{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T12:11:00Z","timestamp":1789819860195,"version":"4.0.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomed Microdevices"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s10544-026-00837-7","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T14:26:41Z","timestamp":1785767201000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A high-precision bendable ophthalmic microinjection needle fabricated by polypropylene-fiber-templated electroplating: process design and ex vivo validation"],"prefix":"10.1007","volume":"28","author":[{"given":"Qiangsheng","family":"Fu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianshan","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongyan","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Di","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"837_CR1","first-page":"286","volume":"64","author":"A Aksit","year":"2021","unstructured":"A. Aksit, A.K. Lalwani, J.W. Kysar et al., Simulation assisted design for microneedle manufacturing: computational modeling of two-photon templated electrodeposition. J. Manuf. Process. 64, 286\u2013294 (2021)","journal-title":"J. Manuf. Process."},{"issue":"2","key":"837_CR2","first-page":"108","volume":"49","author":"WQ Bai","year":"2012","unstructured":"W.Q. Bai, Y.G. Li, X. Chen, Fabrication of metal microneedle array based on LIGA technology. Micro-nano Electron. Technol. 49(2), 108\u2013112 (2012)","journal-title":"Micro-nano Electron. Technol."},{"issue":"2","key":"837_CR3","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1111\/aos.14184","volume":"98","author":"S Bolme","year":"2020","unstructured":"S. Bolme, T.S. Morken, T. Follestad et al., Task shifting of intraocular injections from physicians to nurses: a randomized single-masked noninferiority study. Acta Ophthalmol. 98(2), 139\u2013144 (2020)","journal-title":"Acta Ophthalmol."},{"key":"837_CR4","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.3762\/bjnano.12.77","volume":"12","author":"Z Faraji Rad","year":"2021","unstructured":"Z. Faraji Rad, P.D. Prewett, G.J. Davies, An overview of microneedle applications, materials, and fabrication methods. Beilstein J. Nanotechnol. 12, 1034\u20131048 (2021)","journal-title":"Beilstein J. Nanotechnol."},{"issue":"4","key":"837_CR5","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1517\/17425241003628171","volume":"7","author":"SD Gittard","year":"2010","unstructured":"S.D. Gittard, A. Ovsianikov, B.N. Chichkov et al., Two photon polymerization of microneedles for transdermal drug delivery. Expert Opin. Drug Deliv. 7(4), 513\u2013526 (2010)","journal-title":"Expert Opin. Drug Deliv."},{"key":"837_CR6","first-page":"231","volume":"14","author":"K Kim","year":"2008","unstructured":"K. Kim, J.B. Lee, High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector. Microsyst. Technol. 14, 231\u2013235 (2008)","journal-title":"Microsyst. Technol."},{"key":"837_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2025.1689049","author":"GY Lan","year":"2025","unstructured":"G.Y. Lan, Z.X. Li, W.H. Cheng et al., Medical-nursing integrated service model in ophthalmic outpatient care for intravitreal injections: a retrospective cohort study. Front. Med. (2025). https:\/\/doi.org\/10.3389\/fmed.2025.1689049","journal-title":"Front. Med."},{"key":"837_CR8","first-page":"755","volume":"8","author":"MM Michelotti","year":"2014","unstructured":"M.M. Michelotti, S. Abugreen, S.P. Kelly et al., Transformational change: nurses substituting for ophthalmologists for intravitreal injections: a quality-improvement report. Clin. Ophthalmol. 8, 755\u2013761 (2014)","journal-title":"Clin. Ophthalmol."},{"key":"837_CR9","doi-asserted-by":"publisher","first-page":"2123","DOI":"10.1038\/s41433-020-0920-2","volume":"34","author":"SY Sim","year":"2020","unstructured":"S.Y. Sim, C.C. Yip, J. Chiew et al., Design, implementation, and evaluation of a nurse-led intravitreal injection programme for retinal diseases in Singapore. Eye. 34, 2123\u20132130 (2020)","journal-title":"Eye"},{"key":"837_CR10","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1038\/eye.2014.153","volume":"28","author":"DA Sim","year":"2014","unstructured":"D.A. Sim, S. Goverdhan, C. Bunce et al., A safety audit of the first 10,000 intravitreal ranibizumab injections performed by nurse practitioners. Eye. 28, 1161\u20131164 (2014)","journal-title":"Eye"},{"key":"837_CR11","unstructured":"F. Wan, D. Cui, A microtube and manufacturing method of microinjection needle. Chin. Patent CN202311657935.2. 2024-01-05"},{"issue":"7","key":"837_CR12","first-page":"649","volume":"44","author":"BJ Xu","year":"2007","unstructured":"B.J. Xu, Q.H. Jin, J.L. Zhao, Research status and prospect of MEMS-based microneedle technology. Micro-nano Electron. Technol. 44(7), 649\u2013653 (2007)","journal-title":"Micro-nano Electron. Technol."},{"key":"837_CR13","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0104145","author":"YS You","year":"2014","unstructured":"Y.S. You, C.Y. Lee, C. Li et al., An arched micro-injector (ARCMI) for innocuous subretinal injection. PLoS ONE (2014). https:\/\/doi.org\/10.1371\/journal.pone.0104145","journal-title":"PLoS ONE"},{"issue":"4","key":"837_CR14","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1167\/tvst.13.4.28","volume":"13","author":"R Zhang","year":"2024","unstructured":"R. Zhang, L. Dong, X. Fu et al., Trends in the prevalence of common retinal and optic nerve diseases in China: an artificial intelligence-based national screening. Translational Vis. Sci. Technol. 13(4), 28 (2024)","journal-title":"Translational Vis. Sci. Technol."},{"key":"837_CR15","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/19\/11\/115010","author":"MW Zhu","year":"2009","unstructured":"M.W. Zhu, H.W. Li, X.L. Chen et al., Silica needle template fabrication of metal hollow microneedle arrays. J. Micromech. Microeng. (2009). https:\/\/doi.org\/10.1088\/0960-1317\/19\/11\/115010","journal-title":"J. Micromech. Microeng."}],"container-title":["Biomedical Microdevices"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10544-026-00837-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10544-026-00837-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10544-026-00837-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T11:37:52Z","timestamp":1789817872000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10544-026-00837-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["837"],"URL":"https:\/\/doi.org\/10.1007\/s10544-026-00837-7","relation":{},"ISSN":["1387-2176","1572-8781"],"issn-type":[{"value":"1387-2176","type":"print"},{"value":"1572-8781","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"assertion":[{"value":"1 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The ex vivo porcine eyes used in this study were obtained from a local slaughterhouse. No human participants, human data, human tissue, or live animals were involved.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"54"}}