{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T07:04:20Z","timestamp":1761807860867},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2013,9,13]],"date-time":"2013-09-13T00:00:00Z","timestamp":1379030400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1007\/s10554-013-0282-y","type":"journal-article","created":{"date-parts":[[2013,9,12]],"date-time":"2013-09-12T08:54:59Z","timestamp":1378976099000},"page":"1677-1683","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography"],"prefix":"10.1007","volume":"29","author":[{"given":"Tian","family":"Feng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Yundai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liu","family":"Hongbin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Lian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sun","family":"Zhijun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guo","family":"Jun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin","family":"Qinhua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhang","family":"Tao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,9,13]]},"reference":[{"key":"282_CR1","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/0735-1097(94)90371-9","volume":"23","author":"A Baumbach","year":"1994","unstructured":"Baumbach A, Bittl JA, Fleck E, Geschwind HJ, Sanborn TA, Tcheng JE et al (1994) Acute complications of excimer laser coronary angioplasty: a detailed analysis of multicenter results. Coinvestigators of the U.S. and European percutaneous excimer laser coronary angioplasty (PELCA) Registries. J Am Coll Cardiol 23:1305\u20131313","journal-title":"J Am Coll Cardiol"},{"key":"282_CR2","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1016\/S0002-9149(97)00055-6","volume":"79","author":"PA Slota","year":"1997","unstructured":"Slota PA, Fischman DL, Savage MP, Rake R, Goldberg S (1997) Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty. STRESS Trial Investigators. Am J Cardiol 79:1104\u20131106","journal-title":"Am J Cardiol"},{"key":"282_CR3","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1161\/01.CIR.0000116202.41966.D4","volume":"109","author":"R Virmani","year":"2004","unstructured":"Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T et al (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109:701\u2013705","journal-title":"Circulation"},{"key":"282_CR4","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jacc.2006.03.042","volume":"48","author":"M Joner","year":"2006","unstructured":"Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R et al (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193\u2013202","journal-title":"J Am Coll Cardiol"},{"key":"282_CR5","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1161\/CIRCULATIONAHA.106.675934","volume":"115","author":"TF L\u00fcscher","year":"2007","unstructured":"L\u00fcscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC et al (2007) Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation 115:1051\u20131058","journal-title":"Circulation"},{"issue":"22","key":"282_CR6","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1016\/j.jacc.2009.01.069","volume":"53","author":"F Alfonso","year":"2009","unstructured":"Alfonso F, Vizcayno MJP, Ruiz M, Su\u00e1rez A, Cazares M, Hern\u00e1ndez R et al (2009) Coronary aneurysms after drug-eluting stent implantation: clinical, angiographic, and intravascular ultrasound findings. J Am Coll Cardiol 53(22):2053\u20132060","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"282_CR7","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1161\/CIRCINTERVENTIONS.109.916502","volume":"3","author":"SJ Kang","year":"2010","unstructured":"Kang SJ, Mintz GS, Park DW, Lee SW, Kim YH, Lee CW et al (2010) Late and very late drug-eluting stent malapposition: serial 2-year quantitative IVUS analysis. Circ Cardiovasc Interv 3(4):335\u2013340","journal-title":"Circ Cardiovasc Interv"},{"issue":"8","key":"282_CR8","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.amjcard.2006.11.068","volume":"99","author":"M Takano","year":"2007","unstructured":"Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K et al (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99(8):1033\u20131038","journal-title":"Am J Cardiol"},{"issue":"8","key":"282_CR9","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1093\/eurheartj\/ehl413","volume":"28","author":"D Matsumoto","year":"2007","unstructured":"Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T et al (2007) Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 28(8):961\u2013967","journal-title":"Eur Heart J"},{"key":"282_CR10","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1136\/hrt.78.2.136","volume":"78","author":"VP Demopoulos","year":"1997","unstructured":"Demopoulos VP, Olympios CD, Fakiolas CN, Pissimissis EG, Economides NM, Adamopoulou E et al (1997) The natural history of aneurysmal coronary artery disease. Heart 78:136\u2013141","journal-title":"Heart"},{"issue":"7","key":"282_CR11","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1161\/01.CIR.0000116751.88818.10","volume":"109","author":"MK Hong","year":"2004","unstructured":"Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM et al (2004) Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109(7):881\u2013886","journal-title":"Circulation"},{"issue":"2","key":"282_CR12","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.ijcard.2008.05.069","volume":"134","author":"J Tanigawa","year":"2009","unstructured":"Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Mar CD (2009) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 134(2):180\u2013188","journal-title":"Int J Cardiol"},{"issue":"12","key":"282_CR13","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1016\/j.amjcard.2006.01.031","volume":"97","author":"T Kume","year":"2006","unstructured":"Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E et al (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97(12):1713\u20131717","journal-title":"Am J Cardiol"},{"key":"282_CR14","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.jcin.2009.01.010","volume":"2","author":"P Moore","year":"2009","unstructured":"Moore P, Barlis P, Spiro J, Ghimire G, Roughton M, Mario CD et al (2009) A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. J Am Coll Cardiol Intv 2:437\u2013444","journal-title":"J Am Coll Cardiol Intv"},{"issue":"9","key":"282_CR15","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.jacc.2007.09.070","volume":"51","author":"M Takano","year":"2008","unstructured":"Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T et al (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Cardiol 51(9):968\u2013969","journal-title":"J Am Cardiol"},{"issue":"5","key":"282_CR16","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jcin.2009.01.012","volume":"2","author":"N Gonzalo","year":"2009","unstructured":"Gonzalo N, Barlis P, Serruys PW, Garcia HM, Onuma Y, Lighart J et al (2009) Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable\/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2(5):445\u2013452","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"282_CR17","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1161\/CIRCULATIONAHA.110.963181","volume":"123","author":"G Guagliumi","year":"2011","unstructured":"Guagliumi G, Costa MA, Sirbu V, Musumeci G, Bezerra HG, Suzuki N et al (2011) Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 123(3):274\u2013281","journal-title":"Circulation"},{"key":"282_CR18","doi-asserted-by":"crossref","first-page":"2426","DOI":"10.1161\/CIRCULATIONAHA.106.658237","volume":"115","author":"S Cook","year":"2007","unstructured":"Cook S, Wenaweser P, Togni M, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426\u20132434","journal-title":"Circulation"},{"issue":"10","key":"282_CR19","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1093\/eurheartj\/ehn553","volume":"31","author":"AK Hassan","year":"2010","unstructured":"Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevieer JWM et al (2010) Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 31(10):1172\u20131180","journal-title":"Eur Heart J"},{"issue":"3","key":"282_CR20","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1161\/CIRCULATIONAHA.105.563403","volume":"113","author":"MK Hong","year":"2006","unstructured":"Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK et al (2006) Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation 113(3):414\u2013419","journal-title":"Circulation"},{"key":"282_CR21","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1161\/ATVBAHA.107.144220","volume":"27","author":"AV Finn","year":"2007","unstructured":"Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK et al (2007) Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 27:1500\u20131510","journal-title":"Arterioscler Thromb Vasc Biol"},{"issue":"8","key":"282_CR22","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1136\/hrt.2005.075960","volume":"92","author":"SJ Hong","year":"2006","unstructured":"Hong SJ, Kim MH, Ahn TH, Ahn YK, Bae JH, Shim WJ et al (2006) Multiple predictors of coronary restenosis after drug-eluting stent implantation in patients with diabetes. Heart 92(8):1119\u20131124","journal-title":"Heart"},{"issue":"1","key":"282_CR23","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.ahj.2008.02.012","volume":"156","author":"GJ Mishkel","year":"2008","unstructured":"Mishkel GJ, Moore AL, Markwell S, Shelton ME (2008) Correlates of late and very late thrombosis of drug eluting stents. Am Heart J 156(1):141\u2013147","journal-title":"Am Heart J"},{"issue":"2","key":"282_CR24","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1159\/000317071","volume":"116","author":"WC Kang","year":"2010","unstructured":"Kang WC, Ahn T, Moon CI, Lee K, Han SH, Shin EK et al (2010) Comparison of the effect of preinterventional arterial remodeling on intimal hyperplasia after implantation of a sirolimus- or paclitaxel-eluting stent. Cardiology 116(2):117\u2013122","journal-title":"Cardiology"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-013-0282-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-013-0282-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-013-0282-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,26]],"date-time":"2019-03-26T18:53:00Z","timestamp":1553626380000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-013-0282-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,13]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["282"],"URL":"https:\/\/doi.org\/10.1007\/s10554-013-0282-y","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,13]]}}}