{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T03:55:29Z","timestamp":1777521329868,"version":"3.51.4"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T00:00:00Z","timestamp":1699401600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T00:00:00Z","timestamp":1699401600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100005072","name":"Japanese Circulation Society","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005072","id-type":"DOI","asserted-by":"publisher"}]},{"name":"34th research grant from Fukuda Foundation for Medical Technology"},{"name":"JST, CREST"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"DOI":"10.1007\/s10554-023-02997-6","type":"journal-article","created":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T21:20:28Z","timestamp":1699478428000},"page":"385-395","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Development of artificial intelligence-based slow-motion echocardiography and clinical usefulness for evaluating regional wall motion abnormalities"],"prefix":"10.1007","volume":"40","author":[{"given":"Yuki","family":"Sahashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryo","family":"Takeshita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takatomo","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuma","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayako","family":"Sekine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daichi","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Ichiryu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susumu","family":"Endo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Fukuoka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Hara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Okura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,11,8]]},"reference":[{"key":"2997_CR1","doi-asserted-by":"publisher","first-page":"2372","DOI":"10.1016\/j.jacc.2022.11.001","volume":"80","author":"M Lindstrom","year":"2022","unstructured":"Lindstrom M, DeCleene N, Dorsey H et al (2022) Global Burden of Cardiovascular Diseases and risks collaboration (1990\u20132021). J Am Coll Cardiol 80:2372\u20132425","journal-title":"J Am Coll Cardiol"},{"key":"2997_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.echo.2018.06.004","volume":"32","author":"C Mitchell","year":"2019","unstructured":"Mitchell C, Rahko PS, Blauwet LA et al (2019) Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr 32:1\u201364. https:\/\/doi.org\/10.1016\/j.echo.2018.06.004","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR3","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1093\/ehjci\/jeab092","volume":"23","author":"W Woodward","year":"2022","unstructured":"Woodward W, Dockerill C, McCourt A et al (2022) Real-world performance and accuracy of stress echocardiography: the EVAREST observational multi-centre study. Eur Heart J Cardiovasc Imaging 23:689\u2013698. https:\/\/doi.org\/10.1093\/ehjci\/jeab092","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2997_CR4","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1016\/s0735-1097(10)80182-2","volume":"17","author":"E Picano","year":"1991","unstructured":"Picano E, Lattanzi F, Orlandini A, Marini C, L\u2019Abbate A (1991) Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol 17:666\u2013669. https:\/\/doi.org\/10.1016\/s0735-1097(10)80182-2","journal-title":"J Am Coll Cardiol"},{"key":"2997_CR5","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1007\/s12574-021-00531-y","volume":"19","author":"DR Anderson","year":"2021","unstructured":"Anderson DR, Blissett S, O\u2019Sullivan P, Qasim A (2021) Differences in echocardiography interpretation techniques among trainees and expert readers. J Echocardiogr 19:222\u2013231. https:\/\/doi.org\/10.1007\/s12574-021-00531-y","journal-title":"J Echocardiogr"},{"key":"2997_CR6","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1016\/j.echo.2009.07.006","volume":"22","author":"ML Geleijnse","year":"2009","unstructured":"Geleijnse ML, Krenning BJ, van Dalen BM et al (2009) Factors affecting sensitivity and specificity of diagnostic testing: dobutamine stress echocardiography. J Am Soc Echocardiogr 22:1199\u20131208. https:\/\/doi.org\/10.1016\/j.echo.2009.07.006","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR7","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1016\/j.jcmg.2011.06.004","volume":"4","author":"AM Johri","year":"2011","unstructured":"Johri AM, Picard MH, Newell J, Marshall JE, King ME, Hung J (2011) Can a teaching intervention reduce interobserver variability in LVEF assessment: a quality control exercise in the echocardiography lab. JACC Cardiovasc Imaging 4:821\u2013829. https:\/\/doi.org\/10.1016\/j.jcmg.2011.06.004","journal-title":"JACC Cardiovasc Imaging"},{"key":"2997_CR8","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1016\/j.echo.2013.07.017","volume":"26","author":"P Thavendiranathan","year":"2013","unstructured":"Thavendiranathan P, Popovi\u0107 ZB, Flamm SD, Dahiya A, Grimm RA, Marwick TH (2013) Improved interobserver variability and accuracy of echocardiographic visual left ventricular ejection fraction assessment through a self-directed learning program using cardiac magnetic resonance images. J Am Soc Echocardiogr 26:1267\u20131273. https:\/\/doi.org\/10.1016\/j.echo.2013.07.017","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR9","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.ultras.2017.11.013","volume":"84","author":"JK Dave","year":"2018","unstructured":"Dave JK, Mc Donald ME, Mehrotra P, Kohut AR, Eisenbrey JR, Forsberg F (2018) Recent technological advancements in cardiac ultrasound imaging. Ultrasonics 84:329\u2013340. https:\/\/doi.org\/10.1016\/j.ultras.2017.11.013","journal-title":"Ultrasonics"},{"key":"2997_CR10","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1038\/s41586-020-2145-8","volume":"580","author":"D Ouyang","year":"2020","unstructured":"Ouyang D, He B, Ghorbani A et al (2020) Video-based AI for beat-to-beat assessment of cardiac function. Nature 580:252\u2013256. https:\/\/doi.org\/10.1038\/s41586-020-2145-8","journal-title":"Nature"},{"key":"2997_CR11","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1038\/s41586-023-05947-3","volume":"616","author":"B He","year":"2023","unstructured":"He B, Kwan AC, Cho JH et al (2023) Blinded, randomized trial of sonographer versus AI cardiac function assessment. Nature 616:520\u2013524. https:\/\/doi.org\/10.1038\/s41586-023-05947-3","journal-title":"Nature"},{"key":"2997_CR12","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1007\/s10554-023-02802-4","volume":"39","author":"CL Luong","year":"2023","unstructured":"Luong CL, Behnami D, Liao Z et al (2023) Machine learning derived echocardiographic image quality in patients with left ventricular systolic dysfunction: insights on the echo views of greatest image quality. Int J Cardiovasc Imaging 39:1313\u20131321. https:\/\/doi.org\/10.1007\/s10554-023-02802-4","journal-title":"Int J Cardiovasc Imaging"},{"key":"2997_CR13","doi-asserted-by":"publisher","first-page":"e46","DOI":"10.1016\/S2589-7500(21)00235-1","volume":"4","author":"J Tromp","year":"2022","unstructured":"Tromp J, Seekings PJ, Hung CL et al (2022) Automated interpretation of systolic and diastolic function on the echocardiogram: a multicohort study. Lancet Digit Health 4:e46\u2013e54. https:\/\/doi.org\/10.1016\/S2589-7500(21)00235-1","journal-title":"Lancet Digit Health"},{"key":"2997_CR14","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1161\/CIRCULATIONAHA.120.047530","volume":"142","author":"MS Huang","year":"2020","unstructured":"Huang MS, Wang CS, Chiang JH, Liu PY, Tsai WC (2020) Automated recognition of regional wall motion abnormalities through deep neural network interpretation of transthoracic echocardiography. Circulation 142:1510\u20131520. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.120.047530","journal-title":"Circulation"},{"key":"2997_CR15","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1001\/jamacardio.2021.6059","volume":"7","author":"G Duffy","year":"2022","unstructured":"Duffy G, Cheng PP, Yuan N et al (2022) High-throughput precision phenotyping of left ventricular hypertrophy with cardiovascular deep learning. JAMA Cardiol 7:386\u2013395. https:\/\/doi.org\/10.1001\/jamacardio.2021.6059","journal-title":"JAMA Cardiol"},{"key":"2997_CR16","doi-asserted-by":"publisher","first-page":"2726","DOI":"10.1038\/s41467-021-22877-8","volume":"12","author":"S Goto","year":"2021","unstructured":"Goto S, Mahara K, Beussink-Nelson L et al (2021) Artificial intelligence-enabled fully automated detection of cardiac amyloidosis using electrocardiograms and echocardiograms. Nat Commun 12:2726. https:\/\/doi.org\/10.1038\/s41467-021-22877-8","journal-title":"Nat Commun"},{"key":"2997_CR17","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1016\/j.echo.2022.12.014","volume":"36","author":"N Yuan","year":"2023","unstructured":"Yuan N, Kwan AC, Duffy G et al (2023) Prediction of coronary artery calcium using deep learning of echocardiograms. J Am Soc Echocardiogr 36:474\u2013481e3. https:\/\/doi.org\/10.1016\/j.echo.2022.12.014","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR18","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1038\/s41591-021-01614-0","volume":"28","author":"P Rajpurkar","year":"2022","unstructured":"Rajpurkar P, Chen E, Banerjee O, Topol EJ (2022) AI in health and medicine. Nat Med 28:31\u201338. https:\/\/doi.org\/10.1038\/s41591-021-01614-0","journal-title":"Nat Med"},{"key":"2997_CR19","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1016\/j.jcmg.2019.02.024","volume":"13","author":"K Kusunose","year":"2020","unstructured":"Kusunose K, Abe T, Haga A et al (2020) A deep learning approach for assessment of regional wall motion abnormality from echocardiographic images. JACC Cardiovasc Imaging 13:374\u2013381. https:\/\/doi.org\/10.1016\/j.jcmg.2019.02.024","journal-title":"JACC Cardiovasc Imaging"},{"key":"2997_CR20","doi-asserted-by":"publisher","unstructured":"Jiang H, Sun D, Jampani V, Yang M-H, Learned-Miller E, Kautz J (2018) Super slomo: high quality estimation of multiple intermediate frames for video interpolation. In: Proceedings of the IEEE conference on computer vision and pattern recognition, p\u00a09000\u20139008. https:\/\/doi.org\/10.1109\/CVPR.2018.00938","DOI":"10.1109\/CVPR.2018.00938"},{"key":"2997_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.echo.2019.07.001","volume":"33","author":"PA Pellikka","year":"2020","unstructured":"Pellikka PA, Arruda-Olson A, Chaudhry FA et al (2020) Guidelines for performance, interpretation, and application of stress echocardiography in Ischemic Heart Disease: from the American Society of Echocardiography. J Am Soc Echocardiogr 33:1\u201341e8. https:\/\/doi.org\/10.1016\/j.echo.2019.07.001","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR22","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1161\/hc0402.102975","volume":"105","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539\u2013542. https:\/\/doi.org\/10.1161\/hc0402.102975","journal-title":"Circulation"},{"key":"2997_CR23","doi-asserted-by":"publisher","first-page":"2017","DOI":"10.1016\/j.jcmg.2020.07.015","volume":"13","author":"PP SenGupta","year":"2020","unstructured":"SenGupta PP, Shrestha S, Berthon B et al (2020) Proposed requirements for cardiovascular imaging-related machine learning evaluation (PRIME): a checklist: reviewed by the American College of Cardiology healthcare innovation council. JACC Cardiovasc Imaging 13:2017\u20132035. https:\/\/doi.org\/10.1016\/j.jcmg.2020.07.015","journal-title":"JACC Cardiovasc Imaging"},{"key":"2997_CR24","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1136\/bmj.326.7379.41","volume":"326","author":"PM Bossuyt","year":"2003","unstructured":"Bossuyt PM, Reitsma JB, Bruns DE et al (2003) Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. BMJ 326:41\u201344. https:\/\/doi.org\/10.1136\/bmj.326.7379.41","journal-title":"BMJ"},{"key":"2997_CR25","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/s0735-1097(02)02338-0","volume":"40","author":"A Elhendy","year":"2002","unstructured":"Elhendy A, Mahoney DW, Khandheria BK, Paterick TE, Burger KN, Pellikka PA (2002) Prognostic significance of the location of wall motion abnormalities during exercise echocardiography. J Am Coll Cardiol 40:1623\u20131629. https:\/\/doi.org\/10.1016\/s0735-1097(02)02338-0","journal-title":"J Am Coll Cardiol"},{"key":"2997_CR26","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1016\/j.echo.2022.04.005","volume":"35","author":"AS Tseng","year":"2022","unstructured":"Tseng AS, Lopez-Jimenez F, Pellikka PA (2022) Future guidelines for artificial intelligence in echocardiography. J Am Soc Echocardiogr 35:878\u2013882. https:\/\/doi.org\/10.1016\/j.echo.2022.04.005","journal-title":"J Am Soc Echocardiogr"},{"key":"2997_CR27","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1001\/jamacardio.2021.0185","volume":"6","author":"A Narang","year":"2021","unstructured":"Narang A, Bae R, Hong H et al (2021) Utility of a deep-learning algorithm to guide novices to acquire echocardiograms for limited diagnostic use. JAMA Cardiol 6:624\u2013632. https:\/\/doi.org\/10.1001\/jamacardio.2021.0185","journal-title":"JAMA Cardiol"},{"key":"2997_CR28","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/j.jcmg.2022.07.018","volume":"16","author":"EM Hidalgo","year":"2023","unstructured":"Hidalgo EM, Wright L, Isaksson M, Lambert G, Marwick TH (2023) Current applications of robot-assisted ultrasound examination. JACC Cardiovasc Imaging 16:239\u2013247. https:\/\/doi.org\/10.1016\/j.jcmg.2022.07.018","journal-title":"JACC Cardiovasc Imaging"},{"key":"2997_CR29","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.jcmg.2007.10.014","volume":"1","author":"JC Plana","year":"2008","unstructured":"Plana JC, Mikati IA, Dokainish H et al (2008) A randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery Disease the OPTIMIZE Trial. JACC Cardiovasc Imaging 1:145\u2013152. https:\/\/doi.org\/10.1016\/j.jcmg.2007.10.014","journal-title":"JACC Cardiovasc Imaging"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-023-02997-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-023-02997-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-023-02997-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T04:45:36Z","timestamp":1708663536000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-023-02997-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,8]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["2997"],"URL":"https:\/\/doi.org\/10.1007\/s10554-023-02997-6","relation":{},"ISSN":["1875-8312"],"issn-type":[{"value":"1875-8312","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,8]]},"assertion":[{"value":"25 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"We used the services of Editage\u00ae to perform English proofreading on the final manuscript. The proofreading was conducted to ensure the accuracy and clarity of the language used in the manuscript. We did not use any Generative AI services in the writing process. All content in this manuscript was written by the authors and was manually.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Writing support"}}]}}