{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,31]],"date-time":"2025-08-31T10:27:34Z","timestamp":1756636054514},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2005,6,1]],"date-time":"2005-06-01T00:00:00Z","timestamp":1117584000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dig Dis Sci"],"published-print":{"date-parts":[[2005,6]]},"DOI":"10.1007\/s10620-005-2701-y","type":"journal-article","created":{"date-parts":[[2005,6,27]],"date-time":"2005-06-27T12:45:10Z","timestamp":1119876310000},"page":"1041-1045","source":"Crossref","is-referenced-by-count":15,"title":["Double Balloon Enteroscopy\u2013The Last Blind-Point of the Gastrointestinal Tract"],"prefix":"10.1007","volume":"50","author":[{"given":"Ming-Yao","family":"Su","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nai-Jen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen-Ming","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng-Tang","family":"Chiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pang-Chi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chun-Jun","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2005,6,1]]},"reference":[{"key":"2701_CR1","first-page":"3","volume":"173","author":"H Hopkins","year":"1954","unstructured":"Hopkins H, Kapany NS: A flexible fibroscope, using static scanning. Nature 173:3, 1954","journal-title":"Nature"},{"key":"2701_CR2","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/S0016-5085(00)70430-6","volume":"118","author":"GR Zuckerman","year":"2000","unstructured":"Zuckerman GR, Prakesh C, Askin MP, et al.: AGA technical review on the evaluation and management of occult and obscure gastrointestinal bleeding. Gastroenterology 118:201\u2013221, 2000","journal-title":"Gastroenterology"},{"key":"2701_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1056\/NEJM199907013410107","volume":"341","author":"DC Rockey","year":"1999","unstructured":"Rockey DC: Occult gastrointestinal bleeding. N Engl J Med 341:38\u201345, 1999","journal-title":"N Engl J Med"},{"key":"2701_CR4","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1007\/s11894-999-0025-3","volume":"1","author":"S Lahoyi","year":"1999","unstructured":"Lahoyi S, Futami N: The small bowel as a source for obscure gastrointestinal blood loss. Curr Gastroenterol Rep 1:424\u2013430, 1999","journal-title":"Curr Gastroenterol Rep"},{"key":"2701_CR5","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1055\/s-2000-9003","volume":"32","author":"M Hayat","year":"2000","unstructured":"Hayat M, Axon AT, O Mahony S: Diagnostic yield and effect on clinical outcomes of push enteroscopy in suspected small-bowel bleeding. Endoscopy 32:369\u2013372, 2000","journal-title":"Endoscopy"},{"key":"2701_CR6","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S1052-5157(18)30150-8","volume":"29","author":"BS Lewis","year":"2000","unstructured":"Lewis BS: Enteroscopy. Gastrointest Endosc Clin N Am 29:101\u2013117, 2000","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"2701_CR7","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1016\/0016-5085(88)90001-7","volume":"94","author":"BS Lewis","year":"1988","unstructured":"Lewis BS, Waye J: Chronic gastrointestinal bleeding of obscure origin: role of small bowel enteroscopy. Gastroenterology 94:1117\u20131120, 1988","journal-title":"Gastroenterology"},{"key":"2701_CR8","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1136\/gut.37.3.346","volume":"37","author":"GR Davies","year":"1995","unstructured":"Davies GR, Gertner DJ, Benson MJ, et al.: Diagnostic, therapeutic and practical advantages of small bowel examination with a push type enteroscopy. Gut 37:346\u2013352, 1995","journal-title":"Gut"},{"key":"2701_CR9","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/S0016-5107(94)70120-2","volume":"40","author":"JS Barkin","year":"1994","unstructured":"Barkin JS, Chong J, Reiner DK: First-generation video enteroscope: fourth-generation push-type small bowel enteroscopy utilizing an overtube. Gastrointest Endosc 40:743\u2013747, 1994","journal-title":"Gastrointest Endosc"},{"key":"2701_CR10","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1055\/s-2002-25295","volume":"34","author":"B Lewis","year":"2002","unstructured":"Lewis B: Enteroscpy: Endangered by the capsule? Endoscopy 34:416\u2013417, 2002","journal-title":"Endoscopy"},{"key":"2701_CR11","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S1052-5157(18)30219-8","volume":"9","author":"R Seensalu","year":"1999","unstructured":"Seensalu R: The sonde examination. Gastrointest Endosc Clin N Am 9:37\u201359, 1999","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"2701_CR12","first-page":"878","volume":"84","author":"JJ Fiorito","year":"1989","unstructured":"Fiorito JJ, Brandt LJ, Kozicky O, et al.: The diagnostic yield of superior mesenteric angiography: Correlation with the pattern of gastrointestinal bleeding. Am J Gastroenterol 84:878\u2013881, 1989","journal-title":"Am J Gastroenterol"},{"key":"2701_CR13","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1097\/00006231-200206000-00013","volume":"23","author":"DM Howarth","year":"2002","unstructured":"Howarth DM, Tang C, Lees W: The clinical utility if nuclear imaging for the detection of occult gastrointestinal hemorrhage. Nucl Med Commun 23:591\u2013594, 2002","journal-title":"Nucl Med Commun"},{"key":"2701_CR14","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/S0022-3468(99)90370-6","volume":"34","author":"F Swaniker","year":"1999","unstructured":"Swaniker F, Soldes O, Hirschl PB: The utility of technetium 99m pertechnetate scintigraphy in the evaluation of patients with Meckel\u2019s diverticulum. J Pediatr Surg 34:760\u2013765, 1999","journal-title":"J Pediatr Surg"},{"key":"2701_CR15","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","volume":"405","author":"G Iddan","year":"2000","unstructured":"Iddan G, Meron G, Glukhovsky A, et al.: Wireless capsule endoscopy. Nature 405:417, 2000","journal-title":"Nature"},{"key":"2701_CR16","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1067\/mge.2000.105724","volume":"51","author":"F Gong","year":"2000","unstructured":"Gong F, Mills TN, Swain CP: Wireless endoscopy. Gastrointest Endosc 51:725\u2013729, 2000","journal-title":"Gastrointest Endosc"},{"key":"2701_CR17","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1053\/gast.2000.20844","volume":"119","author":"M Appleyard","year":"2000","unstructured":"Appleyard M, Fireman F, Glukhovsky A, et al.: Randomized comparison of push-enteroscopy and wireless capsule endoscopy in detecting small intestinal lesions in an animal model. Gastroenterology 119:1431\u20131438, 2000","journal-title":"Gastroenterology"},{"key":"2701_CR18","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1056\/NEJM200101183440316","volume":"34","author":"M Appleyard","year":"2001","unstructured":"Appleyard M, Glukhovsky A, Swain CP: Wireless capsule diagnostic enteroscopy for recurrent small-bowel bleeding. N Engl J Med 34:232\u2013233, 2001","journal-title":"N Engl J Med"},{"key":"2701_CR19","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1055\/s-2002-33446","volume":"34","author":"C Ell","year":"2002","unstructured":"Ell C, Remke S, May A, et al.: The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding. Endoscopy 34:685\u2013689, 2002","journal-title":"Endoscopy"},{"key":"2701_CR20","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1055\/s-2001-16208","volume":"33","author":"C Benz","year":"2001","unstructured":"Benz C, Jakobs R, Riemann JF: Do we need the overtube for push-enteroscopy? Endoscopy 33:658\u2013661, 2001","journal-title":"Endoscopy"},{"key":"2701_CR21","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1055\/s-2001-12799","volume":"33","author":"AC Taylor","year":"2001","unstructured":"Taylor AC, Chen RY, Desmond PV: Use of an overtube for enteroscopy: does it increase depth of insertion? A prospective study of enteroscopy with and without an overtube. Endoscopy 33:227\u2013230, 2001","journal-title":"Endoscopy"},{"key":"2701_CR22","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1055\/s-2003-37313","volume":"41","author":"D Hartmann","year":"2003","unstructured":"Hartmann D, Schilling D, Bolz G, et al.: Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding. Z Gastroenterol 41:377\u2013382, 2003","journal-title":"Z Gastroenterol"},{"key":"2701_CR23","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/S0016-5107(02)70037-0","volume":"56","author":"BS Lewis","year":"2002","unstructured":"Lewis BS, Swain P: Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study. Gastrointest Endosc 56:349\u2013353, 2002","journal-title":"Gastrointest Endosc"},{"key":"2701_CR24","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.1136\/gut.52.8.1122","volume":"52","author":"M Mylonaki","year":"2003","unstructured":"Mylonaki M, Fritscher-Ravens A, Swain P: Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding. Gut 52:1122\u20131126, 2003","journal-title":"Gut"},{"key":"2701_CR25","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1055\/s-2003-44582","volume":"35","author":"A May","year":"2003","unstructured":"May A, Nachbar L, Wardak A, et al.: Double-balloon enteroscopy: preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain. Endoscopy 35:985\u2013991, 2003","journal-title":"Endoscopy"}],"container-title":["Digestive Diseases and Sciences"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-005-2701-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10620-005-2701-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-005-2701-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-005-2701-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T15:35:34Z","timestamp":1559230534000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10620-005-2701-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["2701"],"URL":"https:\/\/doi.org\/10.1007\/s10620-005-2701-y","relation":{},"ISSN":["0163-2116","1573-2568"],"issn-type":[{"value":"0163-2116","type":"print"},{"value":"1573-2568","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6]]}}}