{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T18:12:41Z","timestamp":1779127961342,"version":"3.51.4"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,11,2]],"date-time":"2022-11-02T00:00:00Z","timestamp":1667347200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,11,2]],"date-time":"2022-11-02T00:00:00Z","timestamp":1667347200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Abbott Laboratories,United States"},{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["K25HL119608"],"award-info":[{"award-number":["K25HL119608"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["R01HL115828"],"award-info":[{"award-number":["R01HL115828"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Irene D. Pritzker Foundation, United States"},{"name":"General Eletric Medical, United States"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"DOI":"10.1007\/s10554-022-02729-2","type":"journal-article","created":{"date-parts":[[2022,11,2]],"date-time":"2022-11-02T08:03:03Z","timestamp":1667376183000},"page":"307-318","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Impact of assuming a circular orifice on flow error through elliptical regurgitant orifices: computational fluid dynamics and in vitro analysis of proximal flow convergence"],"prefix":"10.1007","volume":"39","author":[{"given":"Jeesoo","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sumeet S.","family":"Mitter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lowie","family":"Van Assche","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyungkyu","family":"Huh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory J.","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex J.","family":"Barker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Markl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James D.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,2]]},"reference":[{"issue":"4","key":"2729_CR1","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1161\/01.CIR.84.4.1481","volume":"84","author":"GS Bargiggia","year":"1991","unstructured":"Bargiggia GS, Tronconi L, Sahn DJ et al (1991) A new method for quantitation of mitral regurgitation based on color flow Doppler imaging of flow convergence proximal to regurgitant orifice. Circulation 84(4):1481\u20131489","journal-title":"Circulation"},{"issue":"7","key":"2729_CR2","first-page":"611","volume":"14","author":"P Lancellotti","year":"2013","unstructured":"Lancellotti P, Tribouilloy C, Hagendorff A et al (2013) Recommendations for the echocardiographic assessment of native valvular regurgitation: an executive summary from the European Association of Cardiovascular Imaging. Eur Heart J 14(7):611\u2013644","journal-title":"Eur Heart J"},{"issue":"2","key":"2729_CR3","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1161\/01.CIR.83.2.594","volume":"83","author":"F Recusani","year":"1991","unstructured":"Recusani F, Bargiggia GS, Yoganathan AP et al (1991) A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study. Circulation 83(2):594\u2013604","journal-title":"Circulation"},{"issue":"1","key":"2729_CR4","doi-asserted-by":"publisher","first-page":"58","DOI":"10.4103\/2543-1463.282191","volume":"4","author":"WA Zoghbi","year":"2020","unstructured":"Zoghbi WA, Adams D, Bonow RO et al (2020) Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Magnetic Resonance. J Indian Acad Echocardiography Cardiovasc Imaging 4(1):58","journal-title":"J Indian Acad Echocardiography Cardiovasc Imaging"},{"issue":"3","key":"2729_CR5","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/0735-1097(94)00434-R","volume":"25","author":"M Enriquez-Sarano","year":"1995","unstructured":"Enriquez-Sarano M, Miller FA, Hayes SN et al (1995) Effective mitral regurgitant orifice area: clinical use and pitfalls of the proximal isovelocity surface area method. J Am Coll Cardiol 25(3):703\u2013709","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"2729_CR6","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1161\/01.RES.70.5.923","volume":"70","author":"L Rodriguez","year":"1992","unstructured":"Rodriguez L, Anconina J, Flachskampf FA et al (1992) Impact of finite orifice size on proximal flow convergence. Implications for Doppler quantification of valvular regurgitation. Circul Res 70(5):923\u2013930","journal-title":"Circul Res"},{"issue":"9","key":"2729_CR7","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1056\/NEJMoa041451","volume":"352","author":"M Enriquez-Sarano","year":"2005","unstructured":"Enriquez-Sarano M, Avierinos J-F, Messika-Zeitoun D et al (2005) Quantitative determinants of the outcome of asymptomatic mitral regurgitation. N Engl J Med 352(9):875\u2013883","journal-title":"N Engl J Med"},{"issue":"2","key":"2729_CR8","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/j.jacc.2004.10.030","volume":"45","author":"F Grigioni","year":"2005","unstructured":"Grigioni F, Detaint D, Avierinos J-F et al (2005) Contribution of ischemic mitral regurgitation to congestive heart failure after myocardial infarction. J Am Coll Cardiol 45(2):260\u2013267","journal-title":"J Am Coll Cardiol"},{"issue":"2","key":"2729_CR9","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.ahj.2007.09.002","volume":"155","author":"Y Matsumura","year":"2008","unstructured":"Matsumura Y, Fukuda S, Tran H et al (2008) Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation. Am Heart J 155(2):231\u2013238","journal-title":"Am Heart J"},{"issue":"5","key":"2729_CR10","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1136\/hrt.2007.119123","volume":"94","author":"J-M Song","year":"2008","unstructured":"Song J-M, Kim M-J, Kim Y-J et al (2008) Three-dimensional characteristics of functional mitral regurgitation in patients with severe left ventricular dysfunction: a real-time three-dimensional colour Doppler echocardiography study. Heart 94(5):590\u2013596","journal-title":"Heart"},{"issue":"8","key":"2729_CR11","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.echo.2012.05.021","volume":"25","author":"JA de Agust\u00edn","year":"2012","unstructured":"de Agust\u00edn JA, Marcos-Alberca P, Fernandez-Golfin C et al (2012) Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr 25(8):815\u2013823","journal-title":"J Am Soc Echocardiogr"},{"issue":"11","key":"2729_CR12","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.1016\/j.amjcard.2005.12.065","volume":"97","author":"K Iwakura","year":"2006","unstructured":"Iwakura K, Ito H, Kawano S et al (2006) Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation. Am J Cardiol 97(11):1630\u20131637","journal-title":"Am J Cardiol"},{"issue":"5","key":"2729_CR13","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1016\/0735-1097(91)90839-2","volume":"17","author":"T Utsunomiya","year":"1991","unstructured":"Utsunomiya T, Ogawa T, Doshi R et al (1991) Doppler color flow \u201cproximal isovelocity surface area\u201d method for estimating volume flow rate: effects of orifice shape and machine factors. J Am Coll Cardiol 17(5):1103\u20131111","journal-title":"J Am Coll Cardiol"},{"issue":"2","key":"2729_CR14","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.jacc.2017.03.011","volume":"70","author":"RA Nishimura","year":"2017","unstructured":"Nishimura RA, Otto CM, Bonow RO et al (2017) 2017 AHA\/ACC focused update of the 2014 AHA\/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines. J Am Coll Cardiol 70(2):252\u2013289","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"2729_CR15","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/S0894-7317(98)70099-9","volume":"11","author":"J Hopmeyer","year":"1998","unstructured":"Hopmeyer J, He S, Thorvig KM et al (1998) Estimation of mitral regurgitation with a hemielliptic curve-fitting algorithm: in vitro experiments with native mitral valves. J Am Soc Echocardiogr 11(4):322\u2013331","journal-title":"J Am Soc Echocardiogr"},{"issue":"5","key":"2729_CR16","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1007\/BF02684225","volume":"24","author":"J Hopmeyer","year":"1996","unstructured":"Hopmeyer J, Whitney E, Papp DA et al (1996) Computational simulations of mitral regurgitation quantification using the flow convergence method: comparison of hemispheric and hemielliptic formulae. Ann Biomed Eng 24(5):561\u2013572","journal-title":"Ann Biomed Eng"},{"issue":"8","key":"2729_CR17","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.echo.2008.02.003","volume":"21","author":"P Kahlert","year":"2008","unstructured":"Kahlert P, Plicht B, Schenk IM et al (2008) Direct assessment of size and shape of noncircular vena contracta area in functional versus organic mitral regurgitation using real-time three-dimensional echocardiography. J Am Soc Echocardiogr 21(8):912\u2013921","journal-title":"J Am Soc Echocardiogr"},{"issue":"11","key":"2729_CR18","first-page":"1245","volume":"2","author":"NA Marsan","year":"2009","unstructured":"Marsan NA, Westenberg JJ, Ypenburg C et al (2009) Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance. JACC: Cardiovasc Imaging 2(11):1245\u20131252","journal-title":"JACC: Cardiovasc Imaging"},{"issue":"7","key":"2729_CR19","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1016\/j.echo.2020.03.008","volume":"33","author":"C Papolla","year":"2020","unstructured":"Papolla C, Adda J, Rique A et al (2020) In vitro quantification of mitral regurgitation of complex geometry by the modified proximal isovelocity surface area method. J Am Soc Echocardiogr 33(7):838\u2013847 e1","journal-title":"J Am Soc Echocardiogr"},{"issue":"4","key":"2729_CR20","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1016\/S0894-7317(14)80444-6","volume":"4","author":"T Utsunomiya","year":"1991","unstructured":"Utsunomiya T, Ogawa T, Tang HA et al (1991) Doppler color flow mapping of the proximal isovelocity surface area: a new method for measuring volume flow rate across a narrowed orifice. J Am Soc Echocardiogr 4(4):338\u2013348","journal-title":"J Am Soc Echocardiogr"},{"issue":"7","key":"2729_CR21","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1016\/j.ultrasmedbio.2017.02.012","volume":"43","author":"M Jamil","year":"2017","unstructured":"Jamil M, Ahmad O, Poh KK et al (2017) Feasibility of ultrasound-based computational fluid dynamics as a mitral valve regurgitation quantification technique: comparison with 2-D and 3-D proximal isovelocity surface area-based methods. Ultrasound Med Biol 43(7):1314\u20131330","journal-title":"Ultrasound Med Biol"},{"issue":"3","key":"2729_CR22","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1213\/ANE.0000000000000409","volume":"120","author":"E Ashikhmina","year":"2015","unstructured":"Ashikhmina E, Shook D, Cobey F et al (2015) Three-dimensional versus two-dimensional echocardiographic assessment of functional mitral regurgitation proximal isovelocity surface area. Anesth Analgesia 120(3):534\u2013542","journal-title":"Anesth Analgesia"},{"issue":"11","key":"2729_CR23","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/j.echo.2021.06.011","volume":"34","author":"T Qin","year":"2021","unstructured":"Qin T, Caballero A, Hahn RT et al (2021) Computational analysis of virtual echocardiographic assessment of functional mitral regurgitation for validation of proximal isovelocity surface area methods. J Am Soc Echocardiogr 34(11):1211\u20131223","journal-title":"J Am Soc Echocardiogr"},{"key":"2729_CR24","unstructured":"Domino SP (2015) Sierra Low Mach Module: Nalu Theory Manual 1.0, SAND2015-3107\u00a0W. Sandia National Laboratories Unclassified Unlimited Release (UUR)"},{"issue":"4","key":"2729_CR25","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1161\/01.CIR.78.4.980","volume":"78","author":"J Thomas","year":"1988","unstructured":"Thomas J, Wilkins G, Choong C et al (1988) Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. Circulation 78(4):980\u2013993","journal-title":"Circulation"},{"issue":"4","key":"2729_CR26","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1016\/S0735-1097(87)80290-5","volume":"10","author":"JD Thomas","year":"1987","unstructured":"Thomas JD, Weyman AE (1987) Doppler mitral pressure half-time: a clinical tool in search of theoretical justification. J Am Coll Cardiol 10(4):923\u2013929","journal-title":"J Am Coll Cardiol"},{"issue":"10","key":"2729_CR27","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1016\/j.echo.2014.07.006","volume":"27","author":"M Aurich","year":"2014","unstructured":"Aurich M, Andr\u00e9 F, Keller M et al (2014) Assessment of left ventricular volumes with echocardiography and cardiac magnetic resonance imaging: real-life evaluation of standard versus new semiautomatic methods. J Am Soc Echocardiogr 27(10):1017\u20131024","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"2729_CR28","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.echo.2011.10.004","volume":"25","author":"P Thavendiranathan","year":"2012","unstructured":"Thavendiranathan P, Liu S, Datta S et al (2012) Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. J Am Soc Echocardiogr 25(1):56\u201365","journal-title":"J Am Soc Echocardiogr"},{"issue":"3","key":"2729_CR29","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1067\/mje.2001.110139","volume":"14","author":"M Pu","year":"2001","unstructured":"Pu M, Prior DL, Fan X et al (2001) Calculation of mitral regurgitant orifice area with use of a simplified proximal convergence method: initial clinical application. J Am Soc Echocardiogr 14(3):180\u2013185","journal-title":"J Am Soc Echocardiogr"},{"issue":"3","key":"2729_CR30","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1161\/01.CIR.88.3.1157","volume":"88","author":"L Rodriguez","year":"1993","unstructured":"Rodriguez L, Thomas JD, Monterroso V et al (1993) Validation of the proximal flow convergence method. Calculation of orifice area in patients with mitral stenosis. Circulation 88(3):1157\u20131165","journal-title":"Circulation"},{"issue":"3","key":"2729_CR31","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/0735-1097(95)00509-9","volume":"27","author":"M Pu","year":"1996","unstructured":"Pu M, Vandervoort PM, Greenberg NL et al (1996) Impact of wall constraint on velocity distribution in proximal flow convergence zone Implications for color Doppler quantification of mitral regurgitation. J Am Coll Cardiol 27(3):706\u2013713","journal-title":"J Am Coll Cardiol"},{"issue":"8","key":"2729_CR32","doi-asserted-by":"publisher","first-page":"2169","DOI":"10.1161\/01.CIR.92.8.2169","volume":"92","author":"M Pu","year":"1995","unstructured":"Pu M, Vandervoort PM, Griffin BP et al (1995) Quantification of mitral regurgitation by the proximal convergence method using transesophageal echocardiography: clinical validation of a geometric correction for proximal flow constraint. Circulation 92(8):2169\u20132177","journal-title":"Circulation"},{"issue":"10","key":"2729_CR33","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1016\/j.amjcard.2006.12.079","volume":"99","author":"SH Little","year":"2007","unstructured":"Little SH, Igo SR, Pirat B et al (2007) In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation. Am J Cardiol 99(10):1440\u20131447","journal-title":"Am J Cardiol"},{"issue":"11","key":"2729_CR34","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1016\/j.echo.2008.09.004","volume":"21","author":"Y Matsumura","year":"2008","unstructured":"Matsumura Y, Saracino G, Sugioka K et al (2008) Determination of regurgitant orifice area with the use of a new three-dimensional flow convergence geometric assumption in functional mitral regurgitation. J Am Soc Echocardiogr 21(11):1251\u20131256","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"2729_CR35","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/0735-1097(95)00428-9","volume":"27","author":"E Schwammenthal","year":"1996","unstructured":"Schwammenthal E, Chen C, Giesler M et al (1996) New method for accurate calculation of regurgitant flow rate based on analysis of doppler color flow maps of the proximal flow field validation in a canine model of mitral regurgitation with initial application in patients. J Am Coll Cardiol 27(1):161\u2013172","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"2729_CR36","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/S0167-5273(00)00222-9","volume":"73","author":"DP Francis","year":"2000","unstructured":"Francis DP, Willson K, Davies LC et al (2000) True shape and area of proximal isovelocity surface area (PISA) when flow convergence is hemispherical in valvular regurgitation. Int J Cardiol 73(3):237\u2013242","journal-title":"Int J Cardiol"},{"issue":"3","key":"2729_CR37","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1161\/01.CIR.95.3.548","volume":"95","author":"JD Thomas","year":"1997","unstructured":"Thomas JD (1997) How leaky is that mitral valve? Simplified Doppler methods to measure regurgitant orifice area. Circulation 95(3):548\u2013550","journal-title":"Circulation"},{"issue":"12","key":"2729_CR38","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/j.echo.2008.09.022","volume":"21","author":"B Plicht","year":"2008","unstructured":"Plicht B, Kahlert P, Goldwasser R et al (2008) Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta. J Am Soc Echocardiogr 21(12):1337\u20131346","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"2729_CR39","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1067\/mje.2003.37","volume":"16","author":"M Sitges","year":"2003","unstructured":"Sitges M, Jones M, Shiota T et al (2003) Real-time three-dimensional color Doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: validation experimental animal study and initial clinical experience. J Am Soc Echocardiogr 16(1):38\u201345","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"2729_CR40","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1161\/CIRCIMAGING.112.980383","volume":"6","author":"P Thavendiranathan","year":"2013","unstructured":"Thavendiranathan P, Liu S, Datta S et al (2013) Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation. Circ Cardiovasc Imaging 6(1):125\u2013133","journal-title":"Circ Cardiovasc Imaging"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-022-02729-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-022-02729-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-022-02729-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T05:33:15Z","timestamp":1674538395000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-022-02729-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,2]]},"references-count":40,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["2729"],"URL":"https:\/\/doi.org\/10.1007\/s10554-022-02729-2","relation":{},"ISSN":["1875-8312"],"issn-type":[{"value":"1875-8312","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,2]]},"assertion":[{"value":"27 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dr. Thomas reports consulting fees from Abbott Vascular, egnite, GE Medical, EchoIQ and Caption Health and spouse employment with Caption Health. Dr. Mitter reports honoraria from Alnylam and the National Minority Quality Forum.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}