{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T03:01:19Z","timestamp":1789182079531,"version":"build-2803163510"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T00:00:00Z","timestamp":1698364800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T00:00:00Z","timestamp":1698364800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Dig Dis Sci"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1007\/s10620-023-08068-z","type":"journal-article","created":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T15:02:00Z","timestamp":1698418920000},"page":"4321-4325","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Sems Sensibility: Biliary Stent Migration into the Oesophagus"],"prefix":"10.1007","volume":"68","author":[{"given":"Flaminia","family":"Frattaroli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marzia","family":"Varanese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Esposito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Augusto","family":"Lauro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Frattaroli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,10,27]]},"reference":[{"key":"8068_CR1","first-page":"95","volume":"34","author":"J Deviere","year":"1988","unstructured":"Deviere J, Baize M, de Toeuf J et al. Long-term follow-up of patients with hilar malignant stricture treated by endoscopic internal biliary drainage. GastrointestEndosc. 1988;34:95\u2013101.","journal-title":"GastrointestEndosc."},{"key":"8068_CR2","first-page":"96","volume":"36","author":"J Devi\u00e8re","year":"1990","unstructured":"Devi\u00e8re J, Devaere S, Baize M et al. Endoscopic biliary drainage in chronic pancreatitis. GastrointestEndosc. 1990;36:96\u2013100.","journal-title":"GastrointestEndosc."},{"key":"8068_CR3","first-page":"486","volume":"47","author":"S Lahoti","year":"1998","unstructured":"Lahoti S, Catalano MF, Geenen JE et al. Endoscopic retrieval of proximally migrated biliary and pancreatic stents: experience of a large referral center. GastrointestEndosc. 1998;47:486\u2013491.","journal-title":"GastrointestEndosc."},{"key":"8068_CR4","first-page":"341","volume":"38","author":"JF Johanson","year":"1992","unstructured":"Johanson JF, Schmalz MJ, Geenen JE. Incidence and risk factors for biliary and pancreatic stent migration. GastrointestEndosc. 1992;38:341\u2013346.","journal-title":"GastrointestEndosc."},{"key":"8068_CR5","first-page":"513","volume":"42","author":"PR Tarnasky","year":"1995","unstructured":"Tarnasky PR, Cotton PB, Baillie J et al. Proximal migration of biliary stents: attempted endoscopic retrieval in forty-one patients. GastrointestEndosc. 1995;42:513\u2013520.","journal-title":"GastrointestEndosc."},{"key":"8068_CR6","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiology.199.2.8668775","volume":"199","author":"WC Culp","year":"1996","unstructured":"Culp WC, McCowan TC, Lieberman RP et al. Biliary strictures in liver transplant recipients: treatment with metal stents. Radiology. 1996;199:339\u2013346.","journal-title":"Radiology."},{"key":"8068_CR7","first-page":"780","volume":"50","author":"OP Chaurasia","year":"1999","unstructured":"Chaurasia OP, Rauws EA, Fockens P et al. Endoscopic techniques for retrieval of proximally migrated biliary stents: the Amsterdam experience. GastrointestEndosc. 1999;50:780\u2013785.","journal-title":"GastrointestEndosc."},{"key":"8068_CR8","first-page":"252","volume":"37","author":"MJ Schmalz","year":"1991","unstructured":"Schmalz MJ, Johanson JF, Geenen JE et al. Migrated biliary and pancreatic stents; complications and techniques for retrieval. GastrointestEndosc. 1991;37:252.","journal-title":"GastrointestEndosc."},{"key":"8068_CR9","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/S0033-8389(22)02662-8","volume":"28","author":"J Lammer","year":"1990","unstructured":"Lammer J. Biliary endoprostheses. Plastic versus metal stents. Radiol Clin North Am. 1990;28:1211\u20131222.","journal-title":"Radiol Clin North Am."},{"key":"8068_CR10","first-page":"301","volume":"152","author":"H Ahlstr\u00f6m","year":"1986","unstructured":"Ahlstr\u00f6m H, L\u00f6relius LE, Jacobson G. Inoperable biliary obstruction treated with percutaneously placed endoprosthesis. Acta Chir Scand. 1986;152:301\u2013303.","journal-title":"Acta Chir Scand."},{"key":"8068_CR11","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1016\/0140-6736(92)92752-2","volume":"340","author":"PH Davids","year":"1992","unstructured":"Davids PH, Groen AK, Rauws EA et al. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction. Lancet. 1992;340:1488\u20131492.","journal-title":"Lancet."},{"key":"8068_CR12","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/S0002-9610(99)00211-1","volume":"178","author":"GD De Palma","year":"1999","unstructured":"De Palma GD, Catanzano C. Stenting or surgery for treatment of irretrievable common bile duct calculi in elderly patients? Am J Surg. 1999;178:390\u2013393.","journal-title":"Am J Surg."},{"issue":"Suppl 1","key":"8068_CR13","first-page":"E58","volume":"46","author":"H Kawakami","year":"2014","unstructured":"Kawakami H, Kuwatani M, Kawakubo K et al. Endoscopic salvage technique for spontaneous dislocation and tumor ingrowth of a partially covered, self-expandable metallic stent after endoscopic ultrasound-guided choledochoduodenostomy. Endoscopy 2014;46(Suppl 1):E58\u2013E59.","journal-title":"Endoscopy"},{"key":"8068_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/bcr-2013-009124","volume":"2013","author":"M Jones","year":"2013","unstructured":"Jones M, George B, Jameson J et al. Biliary stent migration causing perforation of the caecum and chronic abdominal pain. BMJ Case Rep. 2013;2013:1.","journal-title":"BMJ Case Rep."},{"key":"8068_CR15","first-page":"924","volume":"74","author":"TO Lankisch","year":"2011","unstructured":"Lankisch TO, Alten TA, Lehner F et al. Biliary stent migration with colonic perforation: a very rare complication and the lesson that should be learned from it. GastrointestEndosc. 2011;74:924\u2013925.","journal-title":"GastrointestEndosc."},{"key":"8068_CR16","first-page":"S67","volume":"32","author":"R Mofidi","year":"2000","unstructured":"Mofidi R, Ahmed K, Mofidi A et al. Perforation of ileum: an unusual complication of distal biliary stent migration. Endoscopy. 2000;32:S67.","journal-title":"Endoscopy."},{"key":"8068_CR17","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1111\/j.1572-0241.2006.00509.x","volume":"101","author":"R Lanteri","year":"2006","unstructured":"Lanteri R, Naso P, Rapisarda C et al. Jejunal perforation for biliary stent dislocation. Am J Gastroenterol. 2006;101:908\u2013909.","journal-title":"Am J Gastroenterol."},{"key":"8068_CR18","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1093\/jscr\/2011.3.6","volume":"2011","author":"A Peter","year":"2011","unstructured":"Peter A, Walker M, Shinil K et al. Biliary stent migration presenting as transdiverticular sigmoid perforation. J Surg Case Rep. 2011;2011:6.","journal-title":"J Surg Case Rep."},{"key":"8068_CR19","doi-asserted-by":"publisher","first-page":"5397","DOI":"10.3748\/wjg.v13.i40.5397","volume":"13","author":"T Namdar","year":"2007","unstructured":"Namdar T, Raffel AM, Topp SA et al. Complications and treatment of migrated biliary endoprostheses: a review of the literature. World J Gastroenterol 2007;13:5397\u20135399.","journal-title":"World J Gastroenterol"},{"key":"8068_CR20","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.3748\/wjg.v20.i5.1318","volume":"20","author":"K Yoshiaki","year":"2014","unstructured":"Yoshiaki K, Masami O, Yohei K et al. Risk factors for proximal migration of biliary tube stents. World J Gastroenterol. 2014;20:1318\u20131324.","journal-title":"World J Gastroenterol."},{"key":"8068_CR21","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/S0016-5107(92)70429-5","volume":"38","author":"JF Johanson","year":"1992","unstructured":"Johanson JF, Schmalz MJ, Geenen JE. Incidence and risk factors for biliary and pancreatic stent migration. Gastrointest Endosc. 1992;38:341\u2013346.","journal-title":"Gastrointest Endosc."},{"key":"8068_CR22","unstructured":"Gore WL & Associates, Inc. Migration Summary for GORE\u00ae\u00a0VIABIL\u00ae\u00a0Biliary Endoprosthesis and Boston Scientific WALLFLEX Biliary RX Fully Covered Stent. Flagstaff, AZ: W. L. Gore & Associates, Inc; 2017"},{"key":"8068_CR23","first-page":"84","volume":"76","author":"H Isayama","year":"2012","unstructured":"Isayama H, Mukai T, Itoi T et al. Comparison of partially covered nitinol stents with partially covered stainless stents as a historical control in a multicenter study of distal malignant biliary obstruction: the WATCH study. GastrointestinalEndoscopy 2012;76:84\u201392.","journal-title":"GastrointestinalEndoscopy"},{"key":"8068_CR24","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1007\/s00464-002-9163-5","volume":"17","author":"R Diller","year":"2003","unstructured":"Diller R, Senninger N, Kautz G et al. Stent migration necessitating surgical intervention. Surg Endosc. 2003;17:1803\u20131807.","journal-title":"Surg Endosc."},{"key":"8068_CR25","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1016\/j.cursur.2005.03.011","volume":"62","author":"G Miller","year":"2005","unstructured":"Miller G, Yim D, Macari M et al. Retroperitoneal perforation of the duodenum from biliary stent erosion. Curr Surg. 2005;62:512\u2013515.","journal-title":"Curr Surg."},{"key":"8068_CR26","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1111\/ases.12033","volume":"6","author":"MN Saravanan","year":"2013","unstructured":"Saravanan MN, Mathai V, Kapoor D et al. Fractured metallic biliary stent causing obstruction and jejunal perforation. Asian J Endosc Surg. 2013;6:234\u2013236.","journal-title":"Asian J Endosc Surg."},{"key":"8068_CR27","doi-asserted-by":"publisher","first-page":"E148","DOI":"10.1055\/a-1025-1773","volume":"52","author":"Hoonsub So","year":"2020","unstructured":"So Hoonsub, Lee Jae Hoon, Noh JinHee et al. Surgical removal of a hepaticogastrostomy stent because of its recurrent dislocation into the esophagus. Endoscopy 2020;52:E148\u2013E149.","journal-title":"Endoscopy"}],"container-title":["Digestive Diseases and Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-023-08068-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10620-023-08068-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10620-023-08068-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T14:11:13Z","timestamp":1699539073000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10620-023-08068-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,27]]},"references-count":27,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["8068"],"URL":"https:\/\/doi.org\/10.1007\/s10620-023-08068-z","relation":{},"ISSN":["0163-2116","1573-2568"],"issn-type":[{"value":"0163-2116","type":"print"},{"value":"1573-2568","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,27]]},"assertion":[{"value":"18 April 2023","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 October 2023","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare regarding this case presentation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}