{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:33:57Z","timestamp":1740123237267,"version":"3.37.3"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2016,12,23]],"date-time":"2016-12-23T00:00:00Z","timestamp":1482451200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000046","name":"Abbott Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000046","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1007\/s10554-016-1033-7","type":"journal-article","created":{"date-parts":[[2016,12,24]],"date-time":"2016-12-24T08:44:36Z","timestamp":1482569076000},"page":"441-449","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparative assessment of \u201cplaque\/media\u201d change on three modalities of IVUS immediately after implantation of either everolimus-eluting bioresorbable vascular scaffold or everolimus-eluting metallic stent in Absorb II study"],"prefix":"10.1007","volume":"33","author":[{"name":"On behalf of the investigators of Absorb II study","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaping","family":"Zeng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafael","family":"Cavalcante","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erhan","family":"Tenekecioglu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pannipa","family":"Suwannasom","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yohei","family":"Sotomi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Collet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahammad","family":"Abdelghani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans","family":"Jonker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franck","family":"Digne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dieter","family":"Horstkotte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manfred","family":"Zehender","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ciro","family":"Indolfi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Saia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rosario","family":"Fiorilli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernard","family":"Chevalier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonardo","family":"Bolognese","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Goicolea","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaoping","family":"Nie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinobu","family":"Onuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick W.","family":"Serruys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,12,23]]},"reference":[{"issue":"22","key":"1033_CR1","doi-asserted-by":"crossref","first-page":"2078","DOI":"10.1056\/NEJMoa1110874","volume":"365","author":"SJ Nicholls","year":"2011","unstructured":"Nicholls SJ et al (2011) Effect of two intensive statin regimens on progression of coronary disease. N Engl J Med 365(22):2078\u20132087","journal-title":"N Engl J Med"},{"issue":"12","key":"1033_CR2","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.jcmg.2013.04.015","volume":"6","author":"CV Bourantas","year":"2013","unstructured":"Bourantas CV et al (2013) Clinical and angiographic characteristics of patients likely to have vulnerable plaques: analysis from the PROSPECT study. JACC Cardiovasc Imaging 6(12):1263\u20131272","journal-title":"JACC Cardiovasc Imaging"},{"issue":"5","key":"1033_CR3","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1016\/S0735-1097(01)01175-5","volume":"37","author":"GS Mintz","year":"2001","unstructured":"Mintz GS et al (2001) American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on clinical expert consensus documents. J Am Coll Cardiol 37(5):1478\u20131492","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"1033_CR4","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1161\/01.ATV.13.4.482","volume":"13","author":"M Wong","year":"1993","unstructured":"Wong M et al (1993) Ultrasonic-pathological comparison of the human arterial wall. Verification of intima-media thickness. Arterioscler Thromb 13(4):482\u2013486","journal-title":"Arterioscler Thromb"},{"issue":"11","key":"1033_CR5","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.4244\/EIJV9I11A217","volume":"9","author":"PW Serruys","year":"2014","unstructured":"Serruys PW et al (2014) Dynamics of vessel wall changes following the implantation of the absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study at 6, 12, 24 and 36 months. EuroIntervention 9(11):1271\u20131284","journal-title":"EuroIntervention"},{"issue":"9962","key":"1033_CR6","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0140-6736(14)61455-0","volume":"385","author":"PW Serruys","year":"2015","unstructured":"Serruys PW et al (2015) A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial. Lancet 385(9962):43\u201354","journal-title":"Lancet"},{"issue":"5","key":"1033_CR7","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/j.ahj.2012.08.010","volume":"164","author":"R Diletti","year":"2012","unstructured":"Diletti R et al (2012) ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design. Am Heart J 164(5):654\u2013663","journal-title":"Am Heart J"},{"issue":"3 Suppl","key":"1033_CR8","doi-asserted-by":"crossref","first-page":"S28","DOI":"10.1016\/j.jcmg.2012.01.009","volume":"5","author":"SL Papadopoulou","year":"2012","unstructured":"Papadopoulou SL et al (2012) Natural history of coronary atherosclerosis by multislice computed tomography. JACC Cardiovasc Imaging 5(3 Suppl):S28\u2013S37","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"1033_CR9","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.recesp.2015.07.031","volume":"69","author":"CM Campos","year":"2016","unstructured":"Campos CM et al (2016) Impact of the everolimus-eluting bioresorbable scaffold in coronary atherosclerosis. Rev Esp Cardiol (Engl Ed) 69(2):109\u2013116","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"issue":"9","key":"1033_CR10","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.4244\/EIJV6I9A195","volume":"6","author":"GS Mintz","year":"2011","unstructured":"Mintz GS et al (2011) Clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound regression\/progression studies. EuroIntervention 6(9):1123\u20131130","journal-title":"EuroIntervention"},{"issue":"7","key":"1033_CR11","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.jcmg.2011.04.007","volume":"4","author":"R Diletti","year":"2011","unstructured":"Diletti R et al (2011) Assessment of coronary atherosclerosis progression and regression at bifurcations using combined IVUS and OCT. JACC Cardiovasc Imaging 4(7):774\u2013780","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"1033_CR12","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jjcc.2014.05.004","volume":"65","author":"T Muramatsu","year":"2015","unstructured":"Muramatsu T et al (2015) Reproducibility of intravascular ultrasound radiofrequency data analysis (virtual histology) with a 45-MHz rotational imaging catheter in ex vivo human coronary arteries. J Cardiol 65(2):134\u2013142","journal-title":"J Cardiol"},{"issue":"3","key":"1033_CR13","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1007\/s10554-011-9829-y","volume":"28","author":"JL Gutierrez-Chico","year":"2012","unstructured":"Gutierrez-Chico JL et al (2012) Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT. Int J Cardiovasc Imaging 28(3):467\u2013478","journal-title":"Int J Cardiovasc Imaging"},{"issue":"17","key":"1033_CR14","doi-asserted-by":"crossref","first-page":"2292","DOI":"10.1001\/jama.290.17.2292","volume":"290","author":"SE Nissen","year":"2003","unstructured":"Nissen SE et al (2003) Effect of recombinant ApoA-I Milano on coronary atherosclerosis in patients with acute coronary syndromes: a randomized controlled trial. JAMA 290(17):2292\u20132300","journal-title":"JAMA"},{"issue":"2","key":"1033_CR15","doi-asserted-by":"crossref","first-page":"177","DOI":"10.4244\/EIJV5I2A29","volume":"5","author":"HM Garcia-Garcia","year":"2009","unstructured":"Garcia-Garcia HM et al (2009) Tissue characterisation using intravascular radiofrequency data analysis: recommendations for acquisition, analysis, interpretation and reporting. EuroIntervention 5(2):177\u2013189","journal-title":"EuroIntervention"},{"issue":"6","key":"1033_CR16","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1007\/s10554-010-9724-y","volume":"27","author":"S Brugaletta","year":"2011","unstructured":"Brugaletta S et al (2011) Temporal changes of coronary artery plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold. Int J Cardiovasc Imaging 27(6):859\u2013866","journal-title":"Int J Cardiovasc Imaging"},{"issue":"4","key":"1033_CR17","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1161\/hc2901.093188","volume":"104","author":"M Schartl","year":"2001","unstructured":"Schartl M et al (2001) Use of intravascular ultrasound to compare effects of different strategies of lipid-lowering therapy on plaque volume and composition in patients with coronary artery disease. Circulation 104(4):387\u2013392","journal-title":"Circulation"},{"issue":"4","key":"1033_CR18","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/0002-8703(95)90307-0","volume":"129","author":"Q Rasheed","year":"1995","unstructured":"Rasheed Q et al (1995) Intracoronary ultrasound-defined plaque composition: computer-aided plaque characterization and correlation with histologic samples obtained during directional coronary atherectomy. Am Heart J 129(4):631\u2013637","journal-title":"Am Heart J"},{"issue":"3","key":"1033_CR19","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s10554-015-0591-4","volume":"31","author":"CM Campos","year":"2015","unstructured":"Campos CM et al (2015) Echogenicity as a surrogate for bioresorbable everolimus-eluting scaffold degradation: analysis at 1-, 3-, 6-, 12\u201318, 24-, 30-, 36- and 42-month follow-up in a porcine model. Int J Cardiovasc Imaging 31(3):471\u2013482","journal-title":"Int J Cardiovasc Imaging"},{"issue":"4","key":"1033_CR20","doi-asserted-by":"crossref","first-page":"443","DOI":"10.4244\/EIJV4I4A77","volume":"4","author":"HM Garcia-Garcia","year":"2009","unstructured":"Garcia-Garcia HM et al (2009) Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis. A substudy of the ABSORB clinical trial. EuroIntervention 4(4):443\u2013448","journal-title":"EuroIntervention"},{"issue":"22","key":"1033_CR21","doi-asserted-by":"crossref","first-page":"2301","DOI":"10.1161\/CIRCULATIONAHA.110.970772","volume":"122","author":"PW Serruys","year":"2010","unstructured":"Serruys PW et al (2010) Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes. Circulation 122(22):2301\u20132312","journal-title":"Circulation"},{"issue":"5","key":"1033_CR22","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1161\/CIRCINTERVENTIONS.112.971549","volume":"5","author":"JA Ormiston","year":"2012","unstructured":"Ormiston JA et al (2012) First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study. Circ Cardiovasc Interv 5(5):620\u2013632","journal-title":"Circ Cardiovasc Interv"},{"key":"1033_CR23","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehw097","author":"CV Bourantas","year":"2016","unstructured":"Bourantas CV et al (2016) Hybrid intravascular imaging: recent advances, technical considerations, and current applications in the study of plaque pathophysiology. Eur Heart J. doi: 10.1093\/eurheartj\/ehw097","journal-title":"Eur Heart J"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-016-1033-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-016-1033-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-016-1033-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,25]],"date-time":"2017-06-25T02:40:52Z","timestamp":1498358452000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-016-1033-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12,23]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["1033"],"URL":"https:\/\/doi.org\/10.1007\/s10554-016-1033-7","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"type":"print","value":"1569-5794"},{"type":"electronic","value":"1573-0743"}],"subject":[],"published":{"date-parts":[[2016,12,23]]}}}