{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,5]],"date-time":"2026-07-05T12:53:07Z","timestamp":1783255987058,"version":"3.54.6"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2019,7,4]],"date-time":"2019-07-04T00:00:00Z","timestamp":1562198400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,7,4]],"date-time":"2019-07-04T00:00:00Z","timestamp":1562198400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2019,11]]},"DOI":"10.1007\/s10554-019-01658-x","type":"journal-article","created":{"date-parts":[[2019,7,4]],"date-time":"2019-07-04T13:30:09Z","timestamp":1562247009000},"page":"2103-2112","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Non-invasive CT-derived fractional flow reserve and static rest and stress CT myocardial perfusion imaging for detection of haemodynamically significant coronary stenosis"],"prefix":"10.1007","volume":"35","author":[{"given":"Brian S.","family":"Ko","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesper J.","family":"Linde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdul-Rahman","family":"Ihdayhid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bjarne L.","family":"Norgaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus F.","family":"Kofoed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathias","family":"S\u00f8rgaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Adams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Crossett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James D.","family":"Cameron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujith K.","family":"Seneviratne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,7,4]]},"reference":[{"key":"1658_CR1","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1056\/NEJMoa1205361","volume":"367","author":"B De Bruyne","year":"2012","unstructured":"De Bruyne B, Pijls NH, Kalesan B et al (2012) Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease. N Engl J Med 367:991\u20131001","journal-title":"N Engl J Med"},{"key":"1658_CR2","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1161\/01.CIR.97.6.535","volume":"97","author":"R Hachamovitch","year":"1998","unstructured":"Hachamovitch R, Berman DS, Shaw LJ et al (1998) Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction. Circulation 97:535\u2013543","journal-title":"Circulation"},{"key":"1658_CR3","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1016\/j.jacc.2013.11.043","volume":"63","author":"BL Norgaard","year":"2014","unstructured":"Norgaard BL, Leipsic J, Gaur S et al (2014) Diagnostic performance of non-invasive fractional flow reserve derived from coronary CT angiography in suspected coronary artery disease: the NXT trial. J Am Coll Cardiol 63:1145\u20131155","journal-title":"J Am Coll Cardiol"},{"key":"1658_CR4","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jacc.2012.12.020","volume":"61","author":"N Bettencourt","year":"2013","unstructured":"Bettencourt N, Chiribiri A, Schuster A et al (2013) Direct comparison of cardiac magnetic resonance and multidetector computed tomography stress-rest perfusion imaging for detection of coronary artery disease. J Am Coll Cardiol 61:1099\u20131107","journal-title":"J Am Coll Cardiol"},{"key":"1658_CR5","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.jcct.2011.10.010","volume":"5","author":"VC Mehra","year":"2011","unstructured":"Mehra VC, Valdiviezo C, Arbab-Zadeh A et al (2011) A stepwise approach to the visual interpretation of CT-based myocardial perfusion. J Cardiovasc Comput Tomogr 5:357\u2013369","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"1658_CR6","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1016\/j.jacc.2012.11.083","volume":"61","author":"CA Taylor","year":"2013","unstructured":"Taylor CA, Fonte TA, Min JK (2013) Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis. J Am Coll Cardiol 61:2233\u20132241","journal-title":"J Am Coll Cardiol"},{"key":"1658_CR7","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1056\/NEJMoa1408758","volume":"371","author":"B De Bruyne","year":"2014","unstructured":"De Bruyne B, Fearon WF, Pijls NH et al (2014) Fractional flow reserve-guided PCI for stable coronary artery disease. N Engl J Med 371:1208\u20131217","journal-title":"N Engl J Med"},{"key":"1658_CR8","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.jcmg.2012.09.004","volume":"5","author":"BS Ko","year":"2012","unstructured":"Ko BS, Cameron JD, Leung M et al (2012) Combined CT coronary angiography and stress myocardial perfusion imaging for hemodynamically significant stenoses in patients with suspected coronary artery disease: a comparison with fractional flow reserve. JACC Cardiovasc Imaging 5:1097\u20131111","journal-title":"JACC Cardiovasc Imaging"},{"key":"1658_CR9","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1161\/CIRCIMAGING.108.813766","volume":"2","author":"RT George","year":"2009","unstructured":"George RT, Arbab-Zadeh A, Miller JM et al (2009) Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging 2:174\u2013182","journal-title":"Circ Cardiovasc Imaging"},{"key":"1658_CR10","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.jcct.2009.03.004","volume":"3","author":"S Abbara","year":"2009","unstructured":"Abbara S, Arbab-Zadeh A, Callister TQ et al (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3:190\u2013204","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"1658_CR11","first-page":"539","volume":"18","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Int J Cardiovasc Imaging 18:539\u2013542","journal-title":"Int J Cardiovasc Imaging"},{"key":"1658_CR12","doi-asserted-by":"publisher","first-page":"837","DOI":"10.2307\/2531595","volume":"44","author":"ER DeLong","year":"1988","unstructured":"DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837\u2013845","journal-title":"Biometrics"},{"key":"1658_CR13","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3","volume":"3","author":"WJ Youden","year":"1950","unstructured":"Youden WJ (1950) Index for rating diagnostic tests. Cancer 3:32\u201335","journal-title":"Cancer"},{"key":"1658_CR14","doi-asserted-by":"publisher","first-page":"e002666","DOI":"10.1161\/CIRCIMAGING.114.002666","volume":"8","author":"RA Takx","year":"2015","unstructured":"Takx RA, Blomberg BA, El Aidi H et al (2015) Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis. Circ Cardiovasc Imaging 8:e002666","journal-title":"Circ Cardiovasc Imaging"},{"key":"1658_CR15","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/j.jcmg.2016.09.028","volume":"10","author":"A Coenen","year":"2017","unstructured":"Coenen A, Rossi A, Lubbers MM et al (2017) Integrating CT myocardial perfusion and CT-FFR in the work-up of coronary artery disease. JACC Cardiovasc Imaging 10:760\u2013770","journal-title":"JACC Cardiovasc Imaging"},{"key":"1658_CR16","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1093\/ehjci\/jew094","volume":"18","author":"DH Yang","year":"2017","unstructured":"Yang DH, Kim YH, Roh JH et al (2017) Diagnostic performance of on-site CT-derived fractional flow reserve versus CT perfusion. Eur Heart J Cardiovas Imaging 18:432\u2013440","journal-title":"Eur Heart J Cardiovas Imaging"},{"key":"1658_CR17","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1093\/ehjci\/jey114","volume":"19","author":"AR Ihdayhid","year":"2018","unstructured":"Ihdayhid AR, Sakaguchi T, Linde JJ et al (2018) Performance of computed tomography-derived fractional flow reserve using reduced-order modelling and static computed tomography stress myocardial perfusion imaging for detection of haemodynamically significant coronary stenosis. Eur Heart J Cardiovasc Imaging 19:1234\u20131243","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1658_CR18","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1001\/jamacardio.2017.2471","volume":"2","author":"I Danad","year":"2017","unstructured":"Danad I, Raijmakers PG, Driessen RS et al (2017) Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol 2:1100\u20131107","journal-title":"JAMA Cardiol"},{"key":"1658_CR19","first-page":"991","volume":"38","author":"I Danad","year":"2016","unstructured":"Danad I, Szymonifka J, Twisk JW et al (2016) Diagnostic performance of cardiac imaging methods to diagnose ischaemia-causing coronary artery disease when directly compared with fractional flow reserve as a reference standard: a meta-analysis. Eur Heart J 38:991\u2013998","journal-title":"Eur Heart J"},{"key":"1658_CR20","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1016\/j.jcmg.2018.05.004","volume":"11","author":"NPR Sand","year":"2018","unstructured":"Sand NPR, Veien KT, Nielsen SS et al (2018) Prospective comparison of FFR derived from coronary CT angiography with SPECT perfusion imaging in stable coronary artery disease: the ReASSESS study. JACC Cardiovasc Imaging 11:1640\u20131650","journal-title":"JACC Cardiovasc Imaging"},{"key":"1658_CR21","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1093\/ehjci\/jex342","volume":"19","author":"L Nissen","year":"2018","unstructured":"Nissen L, Winther S, Westra J et al (2018) Diagnosing coronary artery disease after a positive coronary computed tomography angiography: the Dan-NICAD open label, parallel, head to head, randomized controlled diagnostic accuracy trial of cardiovascular magnetic resonance and myocardial perfusion scintigraphy. Eur Heart J Cardiovasc Imaging 19:369\u2013377","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1658_CR22","doi-asserted-by":"publisher","first-page":"2557","DOI":"10.1161\/CIRCULATIONAHA.112.001345","volume":"128","author":"M Echavarria-Pinto","year":"2013","unstructured":"Echavarria-Pinto M, Escaned J, Macias E et al (2013) Disturbed coronary hemodynamics in vessels with intermediate stenoses evaluated with fractional flow reserve: a combined analysis of epicardial and microcirculatory involvement in ischemic heart disease. Circulation 128:2557\u20132566","journal-title":"Circulation"},{"key":"1658_CR23","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/j.jacc.2017.11.054","volume":"71","author":"RS Driessen","year":"2018","unstructured":"Driessen RS, Stuijfzand WJ, Raijmakers PG et al (2018) Effect of plaque burden and morphology on myocardial blood flow and fractional flow reserve. J Am Coll Cardiol 71:499\u2013509","journal-title":"J Am Coll Cardiol"},{"key":"1658_CR24","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.amjcard.2011.03.073","volume":"108","author":"J Rodes-Cabau","year":"2011","unstructured":"Rodes-Cabau J, Gutierrez M, Courtis J et al (2011) Importance of diffuse atherosclerosis in the functional evaluation of coronary stenosis in the proximal-mid segment of a coronary artery by myocardial fractional flow reserve measurements. Am J Cardiol 108:483\u2013490","journal-title":"Am J Cardiol"},{"key":"1658_CR25","doi-asserted-by":"publisher","first-page":"1476","DOI":"10.1016\/j.jacc.2013.03.088","volume":"62","author":"M Rief","year":"2013","unstructured":"Rief M, Zimmermann E, Stenzel F et al (2013) Computed tomography angiography and myocardial computed tomography perfusion in patients with coronary stents: prospective intraindividual comparison with conventional coronary angiography. J Am Coll Cardiol 62:1476\u20131485","journal-title":"J Am Coll Cardiol"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-019-01658-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10554-019-01658-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-019-01658-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,2]],"date-time":"2020-07-02T23:14:35Z","timestamp":1593731675000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10554-019-01658-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,4]]},"references-count":25,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["1658"],"URL":"https:\/\/doi.org\/10.1007\/s10554-019-01658-x","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,4]]},"assertion":[{"value":"12 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Associate Professor Brian Ko has been an invited speaker at symposiums sponsored by Canon Medical, St Jude, Pfizer, Bristol-Myers Squibb, Medtronic and Lilly. Associate Professor Sujith Seneviratne, Dr Jesper Linde, Dr Abdul-Rahman Ihdayhid and Dr Mathias Sorgaard have been invited speakers at Canon Medical sponsored meeting. Associate Professor Bjarne L. Norgaard has received institutional unrestricted research grants from Siemens and Heartflow. Dr Klaus F Kofoed has received institutional unrestricted research grants form Canon Medical and has been an invited speaker at symposiums sponsored by Canon Medical. The remaining authors have no relevant disclosures. This is otherwise an investigator initiated trial. There is no input to the study from any CT vendor or software company. HeartFlow acted as the core-lab for FFRCT assessment, but had no input in the study design, data analysis, interpretation of results or manuscript preparation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}