{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T11:14:37Z","timestamp":1788088477453,"version":"build-2803163510"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T00:00:00Z","timestamp":1788048000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T00:00:00Z","timestamp":1788048000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006447","name":"University of Zurich","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006447","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Cardiovasc Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The purpose of this study was to evaluate whether a misalignment correction algorithm reduces artifacts from breathing in patients undergoing computed tomography angiography (CTA) early after coronary artery bypass graft (CABG) surgery. In this retrospective study, consecutive patients undergoing CTA early after CABG surgery between November 2023 and March 2025 were screened. Patients exhibiting relevant breathing artifacts on standard reconstructions were included for the evaluation. CTA was acquired in the ECG-gated sequential mode on a dual-source CT. For each patient, standard reconstructions were compared with those using a misalignment correction algorithm designed to resolve discontinuities between adjacent image stacks (ZeeFree). Two blinded readers assessed artifacts across six anatomical regions (bypass grafts, coronary arteries, thoracic aorta, pulmonary trunk, lung\/trachea, and sternum) using a 4-point visual analogue scale. Among 680 patients scanned at a median of 4 days (IQR 2\u20138 days) after CABG surgery, 75 patients (11%, mean age, 67.7\u2009\u00b1\u20098.4 years, 12 females, 63 males) with a total of 205 bypass grafts presented relevant breathing artifacts in CTA and were included. Median duration of CTA acquisition was 6.9\u00a0s (IQR 5.5\u20139.5\u00a0s). Inter-reader agreement of image quality was substantial to almost perfect across all anatomical structures (weighted kappa: 0.796\u20130.971,\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). The misalignment correction algorithm significantly reduced artifact severity across all anatomical regions for both readers compared to standard reconstructions (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001 for all, overall median artifact score for standard reconstruction: 2 [IQR 1\u20133] vs. ZeeFree reconstruction: 1 [IQR 1\u20131]). Breathing-induced artifacts in CTA of patients undergoing imaging early after CABG surgery occurs frequently and can be significantly reduced using a novel misalignment correction algorithm.\n                  <\/jats:p>","DOI":"10.1007\/s10554-026-03816-4","type":"journal-article","created":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T11:06:11Z","timestamp":1788087971000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Improving image quality by reducing breathing artifacts in CT of patients early after coronary artery bypass graft surgery"],"prefix":"10.1007","author":[{"given":"Elizabet","family":"Nikolova","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tristan T.","family":"Demmert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas Jacob","family":"Moser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Zedler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Koechlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stak","family":"Dushaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e9ctor","family":"Rodriguez Cetina Biefer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omer","family":"Dzemali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Mergen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Eberhard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2581-2166","authenticated-orcid":false,"given":"Hatem","family":"Alkadhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,30]]},"reference":[{"key":"3816_CR1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.06.0736","author":"J Mueller","year":"2007","unstructured":"Mueller J, Jeudy J, Poston R, White CS (2007) Cardiac CT angiography after coronary bypass surgery: prevalence of incidental findings. AJR Am J Roentgenol. https:\/\/doi.org\/10.2214\/AJR.06.0736","journal-title":"AJR Am J Roentgenol"},{"key":"3816_CR2","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezab390","author":"M K\u00e1rolyi","year":"2022","unstructured":"K\u00e1rolyi M et al (2022) Routine early postoperative computed tomography angiography after coronary artery bypass surgery: clinical value and management implications. Eur J Cardiothorac Surg. https:\/\/doi.org\/10.1093\/ejcts\/ezab390","journal-title":"Eur J Cardiothorac Surg"},{"key":"3816_CR3","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezz112","author":"A Zientara","year":"2019","unstructured":"Zientara A et al (2019) Early silent graft failure in off-pump coronary artery bypass grafting: a computed tomography analysis\u2020. Eur J Cardiothorac Surg. https:\/\/doi.org\/10.1093\/ejcts\/ezz112","journal-title":"Eur J Cardiothorac Surg"},{"key":"3816_CR4","doi-asserted-by":"publisher","DOI":"10.21037\/qims-24-1253","author":"H Ma","year":"2025","unstructured":"Ma H, Chen C, Ge Y, Yang C, Mei J, Zhou D (2025) Effect of a breathing exercise program on coronary artery motion artifacts in 256 rows of coronary computed tomography angiography in patients with different heart rate variability. Quant Imaging Med Surg. https:\/\/doi.org\/10.21037\/qims-24-1253","journal-title":"Quant Imaging Med Surg"},{"key":"3816_CR5","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2473071132","author":"M Hamon","year":"2008","unstructured":"Hamon M et al (2008) Diagnostic performance of 16- and 64-section spiral CT for coronary artery bypass graft assessment: meta-analysis. Radiology. https:\/\/doi.org\/10.1148\/radiol.2473071132","journal-title":"Radiology"},{"key":"3816_CR6","doi-asserted-by":"publisher","DOI":"10.1007\/s11936-021-00922-5","author":"GR Small","year":"2021","unstructured":"Small GR, Chow BJW (2021) Imaging in CABG patients. Curr Treat Options Cardiovasc Med. https:\/\/doi.org\/10.1007\/s11936-021-00922-5","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"3816_CR7","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000233","author":"K Higashigaito","year":"2016","unstructured":"Higashigaito K et al (2016) Computed tomography angiography of coronary artery bypass grafts: low contrast media volume protocols adapted to tube voltage. Invest Radiol. https:\/\/doi.org\/10.1097\/RLI.0000000000000233","journal-title":"Invest Radiol"},{"key":"3816_CR8","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000001066","author":"LJ Moser","year":"2024","unstructured":"Moser LJ, Mergen V, Allmendinger T, Manka R, Eberhard M, Alkadhi H (2024) A novel reconstruction technique to reduce stair-step artifacts in sequential mode coronary CT angiography. Invest Radiol. https:\/\/doi.org\/10.1097\/RLI.0000000000001066","journal-title":"Invest Radiol"},{"key":"3816_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-025-11429-z","author":"NP Haag","year":"2025","unstructured":"Haag NP et al (2025) Improving image quality and diagnostic usability in photon-counting coronary CT angiography using a novel reconstruction algorithm. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-025-11429-z","journal-title":"Eur Radiol"},{"key":"3816_CR10","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.19.21456","author":"T Takayanagi","year":"2019","unstructured":"Takayanagi T et al (2019) Comparison of motion artifacts on CT images obtained in the ultrafast scan mode and conventional scan mode for unconscious patients in the emergency department. AJR Am J Roentgenol. https:\/\/doi.org\/10.2214\/AJR.19.21456","journal-title":"AJR Am J Roentgenol"},{"key":"3816_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-012-0110-9","author":"J-F Paul","year":"2012","unstructured":"Paul J-F, Amato A, Rohnean A (2012) Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine. Int J Cardiovasc Imaging. https:\/\/doi.org\/10.1007\/s10554-012-0110-9","journal-title":"Int J Cardiovasc Imaging"},{"key":"3816_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-025-03555-y","author":"EE Vargas","year":"2025","unstructured":"Vargas EE et al (2025) Optimizing coronary CT angiography with spectral dual-layer CT: motion-compensated virtual monoenergetic imaging achieves 50% contrast dose reduction in a phantom study. Int J Cardiovasc Imaging. https:\/\/doi.org\/10.1007\/s10554-025-03555-y","journal-title":"Int J Cardiovasc Imaging"},{"key":"3816_CR13","doi-asserted-by":"publisher","DOI":"10.5152\/dir.2021.19473","author":"Jin L et al","year":"2021","unstructured":"Jin L et al (2021) Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners. Diagn Interv Radiol. https:\/\/doi.org\/10.5152\/dir.2021.19473","journal-title":"Diagn Interv Radiol"},{"key":"3816_CR14","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2016160079","author":"K Kalisz","year":"2016","unstructured":"Kalisz K, Buethe J, Saboo SS, Abbara S, Halliburton S, Rajiah P (2016) Artifacts at cardiac CT: physics and solutions. RadioGraphics. https:\/\/doi.org\/10.1148\/rg.2016160079","journal-title":"RadioGraphics"},{"key":"3816_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2024.100574","author":"C Lisi","year":"2024","unstructured":"Lisi C, Moser LJ, Mergen V, Flohr T, Eberhard M, Alkadhi H (2024) Increasing the rate of datasets amenable to CTFFR and quantitative plaque analysis: value of software for reducing stair-step artifacts demonstrated in photon-counting detector CT. Eur J Radiol Open. https:\/\/doi.org\/10.1016\/j.ejro.2024.100574","journal-title":"Eur J Radiol Open"},{"key":"3816_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-023-02978-9","author":"N Kotoku","year":"2023","unstructured":"Kotoku N et al (2023) CCTA-based CABG SYNTAX score: a tool to evaluate completeness of coronary segment revascularization after bypass surgery. Int J Cardiovasc Imaging. https:\/\/doi.org\/10.1007\/s10554-023-02978-9","journal-title":"Int J Cardiovasc Imaging"},{"key":"3816_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2025.06.3519","author":"A Tai","year":"2025","unstructured":"Tai A, Noid G, Shukla ME, Shah J, Dickmann J, Paulson ES (2025) Reduction of motion artifacts in four-dimensional computed tomography using a novel reconstruction algorithm based on deformable image registration. Int J Radiat Oncol Biol Phys. https:\/\/doi.org\/10.1016\/j.ijrobp.2025.06.3519","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"3816_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-026-03770-1","author":"G Ciliberti","year":"2026","unstructured":"Ciliberti G et al (2026) Characteristics and outcomes of patients undergoing coronary computed tomography angiography for suspected acute coronary syndrome in the emergency department. Int J Cardiovasc Imaging. https:\/\/doi.org\/10.1007\/s10554-026-03770-1","journal-title":"Int J Cardiovasc Imaging"},{"key":"3816_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2026.112904","volume":"201","author":"MT Hagar","year":"2026","unstructured":"Hagar MT et al (2026) Photon-counting CT in cardiac imaging: multi-institutional guidance on technical principles, clinical evidence, and practical protocols. Eur J Radiol 201:112904. https:\/\/doi.org\/10.1016\/j.ejrad.2026.112904","journal-title":"Eur J Radiol"}],"container-title":["The International Journal of Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-026-03816-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10554-026-03816-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10554-026-03816-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T11:06:12Z","timestamp":1788087972000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10554-026-03816-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,30]]},"references-count":19,"alternative-id":["3816"],"URL":"https:\/\/doi.org\/10.1007\/s10554-026-03816-4","relation":{},"ISSN":["1875-8312"],"issn-type":[{"value":"1875-8312","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,30]]},"assertion":[{"value":"13 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The Department of Diagnostic and Interventional Radiology receives institutional research grants from Bayer, Canon, Guerbet, and Siemens. H.A. received speaker invitations from Siemens.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All patients provided a general consent for further use of their anonymized data for research. This retrospective study had ethics committee approval.","order":2,"name":"Ethics","label":"Ethics declaration","group":{"name":"EthicsHeading","label":"Declarations"}}]}}