{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:14:55Z","timestamp":1792782895348,"version":"4.5.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:00:00Z","timestamp":1791936000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:00:00Z","timestamp":1791936000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"NIBIB","award":["BRP U01 EB026414"],"award-info":[{"award-number":["BRP U01 EB026414"]}],"id":[{"id":"https:\/\/ror.org\/00372qc85","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Biomed Eng"],"DOI":"10.1007\/s10439-026-04399-w","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:53:47Z","timestamp":1792029227000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Strain-Based Assessment of Post-TAVR Left Bundle Branch Block in Bicuspid Aortic Valve Using Patient-Specific Computational Modeling"],"prefix":"10.1007","author":[{"given":"Salwa","family":"Anam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon","family":"Kovarovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Puja","family":"Parikh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashraf","family":"Hamdan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rami","family":"Haj-Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4014-2308","authenticated-orcid":false,"given":"Danny","family":"Bluestein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,14]]},"reference":[{"key":"4399_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12186056","author":"M Szotek","year":"2023","unstructured":"Szotek, M., \u0141 Dru\u017cbicki, K. Sabatowski, G. R. Amoroso, K. De Schouwer, and P. T. Matusik. Transcatheter aortic valve implantation and cardiac conduction abnormalities: prevalence, risk factors and management. J. Clin. Med. 2023. https:\/\/doi.org\/10.3390\/jcm12186056.","journal-title":"J. Clin. Med."},{"key":"4399_CR2","doi-asserted-by":"publisher","first-page":"e008239","DOI":"10.1161\/CIRCEP.119.008239","volume":"13","author":"NY Tan","year":"2020","unstructured":"Tan, N. Y., C. M. Witt, J. K. Oh, and Y.-M. Cha. Left bundle branch block. Circulat. Arrhythm. Electrophysiol. 13:e008239, 2020. https:\/\/doi.org\/10.1161\/CIRCEP.119.008239.","journal-title":"Circulat. Arrhythm. Electrophysiol."},{"key":"4399_CR3","doi-asserted-by":"publisher","DOI":"10.15420\/icr.2020.07","volume":"15","author":"SI Lin","year":"2020","unstructured":"Lin, S. I., M. Miura, A. P. Tagliari, Y. H. Lee, S. Shirai, R. Puri, F. Maisano, and M. Taramasso. Intraventricular conduction disturbances after transcatheter aortic valve implantation. Interv. Cardiol.15:e11, 2020. https:\/\/doi.org\/10.15420\/icr.2020.07.","journal-title":"Interv. Cardiol."},{"key":"4399_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcct.2020.10.002","author":"A Hamdan","year":"2020","unstructured":"Hamdan, A., M. Nassar, E. Schwammenthal, G. Perlman, Z. Arow, J. Lessick, A. Kerner, A. Barsheshet, H. V. Assa, A. Assali, et al. Short membranous septum length in bicuspid aortic valve stenosis increases the risk of conduction disturbances. J. Cardiovasc. Comput. Tomograph. 2020. https:\/\/doi.org\/10.1016\/j.jcct.2020.10.002.","journal-title":"J. Cardiovasc. Comput. Tomograph."},{"key":"4399_CR5","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.3389\/fphys.2018.01921","volume":"9","author":"T Liu","year":"2018","unstructured":"Liu, T., M. Xie, Q. Lv, Y. Li, L. Fang, L. Zhang, W. Deng, and J. Wang. Bicuspid aortic valve: an update in morphology, genetics, biomarker, complications. Imag. Diagnos. Treatment. Front. Physiol. 9:1921, 2018. https:\/\/doi.org\/10.3389\/fphys.2018.01921.","journal-title":"Imag. Diagnos. Treatment. Front. Physiol."},{"key":"4399_CR6","doi-asserted-by":"publisher","first-page":"1576","DOI":"10.1111\/jce.15525","volume":"33","author":"H Miyashita","year":"2022","unstructured":"Miyashita, H., N. Moriyama, F. Yamanaka, S. Saito, H. Lehtola, J. Piuhola, M. Niemel\u00e4, and M. Laine. Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis. J. Cardiovasc. Electrophysiol. 33:1576\u20131586, 2022. https:\/\/doi.org\/10.1111\/jce.15525.","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"4399_CR7","doi-asserted-by":"publisher","first-page":"452","DOI":"10.21037\/acs-2020-av-23","volume":"9","author":"S Chen","year":"2020","unstructured":"Chen, S., K. H. Chau, and T. M. Nazif. The incidence and impact of cardiac conduction disturbances after transcatheter aortic valve replacement. Ann. Cardiothorac. Surg. 9:452\u2013467, 2020. https:\/\/doi.org\/10.21037\/acs-2020-av-23.","journal-title":"Ann. Cardiothorac. Surg."},{"key":"4399_CR8","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1111\/jce.16782","volume":"36","author":"AR Atreya","year":"2025","unstructured":"Atreya, A. R., P. Teerawongsakul, M. Ghannam, R. Latchamsetty, S. Jame, K. Jongnarangsin, and T. Ananwattanasuk. The association between newly acquired permanent left bundle branch block following transcatheter aortic valve replacement and new-onset cardiomyopathy. J. Cardiovasc. Electrophysiol. 36:2196\u20132204, 2025. https:\/\/doi.org\/10.1111\/jce.16782.","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"4399_CR9","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.125.015441","author":"N Singh","year":"2026","unstructured":"Singh, N., D. J. Cohen, S. Chen, M. A. Shah, A. Stebbins, A. S. Kosinski, L. Brothers, S. Vemulapalli, A. J. Kirtane, J. M. Dizon, et al. Outcomes of patients with new left bundle branch block after TAVR: TVT registry insights. Circ. Cardiovasc. Interv. 2026. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.125.015441.","journal-title":"Circ. Cardiovasc. Interv."},{"key":"4399_CR10","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.893878","volume":"9","author":"K Kim","year":"2022","unstructured":"Kim, K., Y. G. Ko, C. Y. Shim, J. Ryu, Y. J. Lee, J. Seo, S. J. Lee, I. Cho, S. J. Hong, C. M. Ahn, et al. Impact of new-onset persistent left bundle branch block on reverse cardiac remodeling and clinical outcomes after transcatheter aortic valve replacement. Front. Cardiovasc. Med.9:893878, 2022. https:\/\/doi.org\/10.3389\/fcvm.2022.893878.","journal-title":"Front. Cardiovasc. Med."},{"key":"4399_CR11","unstructured":"FEops TAVI Guide platform. https:\/\/feops.com."},{"key":"4399_CR12","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.005344","volume":"11","author":"G Rocatello","year":"2018","unstructured":"Rocatello, G., N. El Faquir, G. De Santis, F. Iannaccone, J. Bosmans, O. De Backer, L. Sondergaard, P. Segers, M. De Beule, P. de Jaegere, et al. Patient-specific computer simulation to elucidate the role of contact pressure in the development of new conduction abnormalities after catheter-based implantation of a self-expanding aortic valve. Circ. Cardiovasc. Interv.11:e005344, 2018. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.117.005344.","journal-title":"Circ. Cardiovasc. Interv."},{"key":"4399_CR13","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.carrev.2023.01.015","volume":"51","author":"C Dowling","year":"2023","unstructured":"Dowling, C., R. Gooley, L. McCormick, R. P. Sharma, A. C. Yeung, W. F. Fearon, J. Dargan, F. Khan, S. Firoozi, and S. J. Brecker. Ongoing experience with patient-specific computer simulation of transcatheter aortic valve replacement in bicuspid aortic valve. Cardiovasc. Revascularizat. Med. 51:31\u201337, 2023. https:\/\/doi.org\/10.1016\/j.carrev.2023.01.015.","journal-title":"Cardiovasc. Revascularizat. Med."},{"key":"4399_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.shj.2022.100010","author":"C Dowling","year":"2022","unstructured":"Dowling, C., R. Gooley, L. McCormick, H. N. Rashid, J. Dargan, F. Khan, S. Firoozi, and S. J. Brecker. Patient-specific computer simulation to predict conduction disturbance with current-generation self-expanding transcatheter heart valves. Struct. Heart. 2022. https:\/\/doi.org\/10.1016\/j.shj.2022.100010.","journal-title":"Struct. Heart"},{"key":"4399_CR15","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.jcin.2019.07.032","volume":"13","author":"C Dowling","year":"2020","unstructured":"Dowling, C., S. Firoozi, and S. J. Brecker. First-in-human experience with patient-specific computer simulation of TAVR in bicuspid aortic valve morphology. JACC Cardiovasc. Intervent. 13:184\u2013192, 2020. https:\/\/doi.org\/10.1016\/j.jcin.2019.07.032.","journal-title":"JACC Cardiovasc. Intervent."},{"key":"4399_CR16","doi-asserted-by":"publisher","DOI":"10.1161\/circimaging.119.009178","volume":"12","author":"C Dowling","year":"2019","unstructured":"Dowling, C., A. M. Bavo, N. El Faquir, P. Mortier, P. de Jaegere, O. De Backer, L. Sondergaard, P. Ruile, D. Mylotte, H. McConkey, et al. Patient-specific computer simulation of transcatheter aortic valve replacement in bicuspid aortic valve morphology. Circ. Cardiovasc. Imaging.12:e009178, 2019. https:\/\/doi.org\/10.1161\/circimaging.119.009178.","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"4399_CR17","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1016\/S0735-1097(21)02538-9","volume":"77","author":"K Sivakumar Sri","year":"2021","unstructured":"Sivakumar Sri, K., B. Yeats, V. Polsani, P. Yadav, V. Thourani, and L. Dasi. Predicting the risk of conduction abnormalities post-TAVR using preoperative computational modeling. J. Am. College Cardiol. 77:1179\u20131179, 2021. https:\/\/doi.org\/10.1016\/S0735-1097(21)02538-9.","journal-title":"J. Am. College Cardiol."},{"key":"4399_CR18","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s10237-018-1069-9","volume":"18","author":"OM McGee","year":"2019","unstructured":"McGee, O. M., P. S. Gunning, A. McNamara, and L. M. McNamara. The impact of implantation depth of the Lotus\u2122 valve on mechanical stress in close proximity to the bundle of His. Biomech. Model. Mechanobiol. 18:79\u201388, 2019. https:\/\/doi.org\/10.1007\/s10237-018-1069-9.","journal-title":"Biomech. Model. Mechanobiol."},{"key":"4399_CR19","doi-asserted-by":"crossref","unstructured":"McGee, O., A. McNamara, L. McNamara. A Patient-Specific Model of Transcatheter Valve Replacement in a Bicuspid Heart Valve. 2021.","DOI":"10.1101\/2021.03.05.433633"},{"key":"4399_CR20","doi-asserted-by":"publisher","first-page":"9906","DOI":"10.1038\/s41598-020-66899-6","volume":"10","author":"GM Bosi","year":"2020","unstructured":"Bosi, G. M., C. Capelli, M. H. Cheang, N. Delahunty, M. Mullen, A. M. Taylor, and S. Schievano. A validated computational framework to predict outcomes in TAVI. Sci. Rep. 10:9906, 2020. https:\/\/doi.org\/10.1038\/s41598-020-66899-6.","journal-title":"Sci. Rep."},{"key":"4399_CR21","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1111\/aor.14189","volume":"46","author":"S Reza","year":"2022","unstructured":"Reza, S., M. Bianchi, B. Kovarovic, S. Anam, M. J. Slepian, A. Hamdan, R. Haj-Ali, and D. Bluestein. A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy. Artif. Organs. 46:1305\u20131317, 2022. https:\/\/doi.org\/10.1111\/aor.14189.","journal-title":"Artif. Organs"},{"key":"4399_CR22","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10237-024-01893-9","volume":"24","author":"S Reza","year":"2025","unstructured":"Reza, S., B. Kovarovic, and D. Bluestein. Assessing post-TAVR cardiac conduction abnormalities risk using an electromechanically coupled beating heart. Biomech. Model Mechanobiol. 24:29\u201345, 2025. https:\/\/doi.org\/10.1007\/s10237-024-01893-9.","journal-title":"Biomech. Model Mechanobiol."},{"key":"4399_CR23","doi-asserted-by":"publisher","first-page":"1989","DOI":"10.1007\/s10439-014-1051-3","volume":"42","author":"PS Gunning","year":"2014","unstructured":"Gunning, P. S., T. J. Vaughan, and L. M. McNamara. Simulation of self expanding transcatheter aortic valve in a realistic aortic root: implications of deployment geometry on leaflet deformation. Ann. Biomed. Eng. 42:1989\u20132001, 2014. https:\/\/doi.org\/10.1007\/s10439-014-1051-3.","journal-title":"Ann. Biomed. Eng."},{"key":"4399_CR24","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1080\/10255842.2020.1817409","volume":"24","author":"G Luraghi","year":"2021","unstructured":"Luraghi, G., J. F. R. Matas, M. Beretta, N. Chiozzi, L. Iannetti, and F. Migliavacca. The impact of calcification patterns in transcatheter aortic valve performance: a fluid-structure interaction analysis. Comput. Methods Biomech. Biomed. Eng. 24:375\u2013383, 2021. https:\/\/doi.org\/10.1080\/10255842.2020.1817409.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"4399_CR25","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1080\/10255842.2015.1058928","volume":"19","author":"J Bailey","year":"2016","unstructured":"Bailey, J., N. Curzen, and N. W. Bressloff. Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root. Comput. Methods Biomech. Biomed. Eng. 19:733\u2013744, 2016. https:\/\/doi.org\/10.1080\/10255842.2015.1058928.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"4399_CR26","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1007\/s13239-022-00620-8","volume":"13","author":"SB Anam","year":"2022","unstructured":"Anam, S. B., B. J. Kovarovic, R. P. Ghosh, M. Bianchi, A. Hamdan, R. Haj-Ali, and D. Bluestein. Validating in silico and in vitro patient-specific structural and flow models with transcatheter bicuspid aortic valve replacement procedure. Cardiovasc. Eng. Technol. 13:840\u2013856, 2022. https:\/\/doi.org\/10.1007\/s13239-022-00620-8.","journal-title":"Cardiovasc. Eng. Technol."},{"key":"4399_CR27","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s10237-018-1094-8","volume":"18","author":"M Bianchi","year":"2019","unstructured":"Bianchi, M., G. Marom, R. P. Ghosh, O. M. Rotman, P. Parikh, L. Gruberg, and D. Bluestein. Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage. Biomech. Model Mechanobiol. 18:435\u2013451, 2019. https:\/\/doi.org\/10.1007\/s10237-018-1094-8.","journal-title":"Biomech. Model Mechanobiol."},{"key":"4399_CR28","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","volume":"71","author":"GM Bosi","year":"2018","unstructured":"Bosi, G. M., C. Capelli, M. H. Cheang, N. Delahunty, M. Mullen, A. M. Taylor, and S. Schievano. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. J. Biomech. 71:236\u2013244, 2018. https:\/\/doi.org\/10.1016\/j.jbiomech.2018.02.017.","journal-title":"J. Biomech."},{"key":"4399_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ijcard.2014.04.003","volume":"174","author":"T Kawashima","year":"2014","unstructured":"Kawashima, T., and F. Sato. Visualizing anatomical evidences on atrioventricular conduction system for TAVI. Int. J. Cardiol. 174:1\u20136, 2014. https:\/\/doi.org\/10.1016\/j.ijcard.2014.04.003.","journal-title":"Int. J. Cardiol."},{"key":"4399_CR30","doi-asserted-by":"publisher","first-page":"3336","DOI":"10.1007\/s44174-025-00413-2","volume":"4","author":"K Baylous","year":"2026","unstructured":"Baylous, K., S. Anam, B. Kovarovic, P. B. Parikh, J. Price, M. Yammine, A. McLarty, M. Slepian, and D. Bluestein. In vitro biomechanical examination of excised calcified aortic leaflet tissue for material property assessment and improved in silico modeling. Biomed. Mater. Dev. 4:3336\u20133354, 2026. https:\/\/doi.org\/10.1007\/s44174-025-00413-2.","journal-title":"Biomed. Mater. Dev."},{"key":"4399_CR31","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.1002\/jbm.a.34099","volume":"100","author":"C Martin","year":"2012","unstructured":"Martin, C., and W. Sun. Biomechanical characterization of aortic valve tissue in humans and common animal models. J. Biomed. Mater. Res. A. 100:1591\u20131599, 2012. https:\/\/doi.org\/10.1002\/jbm.a.34099.","journal-title":"J. Biomed. Mater. Res. A"},{"key":"4399_CR32","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/j.actbio.2017.03.026","volume":"54","author":"T Pham","year":"2017","unstructured":"Pham, T., F. Sulejmani, E. Shin, D. Wang, and W. Sun. Quantification and comparison of the mechanical properties of four human cardiac valves. Acta Biomater. 54:345\u2013355, 2017. https:\/\/doi.org\/10.1016\/j.actbio.2017.03.026.","journal-title":"Acta Biomater."},{"key":"4399_CR33","doi-asserted-by":"publisher","first-page":"3389","DOI":"10.1007\/s10439-025-03869-x","volume":"53","author":"T Shirakawa","year":"2025","unstructured":"Shirakawa, T., K. Shimamura, K. Maeda, S. Yajima, A. Kawamura, T. Kawamura, D. Yoshioka, and S. Miyagawa. Ex vivo quantification of calcification stiffness in aortic stenosis: biomechanical data from resected human valves. Ann. Biomed. Eng. 53:3389\u20133399, 2025. https:\/\/doi.org\/10.1007\/s10439-025-03869-x.","journal-title":"Ann. Biomed. Eng."},{"key":"4399_CR34","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2023.107886","volume":"243","author":"K Baylous","year":"2024","unstructured":"Baylous, K., R. Helbock, B. Kovarovic, S. Anam, M. Slepian, and D. Bluestein. In silico fatigue optimization of TAVR stent designs with physiological motion in a beating heart model. Comput. Methods Progr. Biomed.243:107886, 2024. https:\/\/doi.org\/10.1016\/j.cmpb.2023.107886.","journal-title":"Comput. Methods Progr. Biomed."},{"key":"4399_CR35","doi-asserted-by":"publisher","first-page":"E292","DOI":"10.1111\/aor.12806","volume":"40","author":"M Bianchi","year":"2016","unstructured":"Bianchi, M., G. Marom, R. P. Ghosh, H. A. Fernandez, J. R. Taylor Jr., M. J. Slepian, and D. Bluestein. Effect of balloon-expandable transcatheter aortic valve replacement positioning: a patient-specific numerical model. Artif. Organs. 40:E292-e304, 2016. https:\/\/doi.org\/10.1111\/aor.12806.","journal-title":"Artif. Organs"},{"key":"4399_CR36","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1016\/j.jbiomech.2015.10.048","volume":"49","author":"S Morganti","year":"2016","unstructured":"Morganti, S., N. Brambilla, A. S. Petronio, A. Reali, F. Bedogni, and F. Auricchio. Prediction of patient-specific post-operative outcomes of TAVI procedure: the impact of the positioning strategy on valve performance. J. Biomech. 49:2513\u20132519, 2016. https:\/\/doi.org\/10.1016\/j.jbiomech.2015.10.048.","journal-title":"J. Biomech."},{"key":"4399_CR37","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.medengphy.2012.04.009","volume":"35","author":"S Tzamtzis","year":"2013","unstructured":"Tzamtzis, S., J. Viquerat, J. Yap, M. J. Mullen, and G. Burriesci. Numerical analysis of the radial force produced by the medtronic-corevalve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med. Eng. Phys. 35:125\u2013130, 2013. https:\/\/doi.org\/10.1016\/j.medengphy.2012.04.009.","journal-title":"Med. Eng. Phys."},{"key":"4399_CR38","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1016\/j.jbiomech.2012.05.008","volume":"45","author":"Q Wang","year":"2012","unstructured":"Wang, Q., E. Sirois, and W. Sun. Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment. J. Biomech. 45:1965\u20131971, 2012. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.05.008.","journal-title":"J. Biomech."},{"key":"4399_CR39","doi-asserted-by":"publisher","first-page":"155","DOI":"10.14740\/cr1011","volume":"11","author":"E Sharma","year":"2020","unstructured":"Sharma, E., B. McCauley, D. S. Ghosalkar, M. Atalay, S. Collins, A. Parulkar, W. Sheikh, M. B. Ahmed, and A. Chu. Aortic valve calcification as a predictor of post-transcatheter aortic valve replacement pacemaker dependence. Cardiol. Res. 11:155\u2013167, 2020. https:\/\/doi.org\/10.14740\/cr1011.","journal-title":"Cardiol. Res."},{"key":"4399_CR40","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.jjcc.2022.03.011","volume":"80","author":"T Nomura","year":"2022","unstructured":"Nomura, T., M. Miyasaka, M. Nakashima, M. Saigan, A. Inoue, Y. Enta, Y. Toki, K. Ishii, M. Sakurai, Y. Munehisa, et al. Delivery balloon volume positively correlates with the diameter and effective orifice area of implanted SAPIEN 3. J. Cardiol. 80:190\u2013196, 2022. https:\/\/doi.org\/10.1016\/j.jjcc.2022.03.011.","journal-title":"J. Cardiol."},{"key":"4399_CR41","doi-asserted-by":"publisher","first-page":"467","DOI":"10.5603\/CJ.a2017.0014","volume":"24","author":"P Chod\u00f3r","year":"2017","unstructured":"Chod\u00f3r, P., K. Wilczek, R. Przybylski, J. G\u0142owacki, T. Kukulski, W. Streb, T. Niklewski, G. Honisz, P. Trzeciak, T. Podolecki, et al. Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation. Cardiol. J. 24:467\u2013476, 2017. https:\/\/doi.org\/10.5603\/CJ.a2017.0014.","journal-title":"Cardiol. J."},{"key":"4399_CR42","doi-asserted-by":"publisher","DOI":"10.1161\/circinterventions.119.008714","volume":"13","author":"A Mangieri","year":"2020","unstructured":"Mangieri, A., D. Tchetch\u00e8, W. K. Kim, M. Pagnesi, J. M. Sinning, U. Landes, R. Kornowski, O. De Backer, G. Nickenig, A. Ielasi, et al. Balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis: insights from the BEAT international collaborative registrys. Circ. Cardiovasc. Interv.13:e008714, 2020. https:\/\/doi.org\/10.1161\/circinterventions.119.008714.","journal-title":"Circ. Cardiovasc. Interv."},{"key":"4399_CR43","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12227074","author":"L Gutierrez","year":"2023","unstructured":"Gutierrez, L., M. Boiago, C. De Biase, O. Oliva, P. Laforgia, S. Feliachi, A. Beneduce, N. Dumonteil, and D. Tchetche. Transcatheter aortic valve implantation for bicuspid aortic valve disease: procedural planning and clinical outcomes. J. Clin. Med. 2023. https:\/\/doi.org\/10.3390\/jcm12227074.","journal-title":"J. Clin. Med."},{"key":"4399_CR44","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.jacasi.2021.07.012","volume":"1","author":"M Chen","year":"2021","unstructured":"Chen, M., J. Michel, and A. M. Kasel. Application of balloon-expandable transcatheter heart valve in bicuspid aortic valve. JACC: Asia. 1:147\u2013161, 2021. https:\/\/doi.org\/10.1016\/j.jacasi.2021.07.012.","journal-title":"JACC: Asia"},{"key":"4399_CR45","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1080\/10255842.2015.1058928","volume":"19","author":"J Bailey","year":"2016","unstructured":"Bailey, J., N. Curzen, and N. W. Bressloff. Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root. Comput. Methods Biomech. Biomed. Eng. 19:733\u2013744, 2016. https:\/\/doi.org\/10.1080\/10255842.2015.1058928.","journal-title":"Comput. Methods Biomech. Biomed. Eng."}],"container-title":["Annals of Biomedical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04399-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-026-04399-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10439-026-04399-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:53:49Z","timestamp":1792029229000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10439-026-04399-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,14]]},"references-count":45,"alternative-id":["4399"],"URL":"https:\/\/doi.org\/10.1007\/s10439-026-04399-w","relation":{},"ISSN":["0090-6964","1573-9686"],"issn-type":[{"value":"0090-6964","type":"print"},{"value":"1573-9686","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,14]]},"assertion":[{"value":"11 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Author DB has an equity interest in PolyNova Cardiovascular Inc.","order":1,"name":"Ethics","label":"Competing Interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}