{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:45:05Z","timestamp":1740185105457,"version":"3.37.3"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002839","name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002839","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>4D-flow MRI is a promising technique for assessing vessel hemodynamics. However, its utilization is currently limited by the lack of reference values, particularly for pulmonary vessels. In this work, we have analysed flow and velocity in the pulmonary trunk (PT), left and right pulmonary arteries (LPA and RPA, respectively) in Landrace pigs at both rest and stress through the software MEVISFlow. Nine healthy Landrace pigs were acutely instrumented closed-chest and transported to the CMR facility for evaluation. After rest measurements, dobutamine was administered to achieve a 25% increase in heart rate compared to rest. 4D-flow MRI images have been analysed through MEVISFlow by two independent observers. Inter- and intra-observer reproducibility was quantified using intraclass correlation coefficient. A significant difference between rest and stress regarding flow and velocity in all the pulmonary vessels was observed. Mean flow increased 55% in PT, 75% in LPA and 40% in RPA. Mean peak velocity increased 55% in PT, 75% in LPA and 66% in RPA. A good-to-excellent reproducibility was observed in rest and stress for flow measurements in all three arteries. An excellent reproducibility for velocity was found in PT at rest and stress, a good one for LPA and RPA at rest, while poor reproducibility was found at stress. The current study showed that pulmonary flow and velocity assessed through 4D-flow MRI follow the physiological alterations during cardiac cycle and after stress induced by dobutamine. A clinical translation to assess pulmonary diseases with 4D-flow MRI under stress conditions needs investigation.<\/jats:p>","DOI":"10.1007\/s10554-024-03132-9","type":"journal-article","created":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T07:02:27Z","timestamp":1717138947000},"page":"1511-1524","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pulmonary 4D-flow MRI imaging in landrace pigs under rest and stress"],"prefix":"10.1007","volume":"40","author":[{"given":"A.","family":"Faragli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"H\u00fcllebrand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. J.","family":"Berendsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L. Tirapu","family":"Sol\u00e0","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. P.","family":"Lo Muzio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"G\u00f6tze","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Tanacli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Doeblin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Stehning","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Schnackenburg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. N.","family":"Van der Vosse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Nagel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Post","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Hennemuth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Alogna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Kelle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,5,31]]},"reference":[{"issue":"3","key":"3132_CR1","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.iccl.2017.03.004","volume":"6","author":"D Silber","year":"2017","unstructured":"Silber D, Lachmann J (2017) Invasive hemodynamics of Pulmonary Disease and the right ventricle. Interventional Cardiol Clin 6(3):329\u2013343","journal-title":"Interventional Cardiol Clin"},{"key":"3132_CR2","doi-asserted-by":"crossref","unstructured":"Topy\u0142a-Putowska W, Tomaszewski M, Wysoki\u0144ski A, Tomaszewski A (2021) Echocardiography in Pulmonary arterial hypertension: comprehensive evaluation and technical considerations. J Clin Med.;10(15)","DOI":"10.3390\/jcm10153229"},{"key":"3132_CR3","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.ijcha.2016.05.011","volume":"12","author":"S Parasuraman","year":"2016","unstructured":"Parasuraman S, Walker S, Loudon BL, Gollop ND, Wilson AM, Lowery C et al (2016) Assessment of pulmonary artery pressure by echocardiography-A comprehensive review. Int J Cardiol Heart Vasculature 12:45\u201351","journal-title":"Int J Cardiol Heart Vasculature"},{"issue":"Suppl 2","key":"3132_CR4","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1097\/00004424-199212002-00006","volume":"27","author":"RR Price","year":"1992","unstructured":"Price RR, Creasy JL, Lorenz CH, Partain CL (1992) Magnetic resonance angiography techniques. Invest Radiol 27(Suppl 2):S27\u201332","journal-title":"Invest Radiol"},{"issue":"5","key":"3132_CR5","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1002\/jmri.21554","volume":"28","author":"A Frydrychowicz","year":"2008","unstructured":"Frydrychowicz A, Bley TA, Zadeh ZA, Harloff A, Winterer JT, Hennig J et al (2008) Image analysis in time-resolved large field of view 3D MR-angiography at 3T. J Magn Reson Imaging: JMRI 28(5):1116\u20131124","journal-title":"J Magn Reson Imaging: JMRI"},{"issue":"5","key":"3132_CR6","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1002\/jmri.20955","volume":"25","author":"SP Lin","year":"2007","unstructured":"Lin SP, Brown JJ (2007) MR contrast agents: physical and pharmacologic basics. J Magn Reson Imaging: JMRI 25(5):884\u2013899","journal-title":"J Magn Reson Imaging: JMRI"},{"issue":"4","key":"3132_CR7","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1002\/jmri.20871","volume":"25","author":"M Markl","year":"2007","unstructured":"Markl M, Harloff A, Bley TA, Zaitsev M, Jung B, Weigang E et al (2007) Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging: JMRI 25(4):824\u2013831","journal-title":"J Magn Reson Imaging: JMRI"},{"issue":"4","key":"3132_CR8","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1081\/JCMR-200065639","volume":"7","author":"P Chai","year":"2005","unstructured":"Chai P, Mohiaddin R (2005) How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping. J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson 7(4):705\u2013716","journal-title":"J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson"},{"issue":"3","key":"3132_CR9","doi-asserted-by":"publisher","first-page":"662","DOI":"10.2214\/AJR.07.3744","volume":"192","author":"MB Srichai","year":"2009","unstructured":"Srichai MB, Lim RP, Wong S, Lee VS (2009) Cardiovascular applications of phase-contrast MRI. AJR Am J Roentgenol 192(3):662\u2013675","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"3132_CR10","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1007\/s00247-010-1932-z","volume":"41","author":"A Hsiao","year":"2011","unstructured":"Hsiao A, Alley MT, Massaband P, Herfkens RJ, Chan FP, Vasanawala SS (2011) Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI. Pediatr Radiol 41(6):711\u2013720","journal-title":"Pediatr Radiol"},{"issue":"2","key":"3132_CR11","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1007\/s10554-015-0779-7","volume":"32","author":"RG Chelu","year":"2016","unstructured":"Chelu RG, van den Bosch AE, van Kranenburg M, Hsiao A, van den Hoven AT, Ouhlous M et al (2016) Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D-flow and echocardiography. Int J Cardiovasc Imaging 32(2):301\u2013307","journal-title":"Int J Cardiovasc Imaging"},{"issue":"10","key":"3132_CR12","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.1016\/j.ejrad.2016.07.018","volume":"85","author":"RG Chelu","year":"2016","unstructured":"Chelu RG, Wanambiro KW, Hsiao A, Swart LE, Voogd T, van den Hoven AT et al (2016) Cloud-processed 4D CMR flow imaging for pulmonary flow quantification. Eur J Radiol 85(10):1849\u20131856","journal-title":"Eur J Radiol"},{"key":"3132_CR13","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/1532-429X-13-55","volume":"13","author":"M Carlsson","year":"2011","unstructured":"Carlsson M, Toger J, Kanski M, Bloch KM, Stahlberg F, Heiberg E et al (2011) Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T. J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson 13:55","journal-title":"J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson"},{"issue":"8","key":"3132_CR14","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.acra.2014.04.012","volume":"21","author":"K Hanneman","year":"2014","unstructured":"Hanneman K, Sivagnanam M, Nguyen ET, Wald R, Greiser A, Crean AM et al (2014) Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging. Acad Radiol 21(8):1002\u20131008","journal-title":"Acad Radiol"},{"issue":"1","key":"3132_CR15","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s12968-023-00921-4","volume":"25","author":"TH Oechtering","year":"2023","unstructured":"Oechtering TH, Nowak A, Sieren MM, Stroth AM, Kirschke N, Wegner F et al (2023) Repeatability and reproducibility of various 4D flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study. J Cardiovasc Magn Reson 25(1):22","journal-title":"J Cardiovasc Magn Reson"},{"issue":"4","key":"3132_CR16","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1007\/s10554-020-01767-y","volume":"36","author":"A Faragli","year":"2020","unstructured":"Faragli A, Tanacli R, Kolp C, Lapinskas T, Stehning C, Schnackenburg B et al (2020) Cardiovascular magnetic resonance feature tracking in pigs: a reproducibility and sample size calculation study. Int J Cardiovasc Imaging 36(4):703\u2013712","journal-title":"Int J Cardiovasc Imaging"},{"issue":"6","key":"3132_CR17","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1007\/s10554-019-01593-x","volume":"35","author":"K Stam","year":"2019","unstructured":"Stam K, Chelu RG, van der Velde N, van Duin R, Wielopolski P, Nieman K et al (2019) Validation of 4D-flow CMR against simultaneous invasive hemodynamic measurements: a swine study. Int J Cardiovasc Imaging 35(6):1111\u20131118","journal-title":"Int J Cardiovasc Imaging"},{"issue":"5","key":"3132_CR18","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1002\/jmri.24681","volume":"41","author":"AL Wentland","year":"2015","unstructured":"Wentland AL, Wieben O, Shanmuganayagam D, Krueger CG, Meudt JJ, Consigny D et al (2015) Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia. J Magn Reson Imaging 41(5):1475\u20131485","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"3132_CR19","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/1532-429X-16-23","volume":"16","author":"A Rold\u00e1n-Alzate","year":"2014","unstructured":"Rold\u00e1n-Alzate A, Frydrychowicz A, Johnson KM, Kellihan H, Chesler NC, Wieben O et al (2014) Non-invasive assessment of cardiac function and pulmonary vascular resistance in an canine model of acute thromboembolic pulmonary hypertension using 4D flow cardiovascular magnetic resonance. J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson 16(1):23","journal-title":"J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson"},{"key":"3132_CR20","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/s12968-015-0174-5","volume":"17","author":"P Dyverfeldt","year":"2015","unstructured":"Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhall CJ, Ebbers T et al (2015) 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson 17:72","journal-title":"J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson"},{"issue":"4","key":"3132_CR21","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1002\/jmri.10272","volume":"17","author":"M Markl","year":"2003","unstructured":"Markl M, Chan FP, Alley MT, Wedding KL, Draney MT, Elkins CJ et al (2003) Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging: JMRI 17(4):499\u2013506","journal-title":"J Magn Reson Imaging: JMRI"},{"key":"3132_CR22","doi-asserted-by":"publisher","unstructured":"Meier S, Hennemuth A, Drexl J, Bock J, Jung B, Preusser T (2013) A fast and noise-robust method for computation of intravascular pressure difference maps from 4D PC-MRI Data. In: Camara, O., Mansi, T., Pop, M., Rhode, K., Sermesant, M., Young, A. (eds) Statistical atlases and computational models of the heart. Imaging and modellingchallenges. STACOM 2012. Lecture notes in computer science, 7746. Springer, Berlin.\u00a0https:\/\/doi.org\/10.1007\/978-3-642-36961-2_25","DOI":"10.1007\/978-3-642-36961-2_25"},{"issue":"1","key":"3132_CR23","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s12968-020-00679-z","volume":"22","author":"A Faragli","year":"2020","unstructured":"Faragli A, Tanacli R, Kolp C, Abawi D, Lapinskas T, Stehning C et al (2020) Cardiovascular magnetic resonance-derived left ventricular mechanics-strain, cardiac power and end-systolic elastance under various inotropic states in swine. J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson 22(1):79","journal-title":"J Cardiovasc Magn Resonance: Official J Soc Cardiovasc Magn Reson"},{"key":"3132_CR24","doi-asserted-by":"publisher","first-page":"689255","DOI":"10.3389\/fcvm.2021.689255","volume":"8","author":"A Faragli","year":"2021","unstructured":"Faragli A, Alogna A, Lee CB, Zhu M, Ghorbani N, Lo Muzio FP et al (2021) Non-invasive CMR-Based quantification of myocardial power and efficiency under stress and ischemic conditions in Landrace Pigs. Front Cardiovasc Med 8:689255","journal-title":"Front Cardiovasc Med"},{"issue":"2","key":"3132_CR25","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.jcmg.2022.08.020","volume":"16","author":"A Alogna","year":"2023","unstructured":"Alogna A, Faragli A, Kolp C, Doeblin P, Tanacli R, Confortola G et al (2023) Blood-oxygen-level dependent (BOLD) T2-Mapping reflects invasively measured central venous Oxygen Saturation in Cardiovascular patients. JACC Cardiovasc Imaging 16(2):251\u2013253","journal-title":"JACC Cardiovasc Imaging"},{"key":"3132_CR26","doi-asserted-by":"crossref","unstructured":"Hennemuth A, Friman O, Schumann C, Bock J, Drexl J, Huellebrand M et al (2011) Fast interactive exploration of 4D MRI flow data. 7964(1):79640E\u2013E","DOI":"10.1117\/12.878202"},{"issue":"1","key":"3132_CR27","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1002\/jmri.20361","volume":"22","author":"J-W Lankhaar","year":"2005","unstructured":"Lankhaar J-W, Hofman MBM, Marcus JT, Zwanenburg JJM, Faes TJC, Vonk-Noordegraaf A (2005) Correction of phase offset errors in main pulmonary artery flow quantification. J Magn Reson Imaging 22(1):73\u201379","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"3132_CR28","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1002\/jmri.22800","volume":"34","author":"M Sigovan","year":"2011","unstructured":"Sigovan M, Hope MD, Dyverfeldt P, Saloner D (2011) Comparison of four-dimensional flow parameters for quantification of flow eccentricity in the ascending aorta. J Magn Reson Imaging 34(5):1226\u20131230","journal-title":"J Magn Reson Imaging"},{"issue":"8476","key":"3132_CR29","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307\u2013310","journal-title":"Lancet"},{"issue":"1","key":"3132_CR30","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1002\/jmri.24362","volume":"40","author":"MD Hope","year":"2014","unstructured":"Hope MD, Sigovan M, Wrenn SJ, Saloner D, Dyverfeldt P (2014) MRI hemodynamic markers of progressive bicuspid aortic valve-related aortic disease. J Magn Reson Imaging 40(1):140\u2013145","journal-title":"J Magn Reson Imaging"},{"issue":"8","key":"3132_CR31","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1093\/ehjci\/jev228","volume":"17","author":"J Garcia","year":"2015","unstructured":"Garcia J, Barker AJ, Murphy I, Jarvis K, Schnell S, Collins JD et al (2015) Four-dimensional flow magnetic resonance imaging-based characterization of aortic morphometry and haemodynamics: impact of age, aortic diameter, and valve morphology. Eur Heart J - Cardiovasc Imaging 17(8):877\u2013884","journal-title":"Eur Heart J - Cardiovasc Imaging"},{"issue":"10","key":"3132_CR32","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/RLI.0000000000000064","volume":"49","author":"NS Burris","year":"2014","unstructured":"Burris NS, Sigovan M, Knauer HA, Tseng EE, Saloner D, Hope MD (2014) Systolic flow displacement correlates with future ascending aortic growth in patients with bicuspid aortic valves undergoing magnetic resonance surveillance. Invest Radiol 49(10):635\u2013639","journal-title":"Invest Radiol"},{"key":"3132_CR33","doi-asserted-by":"crossref","unstructured":"von Knobelsdorff-Brenkenhoff F, Karunaharamoorthy A, Trauzeddel RF, Barker AJ, Blaszczyk E, Markl M et al (2016) Evaluation of Aortic Blood Flow and Wall Shear Stress in Aortic Stenosis and Its Association With Left Ventricular Remodeling. Circulation: Cardiovascular Imaging. ;9(3):e004038","DOI":"10.1161\/CIRCIMAGING.115.004038"},{"key":"3132_CR34","doi-asserted-by":"crossref","unstructured":"Hertel JN, Jerltorp K, Hansen MEH, Isaksen JL, Sattler SM, Linz B et al (2023) 3D-electroanatomical mapping of the left atrium and catheter-based pulmonary vein isolation in pigs: a practical guide. ;10","DOI":"10.3389\/fcvm.2023.1139364"},{"issue":"2","key":"3132_CR35","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1007\/s10554-020-02043-9","volume":"37","author":"R Pewowaruk","year":"2021","unstructured":"Pewowaruk R, Mendrisova K, Larrain C, Francois CJ, Rold\u00e1n-Alzate A, Lamers L (2021) Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography. Int J Cardiovasc Imaging 37(2):743\u2013753","journal-title":"Int J Cardiovasc Imaging"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-024-03132-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-024-03132-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-024-03132-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,18]],"date-time":"2024-07-18T04:08:18Z","timestamp":1721275698000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-024-03132-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,31]]},"references-count":35,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["3132"],"URL":"https:\/\/doi.org\/10.1007\/s10554-024-03132-9","relation":{},"ISSN":["1875-8312"],"issn-type":[{"type":"electronic","value":"1875-8312"}],"subject":[],"published":{"date-parts":[[2024,5,31]]},"assertion":[{"value":"9 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"AH is a member of the management board of Fraunhofer Institute for Digital Medicine MEVIS, Berlin, Germany. The other authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}