{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:45:09Z","timestamp":1740185109016,"version":"3.37.3"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,12,15]],"date-time":"2024-12-15T00:00:00Z","timestamp":1734220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,12,15]],"date-time":"2024-12-15T00:00:00Z","timestamp":1734220800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100013741","name":"Royal Australian and New Zealand College of Radiologists","doi-asserted-by":"publisher","award":["2017\/RANZCR\/002"],"award-info":[{"award-number":["2017\/RANZCR\/002"]}],"id":[{"id":"10.13039\/100013741","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"DOI":"10.1007\/s10554-024-03298-2","type":"journal-article","created":{"date-parts":[[2024,12,15]],"date-time":"2024-12-15T09:49:13Z","timestamp":1734256153000},"page":"211-223","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI"],"prefix":"10.1007","volume":"41","author":[{"given":"Qingdi","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojing","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emma","family":"Hornsey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucy","family":"McKenna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonid","family":"Churilov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Brooks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Matalanis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason","family":"Chuen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Poon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Staeb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Ooi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruth P.","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,12,15]]},"reference":[{"key":"3298_CR1","doi-asserted-by":"publisher","first-page":"2226","DOI":"10.1161\/CIRCULATIONAHA.106.622340","volume":"114","author":"TT Tsai","year":"2006","unstructured":"Tsai TT, Fattori R, Trimarchi S, Isselbacher E, Myrmel T, Evangelista A, Hutchison S, Sechtem U, Cooper JV, Smith DE (2006) Long-term survival in patients presenting with type B acute aortic dissection: insights from the international registry of acute aortic dissection. Circulation 114:2226\u20132231","journal-title":"Circulation"},{"key":"3298_CR2","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1002\/mrm.1910360521","volume":"36","author":"L Wigstr\u00f6m","year":"1996","unstructured":"Wigstr\u00f6m L, Sj\u00f6qvist L, Wranne B (1996) Temporally resolved 3D phase-contrast imaging. Magn Reson Med 36:800\u2013803","journal-title":"Magn Reson Med"},{"key":"3298_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jmr.2012.11.022","volume":"229","author":"LF Gladden","year":"2013","unstructured":"Gladden LF, Sederman A (2013) Recent advances in flow MRI. J Magn Reson 229:2\u201311","journal-title":"J Magn Reson"},{"key":"3298_CR4","doi-asserted-by":"publisher","first-page":"106138","DOI":"10.1016\/j.compbiomed.2022.106138","volume":"150","author":"Q Wang","year":"2022","unstructured":"Wang Q, Guo X, Brooks M, Chuen J, Poon EK, Ooi A, Lim RP (2022) MRI in CFD for chronic type B aortic dissection: ready for prime time? Comput Biol Med 150:106138","journal-title":"Comput Biol Med"},{"key":"3298_CR5","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1016\/j.jvs.2011.11.005","volume":"55","author":"RE Clough","year":"2012","unstructured":"Clough RE, Waltham M, Giese D, Taylor PR, Schaeffter T (2012) A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging. J Vasc Surg 55:914\u2013923","journal-title":"J Vasc Surg"},{"key":"3298_CR6","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3390\/hearts1010004","volume":"1","author":"X Yuan","year":"2020","unstructured":"Yuan X, Clough RE, Nienaber CA (2020) Management of uncomplicated type B aortic dissection. Hearts 1:14\u201324","journal-title":"Hearts"},{"key":"3298_CR7","first-page":"431","volume":"9","author":"RM Quencer","year":"1988","unstructured":"Quencer RM, Hinks RS, Pattany PH, Horen M, Post MJD (1988) Improved MR imaging of the brain by using compensating gradients to suppress motion-induced artifacts. Am J Neuroradiol 9:431\u2013438","journal-title":"Am J Neuroradiol"},{"key":"3298_CR8","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/00004728-199501000-00011","volume":"19","author":"M Hofman","year":"1995","unstructured":"Hofman M, Paschal CB, Li D, Haacke EM, Van Rossum AC, Sprenger M (1995) MRI of coronary arteries: 2D breath-hold vs 3D respiratory-gated acquisition. J Comput Assist Tomogr 19:56\u201362","journal-title":"J Comput Assist Tomogr"},{"key":"3298_CR9","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1148\/radiology.201.3.8939224","volume":"201","author":"JN Oshinski","year":"1996","unstructured":"Oshinski JN, Hofland L, Mukundan S Jr, Dixon WT, Parks WJ, Pettigrew RI (1996) Two-dimensional coronary MR angiography without breath holding. Radiology 201:737\u2013743","journal-title":"Radiology"},{"key":"3298_CR10","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.2214\/ajr.166.6.8633453","volume":"166","author":"JC Post","year":"1996","unstructured":"Post JC, Van Rossum A, Hofman M, Valk J, Visser C (1996) Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. AJR Am J Roentgenol 166:1399\u20131404","journal-title":"AJR Am J Roentgenol"},{"key":"3298_CR11","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1148\/radiology.198.1.8539406","volume":"198","author":"Y Wang","year":"1996","unstructured":"Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55\u201360","journal-title":"Radiology"},{"key":"3298_CR12","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.2214\/ajr.168.5.9129447","volume":"168","author":"M McConnell","year":"1997","unstructured":"McConnell M, Khasgiwala V, Savord B, Chen M, Chuang M, Edelman R, Manning W (1997) Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol 168:1369\u20131375","journal-title":"AJR Am J Roentgenol"},{"key":"3298_CR13","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1002\/jmri.1880070406","volume":"7","author":"MF M\u00fcller","year":"1997","unstructured":"M\u00fcller MF, Fleisch M, Kroeker R, Chatterjee T, Meier B, Vock P (1997) Proximal coronary artery stenosis: three-dimensional MRI with fat saturation and navigator echo. J Magn Reson Imaging 7:644\u2013651","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR14","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1002\/jmri.10106","volume":"15","author":"SM Shea","year":"2002","unstructured":"Shea SM, Deshpande VS, Chung YC, Li D (2002) Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation. J Magn Reson Imaging 15:597\u2013602","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR15","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1002\/mrm.1910370121","volume":"37","author":"MV McConnell","year":"1997","unstructured":"McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Manning WJ, Edelman RR (1997) Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med 37:148\u2013152","journal-title":"Magn Reson Med"},{"key":"3298_CR16","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1002\/(SICI)1522-2586(200002)11:2<208::AID-JMRI20>3.0.CO;2-9","volume":"11","author":"Y Wang","year":"2000","unstructured":"Wang Y, Ehman RL (2000) Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography. J Magn Reson Imaging 11:208\u2013214","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR17","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1002\/mrm.20557","volume":"54","author":"C Stehning","year":"2005","unstructured":"Stehning C, B\u00f6rnert P, Nehrke K, Eggers H, Stuber M (2005) Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 54:476\u2013480","journal-title":"Magn Reson Med"},{"key":"3298_CR18","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1002\/mrm.23247","volume":"68","author":"D Piccini","year":"2012","unstructured":"Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO (2012) Respiratory self-navigation for whole-heart bright-blood coronary MRI: methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med 68:571\u2013579","journal-title":"Magn Reson Med"},{"key":"3298_CR19","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1002\/jmri.23632","volume":"36","author":"M Markl","year":"2012","unstructured":"Markl M, Frydrychowicz A, Kozerke S, Hope M, Wieben O (2012) 4D flow MRI. J Magn Reson Imaging 36:1015\u20131036","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR20","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1016\/j.jacc.2010.01.071","volume":"56","author":"S Kato","year":"2010","unstructured":"Kato S, Kitagawa K, Ishida N, Ishida M, Nagata M, Ichikawa Y, Katahira K, Matsumoto Y, Seo K, Ochiai R (2010) Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial. J Am Coll Cardiol 56:983\u2013991","journal-title":"J Am Coll Cardiol"},{"key":"3298_CR21","doi-asserted-by":"publisher","first-page":"3675","DOI":"10.1002\/mrm.27684","volume":"81","author":"LE Ma","year":"2019","unstructured":"Ma LE, Markl M, Chow K, Huh H, Forman C, Vali A, Greiser A, Carr J, Schnell S, Barker AJ (2019) Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction. Magn Reson Med 81:3675\u20133690","journal-title":"Magn Reson Med"},{"key":"3298_CR22","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202\u20131210","journal-title":"Magn Reson Med"},{"key":"3298_CR23","first-page":"1434","volume":"21","author":"AF Stalder","year":"2013","unstructured":"Stalder AF, Gulsun MA, Greiser A, Jolly MP (2013) Fully automatic visualization of 4D flow data. InProc Intl Soc Mag Reson Med 21:1434","journal-title":"InProc Intl Soc Mag Reson Med"},{"key":"3298_CR24","unstructured":"Wang Q, Guo X, Hornsey E, McKenna L, Churilov L, Brooks M, Matalanis G, Chuen J, Poon E, Staeb D (2020) Respiratory-Controlled Adaptive 4D Flow of the Aorta: Reproducibility and Comparison to 2D Phase Contrast Imaging. Proceedings of the 28th Annual Meeting of the International Society for Magnetic Resonance in Medicine."},{"key":"3298_CR25","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174","journal-title":"Biometrics"},{"key":"3298_CR26","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1111\/j.1440-1681.2010.05376.x","volume":"37","author":"J Ludbrook","year":"2010","unstructured":"Ludbrook J (2010) Linear regression analysis for comparing two measurers or methods of measurement: but which regression? Clin Exp Pharmacol Physiol 37:692\u2013699","journal-title":"Clin Exp Pharmacol Physiol"},{"key":"3298_CR27","first-page":"195","volume":"79","author":"E Bollache","year":"2018","unstructured":"Bollache E, Barker AJ, Dolan RS, Carr JC, van Ooij P, Ahmadian R, Powell A, Collins JD, Geiger J, Markl M (2018) k-t accelerated aortic 4D flow MRI in under two minutes: feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements. Am J Neuroradiol 79:195\u2013207","journal-title":"Am J Neuroradiol"},{"key":"3298_CR28","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0173046","volume":"12","author":"JD Parikh","year":"2017","unstructured":"Parikh JD, Kakarla J, Keavney B, O\u2019Sullivan JJ, Ford GA, Blamire AM, Hollingsworth KG, Coats L (2017) 4D flow MRI assessment of right atrial flow patterns in the normal heart\u2013influence of caval vein arrangement and implications for the patent foramen ovale. PLoS ONE 12:e0173046","journal-title":"PLoS ONE"},{"key":"3298_CR29","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1002\/jmri.24959","volume":"43","author":"P van Ooij","year":"2016","unstructured":"van Ooij P, Powell AL, Potters WV, Carr JC, Markl M, Barker AJ (2016) Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta. J Magn Reson Imaging 43:236\u2013248","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12968-015-0174-5","volume":"17","author":"P Dyverfeldt","year":"2015","unstructured":"Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlh\u00e4ll CJ, Ebbers T, Francios CJ, Frydrychowicz A, Geiger J, Giese D (2015) 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 17:1\u201319","journal-title":"J Cardiovasc Magn Reson"},{"key":"3298_CR31","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1002\/mrm.24885","volume":"72","author":"R Lorenz","year":"2014","unstructured":"Lorenz R, Bock J, Snyder J, Korvink JG, Jung BA, Markl M (2014) Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data. Magn Reson Med 72:33\u201340","journal-title":"Magn Reson Med"},{"key":"3298_CR32","doi-asserted-by":"publisher","first-page":"88","DOI":"10.21873\/invivo.13057","volume":"37","author":"S Hautanen","year":"2023","unstructured":"Hautanen S, Kiljander T, Korpela T, Saari P, Kokkonen J, Mustonen P, Sillanm\u00e4ki S, Yl\u00e4-Herttuala E, Husso M, Hedman M (2023) 4D flow versus 2D phase contrast MRI in populations with Bi-and tricuspid aortic valves. In Vivo 37:88\u201398","journal-title":"In Vivo"},{"key":"3298_CR33","doi-asserted-by":"publisher","DOI":"10.1136\/openhrt-2019-001158","volume":"7","author":"A Alvarez","year":"2020","unstructured":"Alvarez A, Martinez V, Pizarro G, Recio M, Cabrera J\u00c1 (2020) Clinical use of 4D flow MRI for quantification of aortic regurgitation. Open Heart 7:e001158","journal-title":"Open Heart"},{"key":"3298_CR34","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1002\/jmri.26847","volume":"51","author":"BP Adriaans","year":"2020","unstructured":"Adriaans BP, Westenberg JJ, van Cauteren YJ, Gerretsen S, Elbaz MS, Bekkers SC, Veenstra LF, Crijns HJ, Wildberger JE, Schalla S (2020) Clinical assessment of aortic valve stenosis: comparison between 4D flow MRI and transthoracic echocardiography. J Magn Reson Imaging 51:472\u2013480","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-45196-x","volume":"9","author":"S Ebel","year":"2019","unstructured":"Ebel S, Dufke J, K\u00f6hler B, Preim B, Rosemeier S, Jung B, D\u00e4hnert I, Lurz P, Borger M, Grothoff M (2019) Comparison of two accelerated 4D-flow sequences for aortic flow quantification. Sci Rep 9:1\u201310","journal-title":"Sci Rep"},{"key":"3298_CR36","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1007\/s10554-016-0938-5","volume":"32","author":"E Bollache","year":"2016","unstructured":"Bollache E, van Ooij P, Powell A, Carr J, Markl M, Barker AJ (2016) Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics. Int J Cardiovasc Imaging 32:1529\u20131541","journal-title":"Int J Cardiovasc Imaging"},{"key":"3298_CR37","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1002\/jmri.24814","volume":"42","author":"A Zaman","year":"2015","unstructured":"Zaman A, Motwani M, Oliver JJ, Crelier G, Dobson LE, Higgins DM, Plein S, Greenwood JP (2015) 3.0 T, time-resolved, 3D flow-sensitive MR in the thoracic aorta: impact of k-t BLAST acceleration using 8-versus 32-channel coil arrays. J Magn Reson Imaging 42:495\u2013504","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR38","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.acra.2014.04.012","volume":"21","author":"K Hanneman","year":"2014","unstructured":"Hanneman K, Sivagnanam M, Nguyen ET, Wald R, Greiser A, Crean AM, Ley S, Wintersperger BJ (2014) Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging. Acad Radiol 21:1002\u20131008","journal-title":"Acad Radiol"},{"key":"3298_CR39","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/j.acra.2012.12.019","volume":"20","author":"AL Wentland","year":"2013","unstructured":"Wentland AL, Grist TM, Wieben O (2013) Repeatability and internal consistency of abdominal 2D and 4D phase contrast MR flow measurements. Acad Radiol 20:699\u2013704","journal-title":"Acad Radiol"},{"key":"3298_CR40","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1002\/jmri.23793","volume":"37","author":"S Nordmeyer","year":"2013","unstructured":"Nordmeyer S, Riesenkampff E, Messroghli D, Kropf S, Nordmeyer J, Berger F, Kuehne T (2013) Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow. J Magn Reson Imaging 37:208\u2013216","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR41","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1097\/RLI.0b013e31829a4f2f","volume":"48","author":"A Frydrychowicz","year":"2013","unstructured":"Frydrychowicz A, Wieben O, Niespodzany E, Reeder SB, Johnson KM, Fran\u00e7ois CJ (2013) Quantification of thoracic blood flow using volumetric MRI with radial velocity encoding. In Vivo Validation. Invest Radiol. 48:819\u2013825","journal-title":"In Vivo Validation. Invest Radiol."},{"key":"3298_CR42","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1007\/s00247-010-1932-z","volume":"41","author":"A Hsiao","year":"2011","unstructured":"Hsiao A, Alley MT, Massaband P, Herfkens RJ, Chan FP, Vasanawala SS (2011) Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI. Pediatr Radiol 41:711\u2013720","journal-title":"Pediatr Radiol"},{"key":"3298_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1532-429X-13-55","volume":"13","author":"M Carlsson","year":"2011","unstructured":"Carlsson M, T\u00f6ger J, Kanski M, Bloch KM, St\u00e5hlberg F, Heiberg E, Arheden H (2011) Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or kt BLAST: head to head comparison and validation at 1.5 T and 3 T. J Cardiovasc Magn Reson 13:1\u20137","journal-title":"J Cardiovasc Magn Reson"},{"key":"3298_CR44","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1002\/jmri.22280","volume":"32","author":"S Nordmeyer","year":"2010","unstructured":"Nordmeyer S, Riesenkampff E, Crelier G, Khasheei A, Schnackenburg B, Berger F, Kuehne T (2010) Flow-sensitive four-dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study. J Magn Reson Imaging 32:677\u2013683","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR45","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1002\/jmri.22083","volume":"31","author":"MD Hope","year":"2010","unstructured":"Hope MD, Meadows AK, Hope TA, Ordovas KG, Saloner D, Reddy GP, Alley MT, Higgins CB (2010) Clinical evaluation of aortic coarctation with 4D flow MR imaging. J Magn Reson Imaging 31:711\u2013718","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR46","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1148\/radiographics.22.3.g02ma11651","volume":"22","author":"J Lotz","year":"2002","unstructured":"Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 22:651\u2013671","journal-title":"Radiographics"},{"key":"3298_CR47","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1007\/s00247-014-3246-z","volume":"45","author":"M Gabbour","year":"2015","unstructured":"Gabbour M, Schnell S, Jarvis K, Robinson JD, Markl M, Rigsby CK (2015) 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and doppler echocardiography. Pediatr Radiol 45:804\u2013813","journal-title":"Pediatr Radiol"},{"key":"3298_CR48","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.ccl.2017.03.007","volume":"35","author":"DB Alfson","year":"2017","unstructured":"Alfson DB, Ham SW (2017) Type B aortic dissections: current guidelines for treatment. Cardiol Clin 35:387\u2013410","journal-title":"Cardiol Clin"},{"key":"3298_CR49","doi-asserted-by":"publisher","first-page":"905718","DOI":"10.3389\/fcvm.2022.905718","volume":"9","author":"S Chu","year":"2022","unstructured":"Chu S, Kilinc O, Pradella M, Weiss E, Baraboo J, Maroun A, Jarvis K, Mehta CK, Malaisrie SC, Hoel AW (2022) Baseline 4D flow-derived in vivo hemodynamic parameters stratify descending aortic dissection patients with enlarging aortas. Front Cardiovasc Med. 9:905718","journal-title":"Front Cardiovasc Med."},{"issue":"464\u2013474","key":"3298_CR50","volume":"57","author":"PA Rudenick","year":"2013","unstructured":"Rudenick PA, Bijnens BH, Garc\u00eda-Dorado D, Evangelista A (2013) An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B aortic dissections. J Vasc Surg 57(464\u2013474):e465","journal-title":"J Vasc Surg"},{"key":"3298_CR51","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1053\/euhj.2001.2782","volume":"22","author":"R Erbel","year":"2001","unstructured":"Erbel R, Alfonso F, Boileau C, Dirsch O, Eber B, Haverich A, Rakowski H, Struyven J, Radegran K, Sechtem U (2001) Diagnosis and management of aortic dissection: task force on aortic dissection, European society of cardiology. Eur Heart J 22:1642\u20131681","journal-title":"Eur Heart J"},{"key":"3298_CR52","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheatfluidflow.2022.108986","volume":"96","author":"Q Wang","year":"2022","unstructured":"Wang Q, Guo X, St\u00e4b D, Jin N, Poon EK, Lim RP, Ooi A (2022) Computational fluid dynamic simulations informed by CT and 4D flow MRI for post-surgery aortic dissection\u2013A case study. Int J Heat Fluid Flow 96:108986","journal-title":"Int J Heat Fluid Flow"},{"key":"3298_CR53","doi-asserted-by":"crossref","unstructured":"Wang Q, Guo X, Poon EK, Ooi A, Lim RP (2020) Three-dimensional CFD Simulation of Blood Flow in Aortic Dissection.","DOI":"10.14264\/5d0bea7"},{"key":"3298_CR54","unstructured":"Wang Q, Guo X, Hornsey E, McKenna L, St\u00e4b D, Jin N, Poon EK, Lim RP, Ooi A (2022) Constant and pulsatile flow computational fluid dynamics simulations in aortic dissection. \ud55c\uad6d\uc804\uc0b0\uc720\uccb4\uacf5\ud559\ud68c \ud559\uc220\ub300\ud68c\ub17c\ubb38\uc9d1 195\u2013195."},{"key":"3298_CR55","first-page":"1399","volume":"4","author":"J Urmeneta Ulloa","year":"2022","unstructured":"Urmeneta Ulloa J, Mart\u00ednez de Vega V, \u00c1lvarez V\u00e1zquez A, Rivas Oyarzabal J, Forteza Gil A, Cabrera J\u00c1 (2022) 4D-flow cardiac magnetic resonance imaging in chronic aortic dissection assessment: a powerful qualiquantitative diagnostic tool. Case Reports 4:1399\u20131403","journal-title":"Case Reports"},{"key":"3298_CR56","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1002\/jmri.25595","volume":"46","author":"S Schnell","year":"2017","unstructured":"Schnell S, Ansari SA, Wu C, Garcia J, Murphy IG, Rahman OA, Rahsepar AA, Aristova M, Collins JD, Carr JC (2017) Accelerated dual-venc 4D flow MRI for neurovascular applications. J Magn Reson Imaging 46:102\u2013114","journal-title":"J Magn Reson Imaging"},{"key":"3298_CR57","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1002\/mrm.26381","volume":"78","author":"F Contijoch","year":"2017","unstructured":"Contijoch F, Iyer SK, Pilla JJ, Yushkevich P, Gorman JH 3rd, Gorman RC, Litt H, Han Y, Witschey WR (2017) Self-gated MRI of multiple beat morphologies in the presence of arrhythmias. Magn Reson Med 78:678\u2013688","journal-title":"Magn Reson Med"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-024-03298-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-024-03298-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-024-03298-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,10]],"date-time":"2025-02-10T14:31:19Z","timestamp":1739197879000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-024-03298-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,15]]},"references-count":57,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["3298"],"URL":"https:\/\/doi.org\/10.1007\/s10554-024-03298-2","relation":{},"ISSN":["1875-8312"],"issn-type":[{"type":"electronic","value":"1875-8312"}],"subject":[],"published":{"date-parts":[[2024,12,15]]},"assertion":[{"value":"30 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"DS and NJ are employees and shareholders of Siemens Healthcare. Non-employee authors had control of study design and data collection.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}},{"value":"This study was a prospective study with institutional ethics approval.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from all the subjects.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors affirm that human research participants provided informed consent for publication of the images in Figs.\u00a0,  and .","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}