{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T16:12:22Z","timestamp":1787242342280,"version":"build-2736575974"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2018,5,5]],"date-time":"2018-05-05T00:00:00Z","timestamp":1525478400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["KAKENHI (17K16452)"],"award-info":[{"award-number":["KAKENHI (17K16452)"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1007\/s10554-018-1363-8","type":"journal-article","created":{"date-parts":[[2018,5,5]],"date-time":"2018-05-05T07:51:43Z","timestamp":1525506703000},"page":"1485-1491","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease"],"prefix":"10.1007","volume":"34","author":[{"given":"Yuzo","family":"Yamasaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Kawanami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Kamitani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koji","family":"Sagiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seitaro","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Hino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hazumu","family":"Nagata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetake","family":"Yabuuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michinobu","family":"Nagao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Honda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,5,5]]},"reference":[{"key":"1363_CR1","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1007\/s00246-004-0640-6","volume":"26","author":"M Ruzmetov","year":"2005","unstructured":"Ruzmetov M, Jimenez MA, Pruitt A, Turrentine MW, Brown JW (2005) Repair of tetralogy of Fallot with anomalous coronary arteries coursing across the obstructed right ventricular outflow tract. Pediatr Cardiol 26:537\u2013542","journal-title":"Pediatr Cardiol"},{"key":"1363_CR2","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s00247-008-1111-7","volume":"39","author":"HW Goo","year":"2009","unstructured":"Goo HW, Seo DM, Yun TJ et al (2009) Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings. Pediatr Radiol 39:265\u2013273","journal-title":"Pediatr Radiol"},{"key":"1363_CR3","doi-asserted-by":"publisher","first-page":"1980","DOI":"10.1161\/01.CIR.0000033518.61709.56","volume":"106","author":"P Massoudy","year":"2002","unstructured":"Massoudy P, Baltalarli A, de Leval MR et al (2002) Anatomic variability in coronary arterial distribution with regard to the arterial switch procedure. Circulation 106:1980\u20131984","journal-title":"Circulation"},{"key":"1363_CR4","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1007\/s10554-011-0005-1","volume":"28","author":"T Zhang","year":"2012","unstructured":"Zhang T, Wang W, Luo Z et al (2012) Initial experience on the application of 320-row CT angiography with low-dose prospective ECG-triggered in children with congenital heart disease. Int J Cardiovasc Imaging 28:1787\u20131797","journal-title":"Int J Cardiovasc Imaging"},{"key":"1363_CR5","doi-asserted-by":"publisher","first-page":"e91123","DOI":"10.1371\/journal.pone.0091123","volume":"9","author":"P Nie","year":"2014","unstructured":"Nie P, Li H, Duan Y et al (2014) Impact of sinogram affirmed iterative reconstruction (SAFIRE) algorithm on image quality with 70 kVp-tube-voltage dual-source CT angiography in children with congenital heart disease. PLoS ONE 9:e91123","journal-title":"PLoS ONE"},{"key":"1363_CR6","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1259\/bjr\/15296170","volume":"85","author":"Z Sun","year":"2012","unstructured":"Sun Z, Choo GH, Ng KH (2012) Coronary CT angiography: current status and continuing challenges. Br J Radiol 85:495\u2013510","journal-title":"Br J Radiol"},{"issue":"Suppl 2","key":"1363_CR7","first-page":"S111","volume":"83","author":"J Soongswang","year":"2000","unstructured":"Soongswang J, Nana A, Laohaprasitiporn D et al (2000) Limitation of transthoracic echocardiography in the diagnosis of congenital heart diseases. J Med Assoc Thai 83(Suppl 2):S111\u2013S117","journal-title":"J Med Assoc Thai"},{"key":"1363_CR8","unstructured":"Shrimpton PC (2004) Assessment of patient dose in CT. NRPBPE\/1\/2004"},{"key":"1363_CR9","doi-asserted-by":"publisher","first-page":"1670","DOI":"10.1007\/s00247-010-1693-8","volume":"40","author":"HW Goo","year":"2010","unstructured":"Goo HW, Yang DH (2010) Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan. Pediatr Radiol 40:1670\u20131680","journal-title":"Pediatr Radiol"},{"key":"1363_CR10","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1007\/s00247-005-1482-y","volume":"35","author":"HW Goo","year":"2005","unstructured":"Goo HW, Park IS, Ko JK et al (2005) Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol 35:792\u2013798","journal-title":"Pediatr Radiol"},{"key":"1363_CR11","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1016\/S0735-1097(98)00396-9","volume":"32","author":"R Vitiello","year":"1998","unstructured":"Vitiello R, McCrindle BW, Nykanen D, Freedom RM, Benson LN (1998) Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 32:1433\u20131440","journal-title":"J Am Coll Cardiol"},{"key":"1363_CR12","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1161\/01.CIR.0000151098.52656.3A","volume":"111","author":"K Bacher","year":"2005","unstructured":"Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83\u201389","journal-title":"Circulation"},{"key":"1363_CR13","doi-asserted-by":"publisher","first-page":"e0137165","DOI":"10.1371\/journal.pone.0137165","volume":"10","author":"R Kakinuma","year":"2015","unstructured":"Kakinuma R, Moriyama N, Muramatsu Y et al (2015) Ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner. PLoS ONE 10:e0137165","journal-title":"PLoS ONE"},{"key":"1363_CR14","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1253\/circj.CJ-13-1101","volume":"78","author":"N Kawaguchi","year":"2014","unstructured":"Kawaguchi N, Kurata A, Kido T et al (2014) Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material. Circ J 78:662\u2013670","journal-title":"Circ J"},{"key":"1363_CR15","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1007\/s00330-007-0773-0","volume":"18","author":"F Cademartiri","year":"2008","unstructured":"Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18:576\u2013583","journal-title":"Eur Radiol"},{"key":"1363_CR16","doi-asserted-by":"publisher","first-page":"43","DOI":"10.2214\/AJR.07.2653","volume":"191","author":"X Fei","year":"2008","unstructured":"Fei X, Du X, Yang Q et al (2008) 64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis. AJR Am J Roentgenol 191:43\u201349","journal-title":"AJR Am J Roentgenol"},{"key":"1363_CR17","doi-asserted-by":"publisher","first-page":"2503","DOI":"10.1007\/s00330-010-1822-7","volume":"20","author":"Z Cheng","year":"2010","unstructured":"Cheng Z, Wang X, Duan Y et al (2010) Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 20:2503\u20132511","journal-title":"Eur Radiol"},{"key":"1363_CR18","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1007\/s00247-011-2079-2","volume":"41","author":"MP Huang","year":"2011","unstructured":"Huang MP, Liang CH, Zhao ZJ et al (2011) Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease. Pediatr Radiol 41:858\u2013866","journal-title":"Pediatr Radiol"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-018-1363-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-018-1363-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-018-1363-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,6]],"date-time":"2019-05-06T10:16:02Z","timestamp":1557137762000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-018-1363-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,5]]},"references-count":18,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2018,9]]}},"alternative-id":["1363"],"URL":"https:\/\/doi.org\/10.1007\/s10554-018-1363-8","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,5]]},"assertion":[{"value":"22 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Satoshi Kawanami: Bayer Healthcare Japan, Modest, Research Grant; Philips Electronics Japan, Modest, Research Grant. Other authors: none.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}