{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T15:01:29Z","timestamp":1758121289561},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2007,3,30]],"date-time":"2007-03-30T00:00:00Z","timestamp":1175212800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dig Dis Sci"],"published-print":{"date-parts":[[2007,9,1]]},"DOI":"10.1007\/s10620-006-9642-y","type":"journal-article","created":{"date-parts":[[2007,3,29]],"date-time":"2007-03-29T17:37:51Z","timestamp":1175189871000},"page":"2892-2896","source":"Crossref","is-referenced-by-count":2,"title":["Comfort and Efficacy of a Longer and Thinner Endoscope for Average Risk Colon Cancer Screening"],"prefix":"10.1007","volume":"52","author":[{"given":"R. Keith","family":"Fincher","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Myers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott","family":"McNear","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John D.","family":"Liveringhouse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard L.","family":"Topolski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennifer","family":"McNear","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2007,3,30]]},"reference":[{"key":"9642_CR1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.3322\/canjclin.55.1.10","volume":"55","author":"A Jemel","year":"2005","unstructured":"Jemel A, Murray T, Ward W, et\u00a0al. (2005) Cancer statistics, 2005. CA Cancer J Clin 55:10","journal-title":"CA Cancer J Clin"},{"key":"9642_CR2","doi-asserted-by":"crossref","first-page":"31","DOI":"10.3322\/canjclin.55.1.31","volume":"55","author":"RA Smith","year":"2005","unstructured":"Smith RA, Cokkinides V, Eyre HJ (2005) American Cancer Society guidelines for the early detention of cancer, 2005. CA Cancer J Clin 55:31\u201344","journal-title":"CA Cancer J Clin"},{"key":"9642_CR3","doi-asserted-by":"crossref","first-page":"129","DOI":"10.7326\/0003-4819-137-2-200207160-00014","volume":"137","author":"U.S. Preventative Services Task Force","year":"2002","unstructured":"U.S. Preventative Services Task Force (2002) Screening for colorectal cancer: recommendation and rationale. Ann Intern Med 137:129\u2013131","journal-title":"Ann Intern Med"},{"key":"9642_CR4","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1056\/NEJM199203053261001","volume":"326","author":"JV Selby","year":"1992","unstructured":"Selby JV, Friedman GD, Quesenberry CP, et\u00a0al. (1992) A case-control study of screening sigmoidoscopy and mortality from colorectal cancer. N Engl J Med 326:653\u2013657","journal-title":"N Engl J Med"},{"key":"9642_CR5","unstructured":"Colorectal cancer test use among persons aged 50 years\u2014United States,2001 (2003) MMWR Morb Mortal Wkly Rep 52:193"},{"key":"9642_CR6","first-page":"54","volume":"52","author":"D Rex","year":"2000","unstructured":"Rex D, Akins W, Hoff G, et\u00a0al (2000) Endoscopy around the world: perspectives on gastrointestinal endoscopy. Endoscopy 52:54\u201358","journal-title":"Endoscopy"},{"key":"9642_CR7","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1097\/00004836-198208000-00009","volume":"4","author":"DJ Ott","year":"1982","unstructured":"Ott DJ, Wu WC, Gefland DW (1982) Extent of colonic visualization with the fibreoptic sigmoidoscope. J Clin Gastroenterol 4:337\u2013341","journal-title":"J Clin Gastroenterol"},{"key":"9642_CR8","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/0016-5085(83)90149-X","volume":"84","author":"GA Lehman","year":"1983","unstructured":"Lehman GA, Buchner DM, Lappas JC (1983) Anatomical extent of fibreoptic sigmoidoscope. Gastroenterol 84:803\u2013808","journal-title":"Gastroenterology"},{"key":"9642_CR9","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1067\/mge.2001.114064","volume":"54","author":"LS Kim","year":"2001","unstructured":"Kim LS, Koch J, Yee J, et\u00a0al. (2001) Comparison of patients\u2019 experiences during imaging tests of the colon. Gastrointest Endosc 54:67\u201374","journal-title":"Gastrointest Endosc"},{"key":"9642_CR10","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1001\/archinte.160.12.1790","volume":"160","author":"RE Schoen","year":"2000","unstructured":"Schoen RE, Weissfeld JL, Bowen NJ, et\u00a0al. (2000) Patient satisfaction with screening flexible sigmoidoscopy. Arch Intern Med 160:1790\u20131796","journal-title":"Arch Intern Med"},{"key":"9642_CR11","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1055\/s-1999-13673","volume":"31","author":"J Painter","year":"1999","unstructured":"Painter J, Saunders DB, Bell GD, et\u00a0al. (1999) Depth of insertion at flexible sigmoidoscopy: implications for colorectal cancer screening and instrument design. Endoscopy 31:227\u2013231","journal-title":"Endoscopy"},{"key":"9642_CR12","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1053\/j.gastro.2005.04.005","volume":"128","author":"DF Ransohoff","year":"2005","unstructured":"Ransohoff DF (2005) Colon cancer screening in 2005: status and challenges. Gastroenterology 128:1685\u20131695","journal-title":"Gastroenterology"},{"key":"9642_CR13","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/S0889-8553(02)00059-6","volume":"31","author":"DF Ransohoff","year":"2002","unstructured":"Ransohoff DF (2002) Screening colonoscopy in balance. Issues of implementation. Gastroenterol Clin North Am 31:1031\u20131044","journal-title":"Gastroenterol Clin North Am"},{"key":"9642_CR14","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1067\/mge.2001.117594","volume":"54","author":"DK Rex","year":"2001","unstructured":"Rex DK, Lieberman DA (2001) Feasibility of colonoscopy screening: discussion of issues and recommendations regarding implementation. Gastrointest Endosc 54:662\u2013667","journal-title":"Gastrointest Endosc"},{"key":"9642_CR15","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.ypmed.2003.11.001","volume":"38","author":"KA Greiner","year":"2004","unstructured":"Greiner KA, Engelman KK, Hall MA, et\u00a0al. (2004) Barriers to colorectal cancer screening in rural primary care. Prev Med 38:269\u2013275","journal-title":"Prev Med"},{"key":"9642_CR16","first-page":"1224","volume":"51","author":"M Cotterill","year":"2005","unstructured":"Cotterill M, Gasparelli R, Kirby E (2005) Colorectal cancer detection in a rural community. Development of a colonoscopy screening program. Can Fam Physician 51:1224\u20131228","journal-title":"Can Fam Physician"},{"key":"9642_CR17","unstructured":"America's Health Insurance Plans (2004) 2002 AHIP Survey of Health Insurance Plans: Chart Book of Findings. Washington, DC: Author"},{"key":"9642_CR18","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1053\/gast.1999.0029900312","volume":"117","author":"P Schoenfeld","year":"1999","unstructured":"Schoenfeld P, Lipscomb S, Crook J, et\u00a0al. (1999) Accuracy of polyp detection by gastroenterologists and nurse endoscopists during flexible sigmoidoscopy: a randomized trial. Gastroenterology 117:312\u2013318","journal-title":"Gastroenterology"},{"key":"9642_CR19","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/S0002-9343(01)00959-7","volume":"111","author":"OS Ashley","year":"2001","unstructured":"Ashley OS, Nadel M, Ransohoff DF (2001) Achieving quality in flexible sigmoidoscopy screening for colorectal cancer. Am J Med 111:643\u2013653","journal-title":"Am J Med"},{"key":"9642_CR20","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1111\/j.1572-0241.2004.30215.x","volume":"99","author":"FA Farraye","year":"2004","unstructured":"Farraye FA, Horton K, Hersey H, et\u00a0al. (2004) Screening flexible sigmoidoscopy using an upper endoscope is better tolerated by women. Am J Gastroenterol 99:1074\u20131080","journal-title":"Am J Gastroenterol"},{"key":"9642_CR21","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/S0016-5107(96)70050-0","volume":"44","author":"JB Marshall","year":"1996","unstructured":"Marshall JB (1996) Use of a pediatric colonoscope improves success of total colonoscopy in selected adult patients. Gastrointest Endosc 44:675\u2013678","journal-title":"Gastrointest Endosc"},{"key":"9642_CR22","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1067\/mge.2002.124562","volume":"55","author":"JB Marshall","year":"2002","unstructured":"Marshall JB, Perez RA, Madsen RW (2002) Usefulness of a pediatric colonoscope for routine colonoscopy in women who has undergone hysterectomy. Gastrointest Endosc 55:838\u2013841","journal-title":"Gastrointest Endosc"}],"container-title":["Digestive Diseases and Sciences"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-006-9642-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10620-006-9642-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-006-9642-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,21]],"date-time":"2020-04-21T03:45:59Z","timestamp":1587440759000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10620-006-9642-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,30]]},"references-count":22,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2007,9,1]]}},"alternative-id":["9642"],"URL":"https:\/\/doi.org\/10.1007\/s10620-006-9642-y","relation":{},"ISSN":["0163-2116","1573-2568"],"issn-type":[{"value":"0163-2116","type":"print"},{"value":"1573-2568","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,30]]}}}