{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T03:16:07Z","timestamp":1794366967433,"version":"4.9.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T00:00:00Z","timestamp":1656460800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T00:00:00Z","timestamp":1656460800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cardiovascular magnetic resonance (CMR) derived ventricular volumes and function guide clinical decision-making for various cardiac pathologies. We aimed to evaluate the efficiency and clinical applicability of a commercially available artificial intelligence (AI) method for performing biventricular volumetric analysis. Three-hundred CMR studies (100 with normal CMR findings, 50 dilated cardiomyopathy, 50 hypertrophic cardiomyopathy, 50 ischaemic heart disease and 50 congenital or valvular heart disease) were randomly selected from database. Manual biventricular volumetric analysis (CMRtools) results were derived from clinical reports and automated volumetric analyses were performed using short axis volumetry AI function of CircleCVI<jats:sup>42<\/jats:sup> v5.12 software. For 20 studies, a combined method of manually adjusted AI contours was tested and all three methods were timed. Clinicians` confidence in AI method was assessed using an online survey. Although agreement was better for left ventricle than right ventricle, AI analysis results were comparable to manual method. Manual adjustment of AI contours further improved agreement: within subject coefficient of variation decreased from 5.0% to 4.5% for left ventricular ejection fraction (EF) and from 9.9% to 7.1% for right ventricular EF. Twenty manual analyses were performed in 250\u00a0min 12\u00a0s whereas same task took 5\u00a0min 48\u00a0s using AI method. Clinicians were open to adopt AI but concerns about accuracy and validity were raised. The AI method provides clinically valid outcomes and saves significant time. To address concerns raised by survey participants and overcome shortcomings of the automated myocardial segmentation, visual assessment of contours and performing manual corrections where necessary appears to be a practical approach.<\/jats:p>","DOI":"10.1007\/s10554-022-02649-1","type":"journal-article","created":{"date-parts":[[2022,6,29]],"date-time":"2022-06-29T04:03:55Z","timestamp":1656475435000},"page":"2413-2424","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Performance of artificial intelligence for biventricular cardiovascular magnetic resonance volumetric analysis in the clinical setting"],"prefix":"10.1007","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9961-8094","authenticated-orcid":false,"given":"Suzan","family":"Hatipoglu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raad H.","family":"Mohiaddin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Gatehouse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Alpendurada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. John","family":"Baksi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cemil","family":"Izgi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjay K.","family":"Prasad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dudley J.","family":"Pennell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sylvia","family":"Krupickova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,29]]},"reference":[{"issue":"5","key":"2649_CR1","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1002\/jmri.26878","volume":"51","author":"D Sheth","year":"2020","unstructured":"Sheth D, Giger ML (2020) Artificial intelligence in the interpretation of breast cancer on MRI. J Magn Reson Imaging 51(5):1310\u20131324. https:\/\/doi.org\/10.1002\/jmri.26878","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2649_CR2","first-page":"1390","volume":"44","author":"J Mordang","year":"2017","unstructured":"Mordang J, Gubern-Merida A, Bria A, Tortorella F, den Heeten G, Karssemeijer N (2017) Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings. Medical physics (Lancaster) 44(4):1390\u20131401","journal-title":"Medical physics (Lancaster)"},{"issue":"6","key":"2649_CR3","doi-asserted-by":"publisher","first-page":"195","DOI":"10.3389\/fcvm.2019.00195","volume":"21","author":"A de Marvao","year":"2020","unstructured":"de Marvao A, Dawes TJW, O\u2019Regan DP (2020) Artificial intelligence for cardiac imaging-genetics research. Front Cardiovasc Med 21(6):195","journal-title":"Front Cardiovasc Med"},{"issue":"9","key":"2649_CR4","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1038\/s41591-018-0147-y","volume":"24","author":"JJ Titano","year":"2018","unstructured":"Titano JJ, Badgeley M, Schefflein J, Pain M, Su A, Cai M et al (2018) Automated deep-neural-network surveillance of cranial images for acute neurologic events. Nat Med 24(9):1337\u20131341","journal-title":"Nat Med"},{"issue":"5","key":"2649_CR5","doi-asserted-by":"publisher","first-page":"e262","DOI":"10.1016\/S1470-2045(19)30149-4","volume":"20","author":"KY Ngiam","year":"2019","unstructured":"Ngiam KY, Khor IW (2019) Big data and machine learning algorithms for health-care delivery. Lancet Oncol 20(5):e262\u2013e273. https:\/\/doi.org\/10.1016\/S1470-2045(19)30149-4","journal-title":"Lancet Oncol"},{"key":"2649_CR6","unstructured":"Watcher RM.(2016) Making IT Work: Harnessing the Power of Health Information Technology to Improve Care in England. https:\/\/www.gov.uk\/government"},{"issue":"36","key":"2649_CR7","doi-asserted-by":"publisher","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","volume":"42","author":"TA McDonagh","year":"2021","unstructured":"McDonagh TA, Metra M, Adamo M et al (2021) 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J 42(36):3599\u20133726","journal-title":"Eur Heart J"},{"issue":"1","key":"2649_CR8","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1186\/s12968-020-00683-3","volume":"22","author":"N Kawel-Boehm","year":"2020","unstructured":"Kawel-Boehm N, Hetzel SJ, Ambale-Venkatesh B, Captur G, Francois CJ, Jerosch-Herold M, Salerno M, Teague SD, Valsangiacomo-Buechel E, van der Geest RJ, Bluemke DA (2020) Reference ranges (\u201cnormal values\u201d) for cardiovascular magnetic resonance (CMR) in adults and children: 2020 update. J Cardiovasc Magn Reson 22(1):87","journal-title":"J Cardiovasc Magn Reson"},{"issue":"10","key":"2649_CR9","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.119.009214","volume":"12","author":"AN Bhuva","year":"2019","unstructured":"Bhuva AN, Bai W, Lau C, Davies RH, Ye Y, Bulluck H, McAlindon E, Culotta V, Swoboda PP, Captur G, Treibel TA, Augusto JB, Knott KD, Seraphim A, Cole GD, Petersen SE, Edwards NC, Greenwood JP, Bucciarelli-Ducci C, Hughes AD, Rueckert D, Moon JC, Manisty CH (2019) A multicenter, scan-rescan, human and machine learning cmr study to test generalizability and precision in imaging biomarker analysis. Circ Cardiovasc Imaging 12(10):e009214","journal-title":"Circ Cardiovasc Imaging"},{"key":"2649_CR10","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.compbiomed.2019.04.042","volume":"109","author":"Q Tong","year":"2019","unstructured":"Tong Q, Li C, Si W, Liao X, Tong Y, Yuan Z, Heng PA (2019) RIANet: Recurrent interleaved attention network for cardiac MRI segmentation. Comput Biol Med 109:290\u2013302","journal-title":"Comput Biol Med"},{"key":"2649_CR11","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1002\/jmri.25932","volume":"48","author":"LK Tan","year":"2018","unstructured":"Tan LK, McLaughlin RA, Lim E, Abdul Aziz YF, Liew YM (2018) Fully automated segmentation of the left ventricle in cine cardiac MRI using neural network regression. J Magn Reson Imaging 48:140\u2013152","journal-title":"J Magn Reson Imaging"},{"key":"2649_CR12","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s12968-018-0516-1","volume":"21","author":"AS Fahmy","year":"2019","unstructured":"Fahmy AS, El-Rewaidy H, Nezafat M, Nakamori S, Nezafat R (2019) Automated analysis of cardiovascular magnetic resonance myocardial native T1mapping images using fully convolutional neural networks. J Cardiovasc Magn Reson 21:7","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"2649_CR13","first-page":"81","volume":"290","author":"Q Tao","year":"2019","unstructured":"Tao Q, Yan W, Wang Y, Paiman EHM, Shamonin DP, Garg P et al (2019) Deep Learning\u2013based Method for fully automatic quantification of left ventricle function from cine MR images: a multivendor. Multicenter Study Radiol 290(1):81\u201388","journal-title":"Multicenter Study Radiol"},{"issue":"1","key":"2649_CR14","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1186\/s12968-020-00678-0","volume":"22","author":"S Karimi-Bidhendi","year":"2020","unstructured":"Karimi-Bidhendi S, Arafati A, Cheng AL, Wu Y, Kheradvar A, Jafarkhani H (2020) Fully-automated deep-learning segmentation of pediatric cardiovascular magnetic resonance of patients with complex congenital heart diseases. J Cardiovasc Magn Reson 22(1):80","journal-title":"J Cardiovasc Magn Reson"},{"issue":"9","key":"2649_CR15","doi-asserted-by":"publisher","first-page":"1755","DOI":"10.1016\/j.jcmg.2018.09.021","volume":"12","author":"F D\u2019Ascenzi","year":"2019","unstructured":"D\u2019Ascenzi F, Anselmi F, Piu P, Fiorentini C, Carbone SF, Volterrani L et al (2019) Cardiac Magnetic Resonance Normal Reference Values of Biventricular Size and Function in Male Athlete\u2019s Heart. JACC Cardiovasc Imaging 12(9):1755\u20131765","journal-title":"JACC Cardiovasc Imaging"},{"key":"2649_CR16","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1080\/10976640600572889","volume":"8","author":"AM Maceira","year":"2006","unstructured":"Maceira AM, Prasad SK, Khan M, Pennell DJ (2006) Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 8:417\u2013426","journal-title":"J Cardiovasc Magn Reson"},{"key":"2649_CR17","doi-asserted-by":"publisher","first-page":"2879","DOI":"10.1093\/eurheartj\/ehl336","volume":"27","author":"AM Maceira","year":"2006","unstructured":"Maceira AM, Prasad SK, Khan M, Pennell DJ (2006) Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J 27:2879\u20132888","journal-title":"Eur Heart J"},{"issue":"1","key":"2649_CR18","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/1532-429X-15-55","volume":"15","author":"V Klinke","year":"2013","unstructured":"Klinke V, Muzzarelli S, Lauriers N et al (2013) Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria. J Cardiovasc Magn Reson 15(1):55","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"2649_CR19","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","volume":"45","author":"LI Lin","year":"1989","unstructured":"Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45(1):255\u2013268","journal-title":"Biometrics"},{"issue":"1","key":"2649_CR20","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s12968-017-0327-9","volume":"19","author":"SE Petersen","year":"2017","unstructured":"Petersen SE, Aung N, Sanghvi MM, Zemrak F, Fung K, Paiva JM, Francis JM, Khanji MY, Lukaschuk E, Lee AM, Carapella V, Kim YJ, Leeson P, Piechnik SK, Neubauer S (2017) Reference ranges for cardiac structure and function using cardiovascular magnetic resonance (CMR) in Caucasians from the UK Biobank population cohort. J Cardiovasc Magn Reson 19(1):18","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"2649_CR21","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s12968-018-0471-x","volume":"20","author":"W Bai","year":"2018","unstructured":"Bai W, Sinclair M, Tarroni G, Oktay O, Rajchl M, Vaillant G, Lee AM, Aung N, Lukaschuk E, Sanghvi MM, Zemrak F, Fung K, Paiva JM, Carapella V, Kim YJ, Suzuki H, Kainz B, Matthews PM, Petersen SE, Piechnik SK, Neubauer S, Glocker B, Rueckert D (2018) Automated cardiovascular magnetic resonance image analysis with fully convolutional networks. J Cardiovasc Magn Reson 20(1):65","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"2649_CR22","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s12968-019-0532-9","volume":"21","author":"SJ Backhaus","year":"2019","unstructured":"Backhaus SJ, Staab W, Steinmetz M, Ritter CO, Lotz J, Hasenfu\u00df G, Schuster A, Kowallick JT (2019) Fully automated quantification of biventricular volumes and function in cardiovascular magnetic resonance: applicability to clinical routine settings. J Cardiovasc Magn Reson 21(1):24","journal-title":"J Cardiovasc Magn Reson"},{"issue":"5","key":"2649_CR23","first-page":"e35","volume":"143","author":"CM Otto","year":"2021","unstructured":"Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP 3rd, Gentile F, Jneid H, Krieger EV, Mack M, McLeod C, O\u2019Gara PT, Rigolin VH, Sundt TM 3rd, Thompson A, Toly C (2021) 2020 ACC\/AHA guideline for the management of patients with valvular heart disease: executive summary: a report of the American college of cardiology\/American heart association joint committee on clinical practice guidelines. Circulation 143(5):e35\u2013e71","journal-title":"Circulation"},{"issue":"11","key":"2649_CR24","doi-asserted-by":"publisher","first-page":"2514","DOI":"10.1109\/TMI.2018.2837502","volume":"37","author":"O Bernard","year":"2018","unstructured":"Bernard O, Lalande A, Zotti C, Cervenansky F, Yang X, Heng PA, Cetin I, Lekadir K, Camara O, Gonzalez Ballester MA, Sanroma G, Napel S, Petersen S, Tziritas G, Grinias E, Khened M, Kollerathu VA, Krishnamurthi G, Rohe MM, Pennec X, Sermesant M, Isensee F, Jager P, Maier-Hein KH, Full PM, Wolf I, Engelhardt S, Baumgartner CF, Koch LM, Wolterink JM, Isgum I, Jang Y, Hong Y, Patravali J, Jain S, Humbert O, Jodoin PM (2018) Deep learning techniques for automatic MRI cardiac multi-structures segmentation and diagnosis: is the problem solved? IEEE Trans Med Imaging 37(11):2514\u20132525","journal-title":"IEEE Trans Med Imaging"},{"issue":"8","key":"2649_CR25","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2021.816985","volume":"15","author":"E Rauseo","year":"2022","unstructured":"Rauseo E, Omer M, Amir-Khalili A, Sojoudi A, Le TT, Cook SA, Hausenloy DJ, Ang B, Toh DF, Bryant J, Chin CWL, Paiva JM, Fung K, Cooper J, Khanji MY, Aung N, Petersen SE (2022) A systematic quality scoring analysis to assess automated cardiovascular magnetic resonance segmentation algorithms. Front Cardiovasc Med 15(8):816985","journal-title":"Front Cardiovasc Med"},{"key":"2649_CR26","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2020-318667","author":"NG Keenan","year":"2021","unstructured":"Keenan NG, Captur G, McCann GP, Berry C, Myerson SG, Fairbairn T, Hudsmith L, O\u2019Regan DP, Westwood M, Greenwood JP (2021) Regional variation in cardiovascular magnetic resonance service delivery across the UK. Heart. https:\/\/doi.org\/10.1136\/heartjnl-2020-318667","journal-title":"Heart"},{"key":"2649_CR27","unstructured":"Circle cardiovascular imaging (2021), Home page. Available from: https:\/\/www.circlecvi.com\/ [Accessed 16th May 2021]."}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-022-02649-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-022-02649-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-022-02649-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T18:21:12Z","timestamp":1669400472000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-022-02649-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,29]]},"references-count":27,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11]]}},"alternative-id":["2649"],"URL":"https:\/\/doi.org\/10.1007\/s10554-022-02649-1","relation":{},"ISSN":["1875-8312"],"issn-type":[{"value":"1875-8312","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,29]]},"assertion":[{"value":"20 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This was a retrospective analysis of data collected for routine clinical care. The study was registered and approved by the Royal Brompton Hospital Safety and Quality Department (approval number 004426) and individual informed consent was not required in line with UK National Research Ethics Service guidance.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}