning algorithms can assess clinical status of heart failure patients. Circ: Heart Fail. 11:e004313, 2018. https:\/\/doi.org\/10.1161\/CIRCHEARTFAILURE.117.004313","DOI":"10.1161\/CIRCHEARTFAILURE.117.004313"},{"key":"4366_CR49","doi-asserted-by":"publisher","unstructured":"Trefn\u00fd, Z. M., J. Sva\u010dinka, O. Kittnar, J. Slav\u00ed\u010dek, M. Trefn\u00fd, E. Filatova, J. A. Tich\u00fd, P. Smr\u010dka, M. Stork, and M. Lou\u010dka. Quantitative Ballistocardiography (Q-BCG) for Measurement of Cardiovascular Dynamics. Physio.l Res. 617\u2013625, 2011. https:\/\/doi.org\/10.33549\/physiolres.931993","DOI":"10.33549\/physiolres.931993"},{"key":"4366_CR50","doi-asserted-by":"publisher","unstructured":"Ahmed, M. H., Y. Weerasinghe, M. Grillo, A. Taebi, M. Kaya, and P. Thibbotuwawa Gamage. Feasibility of Left Ventricular Function Assessment via Precordial Vibrations in Heart Failure Patients. 2024. https:\/\/doi.org\/10.1115\/IMECE2024-145486","DOI":"10.1115\/IMECE2024-145486"},{"key":"4366_CR51","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1093\/ehjdh\/ztac043","volume":"3","author":"A Agam","year":"2022","unstructured":"Agam, A., P. S\u00f8gaard, K. Kragholm, A. S. Jensen, K. S\u00f8rensen, J. Hansen, and S. Schmidt. Correlation between diastolic seismocardiography variables and echocardiography variables. Eur. Heart J. \u2013 Digit. Health. 3:465\u2013472, 2022. https:\/\/doi.org\/10.1093\/ehjdh\/ztac043.","journal-title":"Eur. Heart J. \u2013 Digit. Health"},{"key":"4366_CR52","doi-asserted-by":"publisher","first-page":"1671","DOI":"10.1038\/s41598-024-52300-3","volume":"14","author":"JN Svens\u00f8y","year":"2024","unstructured":"Svens\u00f8y, J. N., E. Alonso, A. Elola, R. Bj\u00f8rnerheim, J. R\u00e6der, E. Aramendi, and L. Wik. Cardiac output estimation using ballistocardiography: a feasibility study in healthy subjects. Sci. Rep. 14:1671, 2024. https:\/\/doi.org\/10.1038\/s41598-024-52300-3.","journal-title":"Sci. Rep."},{"key":"4366_CR53","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"327","author":"J Martin Bland","year":"1986","unstructured":"Martin Bland, J., and A. DouglasG. Statistical methods for assessing agreement between two methods of clinical measuremENT. The Lancet. 327:307\u2013310, 1986. https:\/\/doi.org\/10.1016\/S0140-6736(86)90837-8.","journal-title":"The Lancet."},{"key":"4366_CR54","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LAH Critchley","year":"1999","unstructured":"Critchley, L. A. H., and J. A. J. H. Critchley. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. Comput. 15:85\u201391, 1999. https:\/\/doi.org\/10.1023\/A:1009982611386.","journal-title":"J. Clin. Monit. Comput."},{"key":"4366_CR55","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1213\/ANE.0b013e3181f08a5b","volume":"111","author":"LA Critchley","year":"2010","unstructured":"Critchley, L. A., A. Lee, and A.M.-H. Ho. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth. Analg. 111:1180\u20131192, 2010. https:\/\/doi.org\/10.1213\/ANE.0b013e3181f08a5b.","journal-title":"Anesth. Analg."},{"key":"4366_CR56","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2025.109179","volume":"113","author":"F Santucci","year":"2026","unstructured":"Santucci, F., E. Maiorana, C. Romano, A. Nusca, G. P. Ussia, E. Schena, R. Setola, and C. Massaroni. Multi-site seismocardiographic measurements for the estimation of cardiac output in patients with aortic stenosis. Biomed. Signal Process. Control.113:109179, 2026. https:\/\/doi.org\/10.1016\/j.bspc.2025.109179.","journal-title":"Biomed. Signal Process. Control"},{"key":"4366_CR57","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ae178c","volume":"46","author":"R Dhar","year":"2025","unstructured":"Dhar, R., M. R. Hossen, P. T. Gamage, R. H. Sandler, N. Y. Raval, R. J. Mentz, and H. A. Mansy. AI-based approach for heart failure readmission prediction using SCG, ECG, and GSR signals. Physiol. Meas.46:115003, 2025. https:\/\/doi.org\/10.1088\/1361-6579\/ae178c.","journal-title":"Physiol. Meas."},{"key":"4366_CR58","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1038\/s41598-020-79933-4","volume":"11","author":"S Morra","year":"2021","unstructured":"Morra, S., A. Hossein, J. Rabineau, D. Gorlier, J. Racape, P.-F. Migeotte, and P. Van De Borne. Assessment of left ventricular twist by 3D ballistocardiography and seismocardiography compared with 2D STI echocardiography in a context of enhanced inotropism in healthy subjects. Sci. Rep. 11:683, 2021. https:\/\/doi.org\/10.1038\/s41598-020-79933-4.","journal-title":"Sci. Rep."},{"key":"4366_CR59","doi-asserted-by":"publisher","unstructured":"Tavakolian, K., G. Portacio, N. R. Tamddondoust, G. Jahns, B. Ngai, G. A. Dumont, and A. P. Blaber. Myocardial contractility: a seismocardiography approach. 2012. https:\/\/doi.org\/10.1109\/EMBC.2012.6346795","DOI":"10.1109\/EMBC.2012.6346795"},{"key":"4366_CR60","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1109\/TBME.2018.2797239","volume":"65","author":"C-S Kim","year":"2018","unstructured":"Kim, C.-S., A. M. Carek, O. T. Inan, R. Mukkamala, and J.-O. Hahn. Ballistocardiogram-based approach to cuffless blood pressure monitoring: proof of concept and potential challenges. IEEE Trans. Biomed. Eng. 65:2384\u20132391, 2018. https:\/\/doi.org\/10.1109\/TBME.2018.2797239.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"4366_CR61","doi-asserted-by":"publisher","unstructured":"Wang, E. J., J. Zhu, M. Jain, T.-J. Lee, E. Saba, L. Nachman, and S. N. Patel. Seismo: Blood pressure monitoring using built-in smartphone accelerometer and camera. 2018. https:\/\/doi.org\/10.1145\/3173574.3173999","DOI":"10.1145\/3173574.3173999"},{"key":"4366_CR62","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3659599","volume":"8","author":"L Wang","year":"2024","unstructured":"Wang, L., X. Wang, Y. Zhang, X. Ma, H. Dai, Y. Zhang, Z. Li, and T. Gu. Accurate blood pressure measurement using smartphone\u2019s built-in accelerometer. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 8:1\u201328, 2024. https:\/\/doi.org\/10.1145\/3659599.","journal-title":"Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."},{"key":"4366_CR63","doi-asserted-by":"publisher","first-page":"2318","DOI":"10.3390\/s23042318","volume":"23","author":"S-H Liu","year":"2023","unstructured":"Liu, S.-H., Y.-R. Wu, W. Chen, C.-H. Su, and C.-L. Chin. Using ballistocardiogram and impedance plethysmogram for minimal contact measurement of blood pressure based on a body weight-fat scale. Sensors. 23:2318, 2023. https:\/\/doi.org\/10.3390\/s23042318.","journal-title":"Sensors"},{"key":"4366_CR64","doi-asserted-by":"publisher","unstructured":"Azad, M. K., J. D\u2019Angelo, P. T. Gamage, S. Ismail, R. H. Sandler, and H. A. Mansy. Spatial Distribution of Seismocardiographic Signals. In: Biomedical Signal Processing, edited by I. Obeid, I. Selesnick, and J. Picone. Cham: Springer International Publishing, 2021, pp. 129\u2013159. https:\/\/doi.org\/10.1007\/978-3-030-67494-6_5","DOI":"10.1007\/978-3-030-67494-6_5"},{"key":"4366_CR65","doi-asserted-by":"publisher","first-page":"S92","DOI":"10.1016\/j.cardfail.2020.09.269","volume":"26","author":"RH Sandler","year":"2020","unstructured":"Sandler, R. H., M. K. Azad, J. D\u2019Angelo, P. Gamage, N. Y. Raval, R. J. Mentz, and H. A. Mansy. Documenting spatial variation of SCG signals for optimal sensor placement. J. Card. Fail. 26:S92, 2020. https:\/\/doi.org\/10.1016\/j.cardfail.2020.09.269.","journal-title":"J. Card. Fail."},{"key":"4366_CR66","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1109\/JSEN.2016.2643780","volume":"17","author":"AD Wiens","year":"2017","unstructured":"Wiens, A. D., A. Johnson, and O. T. Inan. Wearable sensing of cardiac timing intervals from cardiogenic limb vibration signals. IEEE Sensors J. 17:1463\u20131470, 2017. https:\/\/doi.org\/10.1109\/JSEN.2016.2643780.","journal-title":"IEEE Sensors J."},{"key":"4366_CR67","doi-asserted-by":"publisher","first-page":"11787","DOI":"10.1038\/s41598-023-38607-7","volume":"13","author":"MM Rahman","year":"2023","unstructured":"Rahman, M. M., J. Cook, and A. Taebi. Non-contact heart vibration measurement using computer vision-based seismocardiography. Sci. Rep. 13:11787, 2023. https:\/\/doi.org\/10.1038\/s41598-023-38607-7.","journal-title":"Sci. Rep."},{"key":"4366_CR68","doi-asserted-by":"publisher","first-page":"1237043","DOI":"10.3389\/fcvm.2023.1237043","volume":"10","author":"M Elgendi","year":"2023","unstructured":"Elgendi, M., W. Wu, C. Guan, and C. Menon. Revolutionizing smartphone gyrocardiography for heart rate monitoring: overcoming clinical validation hurdles. Front. Cardiovasc. Med. 10:1237043, 2023. https:\/\/doi.org\/10.3389\/fcvm.2023.1237043.","journal-title":"Front. Cardiovasc. Med."},{"key":"4366_CR69","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1038\/s41746-023-00835-6","volume":"6","author":"L Zhao","year":"2023","unstructured":"Zhao, L., C. Liang, Y. Huang, G. Zhou, Y. Xiao, N. Ji, Y.-T. Zhang, and N. Zhao. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. npj Digit. Med. 6:93, 2023. https:\/\/doi.org\/10.1038\/s41746-023-00835-6.","journal-title":"npj Digit. Med."},{"key":"4366_CR70","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1038\/s41597-025-05287-z","volume":"12","author":"J Zhan","year":"2025","unstructured":"Zhan, J., Z. Li, X. Wu, C. Zhang, T. Zhao, K. Chen, and Z. Lu. A multi-pathology ballistocardiogram dataset for cardiac function monitoring and arrhythmia assessment. Sci. Data. 12:963, 2025. https:\/\/doi.org\/10.1038\/s41597-025-05287-z.","journal-title":"Sci. Data"}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04366-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-026-04366-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04366-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T08:16:34Z","timestamp":1790583394000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10439-026-04366-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,27]]},"references-count":70,"alternative-id":["4366"],"URL":"https:\/\/doi.org\/10.1007\/s10439-026-04366-5","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,27]]},"assertion":[{"value":"17 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article is a review of previously published literature. No human participants or animals were involved in this work, and ethics approval was not required.","order":2,"name":"Ethics","label":"Ethical Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent to Participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":4,"name":"Ethics","label":"Consent for Publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors recognize the importance of citation diversity in biomedical engineering and made reasonable efforts during manuscript preparation to include foundational and recent work from multiple research groups, methodologies, and application areas. A formal demographic analysis of the reference list was not performed.","order":5,"name":"Ethics","label":"Citation Diversity Statement","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":6,"name":"Ethics","label":"Clinical Trial Number","group":{"name":"EthicsHeading","label":"Declarations"}}]}}