{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T15:03:32Z","timestamp":1761059012923},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"S1","license":[{"start":{"date-parts":[[2010,1,8]],"date-time":"2010-01-08T00:00:00Z","timestamp":1262908800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2010,2]]},"DOI":"10.1007\/s10554-009-9576-5","type":"journal-article","created":{"date-parts":[[2010,1,7]],"date-time":"2010-01-07T07:00:59Z","timestamp":1262847659000},"page":"17-25","source":"Crossref","is-referenced-by-count":36,"title":["Coronary CT angiography with low radiation dose"],"prefix":"10.1007","volume":"26","author":[{"given":"Lei","family":"Xu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhaoqi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,1,8]]},"reference":[{"issue":"10","key":"9576_CR1","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1161\/CIRCULATIONAHA.105.602490","volume":"113","author":"J Hausleiter","year":"2006","unstructured":"Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multi-slice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113(10):1305\u20131310","journal-title":"Circulation"},{"issue":"2","key":"9576_CR2","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1148\/radiol.2442061218","volume":"244","author":"PK Vanhoenacker","year":"2007","unstructured":"Vanhoenacker PK, Heijenbrok-Kal MH, Van Heste R et al (2007) Diagnostic performance of multi-detector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology 244(2):419\u2013428","journal-title":"Radiology"},{"issue":"1","key":"9576_CR3","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.jacc.2005.03.071","volume":"46","author":"AW Leber","year":"2005","unstructured":"Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and non-obstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46(1):147\u2013154","journal-title":"J Am Coll Cardiol"},{"issue":"12","key":"9576_CR4","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1007\/s00330-006-0474-0","volume":"16","author":"H Scheffel","year":"2006","unstructured":"Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16(12):2739\u20132747","journal-title":"Eur Radiol"},{"issue":"1","key":"9576_CR5","doi-asserted-by":"crossref","first-page":"188","DOI":"10.2214\/AJR.06.1201","volume":"189","author":"G Hur","year":"2007","unstructured":"Hur G, Hong SW, Kim SY et al (2007) Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography. AJR Am J Roentgenol 189(1):188\u2013196","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"9576_CR6","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1136\/heart.85.2.127","volume":"85","author":"P Wilde","year":"2001","unstructured":"Wilde P, Pitcher EM, Slack K (2001) Radiation hazards for the patient in cardiological procedures. Heart 85(2):127\u2013130","journal-title":"Heart"},{"issue":"10","key":"9576_CR7","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1007\/s00330-003-1831-x","volume":"13","author":"V Neofotistou","year":"2003","unstructured":"Neofotistou V, Vano E, Padovani R et al (2003) Preliminary reference levels in interventional cardiology. Eur Radiol 13(10):2259\u20132263","journal-title":"Eur Radiol"},{"issue":"9","key":"9576_CR8","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1016\/j.jacc.2005.11.078","volume":"47","author":"DR Coles","year":"2006","unstructured":"Coles DR, Smail MA, Negus IS et al (2006) Comparison of radiation doses from multi-slice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47(9):1840\u20131845","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"9576_CR9","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.2214\/AJR.08.1025","volume":"192","author":"T Pflederer","year":"2009","unstructured":"Pflederer T, Rudofsky L, Ropers D et al (2009) Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography. AJR Am J Roentgenol 192(4):1045\u20131050","journal-title":"AJR Am J Roentgenol"},{"key":"9576_CR10","volume-title":"Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2","author":"Committee to assess health risks from exposure to low levels of ionizing radiation","year":"2006","unstructured":"Committee to assess health risks from exposure to low levels of ionizing radiation, National Research Council (2006) Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2. National Academies, Washington"},{"issue":"22","key":"9576_CR11","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner DJ, Hall EJ (2007) Computed tomography\u2014an increasing source of radiation exposure. N Engl J Med 357(22):2277\u20132284","journal-title":"N Engl J Med"},{"issue":"2","key":"9576_CR12","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1148\/radiol.2312030767","volume":"231","author":"CI Lee","year":"2004","unstructured":"Lee CI, Haims AH, Monico EP et al (2004) Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology 231(2):393\u2013398","journal-title":"Radiology"},{"issue":"5","key":"9576_CR13","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1001\/jama.2009.54","volume":"301","author":"J Hausleiter","year":"2009","unstructured":"Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500\u2013507","journal-title":"JAMA"},{"issue":"3","key":"9576_CR14","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.ejrad.2008.08.015","volume":"68","author":"H Alkadhi","year":"2008","unstructured":"Alkadhi H, Stolzmann P, Scheffel H et al (2008) Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters. Eur J Radiol 68(3):385\u2013391","journal-title":"Eur J Radiol"},{"issue":"3","key":"9576_CR15","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1001\/jama.298.3.317","volume":"298","author":"AJ Einstein","year":"2007","unstructured":"Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298(3):317\u2013323","journal-title":"JAMA"},{"issue":"3","key":"9576_CR16","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1148\/radiol.2303021726","volume":"230","author":"MK Kalra","year":"2004","unstructured":"Kalra MK, Maher MM, Toth TL et al (2004) Strategies for CT radiation dose optimization. Radiology 230(3):619\u2013628","journal-title":"Radiology"},{"issue":"17","key":"9576_CR17","doi-asserted-by":"crossref","first-page":"1989","DOI":"10.1001\/jama.295.17.1989","volume":"295","author":"M Mitka","year":"2006","unstructured":"Mitka M (2006) CT angiography: clearer picture, Fuzzier reception. JAMA 295(17):1989\u20131990","journal-title":"JAMA"},{"issue":"2","key":"9576_CR18","doi-asserted-by":"crossref","first-page":"335","DOI":"10.2214\/AJR.07.2556","volume":"190","author":"T Kubo","year":"2008","unstructured":"Kubo T, Lin PJ, Stiller W et al (2008) Radiation dose reduction in chest CT: a review. AJR Am J Roentgenol 190(2):335\u2013343","journal-title":"AJR Am J Roentgenol"},{"issue":"956","key":"9576_CR19","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1259\/bjr\/97260522","volume":"80","author":"K Fujii","year":"2007","unstructured":"Fujii K, Aoyama T, Koyama S et al (2007) Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations. Br J Radiol 80(956):657\u2013667","journal-title":"Br J Radiol"},{"issue":"11","key":"9576_CR20","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1161\/CIRCULATIONAHA.107.688101","volume":"116","author":"AJ Einstein","year":"2007","unstructured":"Einstein AJ, Moser KW, Thompson RC et al (2007) Radiation dose to patients from cardiac diagnostic imaging. Circulation 116(11):1290\u20131305","journal-title":"Circulation"},{"key":"9576_CR21","unstructured":"Menzel H, Schibilla H, Teunen D (2000) European guidelines on quality criteria for computed tomography. Publication no. EUR16262 EN. European Commission, Luxembourg. Available at: http:\/\/www.drs.dk\/guidelines\/ct\/quality\/index.htm"},{"issue":"6 Suppl 2","key":"9576_CR22","doi-asserted-by":"crossref","first-page":"S387","DOI":"10.2214\/AJR.05.0216","volume":"186","author":"HT Abada","year":"2006","unstructured":"Abada HT, Larchez C, Daoud B et al (2006) MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR Am J Roentgenol 186(6 Suppl 2):S387\u2013S390","journal-title":"AJR Am J Roentgenol"},{"issue":"12","key":"9576_CR23","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1055\/s-2002-35945","volume":"174","author":"LW Poll","year":"2002","unstructured":"Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (\u201cECG pulsing\u201d): phantom measurements. Rofo 174(12):1500\u20131505","journal-title":"Rofo"},{"issue":"3","key":"9576_CR24","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1148\/radiol.2333031150","volume":"233","author":"MK Kalra","year":"2004","unstructured":"Kalra MK, Maher MM, Toth TL et al (2004) Techniques and applications of automatic tube current modulation for CT. Radiology 233(3):649\u2013657","journal-title":"Radiology"},{"issue":"5","key":"9576_CR25","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.2214\/AJR.07.3124","volume":"190","author":"C Herzog","year":"2008","unstructured":"Herzog C, Mulvihill DM, Nguyen SA et al (2008) Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. AJR Am J Roentgenol 190(5):1232\u20131240","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"9576_CR26","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1097\/RCT.0b013e31815ea873","volume":"32","author":"M Francone","year":"2008","unstructured":"Francone M, Di Castro E, Napoli A et al (2008) Dose reduction and image quality assessment in 64-detector row computed tomography of the coronary arteries using an automatic exposure control system. J Comput Assist Tomogr 32(5):668\u2013678","journal-title":"J Comput Assist Tomogr"},{"issue":"4","key":"9576_CR27","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/RCT.0b013e31818af37c","volume":"33","author":"JK Hoang","year":"2009","unstructured":"Hoang JK, Hurwitz LM, Boll DT et al (2009) Optimization of tube current in coronary multi-detector computed tomography angiography: assessment of a standardized method to individualize current selection based on body habitus. J Comput Assist Tomogr 33(4):498\u2013504","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"9576_CR28","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1148\/radiol.2311030191","volume":"231","author":"AB Sigal-Cinqualbre","year":"2004","unstructured":"Sigal-Cinqualbre AB, Hennequin R, Abada HT et al (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231(1):169\u2013174","journal-title":"Radiology"},{"issue":"2","key":"9576_CR29","doi-asserted-by":"crossref","first-page":"461","DOI":"10.2214\/ajr.179.2.1790461","volume":"179","author":"SR Prasad","year":"2002","unstructured":"Prasad SR, Wittram C, Shepard JA et al (2002) Standard-dose and 50%-reduced-dose chest CT: comparing the effect on image quality. AJR Am J Roentgenol 179(2):461\u2013465","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"9576_CR30","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1148\/radiology.217.2.r00nv35430","volume":"217","author":"W Huda","year":"2000","unstructured":"Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217(2):430\u2013435","journal-title":"Radiology"},{"issue":"12","key":"9576_CR31","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1097\/RLI.0b013e3181875e86","volume":"43","author":"Z Szucs-Farkas","year":"2008","unstructured":"Szucs-Farkas Z, Kurmann L, Strautz T et al (2008) Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols. Invest Radiol 43(12):871\u2013876","journal-title":"Invest Radiol"},{"issue":"2","key":"9576_CR32","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1093\/eurheartj\/ehm614","volume":"29","author":"P Schoenhagen","year":"2008","unstructured":"Schoenhagen P (2008) Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J 29(2):153\u2013154","journal-title":"Eur Heart J"},{"issue":"4","key":"9576_CR33","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1007\/s00330-008-1222-4","volume":"19","author":"O Klass","year":"2009","unstructured":"Klass O, Jeltsch M, Feuerlein S et al (2009) Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol 19(4):829\u2013836","journal-title":"Eur Radiol"},{"issue":"2","key":"9576_CR34","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1093\/eurheartj\/ehm613","volume":"29","author":"L Husmann","year":"2008","unstructured":"Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29(2):191\u2013197","journal-title":"Eur Heart J"},{"issue":"2","key":"9576_CR35","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1148\/radiol.2482072192","volume":"248","author":"WP Shuman","year":"2008","unstructured":"Shuman WP, Branch KR, May JM et al (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248(2):431\u2013437","journal-title":"Radiology"},{"issue":"2","key":"9576_CR36","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1148\/radiol.2482071804","volume":"248","author":"N Hirai","year":"2008","unstructured":"Hirai N, Horiguchi J, Fujioka C et al (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248(2):424\u2013430","journal-title":"Radiology"},{"issue":"3","key":"9576_CR37","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1148\/radiol.2463070989","volume":"246","author":"JP Earls","year":"2008","unstructured":"Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246(3):742\u2013753","journal-title":"Radiology"},{"issue":"9","key":"9576_CR38","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1136\/hrt.2008.149971","volume":"94","author":"H Scheffel","year":"2008","unstructured":"Scheffel H, Alkadhi H, Leschka S et al (2008) Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94(9):1132\u20131137","journal-title":"Heart"},{"key":"9576_CR39","doi-asserted-by":"crossref","unstructured":"Xu L, Yang L, Zhang Z et al (2009) Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: comparison with retrospective ECG gating. Eur J Radiol doi: 10.1016\/j.ejrad.2009.06.003","DOI":"10.1016\/j.ejrad.2009.06.003"},{"issue":"Suppl 1","key":"9576_CR40","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s10554-009-9443-4","volume":"25","author":"SI Choi","year":"2009","unstructured":"Choi SI, George RT, Schuleri KH et al (2009) Recent developments in wide-detector cardiac computed tomography. Int J Cardiovasc Imaging 25(Suppl 1):23\u201329","journal-title":"Int J Cardiovasc Imaging"},{"issue":"3","key":"9576_CR41","doi-asserted-by":"crossref","first-page":"764","DOI":"10.2214\/AJR.09.2397","volume":"193","author":"AK Hara","year":"2009","unstructured":"Hara AK, Paden RG, Silva AC et al (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193(3):764\u2013771","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"9576_CR42","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1148\/radiol.2433061165","volume":"243","author":"CH McCollough","year":"2007","unstructured":"McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243(3):775\u2013784","journal-title":"Radiology"},{"issue":"4","key":"9576_CR43","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/RLI.0b013e318160b3a3","volume":"43","author":"F Hermann","year":"2008","unstructured":"Hermann F, Martinoff S, Meyer T et al (2008) Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery. Invest Radiol 43(4):253\u2013260","journal-title":"Invest Radiol"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-009-9576-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-009-9576-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-009-9576-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T17:12:59Z","timestamp":1559236379000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-009-9576-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,8]]},"references-count":43,"journal-issue":{"issue":"S1","published-print":{"date-parts":[[2010,2]]}},"alternative-id":["9576"],"URL":"https:\/\/doi.org\/10.1007\/s10554-009-9576-5","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1,8]]}}}