{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T20:34:24Z","timestamp":1760646864263},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,7,5]],"date-time":"2018-07-05T00:00:00Z","timestamp":1530748800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Breast Cancer Res Treat"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1007\/s10549-018-4878-8","type":"journal-article","created":{"date-parts":[[2018,7,5]],"date-time":"2018-07-05T16:22:52Z","timestamp":1530807772000},"page":"693-699","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Dosimetric study to assess the feasibility of intraoperative radiotherapy with electrons (ELIOT) as partial breast irradiation for patients with cardiac implantable electronic device (CIED)"],"prefix":"10.1007","volume":"171","author":[{"given":"Rosa","family":"Luraschi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberta","family":"Lazzari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Viviana","family":"Galimberti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Rondi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessia","family":"Bazani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Corso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicola","family":"Colombo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rosalinda","family":"Ricotti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristiana","family":"Fodor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikolaj","family":"Winnicki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Cristina","family":"Leonardi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Barbara Alicja","family":"Jereczek-Fossa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Federica","family":"Cattani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,7,5]]},"reference":[{"issue":"Suppl 3","key":"4878_CR1","doi-asserted-by":"publisher","first-page":"iii1","DOI":"10.1093\/europace\/euw244","volume":"18","author":"MJ Raatikainen","year":"2016","unstructured":"Raatikainen MJ, Arnar DO, Merkely B, Camm AJ, Hindricks G (2016) Access to and clinical use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology Countries: 2016 Report from the European Heart Rhythm Association. Europace 18(Suppl 3):iii1\u2013iii79","journal-title":"Europace"},{"issue":"4","key":"4878_CR2","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1001\/jamaoncol.2016.5688","volume":"3","author":"C Fitzmaurice","year":"2017","unstructured":"Fitzmaurice C, Allen C, Barber RM et al (2017) Global, regional, and national cancer incidence, mortality, years of life lost, years lived with disability, and disability-adjusted life-years for 32 cancer groups, 1990 to 2015: a systematic analysis for the Global Burden of Disease Study. JAMA Oncol 3(4):524\u2013548","journal-title":"JAMA Oncol"},{"key":"4878_CR3","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1111\/pace.12572","volume":"38","author":"T Zaremba","year":"2015","unstructured":"Zaremba T, Jakobsen AR, S\u00f8gaard M et al (2015) Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study. Pacing Clin Electrophysiol 38:343\u2013356","journal-title":"Pacing Clin Electrophysiol"},{"key":"4878_CR4","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1186\/1748-717X-7-198","volume":"7","author":"CW Hurkmans","year":"2012","unstructured":"Hurkmans CW, Knegjens JL, Oei BS, Maas AJJ et al (2012) Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline. Neth Radiat Oncol 7:198","journal-title":"Neth Radiat Oncol"},{"key":"4878_CR5","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1016\/j.ctrv.2005.05.002","volume":"31","author":"S Sundar","year":"2005","unstructured":"Sundar S, Symonds RP, Deehan C (2005) Radiotherapy to patients with artificial cardiac pacemakers. Cancer Treat Rev 31:474\u2013486","journal-title":"Cancer Treat Rev"},{"issue":"8","key":"4878_CR6","doi-asserted-by":"publisher","first-page":"2212","DOI":"10.1200\/JCO.2002.20.8.2212","volume":"20","author":"S Hoecht","year":"2002","unstructured":"Hoecht S, Rosenthal P, Sancar D, Behrens S, Hinkelbein W, Hoeller U (2002) Implantable cardiac defibrillators may be damaged by radiation therapy. J Clin Oncol 20(8):2212\u20132213","journal-title":"J Clin Oncol"},{"key":"4878_CR7","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1093\/europace\/euv135","volume":"18","author":"T Zaremba","year":"2016","unstructured":"Zaremba T, Jakobsen AR, S\u00f8gaard M, Th\u00f8gersen AM, Riahi S (2016) Radiotherapy in patients with pacemakers and implantable cardioverter defibrillators: a literature review. Europace 18:479\u2013491","journal-title":"Europace"},{"key":"4878_CR8","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.ijcard.2017.12.061","volume":"255","author":"M Zecchin","year":"2018","unstructured":"Zecchin M, Severgnini M, Fiorentino A, Malavasi VL, Menegotti L, Alongi F, Catanzariti D, Jereczek-Fossa BA, Stasi M, Russi E, Boriani G (2018) Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: a consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM). Int J Cardiol 255:175\u2013183","journal-title":"Int J Cardiol"},{"issue":"1","key":"4878_CR9","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1118\/1.597259","volume":"21","author":"JR Marbach","year":"1994","unstructured":"Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB (1994) Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM Task Group No. 34. Med Phys 21(1):85\u201390","journal-title":"Med Phys"},{"key":"4878_CR10","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1016\/j.ijrobp.2004.02.038","volume":"59","author":"AN Solan","year":"2004","unstructured":"Solan AN, Solan MJ, Bednarz G, Goodkin MB (2004) Treatment of patients with cardiac pacemakers and implantable cardioverter defibrillators during radiotherapy. Int J Radiat Oncol Biol Phys 59:897\u2013904","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"4878_CR11","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1111\/j.1754-9485.2010.02138.x","volume":"54","author":"F Hudson","year":"2010","unstructured":"Hudson F, Couldshed D, D\u2019Souza E, Baker C (2010) Effect of radiation therapy on the latest generation of pacemaker and implantable cardioverter defibrillators: a systematic review. J Med Imaging Radiat Oncol 54:53\u201361","journal-title":"J Med Imaging Radiat Oncol"},{"key":"4878_CR12","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1111\/j.1540-8159.2004.00513.x","volume":"27","author":"J John","year":"2004","unstructured":"John J, Kaye GC (2004) Shock coil failure secondary to external irradiation in a patient with implantable cardioverter defibrillator. Pacing Clin Electrophysiol 27:690\u2013691","journal-title":"Pacing Clin Electrophysiol"},{"issue":"5","key":"4878_CR13","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1001\/jamaoncol.2015.1787","volume":"1","author":"JD Grant","year":"2015","unstructured":"Grant JD, Jensen GL, Tang C, Pollard JM, Kry SF, Krishnan S, Dougherty AH, Gomez DR, Rozner MA (2015) Radiotherapy-induced malfunction in contemporary cardiovascular implantable electronic devices: clinical incidence and predictors. JAMA Oncol 1(5):624\u2013632","journal-title":"JAMA Oncol"},{"issue":"5","key":"4878_CR14","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1007\/s00066-015-0817-3","volume":"191","author":"B Gauter-Fleckenstein","year":"2015","unstructured":"Gauter-Fleckenstein B, Israel CW, Dorenkamp M et al (2015) DEGRO\/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlenther Onkol 191(5):393\u2013404","journal-title":"Strahlenther Onkol"},{"key":"4878_CR15","doi-asserted-by":"publisher","first-page":"2879","DOI":"10.1088\/0031-9155\/47\/16\/304","volume":"47","author":"J Mouton","year":"2002","unstructured":"Mouton J, Haug R, Bridier A, Dodinot B, Eschwege F (2002) Influence of high-energy photon beam irradiation on pacemaker operation. Phys Med Biol 47:2879\u20132893","journal-title":"Phys Med Biol"},{"issue":"1","key":"4878_CR16","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.ijrobp.2005.04.047","volume":"63","author":"CW Hurkmans","year":"2005","unstructured":"Hurkmans CW, Scheepers E, Springorum B, Uiterwaal H (2005) Influence of radiotherapy on the latest generation on implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys 63(1):282\u2013289","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"4878_CR17","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1111\/j.1540-8159.1994.tb01387.x","volume":"17","author":"SK Souliman","year":"1994","unstructured":"Souliman SK, Christie J (1994) Pacemaker failure induced by radiotherapy. PACE 17:270\u2013273","journal-title":"PACE"},{"issue":"2","key":"4878_CR18","doi-asserted-by":"publisher","first-page":"193","DOI":"10.4103\/0973-1482.113348","volume":"9","author":"A Munshi","year":"2013","unstructured":"Munshi A, Agarwal JP, Pandey KC (2013) Cancer patients with cardiac pacemakers needing radiation treatment: a systematic review. J Cancer Res Ther 9(2):193\u2013198","journal-title":"J Cancer Res Ther"},{"issue":"2","key":"4878_CR19","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.meddos.2004.03.013","volume":"29","author":"B Riley","year":"2004","unstructured":"Riley B, Garcia J, Gurrero T (2004) The utilization of a 3-dimensional non coplanar treatment plan to avoid pacemaker complications. Med Dosim 29(2):92\u201396","journal-title":"Med Dosim"},{"key":"4878_CR20","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1046\/j.1524-4741.2003.09208.x","volume":"9","author":"U Veronesi","year":"2003","unstructured":"Veronesi U, Gatti G, Luini A et al (2003) Intraoperative radiation therapy for breast cancer: technical notes. Breast J 9:106\u2013112","journal-title":"Breast J"},{"issue":"1","key":"4878_CR21","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1245\/s10434-008-0172-z","volume":"16","author":"V Galimberti","year":"2009","unstructured":"Galimberti V, Ciocca M, Leonardi MC et al (2009) Is electron beam intraoperative radiotherapy (ELIOT) safe in pregnant women with early breast cancer? In vivo dosimetry to assess fetal dose. Ann Surg Oncol 16(1):100\u2013105","journal-title":"Ann Surg Oncol"},{"issue":"6","key":"4878_CR22","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1159\/000479862","volume":"12","author":"MC Leonardi","year":"2017","unstructured":"Leonardi MC, Cecconi A, Luraschi R et al (2017) Electron beam intraoperative radiotherapy (ELIOT) in pregnant women with breast cancer: from in vivo dosimetry to clinical practice. Breast Care 12(6):396\u2013400","journal-title":"Breast Care"},{"key":"4878_CR23","first-page":"73","volume":"35","author":"G Riva","year":"2018","unstructured":"Riva G, Alessandro O, Spoto R et al (2018) Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects. Int J Radiat Oncol Biol Phys 35:73","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"4878_CR24","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.breast.2016.07.010","volume":"29","author":"MC Leonardi","year":"2016","unstructured":"Leonardi MC, Ricotti R, Dicuonzo S et al (2016) From technological advances to biological understanding: the main steps toward high-precision RT in breast cancer. Breast 29:213\u2013222","journal-title":"Breast"},{"issue":"10","key":"4878_CR25","doi-asserted-by":"publisher","first-page":"1698","DOI":"10.1001\/jamainternmed.2015.4128","volume":"175","author":"ZH Tseng","year":"2015","unstructured":"Tseng ZH (2015) Risk of cardiovascular implantable electronic device malfunction with radiation therapy: location, dose, or energy? JAMA Intern Med 175(10):1698\u20131699","journal-title":"JAMA Intern Med"},{"issue":"12","key":"4878_CR26","doi-asserted-by":"publisher","first-page":"3500","DOI":"10.1245\/s10434-011-1784-2","volume":"18","author":"R Croshaw","year":"2011","unstructured":"Croshaw R, Kim Y, Lappinen E, Julian T, Trombetta M (2011) Avoiding mastectomy: accelerated partial breast irradiation for breast cancer patients with pacemakers or defibrillators. Ann Surg Oncol 18(12):3500\u20133505","journal-title":"Ann Surg Oncol"},{"issue":"5","key":"4878_CR27","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.brachy.2012.01.001","volume":"11","author":"Y Kim","year":"2012","unstructured":"Kim Y, Arshoun Y, Trombetta MG (2012) Pacemaker\/implantable cardioverter-defibrillator dose in balloon high-dose-rate brachytherapy for breast cancer treatment. Brachytherapy 11(5):380\u2013386","journal-title":"Brachytherapy"},{"key":"4878_CR28","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1186\/1748-717X-7-128","volume":"7","author":"MR Keshtgar","year":"2012","unstructured":"Keshtgar MR, Eaton DJ, Reynolds C, Pigott K, Davidson T, Gauter-Fleckenstein B, Wenz F (2012) Pacemaker and radiotherapy in breast cancer: is targeted intraoperative radiotherapy the answer in this setting? Radiat Oncol 7:128","journal-title":"Radiat Oncol"},{"key":"4878_CR29","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/j.apradiso.2009.09.039","volume":"68","author":"AM Costa","year":"2010","unstructured":"Costa AM, Barbi GL, Bertucci EC et al (2010) In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy. Appl Radiat Isot 68:760\u2013762","journal-title":"Appl Radiat Isot"},{"key":"4878_CR30","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1093\/oxfordjournals.rpd.a032882","volume":"85","author":"L D\u2019Angelo","year":"1999","unstructured":"D\u2019Angelo L, Furetta C, Giaucola S, Iannoli D, Scacco AG (1999) Verification of treatment planning systems for therapeutic irradiations using thermoluminescence dosimeters. Radiat Prot Dosim 85:401\u2013404","journal-title":"Radiat Prot Dosim"},{"issue":"10","key":"4878_CR31","doi-asserted-by":"publisher","first-page":"6185","DOI":"10.1118\/1.4752088","volume":"39","author":"W Sung","year":"2012","unstructured":"Sung W, Kim S, Kim JI, Lee JG, Shin YJ, Jung JY, Ye SJ (2012) Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite(\u00ae) treatment. Med Phys 39(10):6185\u20136191","journal-title":"Med Phys"},{"issue":"12","key":"4878_CR32","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1016\/j.hrthm.2012.08.018","volume":"9","author":"A Makkar","year":"2012","unstructured":"Makkar A, Prisciandaro J, Agarwal S et al (2012) Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function. Heart Rhythm 9(12):1964\u20131968","journal-title":"Heart Rhythm"},{"key":"4878_CR33","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/S0969-8043(01)00084-7","volume":"55","author":"JP Lin","year":"2001","unstructured":"Lin JP, Chu TC, Lin SY, Liu MT (2001) The measurement of photoneutrons in the vicinity of a Siemens Primus linear accelerator. Appl Radiat Isot 55:315\u2013321","journal-title":"Appl Radiat Isot"},{"key":"4878_CR34","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1118\/1.597145","volume":"20","author":"R Nath","year":"1993","unstructured":"Nath R, Meigooni AS, King CR, Smolen S, D\u2019Errico F (1993) Superheated drop detector for determination of neutron dose equivalent to patients undergoing high-energy X-ray and electron radiotherapy. Med Phys 20:781\u2013787","journal-title":"Med Phys"},{"issue":"2","key":"4878_CR35","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1080\/02841860701678779","volume":"47","author":"A Munshi","year":"2008","unstructured":"Munshi A, Wadasadawala T, Sharma PK, Sharma D, Budrukkar A, Jalali R, Dinshaw KA (2008) Radiation therapy planning of a breast cancer patient with in situ pacemaker-challenges and lessons. Acta Oncol 47(2):255\u2013260","journal-title":"Acta Oncol"},{"issue":"3","key":"4878_CR36","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.radonc.2010.01.014","volume":"94","author":"C Polg\u00e1r","year":"2010","unstructured":"Polg\u00e1r C, Van Limbergen E, P\u00f6tter R et al (2010) Patient selection for accelerated partial-breast irradiation (APBI) after breast-conserving surgery: recommendations of the Groupe Europ\u00e9en de Curieth\u00e9rapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) breast cancer working group based on clinical evidence (2009). Radiother Oncol 94(3):264\u2013273","journal-title":"Radiother Oncol"},{"issue":"2","key":"4878_CR37","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.prro.2016.09.007","volume":"7","author":"C Correa","year":"2017","unstructured":"Correa C, Harris EE, Leonardi MC et al (2017) Accelerated partial breast irradiation: executive summary for the update of an ASTRO evidence-based consensus statement. Pract Radiat Oncol 7(2):73\u201379","journal-title":"Pract Radiat Oncol"}],"container-title":["Breast Cancer Research and Treatment"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10549-018-4878-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10549-018-4878-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10549-018-4878-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,4]],"date-time":"2019-07-04T23:22:23Z","timestamp":1562282543000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10549-018-4878-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,5]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["4878"],"URL":"https:\/\/doi.org\/10.1007\/s10549-018-4878-8","relation":{},"ISSN":["0167-6806","1573-7217"],"issn-type":[{"value":"0167-6806","type":"print"},{"value":"1573-7217","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,5]]},"assertion":[{"value":"25 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All the authors declare that there is no actual or potential conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The dosimetric study has been approved by the institutional Ethical Committee with the number IEO0090. This article does not contain any studies with animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}