{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:33:49Z","timestamp":1740123229841,"version":"3.37.3"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,7,3]],"date-time":"2020-07-03T00:00:00Z","timestamp":1593734400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,3]],"date-time":"2020-07-03T00:00:00Z","timestamp":1593734400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Ziosoft"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1007\/s10554-020-01928-z","type":"journal-article","created":{"date-parts":[[2020,7,3]],"date-time":"2020-07-03T14:03:34Z","timestamp":1593785014000},"page":"2291-2297","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing"],"prefix":"10.1007","volume":"36","author":[{"given":"Pritha","family":"Subramanyam","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan C.","family":"Legasto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Subhi J.","family":"Al\u2019Aref","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shing Chiu","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8064-8493","authenticated-orcid":false,"given":"Quynh A.","family":"Truong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,7,3]]},"reference":[{"issue":"17","key":"1928_CR1","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","volume":"374","author":"MB Leon","year":"2016","unstructured":"Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG, Investigators P (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374(17):1609\u20131620","journal-title":"N Engl J Med"},{"issue":"18","key":"1928_CR2","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","volume":"380","author":"MJ Mack","year":"2019","unstructured":"Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, Leipsic J, Hahn RT, Blanke P, Williams MR, McCabe JM, Brown DL, Babaliaros V, Goldman S, Szeto WY, Genereux P, Pershad A, Pocock SJ, Alu MC, Webb JG, Smith CR, Investigators P (2019) Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med 380(18):1695\u20131705","journal-title":"N Engl J Med"},{"issue":"18","key":"1928_CR3","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","volume":"366","author":"WM Kodali","year":"2012","unstructured":"Kodali WM, Smith CR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366(18):1686\u20131695","journal-title":"N Engl J Med"},{"issue":"5","key":"1928_CR4","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/j.jacc.2013.04.036","volume":"62","author":"RK Binder","year":"2013","unstructured":"Binder RK, Webb JG, Willson AB, Urena M, Hansson NC, Norgaard BL, Pibarot P, Barbanti M, Larose E, Freeman M, Dumont E, Thompson C, Wheeler M, Moss RR, Yang TH, Pasian S, Hague CJ, Nguyen G, Raju R, Toggweiler S, Min JK, Wood DA, Rodes-Cabau J, Leipsic J (2013) The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. J Am Coll Cardiol 62(5):431\u2013438","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"1928_CR5","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1016\/j.jcmg.2013.11.005","volume":"7","author":"P Blanke","year":"2014","unstructured":"Blanke P, Spira EM, Ionasec R, Meinel FG, Ebersberger U, Scheuering M, Canstein C, Flohr TG, Langer M, Schoepf UJ (2014) Semiautomated quantification of aortic annulus dimensions on cardiac CT for TAVR. JACC Cardiovasc Imaging 7(3):320\u2013322","journal-title":"JACC Cardiovasc Imaging"},{"issue":"6","key":"1928_CR6","doi-asserted-by":"publisher","first-page":"1233","DOI":"10.1007\/s10554-015-0662-6","volume":"31","author":"B Foldyna","year":"2015","unstructured":"Foldyna B, Jungert C, Luecke C, von Aspern K, Boehmer-Lasthaus S, Rueth EM, Grothoff M, Nitzsche S, Gutberlet M, Mohr FW, Lehmkuhl L (2015) CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation. Int J Cardiovasc Imaging 31(6):1233\u20131242","journal-title":"Int J Cardiovasc Imaging"},{"issue":"1","key":"1928_CR7","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jcct.2014.11.003","volume":"9","author":"J Lou","year":"2015","unstructured":"Lou J, Obuchowski NA, Krishnaswamy A, Popovic Z, Flamm SD, Kapadia SR, Svensson LG, Bolen MA, Desai MY, Halliburton SS, Tuzcu EM, Schoenhagen P (2015) Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR\/TAVI): analysis of interchangeability. J Cardiovasc Comput Tomogr 9(1):42\u201349","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"1928_CR8","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.ijcard.2018.07.008","volume":"272","author":"B Baessler","year":"2018","unstructured":"Baessler B, Mauri V, Bunck AC, Pinto Dos Santos D, Friedrichs K, Maintz D, Rudolph T (2018) Software-automated multidetector computed tomography-based prosthesis-sizing in transcatheter aortic valve replacement: inter-vendor comparison and relation to patient outcome. Int J Cardiol 272:267\u2013272","journal-title":"Int J Cardiol"},{"issue":"1","key":"1928_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","volume":"13","author":"P Blanke","year":"2019","unstructured":"Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, Marwan M, Norgaard BL, Piazza N, Schoenhagen P, Leipsic JA (2019) Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr 13(1):1\u201320","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"6","key":"1928_CR10","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1007\/s00059-017-4587-9","volume":"42","author":"HA Hildebrandt","year":"2017","unstructured":"Hildebrandt HA, Mahabadi AA, Totzeck M, Janosi RA, Lind AY, Rassaf T, Kahlert P (2017) Imaging for planning of transcatheter aortic valve implantation. Herz 42(6):554\u2013563","journal-title":"Herz"},{"key":"1928_CR11","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.2019180025)","author":"QA Truong","year":"2019","unstructured":"Truong QA, Legasto AC, Deano RC, Bachman DP, Bhatt D, Al\u2019Aref SJ, Devereux RB, Wong SC, Salemi A, Szymonifka J (2019) Performance of dynamic automated CT annular measurements compared to standard manual measurements for transcatheter aortic valve replacement sizing. Radiol Cardiothorac Imaging. https:\/\/doi.org\/10.1148\/ryct.2019180025)","journal-title":"Radiol Cardiothorac Imaging"},{"key":"1928_CR12","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1186\/1756-0500-6-158","volume":"6","author":"AM Lee","year":"2013","unstructured":"Lee AM, Beaudoin J, Thai WE, Wai B, Hui GC, Sidhu MS, Engel LC, Abbara S, Hoffmann U, Ghoshhajra BB (2013) Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography. BMC Res Notes 6:158","journal-title":"BMC Res Notes"},{"issue":"14","key":"1928_CR13","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1016\/j.jacc.2011.11.045","volume":"59","author":"H Jilaihawi","year":"2012","unstructured":"Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275\u20131286","journal-title":"J Am Coll Cardiol"},{"key":"1928_CR14","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.jacc.2011.12.015","volume":"59","author":"A Willson","year":"2012","unstructured":"Willson A, Webb J, LaBounty T, Achenbach S, Moss R, Wheeler M, Thompson C, Min J, Gurvitch R, Norgard B, Toggweiler S, Binder RK, Hague C, Freeman M, Poulter SH, Poulter R, Wood D, Jonathon L (2012) Three-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am College Cardiol 59:14","journal-title":"J Am College Cardiol"},{"issue":"6","key":"1928_CR15","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.jcct.2012.10.002","volume":"6","author":"AB Willson","year":"2012","unstructured":"Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, Moss RR, Toggweiler S, Binder RK, Munt B, Cheung A, Hague C, Ye J, Leipsic JA (2012) Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr 6(6):406\u2013414","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"24","key":"1928_CR16","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.1136\/heartjnl-2014-305665","volume":"100","author":"S Orwat","year":"2014","unstructured":"Orwat S, Diller GP, Kaleschke G, Kerckhoff G, Kempny A, Radke RM, Buerke B, Burg M, Schulke C, Baumgartner H (2014) Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Heart 100(24):1933\u20131938","journal-title":"Heart"},{"issue":"13","key":"1928_CR17","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1161\/CIRCULATIONAHA.113.002677","volume":"129","author":"E Van Belle","year":"2014","unstructured":"Van Belle E, Susen S et al (2014) ostprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the FRANCE2 Registry. Circulation 129(13):1415\u20131427","journal-title":"Circulation"},{"issue":"23","key":"1928_CR18","doi-asserted-by":"publisher","first-page":"2416","DOI":"10.1016\/j.jcin.2016.08.038","volume":"9","author":"M Alkhouli","year":"2016","unstructured":"Alkhouli M, Sarraf M, Maor E, Sanon S, Cabalka A, Eleid MF, Hagler DJ, Pollak P, Reeder G, Rihal CS (2016) Techniques and outcomes of percutaneous aortic paravalvular leak closure. JACC Cardiovasc Interv 9(23):2416\u20132426","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"1928_CR19","doi-asserted-by":"publisher","first-page":"140","DOI":"10.15420\/icr.2018.20.2","volume":"13","author":"JJ Coughlan","year":"2018","unstructured":"Coughlan JJ, Kiernan T, Mylotte D, Arnous S (2018) Annular rupture during transcatheter aortic valve implantation: predictors, management and outcomes. Interv Cardiol 13(3):140\u2013144","journal-title":"Interv Cardiol"},{"issue":"18","key":"1928_CR20","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1056\/NEJMoa1114705","volume":"366","author":"M Giliard","year":"2012","unstructured":"Giliard M, Lung B et al (2012) Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 366(18):1705\u20131715","journal-title":"N Engl J Med"},{"issue":"18","key":"1928_CR21","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","volume":"366","author":"S Kodali","year":"2012","unstructured":"Kodali S, Williams M, Smith CR, Svensson L, Webb JG, Makkar RR, Fontana GP, Dewey T, Thourani V, Pichard A, Fischbein M, Szeto WY, Lim S, Greason KL, Teirstein PS, Malaisrie SC, Douglass PS, Hahn RT, Whisenant B, Zajarias A, Wang D, Akin J, Anderson WN, Leon MB (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366(18):1686\u20131695","journal-title":"N Engl J Med"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-020-01928-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-020-01928-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-020-01928-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,2]],"date-time":"2021-07-02T23:34:52Z","timestamp":1625268892000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-020-01928-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,3]]},"references-count":21,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["1928"],"URL":"https:\/\/doi.org\/10.1007\/s10554-020-01928-z","relation":{},"ISSN":["1569-5794","1573-0743"],"issn-type":[{"type":"print","value":"1569-5794"},{"type":"electronic","value":"1573-0743"}],"subject":[],"published":{"date-parts":[[2020,7,3]]},"assertion":[{"value":"15 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Dr. Truong received grant support from Ziosoft USA Inc. (formerly Qi Imaging LLC). All other authors have no disclosures.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interests"}}]}}