{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T17:04:35Z","timestamp":1790096675652,"version":"4.0.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,10,30]],"date-time":"2019-10-30T00:00:00Z","timestamp":1572393600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,10,30]],"date-time":"2019-10-30T00:00:00Z","timestamp":1572393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s10554-019-01719-1","type":"journal-article","created":{"date-parts":[[2019,10,31]],"date-time":"2019-10-31T07:47:19Z","timestamp":1572508039000},"page":"217-230","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Vulnerable struts with CRE8, Biomatrix and Xience stents assessed with OCT and their correlation with clinical variables at 6-month follow-up: the CREBX-OCT study"],"prefix":"10.1007","volume":"36","clinical-trial-number":[{"clinical-trial-number":"nct02850497","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8540-2655","authenticated-orcid":false,"given":"Cristina","family":"Giglioli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiara","family":"Formentini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salvatore Mario","family":"Romano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emanuele","family":"Cecchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giorgio Jacopo","family":"Baldereschi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele","family":"Landi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Chiostri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Prati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niccol\u00f2","family":"Marchionni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,10,30]]},"reference":[{"key":"1719_CR1","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1093\/eurheartj\/ehr479","volume":"33","author":"G Sarno","year":"2012","unstructured":"Sarno G, Lagerqvist B, Frobert O, Nilsson J, Olivecrona G, Omerovic E, Saleh N, Venetzanos D, James S (2012) Lower risk of stent thrombosis and restenosis with unrestricted use of \u201cnew-generation\u201d drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eur Heart J 33:606\u2013613","journal-title":"Eur Heart J"},{"key":"1719_CR2","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1111\/joic.12028","volume":"3","author":"CJ Van Dyck","year":"2013","unstructured":"Van Dyck CJ, Hoymans VY, Haine S, Vrints CJ (2013) New-generation drug-eluting stents: focus on Xience V\u00ae Everolimus-eluting stent and Resolute\u00ae Zotarolimus-Eluting Stent. J Interv Cardiol 3:278\u2013286","journal-title":"J Interv Cardiol"},{"key":"1719_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s12928-014-0281-5","volume":"30","author":"M Nakano","year":"2015","unstructured":"Nakano M, Virmani R (2015) Histopathology of vascular response to drug-eluting stents: an insight from human autopsy into daily practice. Cardiovasc Interv Ther 30:1\u201311","journal-title":"Cardiovasc Interv Ther"},{"key":"1719_CR4","doi-asserted-by":"publisher","first-page":"2088","DOI":"10.1016\/j.jacc.2005.02.086","volume":"45","author":"AT Ong","year":"2005","unstructured":"Ong AT, McFadden EP, Regar E, De Jaegere PP, Van Domburg RT, Serruys PW (2005) Late angiographic stent thrombosis (LAST) events with drug-eluting stents. J Am Coll Cardiol 45:2088\u20132092","journal-title":"J Am Coll Cardiol"},{"key":"1719_CR5","doi-asserted-by":"publisher","first-page":"2584","DOI":"10.1016\/j.jacc.2006.10.026","volume":"48","author":"M Pfisterer","year":"2006","unstructured":"Pfisterer M, Brunner-LaRocca HP, Buser PT, Rickenbacher P, Hunziker P, Mueller C, Jeger R, Bader F, Osswald S, Kaiser C, BASKET-LATE Investigators (2006) Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol 48:2584\u20132591","journal-title":"J Am Coll Cardiol"},{"key":"1719_CR6","doi-asserted-by":"publisher","first-page":"1701","DOI":"10.1161\/01.CIR.0000091115.05480.B0","volume":"108","author":"A Farb","year":"2003","unstructured":"Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701\u20131706","journal-title":"Circulation"},{"key":"1719_CR7","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.jacc.2006.03.042","volume":"48","author":"M Joner","year":"2006","unstructured":"Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193\u2013202","journal-title":"J Am Coll Cardiol"},{"key":"1719_CR8","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1161\/01.CIR.103.15.1967","volume":"103","author":"DE Cutlip","year":"2001","unstructured":"Cutlip DE, Baim DS, Ho KK, Popma JJ, Lansky AJ, Cohen DJ, Carrozza JP Jr, Chauhan MS, Rodriguez O, Kuntz RE (2001) Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation 103:1967\u20131971","journal-title":"Circulation"},{"key":"1719_CR9","doi-asserted-by":"publisher","first-page":"2126","DOI":"10.1001\/jama.293.17.2126","volume":"293","author":"I Iakovou","year":"2005","unstructured":"Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126\u20132130","journal-title":"JAMA"},{"key":"1719_CR10","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1056\/NEJMoa067722","volume":"356","author":"B Lagerqvist","year":"2007","unstructured":"Lagerqvist B, James SK, Stenestrand U, Lindb\u00e4ck J, Nilsson T, Wallentin L, SCAAR Study Group (2007) Long-term outcomes with drug-eluting stents versus bare metal stents in Sweden. N Engl J Med 356:1009\u20131019","journal-title":"N Engl J Med"},{"key":"1719_CR11","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.1007\/s10554-012-0039-z","volume":"28","author":"BK Kim","year":"2012","unstructured":"Kim BK, Shin DH, Kim JS, Ko YG, Choi D, Jang Y, Hong MK (2012) Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation. Int J Cardiovasc Imaging 28:1887\u20131894","journal-title":"Int J Cardiovasc Imaging"},{"key":"1719_CR12","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.jcin.2009.01.010","volume":"2","author":"P Moore","year":"2009","unstructured":"Moore P, Barlis P, Spiro J, Ghimire G, Roughton M, Di Mario C, Wallis W, Ilsley C, Mitchell A, Mason M, Kharbanda R, Vincent P, Sherwin S, Dalby M (2009) A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. JACC Cardiovasc Interv 2:437\u2013444","journal-title":"JACC Cardiovasc Interv"},{"key":"1719_CR13","doi-asserted-by":"publisher","first-page":"353","DOI":"10.4244\/EIJV7I3A60","volume":"7","author":"M Radu","year":"2011","unstructured":"Radu M, J\u00f8rgensen E, Kelb\u00e6k H, Helqvist S, Skovgaard L, Saunam\u00e4ki K (2011) Optical coherence tomography at follow-up after percutaneous coronary intervention: relationship between procedural dissections, stent strut malapposition and stent healing. EuroIntervention 7:353\u2013361","journal-title":"EuroIntervention"},{"key":"1719_CR14","doi-asserted-by":"publisher","first-page":"86","DOI":"10.4244\/EIJV6I1A13","volume":"6","author":"M Radu","year":"2010","unstructured":"Radu M, J\u00f8rgensen E, Kelbaek H, Helqvist S, Skovgaard L, Saunam\u00e4ki K (2010) Strut apposition after coronary stent implantation visualised with optical coherence tomography. EuroIntervention 6:86\u201393","journal-title":"EuroIntervention"},{"key":"1719_CR15","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.ijcard.2014.02.036","volume":"173","author":"L R\u00e4ber","year":"2014","unstructured":"R\u00e4ber L, Zanchin T, Baumgartner S, Taniwaki M, Kalesan B, Moschovitis A, Garcia-Garcia HM, Justiz J, Pilgrim T, Wenaweser P, Meier B, J\u00fcni P, Windecker S (2014) Differential healing response attributed to culprit lesions of patients with acute coronary syndromes and stable coronary after implantation of drug-eluting stents: an optical coherence tomography study. Int J Cardiol 173:259\u2013267","journal-title":"Int J Cardiol"},{"key":"1719_CR16","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1093\/eurheartj\/ehp433","volume":"31","author":"F Prati","year":"2010","unstructured":"Prati F, Regar E, Mintz G, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW, Expert\u2019s OCT Review Document (2010) Expert review document on methodology, terminology and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J. 31:401\u2013415","journal-title":"Eur Heart J."},{"key":"1719_CR17","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1093\/eurheartj\/ehs095","volume":"33","author":"F Prati","year":"2012","unstructured":"Prati F, Guagliumi G, Mintz GS, Costa M, Regar E, Akasaka T, Barlis P, Tearney GJ, Jang IK, Arbustini E, Bezerra HG, Ozaki Y, Bruining N, Dudek D, Radu M, Erglis A, Motreff P, Alfonso F, Toutouzas K, Gonzalo N, Tamburino C, Adriaenssens T, Pinto F, Serruys PW, Di Mario C, Expert\u2019s OCT Review Document (2012) Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures. Eur Heart J. 33:2513\u20132520","journal-title":"Eur Heart J."},{"key":"1719_CR18","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1093\/eurheartj\/ehv320","volume":"37","author":"M Roffi","year":"2016","unstructured":"Roffi M, Patrono C, Collet J-P, Mueller C, Valgimigli M, Andreotti F, Bax JJ, Borger MA, Brotons C, Chew DP, Gencer B, Hasenfuss G, Kjeldsen K, Lancellotti P, Landmesser U, Mehilli J, Mukherjee D, Storey RF, Windecker S, Baumgartner H, Gaemperli O, Achenbach S, Agewall S, Badimon L, Baigent C, Bueno H, Bugiardini R, Carerj S, Casselman F, Cuisset T, Erol \u00c7, Fitzsimons D, Halle M, Hamm C, Hildick-Smith D, Huber K, Iliodromitis E, James S, Lewis BS, Lip GY, Piepoli MF, Richter D, Rosemann T, Sechtem U, Steg PG, Vrints C, Luis Zamorano J, Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (2016) 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC). Eur Heart J. 37:267\u2013315","journal-title":"Eur Heart J."},{"key":"1719_CR19","doi-asserted-by":"publisher","first-page":"2541","DOI":"10.1093\/eurheartj\/ehu283","volume":"35","author":"S Windecker","year":"2014","unstructured":"Authors\/Task Force members, Windecker S, Kolh P, Alfonso F, Collet JP, Cremer J, Falk V, Filippatos G, Hamm C, Head SJ, J\u00fcni P, Kappetein AP, Kastrati A, Knuuti J, Landmesser U, Laufer G, Neumann FJ, Richter DJ, Schauerte P, Sousa Uva M, Stefanini GG, Taggart DP, Torracca L, Valgimigli M, Wijns W (2014) Witkowski A (2014) ESC\/EACTS Guidelines on myocardial revascularization. The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) Developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J. 35:2541\u20132619","journal-title":"Eur Heart J."},{"key":"1719_CR20","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1007\/s11739-015-1242-4","volume":"10","author":"E Cecchi","year":"2015","unstructured":"Cecchi E, Marcucci R, Chiostri M, MecarocciV Spini V, Innocenti L, Calabretta R, Cordisco A, Romano SM, Abbate R, Gensini GF, Giglioli C (2015) Dual antiplatelet therapy tailored on platelet function test after coronary stent implantation: a real-world experience. Int and Emerg Med 10:805\u2013814","journal-title":"Int and Emerg Med"},{"key":"1719_CR21","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1056\/NEJMoa051175","volume":"353","author":"S Windecker","year":"2005","unstructured":"Windecker S, Remondino A, Eberli FR, J\u00fcni P, R\u00e4ber L, Wenaweser P, Togni M, Billinger M, T\u00fcller D, Seiler C, Roffi M, Corti R, S\u00fctsch G, Maier W, L\u00fcscher T, Hess OM, Egger M, Meier B (2005) Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization. N Engl J Med 353:653\u2013662","journal-title":"N Engl J Med"},{"issue":"8","key":"1719_CR22","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1007\/s00380-019-01360-x","volume":"34","author":"N Oka","year":"2019","unstructured":"Oka N, Fujii K, Kadohira T, Kitahara H, Fujimoto Y, Takahara M, Himi T, Ishikawa K, Sano K, Kobayashi Y (2019) Assessment of strut coverage of everolimus-eluting platinum chromium stent 2\u00a0weeks after implantation by optical coherence tomography. Heart Vessels 34(8):1258\u20131265","journal-title":"Heart Vessels"},{"key":"1719_CR23","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1016\/j.ijcard.2014.08.031","volume":"176","author":"F Prati","year":"2014","unstructured":"Prati F, Romagnoli E, Valgimigli M, Burzotta F, De Benedictis M, Ramondo A, Mehran R, Stella PR (2014) Randomized comparison between 3-month Cre8 DES vs 1-month Vision\/Multilink8 BMS neointimal coverage assessed by OCT evaluation: the demostrate study. Int J Cardiol. 176:904\u2013909","journal-title":"Int J Cardiol."},{"issue":"Suppl. B","key":"1719_CR24","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.jacc.2017.09.599","volume":"70","author":"M Pruski Jr","year":"2017","unstructured":"Pruski M Jr, Blachut A, Kachel M, Michalak M, Janas A, Fernandez C, Buszman P, Milewski K, Buszman P (2017) Determinants of stent healing in optical coherence tomography Validation study with histpathlogy in the porcine coronary restenosis model. JACC 70(Suppl. B):202","journal-title":"JACC"},{"issue":"7","key":"1719_CR25","first-page":"806","volume":"10","author":"J Qian","year":"2014","unstructured":"Qian J, Zhang YJ, Xu B, Yang YJ, Yan HB, Sun ZW, Zhao YL, Tang YD, Gao Z, Chen J, Cui JG, Mintz GS, Gao RL (2014) Optical coherence tomography assessment of a PLGA-polymer with electro-grafting base layer versus a PLA-polymer sirolimus-eluting stent at three-month follow-up: the BuMA-OCT randomised trial. EuroIntervention. 10(7):806\u2013814","journal-title":"EuroIntervention."},{"issue":"5","key":"1719_CR26","doi-asserted-by":"publisher","first-page":"e574","DOI":"10.4244\/EIJV12I5A97","volume":"12","author":"P Suwannasom","year":"2016","unstructured":"Suwannasom P, Onuma Y, Benit E, Gach O, von Birgelen C, Hofma SH, Sotomi Y, Bo X, Zhang YJ, Gao R, Garc\u00eda-Garc\u00eda HM, Wykrzykowska JJ, de Winter RJ, Serruys PW (2016) Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging. EuroIntervention. 12(5):e574\u2013e583","journal-title":"EuroIntervention."},{"issue":"12","key":"1719_CR27","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.4244\/EIJV9I12A236","volume":"9","author":"BK Kim","year":"2014","unstructured":"Kim BK, Ha J, Mintz GS, Kim JS, Shin DH, Ko YG, Choi D, Jang Y, Hong MK (2014) Randomised comparison of strut coverage between Nobori biolimus-eluting and sirolimus-eluting stents: an optical coherence tomography analysis. EuroIntervention. 9(12):1389\u20131397","journal-title":"EuroIntervention."},{"key":"1719_CR28","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.ijcard.2008.11.204","volume":"141","author":"P Barlis","year":"2010","unstructured":"Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, Di Mario C (2010) Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol 141:151\u2013156","journal-title":"Int J Cardiol"},{"key":"1719_CR29","first-page":"128","volume":"3","author":"J Tanigawa","year":"2007","unstructured":"Tanigawa J, Barlis P, Di Mario C (2007) Intravascular optical coherence tomography: optimization of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention. 3:128\u2013136","journal-title":"EuroIntervention."},{"key":"1719_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2019.06.075","author":"SJ Hong","year":"2019","unstructured":"Hong SJ, Park KH, Ahn CM, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2019) Severe acute stent malapposition follow-up: 3-month and 12-month serial quantitative analyses by optical coherence tomography. Int J Cardiol. https:\/\/doi.org\/10.1016\/j.ijcard.2019.06.075","journal-title":"Int J Cardiol."},{"key":"1719_CR31","doi-asserted-by":"crossref","first-page":"e012800","DOI":"10.1161\/JAHA.119.012800","volume":"8","author":"S-Y Lee","year":"2019","unstructured":"Lee S-Y, Im E, Hong SJ, Ahn C-M, Kim J-S, Kim B-K, Ko Y-G, Choi D, Jang Y, Hong M-K (2019) Severe acute stent malapposition after drug-eluting stent implantation: effects on long-term clinical outcomes. J Am Heart Assoc 8:e012800","journal-title":"J Am Heart Assoc"},{"key":"1719_CR32","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1093\/eurheartj\/ehv711","volume":"37","author":"G Souteyrand","year":"2016","unstructured":"Souteyrand G, Amabile N, Mangin L, Chabin X, Meneveau N, Cayla G, Vanzetto G, Barnay P, Trouillet C, Rioufol G, Range G, Teiger E, Delaunay R, Dubreuil O, Lhermusier T, Mulliez A, Levesque S, Belle L, Caussin C, Motreff P (2016) Mechanisms of stent thrombosis analysed by optical coherence tomography: insights from the national PESTO French registry. Eur Heart J 37:1208\u20131216","journal-title":"Eur Heart J"},{"key":"1719_CR33","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1161\/CIRCULATIONAHA.115.019071","volume":"133","author":"M Taniwaki","year":"2016","unstructured":"Taniwaki M, Radu MD, Zaugg S, Amabile N, Garcia-Garcia HM, Yamaji K, Jorgensen E, Kelbaek H, Pilgrim T, Caussin C, Zanchin T, Veugeois A, Abildgaard U, Juni P, Cook S, Koskinas KC, Windecker S, Raber L (2016) Mechanisms of very late drug-eluting stent thrombosis assessed by optical coherence tomography. Circulation 133:650\u2013660","journal-title":"Circulation"},{"key":"1719_CR34","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1161\/CIRCULATIONAHA.117.026788","volume":"136","author":"T Adriaenssens","year":"2017","unstructured":"Adriaenssens T, Joner M, Godschalk TC, Malik N, Alfonso F, Xhepa E, De Cock D, Komukai K, Tada T, Cuesta J, Sirbu V, Feldman LJ, Neumann FJ, Goodall AH, Heestermans T, Buysschaert I, Hlinomaz O, Belmans A, Desmet W, Ten Berg JM, Gershlick AH, Massberg S, Kastrati A, Guagliumi G, Byrne RA (2017) Optical coherence tomography findings in patients with coronary stent thrombosis: a report of the PRESTIGE Consortium. Circulation 136:1007\u20131021","journal-title":"Circulation"},{"key":"1719_CR35","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1186\/s12872-016-0295-2","volume":"16","author":"S Yamamura","year":"2016","unstructured":"Yamamura S, Fujisue K, Tsujita K, Sakamoto K, Miyazaki Y, Kaikita K, Hokimoto S, Ogawa H (2016) Optical coherence tomography visualization of stent deformation with subsequent thrombus adhesion at very early phase after everolimus-eluting stent implantation: a case report. BMC Cardiovasc Disord. 16:116","journal-title":"BMC Cardiovasc Disord."},{"issue":"6","key":"1719_CR36","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.jjcc.2017.04.005","volume":"70","author":"Y Katayama","year":"2017","unstructured":"Katayama Y, Kubo T, Akasaka T, Ino Y, Kimura K, Okura H, Shinke T, Igarashi K, Kadota K, Kozuma K, Tanabe K, Nakagawa Y, Muramatsu T, Morino Y, Kimura T, NEXT investigators (2017) Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT. J Cardiol 70(6):530\u2013536","journal-title":"J Cardiol"},{"key":"1719_CR37","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1016\/j.jcin.2012.05.012","volume":"5","author":"L R\u00e4ber","year":"2012","unstructured":"R\u00e4ber L, Baumgartner S, Garcia-Garcia HM, Kalesan B, Justiz J, Pilgrim T, Moschovitis A, Khattab AA, Buellesfeld L, Wenaweser P, Meier B, Serruys PW, J\u00fcni P, Windecker S (2012) Long-term vascular healing in response to sirolimus- and paclitaxel-eluting stents: an optical coherence tomography study. JACC Cardiovasc Interv. 5:946\u2013957","journal-title":"JACC Cardiovasc Interv."},{"key":"1719_CR38","doi-asserted-by":"publisher","first-page":"113","DOI":"10.4244\/EIJV10I1A18","volume":"10","author":"MD Radu","year":"2014","unstructured":"Radu MD, Pfenniger A, R\u00e4ber L, de Marchi SF, Obrist D, Kelb\u00e6k H, Windecker S, Serruys PW, Vogel R (2014) Flow disturbances in stent-related coronary evaginations: a computational fluid-dynamic simulation study. EuroIntervention. 10:113\u2013123","journal-title":"EuroIntervention."},{"key":"1719_CR39","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1161\/CIRCINTERVENTIONS.113.000931","volume":"7","author":"N Foin","year":"2014","unstructured":"Foin N, Guti\u00e9rrez-Chico JL, Nakatani S, Torii R, Bourantas CV, Sen S, Nijjer S, Petraco R, Kousera C, Ghione M, Onuma Y, Garcia-Garcia HM, Francis DP, Wong P, Di Mario C, Davies JE, Serruys PW (2014) Incomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the management of incomplete stent apposition. Circ Cardiovasc Interv. 7:180\u2013189","journal-title":"Circ Cardiovasc Interv."},{"key":"1719_CR40","doi-asserted-by":"publisher","first-page":"2426","DOI":"10.1161\/CIRCULATIONAHA.106.658237","volume":"115","author":"S Cook","year":"2007","unstructured":"Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426\u20132434","journal-title":"Circulation"},{"key":"1719_CR41","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1093\/eurheartj\/ehr484","volume":"33","author":"S Cook","year":"2012","unstructured":"Cook S, Eshtehardi P, Kalesan B, R\u00e4ber L, Wenaweser P, Togni M, Moschovitis A, Vogel R, Seiler C, Eberli FR, L\u00fcscher T, Meier B, J\u00fcni P, Windecker S (2012) Impact of incomplete stent apposition on long-term clinical outcome after drug-eluting stent implantation. Eur Heart J 33:1334\u20131343","journal-title":"Eur Heart J"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-019-01719-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-019-01719-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-019-01719-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T02:25:15Z","timestamp":1664763915000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-019-01719-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,30]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["1719"],"URL":"https:\/\/doi.org\/10.1007\/s10554-019-01719-1","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"value":"1569-5794","type":"print"},{"value":"1573-0743","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,30]]},"assertion":[{"value":"28 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}