{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T20:16:19Z","timestamp":1790799379560,"version":"4.1.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2018,1,16]],"date-time":"2018-01-16T00:00:00Z","timestamp":1516060800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["15H06478"],"award-info":[{"award-number":["15H06478"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1007\/s10554-018-1297-1","type":"journal-article","created":{"date-parts":[[2018,1,16]],"date-time":"2018-01-16T01:07:16Z","timestamp":1516064836000},"page":"931-937","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Noninvasive quantification of left-to-right shunt by phase contrast magnetic resonance imaging in secundum atrial septal defect: the effects of breath holding and comparison with invasive oximetry"],"prefix":"10.1007","volume":"34","author":[{"given":"Yuzo","family":"Yamasaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Kawanami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Kamitani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koji","family":"Sagiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ichiro","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken-ichi","family":"Hiasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetake","family":"Yabuuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michinobu","family":"Nagao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Honda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,1,16]]},"reference":[{"key":"1297_CR1","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.ahj.2003.05.003","volume":"147","author":"JI Hoffman","year":"2004","unstructured":"Hoffman JI, Kaplan S, Liberthson RR (2004) Prevalence of congenital heart disease. Am Heart J 147:425\u2013439","journal-title":"Am Heart J"},{"key":"1297_CR2","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1016\/j.echo.2015.05.015","volume":"28","author":"FE Silvestry","year":"2015","unstructured":"Silvestry FE, Cohen MS, Armsby LB et al (2015) Guidelines for the echocardiographic assessment of atrial septal defect and patent foramen ovale: from the American Society of Echocardiography and Society for Cardiac Angiography and Interventions. J Am Soc Echocardiogr 28:910\u2013958","journal-title":"J Am Soc Echocardiogr"},{"key":"1297_CR3","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s12471-015-0663-z","volume":"23","author":"JM Kuijpers","year":"2015","unstructured":"Kuijpers JM, Mulder BJ, Bouma BJ (2015) Secundum atrial septal defect in adults: a practical review and recent developments. Neth Heart J 23:205\u2013211","journal-title":"Neth Heart J"},{"key":"1297_CR4","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1259\/bjr\/18500608","volume":"82","author":"K Debl","year":"2009","unstructured":"Debl K, Djavidani B, Buchner S et al (2009) Quantification of left-to-right shunting in adult congenital heart disease: phase-contrast cine MRI compared with invasive oximetry. Br J Radiol 82:386\u2013391","journal-title":"Br J Radiol"},{"key":"1297_CR5","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.1161\/01.CIR.103.20.2476","volume":"103","author":"P Beerbaum","year":"2001","unstructured":"Beerbaum P, Korperich H, Barth P, Esdorn H, Gieseke J, Meyer H (2001) Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry. Circulation 103:2476\u20132482","journal-title":"Circulation"},{"key":"1297_CR6","doi-asserted-by":"publisher","first-page":"1246","DOI":"10.1016\/0735-1097(92)90384-Y","volume":"20","author":"LD Brenner","year":"1992","unstructured":"Brenner LD, Caputo GR, Mostbeck G et al (1992) Quantification of left to right atrial shunts with velocity-encoded cine nuclear magnetic resonance imaging. J Am Coll Cardiol 20:1246\u20131250","journal-title":"J Am Coll Cardiol"},{"key":"1297_CR7","doi-asserted-by":"publisher","first-page":"2955","DOI":"10.1161\/01.CIR.91.12.2955","volume":"91","author":"WG Hundley","year":"1995","unstructured":"Hundley WG, Li HF, Lange RA et al (1995) Assessment of left-to-right intracardiac shunting by velocity-encoded, phase-difference magnetic resonance imaging. A comparison with oximetric and indicator dilution techniques. Circulation 91:2955\u20132960","journal-title":"Circulation"},{"key":"1297_CR8","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.ejrad.2006.08.026","volume":"61","author":"S Ley","year":"2007","unstructured":"Ley S, Ley-Zaporozhan J, Kreitner KF et al (2007) MR flow measurements for assessment of the pulmonary, systemic and bronchosystemic circulation: impact of different ECG gating methods and breathing schema. Eur J Radiol 61:124\u2013129","journal-title":"Eur J Radiol"},{"key":"1297_CR9","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1002\/1522-2594(200102)45:2<346::AID-MRM1044>3.0.CO;2-I","volume":"45","author":"H Sakuma","year":"2001","unstructured":"Sakuma H, Kawada N, Kubo H et al (2001) Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI. Magn Reson Med 45:346\u2013348","journal-title":"Magn Reson Med"},{"key":"1297_CR10","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1161\/01.CIR.0000087603.97036.C2","volume":"108","author":"P Beerbaum","year":"2003","unstructured":"Beerbaum P, Korperich H, Gieseke J, Barth P, Peuster M, Meyer H (2003) Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation 108:1355\u20131361","journal-title":"Circulation"},{"key":"1297_CR11","doi-asserted-by":"publisher","first-page":"439","DOI":"10.2214\/AJR.04.1738","volume":"187","author":"S Ley","year":"2006","unstructured":"Ley S, Fink C, Puderbach M et al (2006) MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers. AJR Am J Roentgenol 187:439\u2013444","journal-title":"AJR Am J Roentgenol"},{"key":"1297_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1532-429X-11-1","volume":"11","author":"B Johansson","year":"2009","unstructured":"Johansson B, Babu-Narayan SV, Kilner PJ (2009) The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mapping. J Cardiovasc Magn Reson 11:1","journal-title":"J Cardiovasc Magn Reson"},{"key":"1297_CR13","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1002\/jmri.1880030315","volume":"3","author":"PG Walker","year":"1993","unstructured":"Walker PG, Cranney GB, Scheidegger MB, Waseleski G, Pohost GM, Yoganathan AP (1993) Semiautomated method for noise reduction and background phase error correction in MR phase velocity data. J Magn Reson Imaging 3:521\u2013530","journal-title":"J Magn Reson Imaging"},{"key":"1297_CR14","volume-title":"Grossman\u2019s cardiac catheterization, angiography, and intervention","author":"DS Baim","year":"2006","unstructured":"Baim DS, Grossman W (2006) Grossman\u2019s cardiac catheterization, angiography, and intervention, 7th\u00a0edn. Lippincott Williams & Wilkins, Philadelphia","edition":"7"},{"key":"1297_CR15","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1016\/S0735-1097(02)01862-4","volume":"39","author":"ZD Du","year":"2002","unstructured":"Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K (2002) Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol 39:1836\u20131844","journal-title":"J Am Coll Cardiol"},{"key":"1297_CR16","doi-asserted-by":"publisher","first-page":"1871","DOI":"10.1152\/jappl.1986.60.6.1871","volume":"60","author":"M Ferrigno","year":"1986","unstructured":"Ferrigno M, Hickey DD, Liner MH, Lundgren CE (1986) Cardiac performance in humans during breath holding. J Appl Physiol 60:1871\u20131877","journal-title":"J Appl Physiol"},{"key":"1297_CR17","first-page":"507","volume":"13","author":"CJ Porth","year":"1984","unstructured":"Porth CJ, Bamrah VS, Tristani FE, Smith JJ (1984) The Valsalva maneuver: mechanisms and clinical implications. Heart Lung 13:507\u2013518","journal-title":"Heart Lung"},{"key":"1297_CR18","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1378\/chest.98.5.1175","volume":"98","author":"LM Tsai","year":"1990","unstructured":"Tsai LM, Chen JH (1990) Abnormal hemodynamic response to Valsalva maneuver in patients with atrial septal defect evaluated by Doppler echocardiography. Chest 98:1175\u20131178","journal-title":"Chest"},{"key":"1297_CR19","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1093\/oxfordjournals.eurheartj.a061088","volume":"16","author":"J Virolainen","year":"1995","unstructured":"Virolainen J, Ventila M, Turto H, Kupari M (1995) Influence of negative intrathoracic pressure on right atrial and systemic venous dynamics. Eur Heart J 16:1293\u20131299","journal-title":"Eur Heart J"},{"key":"1297_CR20","doi-asserted-by":"publisher","first-page":"3180","DOI":"10.1007\/s00330-015-4120-6","volume":"26","author":"A Chaturvedi","year":"2016","unstructured":"Chaturvedi A, Hamilton-Craig C, Cawley PJ, Mitsumori LM, Otto CM, Maki JH (2016) Quantitating aortic regurgitation by cardiovascular magnetic resonance: significant variations due to slice location and breath holding. Eur Radiol 26:3180\u20133189","journal-title":"Eur Radiol"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-018-1297-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-018-1297-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-018-1297-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,1,15]],"date-time":"2019-01-15T19:26:05Z","timestamp":1547580365000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-018-1297-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,16]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["1297"],"URL":"https:\/\/doi.org\/10.1007\/s10554-018-1297-1","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,16]]},"assertion":[{"value":"23 August 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"S. Kawanami: Bayer Healthcare Japan, Modest, Research Grant; Philips Electronics Japan, Modest, Research Grant. Other authors: None.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by our institutional review board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Written informed consent was obtained from each patient prior to imaging.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}